scholarly journals In vitro Comparison of Apically Extruded Debris during Root Canal Retreatment with Rotary and Reciprocating Systems

2019 ◽  
Vol 13 (1) ◽  
pp. 488-492
Author(s):  
María J. Burbano Balseca ◽  
Silvana B. Terán Ayala ◽  
Fábio D. da Costa Aznar ◽  
Adriana R. de Freitas-Aznar ◽  
Guillermo M. Aguirre Balseca ◽  
...  

Introduction: The extrusion of apical detritus during the retracting procedure is very important, as, besides eliminating materials of radicular obturation, aggressive agents and products such as the remains of dentin taken out, and microorganisms are generally located in tissue around the roots, producing undesired effects, such as inflammation, acute pain, post-operatory pain and delays in the periapical treatment. Objective: To determine the amount of apically extruded detritus using rotary and reciprocating retreatment systems. Methodology: An experimental comparative study as conducted in which 40 single-rooted human first premolars were analyzed. The instruments used were ProTaper Universal files up to F3 and sodium hypochlorite, and the sealing was made through the hybrid technique Tager. They were then kept at 37ºC and 100% of humidity for 15 days so that the sealing material would seal. For the retracting procedure, experimental tubes previously weighted were used. The sample was divided randomly into two groups of 20 pieces. Group A: ProTaper R, and group B: Reciproc. Then, the irrigating material (distilled water) was evaporated from the tubes for 12 hours in a stove at 105ºC, and the experimental tubes were weighted in an analytical precision weighing scale 10-5g. The data was analyzed through the T Student with a significance level of 5%. Results: Results indicated that groups A and B, retreatment with rotational ProTaper R and reciprocating retreatment system (Reciproc) showed a similar difference of initial and final weights, indicating similar apical extrusion of detritus. Conclusion: Both systems extruded a similar amount of detritus during the retreatment procedures.

2020 ◽  
Vol 10 (16) ◽  
pp. 5684 ◽  
Author(s):  
Ajinkya M. Pawar ◽  
Bhaggyashri A. Pawar ◽  
Anuj Bhardwaj ◽  
Alexander Maniangat Luke ◽  
Zvi Metzger ◽  
...  

Apical extrusion of debris (AED) by the full sequence of the self-adjusting file (SAF) system was compared with that of the XP-endo shaper plus sequence. Sixty permanent mandibular incisors were randomly assigned to two groups (n = 30) for root canal instrumentation: Group A: Stage 1—pre-SAF OS, pre-SAF 1 and pre-SAF 2 files, followed by Stage 2—1.5 mm SAF; and Group B: Stage 1— hand K-file 15/0.02, followed by Stage 2—XP-endo shaper and Stage 3—XP-endo finisher. The AED produced during instrumentation at each stage was collected in pre-weighed Eppendorf tubes. The weights of AED by the two methods were compared using t tests with significance level set at 5%. Group A produced significantly less total AED than Group B (p < 0.001), with no significant difference in debris extrusion between the two stages (p = 0.3014). Conversely, in Group B, a significant difference was noted between Stage 1 and Stages 2 and 3 (p < 0.01), with no significant difference between Stages 2 and 3 (p = 0.488). Both sequences resulted in measurable amounts of AED. Each phase, in either procedure, made its own contribution to the extrusion of debris.


2020 ◽  
Vol 7 (3) ◽  
pp. 3678-3685
Author(s):  
Soghra Rabiei ◽  
Mahnaz Yavangi ◽  
Marzieh Farimani ◽  
Iraj Amiri ◽  
Mohamad Fallah ◽  
...  

