scholarly journals Variables of influence on thermal performance of buildings under transient conditions

2021 ◽  
Vol 12 ◽  
pp. e021023
Author(s):  
Camila Carvalho Ferreira ◽  
Henor Artur de Souza ◽  
Joyce Correna Carlo

Residential buildings significantly increase electricity demand, especially in developing countries. In this case, the requirements addressed by the standards can ensure the climatic adequacy of the envelope, enhance thermal performance, and promote thermal comfort conditions while reducing energy consumption. However, the criteria for evaluating the thermal performance of a building’s envelope that is commonly adopted in energy performance standards and codes have proved to be inefficient in hot climates. The heat exchanges within buildings are dependent on solar radiation and ventilation. The purpose of this article is to establish the variables with the greatest influence on the thermal performance of naturally ventilated dwellings in hot climates (equatorial, tropical and subtropical). For this investigation, a factorial design was adopted for sensitivity analysis. The structure of the factorial experiment defined the simulations of four patterns of single-family and multifamily residential buildings. We varied the thermophysical properties of the external walls and roofs, the heat gain coefficient of the openings, and natural ventilation. Brazil was adopted as a basis for climate analysis, including equatorial, tropical and subtropical climates. The analyses were based on comfort hours in an adaptive model and statistically evaluated using Analysis of Variance (ANOVA) tests. In general, the absorption of the walls and cover, the thermal transmittance of the cover and the natural ventilation were the variables of greatest influence on thermal comfort in a hot climate.

2018 ◽  
Vol 3 (7) ◽  
pp. 357
Author(s):  
Lobna Hassan Ali Hassan Elgheriani ◽  
Parid Wardi ◽  
AbdulBasit Ali Ali Ahmed

Natural ventilation is an effectual passive design approach to create a better indoor thermal condition as well as energy efficiency. The primary goal of building design is providing a healthy and comfortable indoor environment titled as sustainable architecture. Literature suggests that the significant feature that alteration has to take place on for better energy performance is the envelope design. This paper aims to augment the Window to Wall Ratio (WWR), orientation and courtyard corridor size for improving the design of naturally ventilated courtyard high-rise residential buildings. Briefly, the findings indicate that contending with WWR, orientation and courtyard corridor size could increase the potential of improving its natural ventilation and thus, thermal performance.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3311
Author(s):  
Víctor Pérez-Andreu ◽  
Carolina Aparicio-Fernández ◽  
José-Luis Vivancos ◽  
Javier Cárcel-Carrasco

The number of buildings renovated following the introduction of European energy-efficiency policy represents a small number of buildings in Spain. So, the main Spanish building stock needs an urgent energy renovation. Using passive strategies is essential, and thermal characterization and predictive tests of the energy-efficiency improvements achieving acceptable levels of comfort for their users are urgently necessary. This study analyzes the energy performance and thermal comfort of the users in a typical Mediterranean dwelling house. A transient simulation has been used to acquire the scope of Spanish standards for its energy rehabilitation, taking into account standard comfort conditions. The work is based on thermal monitoring of the building and a numerical validated model developed in TRNSYS. Energy demands for different models have been calculated considering different passive constructive measures combined with real wind site conditions and the behavior of users related to natural ventilation. This methodology has given us the necessary information to decide the best solution in relation to energy demand and facility of implementation. The thermal comfort for different models is not directly related to energy demand and has allowed checking when and where the measures need to be done.


2020 ◽  
Vol 13 (1) ◽  
pp. 201
Author(s):  
Pau Chung Leng ◽  
Gabriel Hoh Teck Ling ◽  
Mohd Hamdan Ahmad ◽  
Dilshan Remaz Ossen ◽  
Eeydzah Aminudin ◽  
...  

The provision requirement of 10% openings of the total floor area stated in the Uniform Building By-Law 1984 Malaysia is essential for natural lighting and ventilation purposes. However, focusing on natural ventilation, the effectiveness of thermal performance in landed residential buildings has never been empirically measured and proven, as most of the research emphasized simulation modeling lacking sufficient empirical validation. Therefore, this paper drawing on field measurement investigates natural ventilation performance in terraced housing with an air-well system. The key concern as to what extent the current air-well system serving as a ventilator is effective to provide better thermal performance is to be addressed. By adopting an existing single-story air-welled terrace house, indoor environmental conditions and thermal performance were monitored and measured using HOBO U12 air temperature and humidity, the HOBO U12 anemometer, and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter for a six-month duration. The results show that the air temperature of the air well ranged from 27.48 °C to 30.92 °C, with a mean relative humidity of 72.67% to 79.25%. The mean air temperature for a test room (single-sided ventilation room) ranged from 28.04 °C to 30.92 °C, with a relative humidity of 70.16% to 76.00%. These empirical findings are of importance, offering novel policy insights and suggestions. Since the minimum provision of 10% openings has been revealed to be less effective to provide desirable thermal performance and comfort, mandatory compliance with and the necessity of the bylaw requirement should be revisited.


2020 ◽  
pp. 1420326X2096115
Author(s):  
Jaime Resende ◽  
Marta Monzón-Chavarrías ◽  
Helena Corvacho

Buildings account for 34% of world energy consumption and about half of electricity consumption. The nearly/Net Zero Energy Building (nZEB/NZEB) concepts are regarded as solutions for minimizing this problem. The countries of Southern Europe, which included the nZEB concept recently in their regulatory requirements, have both heating and cooling needs, which adds complexity to the problem. Brazil may benefit from their experience since most of the Brazilian climate zones present significant similarities to the Southern European climate. Brazil recently presented a household energy consumption increase, and a growing trend in the use of air conditioning is predicted for the coming decades. Simulations with various wall and roof solutions following the Brazilian Performance Standard were carried out in a low standard single-family house in three different climate zones in order to evaluate thermal comfort conditions and energy needs. Results show that in milder climate zones, achieving thermal comfort with a low energy consumption is possible, and there is a great potential to achieve a net zero-energy balance. In the extreme hot climate zone, a high cooling energy consumption is needed to provide thermal comfort, and the implementation of a nearly zero-energy balance may be more feasible.


