Energy and process data processing and visualisation for optimising wastewater treatment plants

2015 ◽  
Vol 10 (1) ◽  
pp. 10-18 ◽  
Author(s):  
Christian M. Thürlimann ◽  
David J. Dürrenmatt ◽  
Kris Villez

For complex systems such as wastewater treatment plants (WWTPs), effective data communication is an important step to enable operators to assess their plant. However, examples in practice show that this step is insufficiently considered. In this article, we describe a fast, relevant, and intuitive decision-support tool for operators. We have developed a key performance indicator (KPI) visualisation tool for energy and process data embedded in a larger process optimisation software. The KPI set consists of indicator values relating to energy and effluent quality. In order to ensure that the visualisation tool will be used and cover the needs of the plant staff, we developed this part of the software in collaboration with two WWTPs. At the time of writing, the tool is used in the daily operation of both plants. The operators see the tool's most important advantages as its ability to quickly assess current plant performance and to simplify the tracking and analysis of inter- and intra-process relationships and dynamics.

2012 ◽  
Vol 12 (3) ◽  
pp. 372-386 ◽  
Author(s):  
C. Silva ◽  
P. Ramalho ◽  
S. Quadros ◽  
H. Alegre ◽  
M. J. Rosa

Performance assessment of water supply and wastewater services is today a major issue. Over the past six years, the National Civil Engineering Laboratory (Portugal) has been developing performance assessment systems for drinking water treatment plants (WTPs) and wastewater treatment plants (WWTPs). In 2009, a national field-test was launched in Portugal, ‘PASt21’, involving 27 plants (10 WTPs and 17 WWTPs). This paper presents an overview of the second generation of the performance indicator (PI) systems for the overall performance assessment of WTPs and WWTPs, the extent to which the systems were applied in the 5-year study period (2006–2010), and the aggregated results (average, median, percentiles 25 and 75, maximum and minimum) of representative PIs in each assessment group. It was concluded that all indicators are relevant, and the results show the ability of the proposed PI systems to assess the overall performance of a given treatment plant. The aggregated results are very important for the continuous improvement of the plant performance through benchmarking and periodic reassessment of targets.


1990 ◽  
Vol 22 (3-4) ◽  
pp. 65-72 ◽  
Author(s):  
H.-H. Schierup ◽  
H. Brix

Since 1983 approximately 150 full-scale emergent hydrophyte based wastewater treatment plants (reed beds) have been constructed in Denmark to serve small wastewater producers. The development of purification performance for 21 plants representing different soil types, vegetation, and hydraulic loading rates has been recorded. Cleaning efficiencies were typically in the range of 60-80% reduction for BOD, 25-50% reduction for total nitrogen, and 20-40% reduction for total phosphorus. The mean effluent BOD, total nitrogen and total phosphorus concentrations of the reed beds were 19 ± 10, 22 ± 9 and 6.7 ± 3.2 mg/l (mean ± SD), respectively. Thus, the general Danish effluent standards of 8 mg/l for N and 1.5 mg/l for P for sewage plants greater than 5,000 PE cannot be met by the present realised design of EHTS. The main problem observed in most systems is a poor development of horizontal hydraulic conductivity in the soil which results in surface run-off. Since the political demands for effluent quality will be more strict in the future, it is important to improve the performance of small decentral sewage treatment plants. On the basis of experiences from different types of macrophyte based and conventional low-technology wastewater treatment systems, a multi-stage system is suggested, consisting of sedimentation and sand filtration facilities followed by basins planted with emergent and submergent species of macrophytes and algal ponds.


1996 ◽  
Vol 33 (1) ◽  
pp. 81-87
Author(s):  
L. Van Vooren ◽  
P. Willems ◽  
J. P. Ottoy ◽  
G. C. Vansteenkiste ◽  
W. Verstraete

The use of an automatic on-line titration unit for monitoring the effluent quality of wastewater plants is presented. Buffer capacity curves of different effluent types were studied and validation results are presented for both domestic and industrial full-scale wastewater treatment plants. Ammonium and ortho-phosphate monitoring of the effluent were established by using a simple titration device, connected to a data-interpretation unit. The use of this sensor as the activator of an effluent quality proportional sampler is discussed.


1993 ◽  
Vol 28 (10) ◽  
pp. 33-41
Author(s):  
Jes la Cour Jansen ◽  
Bodil Mose Pedersen ◽  
Erik Moldt

Influent and effluent data from about 120 small wastewater treatment plants (100 - 2000 PE) have been collected and processed. Seven different types of plants are represented. The effluent quality and the treatment efficiency have been evaluated. The most common type of plant is mechanical/biological treatment plants. Some of them are nitrifying and some are also extended for chemical precipitation of phosphorus. Constructed wetlands and biological sandfilters are also represented among the small wastewater treatment plants.


