scholarly journals Development of a radiographic dental implant guide for identification of dental implant types

2020 ◽  
Vol 75 (8) ◽  
pp. 432-437
Author(s):  
Lisa Vermeulen ◽  
Aladdin Speelman ◽  
Valdiela Daries ◽  
Vincent Philips

INTRODUCTION: Identification of dental implant types can be a complex process for inexperienced health care professionals. Dental implants can have subtle differences in their morphology, which make it difficult to distinguish them from one another The unique appearance of dental anatomy and the placement of custom restorations ensure accurate identification of bodies or human remains when radiographic techniques are correctly applied. AIMS AND OBJECTIVES: To develop a radiographic dental implant guide for ten common dental implant types currently used in the Western Cape, South Africa; using their morphological characteristics observed on pantomographs. DESIGN: The methodology considered for this research study was a positivist approach through a quantitative, exploratory, non-experimental research design. METHODS: Ten commonly used dental implants were radiographed at straight tube (ST), off-centre (OC) and severe off-centre (SOC) angles to create a reference instrument Two reviewers used the morphologies of the different dental implant types, namely the apex, thread and neck, observed on ante-mortem pantomographs, and compared it to the appearance of the dental implants in the reference instrument to make a positive identification match. The straight tube image of all ten dental implant types in the reference instrument was used as the initial point of reference to positively identify the morphological characteristics of each dental implant type on the pantomographs. RESULTS: A total of 380 dental implants could be identified on 105 pantomographs reviewed. Of the 380 dental implants, 350 dental implants (91%) were identified as dental implant types listed in the reference instrument while 30 dental implants were identified as another type of dental implant type not listed in the reference instrument A total of 208 dental implants (54.2%) could be positively identified on the ante-mortem pantomographs using the straight tube images in the reference instrument. The morphological characteristics of the dental implant types were described using x-ray imaging of dental implants. The ten commonly used dental implants types could be positively identified by two independent reviewers and based on this a radiographic dental implant guide was developed. CONCLUSION: Each dental implant type had unique morphological characteristics as well as similarities which enabled distinction between the different dental implant types. The dental implant guide developed could be used by dentistry and radiography students. The dental implant guide may be useful in the field of forensic dentistry and forensic radiology.

Materials ◽  
2019 ◽  
Vol 12 (1) ◽  
pp. 164 ◽  
Author(s):  
Jenny Zwei-Chieng Chang ◽  
Pei-I Tsai ◽  
Mark Yen-Ping Kuo ◽  
Jui-Sheng Sun ◽  
San-Yuan Chen ◽  
...  

A mismatch of elastic modulus values could result in undesirable bone resorption around the dental implant. The objective of this study was to optimize direct metal laser sintering (DMLS)-manufactured Ti6Al4V dental implants’ design, minimize elastic mismatch, allow for maximal bone ingrowth, and improve long-term fixation of the implant. In this study, DMLS dental implants with different morphological characteristics were fabricated. Three-point bending, torsional, and stability tests were performed to compare the mechanical properties of different designs. Improvement of the weaker design was attempted by augmentation with a longitudinal 3D-printed strut. The osseointegrative properties were evaluated. The results showed that the increase in porosity decreased the mechanical properties, while augmentation with a longitudinal weight-bearing strut can improve mechanical strength. Maximal alkaline phosphatase gene expression of MG63 cells attained on 60% porosity Ti6Al4V discs. In vivo experiments showed good incorporation of bone into the porous scaffolds of the DMLS dental implant, resulting in a higher pull-out strength. In summary, we introduced a new design concept by augmenting the implant with a longitudinal weight-bearing strut to achieve the ideal combination of high strength and low elastic modulus; our results showed that there is a chance to reach the balance of both biologic and mechanical demands.


