scholarly journals Effect of Resin Coating on Surface Roughness and Microhardness of High Viscous Glass Ionomer Cements

2021 ◽  
Vol 16 (2) ◽  
pp. 209-221
Author(s):  
Lee Jian Sheng ◽  
Chan Wen Ni ◽  
Noor Azlin Yahya ◽  
Ros Anita Omar

High viscous glass ionomer cement (HVGIC) was recently developed for atraumatic restorative treatment (ART). However, its moisture sensitivity remains a limitation thus protective coating application is recommended. This study investigated the effect of resin coating on the surface roughness and microhardness of two HVGICs (Riva Self Cure HVGIC [RV] and Equia® Forte Fil [EQ]) conditioned in food-simulating liquids (FSLs). Fifty standard disc-shaped samples were fabricated using customised stainless-steel mould (10 × 2 mm). Coating was applied on top surface of all samples and subsequently divided into five groups: air (control), distilled water, 0.02 N citric acid, heptane and 50% ethanol-water solution. The samples were conditioned in FSLs at 37°C for seven days. Subsequently, the surface roughness and microhardness of samples were measured using optical profilometry and microhardness tester, respectively. SEM analysis was done for qualitative observation of surface morphological changes. Data were analysed using one-way ANOVA, two-way ANOVA and posthoc Tukey’s test (α = 0.05). Interestingly, the results revealed that surface roughness was significantly influenced by FSLs immersion, presence of coating and the materials itself (p < 0.001). The lowest surface roughness was found on control coated samples: RV (50.98±4.25) nm and EQ (62.77±3.92) nm, while the highest values seen on uncoated surfaces in citric acid: RV (505.26±31.10) nm and EQ (350.33±15.36) nm. RV samples had the lowest microhardness of 54.97±2.48 Vickers hardness number (VHN) post-immersion in citric acid. In conclusion, with the exception of RV conditioned in heptane and ethanol, the uncoated HVGICs generally had higher surface roughness than the coated HVGICs. HVGICs conditioned in citric acid showed the most significant increase in surface roughness and reduction in microhardness.

2019 ◽  
Vol 8 (1) ◽  
pp. 7
Author(s):  
Michael William Handoko ◽  
Rosalina Tjandrawinata

One of the restorative dental materials that is continuously developed is Glass Ionomer Cement (GIC). The aim of this research is to know whether there is influence of nanofilled resin coating application on GIC to reduce surface roughness. In this study GIC type II (EQUIA Forte, GC, Japan) was used to be mechanically manipulated and inserted into a mold which produced a sample of 6.0±0.3 mm in diameter and 3.0±0.2 mm in height. GIC samples were divided into 2 groups namely 10 GIC samples were not coated with nanofilled resin coating as control group and 10 GIC samples were coated with nanofilled resin coating as treatment group. GIC samples were tested immediately and then immersed in sterile distilled water in a 37°C incubator. After 24 hours, GIC samples were surface roughness tested using a Surface Roughness Tester. Then all samples were brushed using a soft bristle mechanical tooth brush for 1 hour. After brushing, the sample is tested for final surface roughness. The results showed an increase in surface roughness in non-coated group/control (0.005 ± 0,328mm) and coated group (0.015±0.240 mm). Statistical data analysis using unpaired t test showed that there was no significant difference (p>0.05) in the increasing of surface roughness between control group and treatment group. It can be concluded that application of nanofilled resin coating to GIC cannot reduce the roughness of GIC surface.


2006 ◽  
Vol 17 (2) ◽  
pp. 106-109 ◽  
Author(s):  
Renata Cristiane da Silva ◽  
Angela Cristina Cilense Zuanon

The purpose of this study was to evaluate the surface roughness of four conventional chemically cured glass ionomer cements (Fuji IX, Ketac Molar, Vidrion R and Vitromolar) commonly used in atraumatic restorative treatment (ART) immediately after material preparation. Twenty specimens of each glass ionomer cement were fabricated and surface roughness was measured after material setting. The specimens were further examined under scanning electron microscopy. Data were analyzed statistically by Kruskal-Wallis test and Mann-Whitney test at 5% significance level. Two-by-two comparisons showed statistically significant difference (p<0.05) between all materials, except for Ketac Molar and Vidrion R, which had statically similar results (p>0.05). Regarding their results of surface roughness, the materials can be presented in a crescent order, as follows: Ketac Molar < Vidrion R < Fuji IX < Vitromolar. In conclusion, from the tested glass ionomer cements, Fuji IX, Ketac Molar and Vidrion R presented acceptable surface roughness after setting reaction while Vitromolar showed remarkably higher surface roughness.