Introduction: One of the remaining challenges in assisted reproductive procedures, especially in vitro fertilization (IVF), is proper embryo transfer. The aim of this clinical trial was to compare IVFembryo transfer outcome by two types of soft embryo transfer catheters in Hamadan Endometrics and Endometriosis Research Center (Iran). Methods: In this clinical trial study, 100 patients who were candidates for IVF were evaluated. Patients were randomly assigned into two groups (A=50 and B=50). The IVF was identical for both groups until the embryo transfer stage. For group A, soft catheter CH3 PM TRANS SET MINI was used and in group B, KITAZATO soft catheter was used for embryo transfer. All transfers were performed by one person. Patients were recruited using checklists, demographic information, infertility history, beta-human chorionic gonadotropin (ß-hCG) serum levels at day 14 post-transfer, and pregnancy bag 28 days after transfer. The results were analyzed by SPSS software version 16 and using descriptive statistics, chi-square and t-test. The significance level was < 0.05. Results: The mean age of group A and group B was 30.12 and 29.24 years, respectively (p=0.341). The mean duration of infertility in both groups was not statistically significant, and in groups A and B were 4.89 and 4 years, respectively. Ninety % of group A experienced their first IVF experience, while in group B it was slightly lower than 86%, which was not statistically significant. The mean number of eggs obtained in group A was 9.84 and in the group B was 9.88 (p=0.962). The mean number of embryos formed in group A was 6.24 and in group B was 5.72 (p=0.405). There was no statistically significant difference between the two groups in using of Tenaculum, the quality of transmission, and the contamination of the catheter head into the blood or mucus. Conclusion: According to the findings of the present study, the use of KITAZATO catheter compared to PM TRANS SET MINI CH3 catheter for fetal transfer in IVF patients showed no significant difference in pregnancy success rate. However, patients who received the KITAZATO catheter had a slightly higher chance of pregnancy that could be clinically valuable.  


1982 ◽  
Vol 47 (03) ◽  
pp. 218-220 ◽  
Author(s):  
P Sié ◽  
E Letrenne ◽  
C Caranobe ◽  
M Genestal ◽  
B Cathala ◽  
...  

SummaryIn order to detect impaired synthesis of blood coagulation factors associated to consumption coagulopathy, a simultaneous evaluation of factor II-related antigen (II rAg) and of antithrombin III (AT III) was carried out in 16 patients affected with severe defibrination. An in vitro preliminary study on plasma and serum demonstrated that the levels of II rAg and of AT III, assessed by the Laurell technique with Behring antisera, were not reduced by the coagulation process. The patients were, a posteriori, classified into two groups according to the absence (group A) or the presence (group B) of factors predisposing to liver failure such as metastasis, cirrhosis, and prolonged shock. II rAg and AT III levels are significantly correlated; they are in the normal range in group A but reduced in group B. Thus II rAg or AT III level determinations are useful markers in the detection of liver failure associated to the consumption phenomenon. These results also suggest that part of the decreased AT III levels reported in severe cases of disseminated intravascular coagulation may be the consequence of an associated liver failure.


2018 ◽  
Vol 2018 ◽  
pp. 1-8
Author(s):  
Xiao-yu Liu ◽  
Hai-feng Shi ◽  
Jie Zheng ◽  
Ku-lin Li ◽  
Xiao-xi Zhao ◽  
...  

Objective. The objective of this study was to investigate the impact of left atrial (LA) size for the ablation of atrial fibrillation (AF) using remote magnetic navigation (RMN). Methods. A total of 165 patients with AF who underwent catheter ablation using RMN were included. The patients were divided into two groups based on LA diameter. Eighty-three patients had small LA (diameter <40 mm; Group A), and 82 patients had a large LA (diameter ≥40 mm; Group B). Results. During mapping and ablation, X-ray time (37.0 (99.0) s vs. 12 (30.1) s, P<0.001) and X-ray dose (1.4 (2.7) gy·cm2 vs. 0.7 (2.1) gy·cm2, P=0.013) were significantly higher in Group A. No serious complications occurred in any of the patients. There was no statistical difference in the rate of first anatomical attempt of pulmonary vein isolation between the two groups (71.1% vs. 57.3%, P=0.065). However, compared with Group B, the rate of sinus rhythm was higher (77.1% vs. 58.5%, P<0.001) during the follow-up period. More patients in Group A required a sheath adjustment (47/83 vs. 21/82, P<0.001), presumably due to less magnets positioned outside of the sheath. In vitro experiments with the RMN catheter demonstrated that only one magnet exposed created the sheath affects which influenced the flexibility of the catheter. Conclusions. AF ablation using RMN is safe and effective in both small and large LA patients. Patients with small LA may pose a greater difficulty when using RMN which may be attributed to the fewer magnets beyond the sheath. As a result, the exposure of radiation was increased. This study found that having at least two magnets of the catheter positioned outside of the sheath can ensure an appropriate flexibility of the catheter.