Author(s):  
А.С. Рыбалко ◽  
А.С. Григорьян ◽  
А.А. Орлов

Цель исследования состояла в разработке неинвазивного метода диагностики состояния тканей периимплантационной зоны после постановки дентальных имплантатов, а также прогноза течения послеоперационного периода и ранней диагностики послеоперационных осложнений, таких, как мукозит и периимплантит, при одноэтапном методе дентальной имплантации. Методы. В исследовании представлена цитологическая характеристика отпечатков из области контакта имплантата с десной, в которых оценивали состояние эпителиальных клеток при различных проявлениях цитопатологии. Определяли индекс деструкции (ИД) и воспалительно-деструктивный индекс (ВДИ) в клетках воспалительного инфильтрата, которые сопоставляли с клинической картиной течения послеоперационного периода. Сроки забора цитологического материала 1, 5, 15, 25, 30, 60, 120 дней после постановки имплантатов. Количество исследованных цитограмм - 442 от 11 пациентов (по 1-2 имплантата). Общий массив использованных для вычисления интегральных показателей составил »2550. Результаты. Было установлено, что в сроки 1-5 дней после постановки дентальных имплантатов происходит резкое повышение показателей ИД (до 7500 ± 15) и ВДИ (до 80 ± 20), что отражает процесс развития в области имплантатов острых воспалительных реакций. В отдаленные сроки наблюдений отмечалось 2 варианта развития событий. Первый из них характеризовался сохранением во все сроки высоких показателей ИД и ВДИ. Для второго варианта динамики показателей было характерно их падение, что соответствовало развитию процесса остеоинтеграции дентальных имплантатов. The objectives of the investigation were to develop protocols evaluating the validity and effectiveness of the cytological method for diagnosis and prognosis of tissue conditions adjacent to a dental implant. Methods. This study examined the cytological characteristics of imprints of the gingiva-implant contact area, a. the correlation of quantitative ratios of epithelial cells either with or without hystopathological manifestations (an index of destruction, ID); b. ratio of cells of the inflammatory infiltrate (an inflammatory and destructive index, IDI); these data were researched in relation with dynamics of the clinical pictures during a postoperative period.The cytological material was obtained 1, 5, 15, 25, 30, 60, 120 days after dental implantation. Totally 442 cytogramme from 11 patients (1-2 implant per a patient) were assayed. The data array for computation of integrated indicators was composed of ca. 2550 data points. Results. A significant increase of ID (7500 ± 15) and IDI (80 ± 20) indicators, which reflects the development of acute inflammatory reactions in tissues neighboring an implant, was observed within 1-5 days following the insertion of dental implants. Long-term observations revealed two scenarios. The first scenario was characterized by the retention of high levels of ID and IDI over the period of observations. The second scenario featured the reduction of ID and IDI indices, which corresponded to the development of the osseointegration of dental implants.


2011 ◽  
pp. 96-103
Author(s):  
Quang Hai Nguyen ◽  
Toai Nguyen

1. Background: Loss of permanent teeth is very common, affected chewing function, speech and aesthetics; restoration of missing teeth with dental implant has several advantages, but we need thoroughly study the clinical and X ray features at the position at missing teeth, then to select the type of implant and make the best plan for the dental implant patients. 2. Materials and method: Cross-section descriptive study. From January 2009 to November 2010, study with 56 patients with 102 implants of MIS and Megagen systems at the Faculty of Odonto-Stomatology, Hue College of Medicine and Pharmacy and Vietnam-Cuba Hospital in Ha Noi. 3. Results: Distributed equally in male and female, common ages 40 – 59 (55,4%), the majority of missing teeth occurs in the lower jaw (63,8%) and especially, the teeth 36 and 46 (25,4%). The majority of missing teeth due to dental caries, dental pulp and apical diseases (64,7%) of the molar teeth (51,9%); the most position of missing tooth have enough bone for dental implants (87,3%), time of tooth loss and bone status in the position of tooth loss are related to each other (p < 0,01). Diameter and length of implant usually used 4.0 – 6.0 mm (63,7%) and 8.5 – 13.0 mm (83,3%). 4. Conclusion: Clinical and X ray features of edentulous patients has an important role in determining the type of implants and treatment planning of dental implants. Key words: Loss of permanent teeth, X ray and clinical features, Dental implant.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
George Deryabin ◽  
Simonas Grybauskas