2017 ◽  
Vol 25 (5) ◽  
pp. 541-550 ◽  
Author(s):  
Cristiane Duque ◽  
Kelly Limi Aida ◽  
Jesse Augusto Pereira ◽  
Gláucia Schuindt Teixeira ◽  
Angela Scarparo Caldo-Teixeira ◽  
...  

2004 ◽  
Vol 12 (4) ◽  
pp. 344-348 ◽  
Author(s):  
Eduardo Bresciani ◽  
Terezinha de Jesus Esteves Barata ◽  
Ticiane Cestari Fagundes ◽  
Akimi Adachi ◽  
Marina Martins Terrin ◽  
...  

The aim of this study was to compare, in different periods of time, the compressive and diametral tensile strength of a traditional high viscous glass ionomer cement: Fuji IX (GC Corporation), with two new Brazilian GIC's: Vitro-Molar (DFL) and Bioglass R (Biodinamica), all indicated for the Atraumatic Restorative Treatment (ART) technique. Fifteen disk specimens (6.0mm diameter x 3.0mm height) for the diametral tensile strength (DTS) test and fifteen cylindrical specimens (6.0mm diameter x 12.0mm height) for the compressive strength (CS) test were made of each GIC. Specimens were stored in deionized water at 37º C and 100% of humidity in a stove until testing. Five specimens of each GIC were submitted to CS and DTS test in each period, namely 1 hour, 24 hours and 7 days. The specimens were tested in a testing machine (Emic) at a crosshead speed of 1.0mm/min for CS and 0.5mm/min for the DTS test until failure occurred. The data were submitted to two-way ANOVA and Tukey tests (alpha=0.05). The mean CS values ranged from 42.03 to 155.47MPa and means DTS from 5.54 to 13.72 MPa, with test periods from 1h to 7 days. The CS and DTS tests showed no statistically significant difference between Fuji IX and Vitro Molar, except for CS test at 1-hour period. Bioglass R had lowest mean value for CS of the cements tested. In DTS test Bioglass R presented no statistically significant differences when compared with all others tested GICs at 1-hour period and Bioglass R presented no difference at 24-hour and 7-day periods when compared to Vitro-Molar. Further studies to investigate other physical properties such as fracture toughness and wear resistance, as well as chemical composition and biocompatibility, are now needed to better understand the properties of these new Brazilian GIC's.


2009 ◽  
Vol 56 (2) ◽  
pp. 78-85 ◽  
Author(s):  
Lado Davidovic ◽  
Slavoljub Tomic ◽  
Mihael Stanojevic ◽  
Slavoljub Zivkovic

Introduction. A lack of appropriate adhesiveness is one of the biggest problems in the restorative dentistry today and the main cause of the microleakage between restorations and hard dental tissue. The aim of this study was to assess the adhesiveness of two different glass ionomer cement restorations class V on the hard dental tissue using the SEM analysis and dye penetration test. Material and methods. The study included 80 extracted teeth for orthodontic reasons (premolars and molars) in both genders and different age. On the vestibular and oral side of the teeth, adhesive preparations class V were done (size 3?2?2 mm). On the vestibular preparation, GC Fuji II was applicated and GC Fuji II LC-improved on the oral side. The quality of the adhesiveness between restorations and hard dental tissue was evaluated using the SEM analysis and dye penetration test (0.5% basic fuxsin). Linear penetration of the dye was observed using 10 times magnification. Results. The results showed that microleakage was presented with both materials but a ratio was less with Fuji II LC compared with Fuji II. Also, the microleakage was less on the occlusal parts of the restorations than on the gingival, with both materials. Microleakage was noticed in 93.44% teeth with Fuji II GJC restorations with index of microleakage of 148 on all edges. Fuji II LC GJC restorations showed microleakage in 68.4% teeth with index of microleakage 75 on all edges. The SEM analysis showed that both glass ionomer materials had better adhesiveness to the enamel than to the dentin. The average gap length between Fuji II LC and dentin was 9 ?m and Fuji II 17 ?m, respectively. Conclusion. Better adhesiveness to the hard dental tissue was achieved with materials of the newer generations, resin modificated glas ionomer cements.