2017 ◽  
Vol 76 (5) ◽  
pp. 1225-1233 ◽  
Author(s):  
M. Schäfer ◽  
I. Hobus ◽  
T. G. Schmitt

In the future, an additional potential of control reserve as well as storage capacities will be required to compensate fluctuating renewable energy availability. The operation of energy systems will change and flexibility in energy generation and consumption will rise to a valuable asset. Wastewater treatment plants (WWTPs) are capable of providing the flexibility needed, not only with their energy generators but also in terms of their energy consuming aggregates on the plant. To meet challenges of the future in regard to energy purchase and to participate in and contribute to such a volatile energy market, WWTPs have to reveal their energetic potential as a flexible service provider. Based on the evaluated literature and a detailed analysis of aggregates on a pilot WWTP an aggregate management has been developed to shift loads and provide a procedure to identify usable aggregates, characteristic values and control parameters to ensure effluent quality. The results show that WWTPs have a significant potential to provide energetic flexibility. Even for vulnerable components such as aeration systems, load-shifting is possible with appropriate control parameters and reasonable time slots without endangering system functionality.


2013 ◽  
Vol 67 (7) ◽  
pp. 1481-1489 ◽  
Author(s):  
R. Barat ◽  
J. Serralta ◽  
M. V. Ruano ◽  
E. Jiménez ◽  
J. Ribes ◽  
...  

This paper presents the plant-wide model Biological Nutrient Removal Model No. 2 (BNRM2). Since nitrite was not considered in the BNRM1, and this previous model also failed to accurately simulate the anaerobic digestion because precipitation processes were not considered, an extension of BNRM1 has been developed. This extension comprises all the components and processes required to simulate nitrogen removal via nitrite and the formation of the solids most likely to precipitate in anaerobic digesters. The solids considered in BNRM2 are: struvite, amorphous calcium phosphate, hidroxyapatite, newberite, vivianite, strengite, variscite, and calcium carbonate. With regard to nitrogen removal via nitrite, apart from nitrite oxidizing bacteria two groups of ammonium oxidizing organisms (AOO) have been considered since different sets of kinetic parameters have been reported for the AOO present in activated sludge systems and SHARON (Single reactor system for High activity Ammonium Removal Over Nitrite) reactors. Due to the new processes considered, BNRM2 allows an accurate prediction of wastewater treatment plant performance in wider environmental and operating conditions.


2011 ◽  
Vol 1 (1) ◽  
pp. 37-56 ◽  
Author(s):  
Sílvia C. Oliveira ◽  
Marcos von Sperling

This article analyses the performance of 166 wastewater treatment plants operating in Brazil, comprising six different treatment processes: septic tank + anaerobic filter, facultative pond, anaerobic pond + facultative pond, activated sludge, UASB reactors alone, UASB reactors followed by post-treatment. The study evaluates and compares the observed effluent quality and the removal efficiencies in terms of BOD, COD, TSS, TN, TP and FC with typical values reported in the technical literature. In view of the large performance variability observed, the existence of a relationship between design/operational parameters and treatment performance was investigated. From the results obtained, no consistent relationship between loading rates and effluent quality was found. The influence of loading rates differed from plant to plant, and the effluent quality was dictated by several combined factors related to design and operation.


1999 ◽  
Vol 40 (7) ◽  
pp. 55-65 ◽  
Author(s):  
Mohamed F. Hamoda ◽  
Ibrahim A. Al-Ghusain ◽  
Ahmed H. Hassan

Proper operation of municipal wastewater treatment plants is important in producing an effluent which meets quality requirements of regulatory agencies and in minimizing detrimental effects on the environment. This paper examined plant dynamics and modeling techniques with emphasis placed on the digital computing technology of Artificial Neural Networks (ANN). A backpropagation model was developed to model the municipal wastewater treatment plant at Ardiya, Kuwait City, Kuwait. Results obtained prove that Neural Networks present a versatile tool in modeling full-scale operational wastewater treatment plants and provide an alternative methodology for predicting the performance of treatment plants. The overall suspended solids (TSS) and organic pollutants (BOD) removal efficiencies achieved at Ardiya plant over a period of 16 months were 94.6 and 97.3 percent, respectively. Plant performance was adequately predicted using the backpropagation ANN model. The correlation coefficients between the predicted and actual effluent data using the best model was 0.72 for TSS compared to 0.74 for BOD. The best ANN structure does not necessarily mean the most number of hidden layers.


Sign in / Sign up

Export Citation Format

Share Document