Abstract Background The purpose of this study was to analyze medium-to-long-term implant success and survival rates, and lower lip sensory disturbance after placement of dental implants with simultaneous inferior alveolar nerve (IAN) repositioning. Methods Fifteen patients (3 men, 12 women) treated in two centers were included in this retrospective study. The ages of the participants ranged from 19 to 68. A total of 48 dental implants were placed in 23 posterior mandibular segments simultaneously with IAN transposition or lateralization. The residual bone above the IAN ranged from 0.5 to 7.0 mm. Crestal bone changes were measured using cone beam computed tomography (CBCT) images. Disturbance of the IAN was evaluated subjectively using a modified questionnaire. Results The healing process was uneventful in fourteen patients. In one patient, spontaneous fracture of the operated mandible occurred on tenth day after the surgery. The implant in the fracture line was removed at the time of open reduction and fixation. One more implant was lost after 5 years of loading. Therefore, the overall dental implant survival rate was 95.8%, whereas all implants in function were judged as successful after a follow-up period of 1 to 10 years. Transient neurosensory disturbances (ND) were observed in all patients who underwent IAN lateralization and IAN transposition. At follow-up times of 3 years, 5 years, and 10 years, weak hypoesthesia remained in two subjects treated with IAN transposition. None of the patients developed neuropathic pain after the procedure. Conclusions Within the limitations of this study, we conclude that reconstruction of severely resorbed mandibles with dental implants in conjunction with IAN repositioning is an effective and reliable technique. Although neurosensory disturbances are the most common complication after surgery, they tend to resolve over time. Advanced surgical skills are required to perform this technique.


2013 ◽  
Vol 70 (6) ◽  
pp. 586-594 ◽  
Author(s):  
Zoran Vlahovic ◽  
Branko Mihailovic ◽  
Zoran Lazic ◽  
Mileta Golubovic

Background/Aim. Flapless implant surgery has become very important issue during recent years, mostly thanks to computerization of dentistry and software planning of dental implants placements. The aim of this study was to compare flap and flapless surgical techniques for implant placement through radiographic and radiofrequency analyses. Methods. The experiment was made in five domestic pigs. Nine weeks following domestic pigs teeth extraction, implants were placed, on the right side using surgical technique flap, and flapless on the left side. Digital dental Xrays were applied to determine primary dental implant stability quality (ISQ). At certain intervals, not later than three months, the experimental animals were sacrificed, and just before it, control X-rays were applied to measure dental implants stability. Results. Radiographic analysis showed that peri-implant bone resorption in the first 4 weeks following placement implants with flap and flapless surgical techniques was negligible. After the 3 months, mean value of peri-implant bone resorption of the implants placed using flap technique was 1.86 mm, and of those placed using flapless technique was 1.13 mm. In relation to the primary dental implant stability in the first and second week there was an expected decrease in ISQ values, but it was less expressed in the dental implants placed using the flapless technique. In the third week the ISQ values were increased in the dental implants placed by using both techniques, but the increase in flapless implant placement was higher (7.4 ISQ) than in flap implant placement (1.5 ISQ). The upward trend continued in a 4- week period, and after 3 months the dental implant stability values in the implants placed using flap technique were higher than the primary stability for 7.1 ISQ, and in the implants placed using flapless technique were higher comparing to the primary stability for 10.1 ISQ units. Conclusion. Based on the results of radiographic and resonance frequency analyses it can be concluded that the flapless technique in surgical implants placemat, leads to better results.


2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Congzhao Fan ◽  
Xiaojin Li ◽  
Jun Zhu ◽  
Jingyuan Song ◽  
Hui Yao

The medicinal plantFerulahas been widely used in Asian medicine, especially in Uyghur medicine in Xinjiang, China. Given that various substitutes and closely related species have similar morphological characteristics,Ferulais difficult to distinguish based on morphology alone, thereby causing confusion and threatening the safe use ofFerula. In this study, internal transcribed spacer 2 (ITS2) sequences were analyzed and assessed for the accurate identification of two salableFerulaspecies (Ferula sinkiangensisandFerula fukangensis) and eight substitutes or closely related species. Results showed that the sequence length of ITS2 ranged from 451 bp to 45 bp, whereas guanine and cytosine contents (GC) were from 53.6% to 56.2%. A total of 77 variation sites were detected, including 63 base mutations and 14 insertion/deletion mutations. The ITS2 sequence correctly identified 100% of the samples at the species level using the basic local alignment search tool 1 and nearest-distance method. Furthermore, neighbor-joining tree successfully identified the genuine plantsF. sinkiangensisandF. fukangensisfrom their succedaneum and closely related species. These results indicated that ITS2 sequence could be used as a valuable barcode to distinguish Uyghur medicineFerulafrom counterfeits and closely related species. This study may broaden DNA barcoding application in the Uyghur medicinal plant field.