2020 ◽  
Vol 44 (5) ◽  
pp. 342-347
Author(s):  
Natyla ML Silva ◽  
Victor G Costa ◽  
Letícia M Gonçalves ◽  
Isabella A Gomes ◽  
Marco Aurélio B Paschoal

Objective: The present study investigated the erosive potential of children’s mouthrinses on glass ionomer cement (GIC) samples after simulated toothbrushing. Study design: Forty round-shaped samples of GIC were divided into 3 groups: G1- cetylpyridinium chloride, G2- xylitol and triclosan and G3–Malva sylvestris and xylitol and G4–distilled water as a control group. Prior to the main tests, the samples were submitted to the surface roughness measurement (Ra) and weight analysis (W). Afterward, they were brushed twice day (2× / day) for 15 days and immersed in mouthrinses after the last daily brushing. The final surface roughness (R2) and weight (W2) were determined after completing the tooth brushing-mouth rinsing cycles and the real increase in roughness (ΔRa) and real weight loss (ΔW) were calculated. In addition, stereoscopic images taken at 30× magnification. The data was analyzed by one-way ANOVA and Tukey-test post hoc tests for intergroup comparison and the T-test for dependent samples (α = 0.05). Results: Only group G2 showed increased in roughness ΔRa (1.53 ± 0.94) whereas ΔW values were not significant. However, evident cracks and voids were verified for all tested children’s rinses. Conclusion: Thus, children’s mouthrinse containing xylitol / triclosan increased the GIC roughness, especially when associated with brushing.


2010 ◽  
Vol 35 (6) ◽  
pp. 634-640 ◽  
Author(s):  
H. Yu ◽  
Q. Li ◽  
T. Attin ◽  
Y. Wang

Clinical Relevance Carbamide peroxide treatment increased the microleakage of Class V conventional glass-ionomer cement and resin modified glass-ionomer cement restorations. The resin coating is an effective method to avoid bleaching-induced microleakage without affecting the bleaching outcome.


2017 ◽  
Vol 15 (3) ◽  
pp. 185
Author(s):  
Dilcele Silva Moreira Dziedzic ◽  
Lucia Helena Ramos da Silva ◽  
Bruna Luiza do Nascimento ◽  
Marina Samara Baechtold ◽  
Gisele Maria Correr ◽  
...  

Aim: This study investigated the effect of an in-office bleaching technique on lightness, color and surface roughness of two commercially available materials: a resin-modified glass-ionomer cement and a nanohybrid resin composite. Methods: Twelve disk-shaped specimens were prepared with both materials. The samples were bleached with 35% hydrogen peroxide. Bleaching was tested initially onto a smooth surface and later onto a polished one of the same specimens. The effect of the treatments on lightness and color was verified with a spectrophotometer. Surface roughness was measured with a digital surface roughness tester. The data were statistically analyzed by repeated measures ANOVA and post hoc Tukey’s test (alpha = 0.05). Results: Significant variation in lightness and color was observed on the resin-modified glass-ionomer cement after the first bleaching procedure. Roughness increased significantly only after polishing the resin-modified glass-ionomer cement surface. Composite color variation was evident in the last observation period, but roughness and lightness variation due to bleaching and polishing was not significant. Conclusion: The bleaching treatment caused significant color alterations on the materials tested. This study observed that the application of in-office bleaching onto the glass-ionomer cement promoted clinically observable color alteration, and polishing after bleaching is contraindicated for this material.


Author(s):  
Farahnaz Sharafeddin ◽  
Somaye Bahrani

Objectives: Glass ionomer cements (GICs) are among the most popular dental restorative materials, but their use is limited due to their clinical disadvantages. Many efforts have been made to improve the properties of these materials by adding various fillers. Incorporation of hydroxyapatite (HA) into the GICs is considered to improve the physical properties of restorations, and may prevent treatment failure. This study aimed to evaluate the surface roughness (Ra) of a conventional glass ionomer cement (CGIC), a resin-modified glass ionomer (RMGI) and a Zirconomer with and without micro-hydroxyapatite (µHA). Materials and Methods: This experimental study was conducted on 6 groups (n=10) including CGIC, CGIC + µHA, RMGI, RMGI + µHA, Zirconomer, and Zirconomer + µHA. A total of 60 disc-shaped samples (6 mm × 2 mm) were prepared in plastic molds and were stored in distilled water for 24 h. After polishing of the specimens, their Ra was measured by a profilometer in micrometers (µm). The data were analyzed using two and one-way ANOVA, Tukey's HSD test, and independent t-test. Results: Incorporation of µHA resulted in statistically significant differences in Ra between the study groups (P<0.05). Following the incorporation of µHA, the Ra significantly decreased in CGIC (P=0.013) and Zirconomer (P=0.003). However, addition of µHA to RMGI resulted in a significant increase in its Ra (P<0.001). Conclusion: Addition of µHA decreased the Ra of Zirconomer and CGIC, and increased the surface roughness of RMGI samples.


Sign in / Sign up

Export Citation Format

Share Document