2020 ◽  
Vol 41 (3) ◽  
pp. 247-260
Author(s):  
Roy Candra Sigalingging ◽  
David Chow ◽  
Steve Sharples

In a hot and humid tropical climate, natural ventilation brings high levels of moisture into dwellings that, together with occupant activity, can result in very elevated internal relative humidity levels. Coupling these high relative humidities with high internal air temperatures creates occupant thermal discomfort, which is typically ameliorated in the tropics using energy-intensive air conditioning systems. This paper has investigated the potential benefits for thermal comfort and energy usage of applying the German Passivhaus standard to tropical dwellings. By creating a super insulated and air-tight envelope, the Passivhaus standard reduces fabric heat transfer, controls air infiltration and provides low-energy comfort. Applying this approach to a tropical terraced house might be effective but could, potentially, have an adverse impact on mechanical cooling demand. This study took an actual terraced property in Jakarta, Indonesia and thermally modelled its performance as insulation and airtightness levels were incrementally improved up to the Passivhaus standard. Field measurements in the dwelling of air temperature and relative humidity were used to validate the thermal model of the existing house. The validated model then tested the feasibility of meeting the Passivhaus energy standard for cooling in the modified tropical house. Simulation allowed the effects of air conditioning (AC) and dehumidifiers on thermal comfort and cooling loads to be investigated. The research develop the Passivhaus building model that had the floor insulation removed to let the ground floor act as a thermal sink and potentially provide radiant cooling. Analysis revealed that the building’s predicted air temperatures were affected in a beneficial way by having the Passivhaus without floor insulation. Practical application: Cooling in hot and humid tropical region is an energy-intensive approach. Design approaches that can bring comfort and save energy for the occupant are essential. The success of Passivhaus standard in mild climate might be transferable to bring comfort in tropical housing. Best practice can be developed by analysing the Passivhaus building performance in hot and humid tropical region.


2019 ◽  
Vol 158 ◽  
pp. 3319-3324 ◽  
Author(s):  
Vincent J.L. Gan ◽  
M. Deng ◽  
Y. Tan ◽  
W. Chen ◽  
Jack C.P. Cheng

2011 ◽  
Vol 20 (1) ◽  
pp. 101-111 ◽  
Author(s):  
Baizhan Li ◽  
Wei Yu ◽  
Meng Liu ◽  
Nan Li

Yangtze River Valley is situated within the Hot Summer and Cold Winter zone, and residents in this region of China would require HVAC system to alleviate thermal comfort conditions, although this is tempered by the Design Code (DBJ50-071-2007) for energy efficiency. A 1-year survey of about 200 residential homes was carried out in eight cities covering the breadth of the region. The acceptable temperature range for the residents in this area was 16.3—28.1°C and the thermal neutral temperature was found to be 27.6°C in summers and 17.5°C in winters. People in different area can vary in their adaptability and comfortableness. Therefore, there is a need to investigate the national comfort parameter introduced in the Code for Design of Heating and Ventilation and Air Conditioning (GB50019-2003). The results found that if air-conditioning system was set to 27.5°C instead of 26°C as required by GBJ19-87: Design Standard of Heating and Ventilation and Air Conditioning, a 16.5% saving of energy consumption could be achieved. The findings demonstrated the role of natural ventilation in the expansion of the thermal comfort zone for the residents, especially during the summer seasons. A climatic adaptability model has been established by this study to contribute to the passive climatic design strategies for a better economic and energy efficiency of buildings.


Biomimetics ◽  
2022 ◽  
Vol 7 (1) ◽  
pp. 14
Author(s):  
Miguel Chen Austin ◽  
Kevin Araque ◽  
Paola Palacios ◽  
Katherine Rodríguez Maure ◽  
Dafni Mora

Urban growth has increased the risk of over-heating both in the microclimate and inside buildings, affecting thermal comfort and energy efficiency. That is why this research aims to evaluate the energy performance of buildings in terms of thermal comfort (operative temperature (OP) levels, satisfied hours of natural ventilation SHNV, thermal lag), and energy efficiency (roof heat gains and surface temperatures) in an urban area in Panama City, using superficial-heat-dissipation biomimetic strategies. Two case studies, a base case and a proposed case, were evaluated using the Designbuilder software through dynamic simulation. The proposed case is based on a combined biomimetic strategy; the reflective characteristics of the Saharan ant applied as a coating on the roofs through a segmented pattern such as the Zebra’s stripes (one section with coating, and another without). Results showed that the OP decreased from 8 to 10 °C for the entire urban zone throughout the year. A reduction of 3.13% corresponding to 8790 kWh per year was achieved for cooling energy consumption. A difference of 5 °C in external surface temperature was obtained, having a lower temperature in which the biomimetic strategy was applied. Besides, it was evidenced that a contrasted-reflectivity-stripes pitched roof performed better than a fully reflective roof. Thus, the functionality of Zebra stripes, together with the reflective characteristics of the Saharan ant, provide better performance for buildings’ thermal regulation and energy needs for cooling.


Sign in / Sign up

Export Citation Format

Share Document