2017 ◽  
Vol 907 ◽  
pp. 104-118
Author(s):  
Maria Stoicănescu ◽  
Eliza Buzamet ◽  
Dragos Vladimir Budei ◽  
Valentin Craciun ◽  
Roxana Budei ◽  
...  

Dental implants are becoming increasingly used in current dental practice. This increased demand has motivated manufacturers to develop varieties of product through design, but also looking for new materials used to improve surface characteristics in order to obtain a better osseointegration. But the increase in the use of implants goes to a consequent increase in the number of failures. These failures are caused either by treatment complications (peri-implantitis), by fatigue breakage under mechanical over-stress, by defective raw material, or due to errors during the insertion procedures. Although they are rare, these complications are serious in dentistry. Before to market a dental implant to clinical practitioners, the product is validated among other determinations in number of biocompatibility research. Raw material issues, details about its structure and properties are less published by the scientific literature, but all this are subject of a carefully analysis of the producers. Breaking of dental implants during surgical procedures, during the prosthetic procedures or during use (chewing, bruxism, accidents, etc.), is the second most common cause of loss of an implant after consecutive peri-implantitis rejection. Although the frequency of this type of failure for a dental implant is much smaller than those caused by the peri-implantitis, a detailed study of broken implants can explain possible causes. The use of scanning electron microscopy (SEM) in the study of the cleave areas explain the production mechanism of cleavages, starting from micro-fissures in the alloy used for the production of dental implants. These micro-fissures in weak areas of the implant (anti-rotational corners of the polygons, etc.) could generate a serious risk of cleavage first time when a higher force is applied.


Author(s):  
Giovanni de Almeida Prado Di Giacomo ◽  
Patrícia Cury ◽  
Airton Moreira da Silva ◽  
Jorge Vicente Lopes da Silva ◽  
Carlos Eduardo Pompeo Souto ◽  
...  

This study was designed to evaluate the accuracy of a novel computer-designed and selectively laser sintered surgical guide for flapless dental implant placement in the edentulous jaw. Fifty dental implants were placed in 11 patients with at least one totally edentulous jaw. Initially, cone-beam computed tomography (CBCT) was performed in each patient to define the virtual position of the dental implants based on the assessment of bone availability and the proposed dental prosthesis. After virtual planning, 3D surgical guides were printed using selective laser sintering. CBCT was repeated after the surgery, and the pre-and postoperative images were overlapped in the CAD software to compare the planned and actual positions of the dental implants using a one-sample t-test. The mean ± angular standard deviation between the long axes of the planned and final dental implant positions was 4.58 ±2.85 degrees; The linear deviation in the coronal position was  0.87 ± 0.49 mm and  in the apical region of the dental implants was 1.37 ± 0.69 mm. These differences were statistically significant (p &lt;0.001). The proposed modifications reduced the deviations, resulting in an improvement in the technique. We were able to place implants and temporary prostheses using the present protocol, taking into account the differences between the planned and final positions of the dental implants.


2018 ◽  
Vol 44 (5) ◽  
pp. 341-343
Author(s):  
Vugar Gurbanov ◽  
Damla Torul ◽  
Dilara Kazan

Accidental displacement of dental implants into the anatomical spaces is a rare complication that may be accompanied by tissue damage, functional disturbance, psychological distress, and medicolegal conditions. The aim of this report is to present an unusual case of a dental implant that displaced into the mandibular canal and to highlight the importance of adequate preoperative planning and surgical knowledge.


Author(s):  
Luciano Cincurá Silva Santos ◽  
Renato Piai Pereira ◽  
João Milton Rocha Gusmão ◽  
Onily Duarte Silva de Almeida

Dental implants and alternatives for patients requiring restoration of stomatognathic system through the replacement of dental units are an increasingly common practice. Treatment of patients with additional complications to dental implant restorations is a constant challenge, especially the patients described in the literature about the failure involving the use of bisphosphonates based drugs, those being touted as directly responsible for the presence of a pathological condition called bisphosphonate-related osteonecrosis of the jaw. A search through two databases was conducted to clarify doubts about the actual influence of factors presented and its true relevance to clinical practice, promoting the knowledge and more consistent strategies in cases requiring rehabilitation intervention. The results show the need for additional research on these topics.


Sign in / Sign up

Export Citation Format

Share Document