1990 ◽  
Vol 2 (4) ◽  
pp. 351 ◽  
Author(s):  
YF Wong ◽  
EP Loong ◽  
KR Mao ◽  
PP Tam ◽  
NS Panesar ◽  
...  

Salivary oestradiol (E2) and progesterone (P) levels have been shown to reflect the biologically active fractions in the serum. The luteal-phase status of stimulated cycles was investigated after in vitro fertilization and embryo transfer (IVF-ET). Thirty patients were randomly allocated to one of three luteal therapy groups: group A had no support, group B had intramuscular P and group C had intramuscular P and human chorionic gonadotrophin (hCG). One pregnancy was achieved in group A, two in group B and three in group C. Significant correlations between salivary and serum levels of E2 and of P in matched samples during luteal phase were found. Salivary E2 levels from luteal day 8 through day 14 and P levels from day 3 through day 14 were significantly higher in the pregnant than in the nonpregnant cycles. Among the nonpregnant cycles, salivary E2 and P levels were significantly higher in group C than in group A or B. These findings suggest that, in stimulated cycles for IVF-ET, determination of salivary E2 and P levels may be used as reliable alternatives to serum concentrations for assessing the luteal phase. Also, the additional hCG has an enhanced luteotrophic effect, as reflected by the higher salivary E2 and P levels, which may lead to a better pregnancy rate.


2014 ◽  
Vol 490-491 ◽  
pp. 867-871
Author(s):  
Guo Hui Wang ◽  
Wei Yi Chen

To understand the effect of mechanical stimulation on posterior sclera reinforcement (PSR), the rabbit scleral fibroblasts after PSR were subjected to stretch in vitro and MMP-2 and TIMP-2 expression of scleral fibroblasts were evaluated. Three-week-old rabbits were monocularly performed by eyelid suturation randomly to prepare experimental myopia eye. After 60 days, the experimental myopia eyes were treated by PSR. After 6 months, the posterior pole scleral fibroblasts (normal sclera - group A, sclera after operation - group B and fusion region of sclera and reinforcing band group C) were isolated and cultured in vitro. The cells were subjected to cyclic stretch regimens (sine wave, 3% and 6% elongation amplitude, 0.1Hz, 48h duration) by FX-4000 Tension System. The MMP-2 and TIMP-2 expression of scleral fibroblasts were evaluated by ELISA method. The results show that after cyclic stretch to the scleral fibroblasts of the normal sclera and the sclera after operation, the MMP-2 expression was significantly reduced and the TIMP-2 expression was significantly increased, the MMP-2 and TIMP-2 expression of the scleral fibroblasts of the fusion region after operation was no changed. It was indicated that the mechanical stimulation could regulate the MMP-2 and TIMP-2 expression of scleral fibroblasts and play an important role in the process of treating high myopia with PSR surgery.


2021 ◽  
Vol 45 (5) ◽  
pp. 312-316
Author(s):  
Mishra Neha Sanjeev ◽  
Harsimran Kaur ◽  
Sandeep Singh Mayall ◽  
Rishika ◽  
Ramakrishna Yeluri

Objective: To evaluate the effectiveness of placing a resorbable collagen barrier in impeding the extrusion of obturation material in primary molars undergoing resorption. Study design: All the 94 canals in 47 mandibular molars were allocated to 2 groups- Group ‘A’- 47 canals with collagen barrier (Test group) and Group ‘B’- 47 canals without collagen barrier (Control group) based on randomization protocol. Pulpectomy was performed and obturation of both test and control canals were radiographically assessed. Pearson’s chi – square test was applied to analyze the results. The significance level was predetermined at p &lt; 0.05. Results: Among the test group, 93.6% of the canals showed no extrusion while, 6.4% showed visible extrusion of the material outside the apex. In the control group, 83% showed no extrusion whereas 17% of the canals showed visible extrusion outside the apex. But no significant difference was noted (p&gt;0.05). Conclusion: The placement of resorbable collagen barrier in the apical third of the canal prevented the extrusion of obturating material beyond the apex in resorbing primary molars.


2018 ◽  
Vol 47 (1) ◽  
pp. 212-221 ◽  
Author(s):  
Cecilia Pascual-Garrido ◽  
Elizabeth A. Aisenbrey ◽  
Francisco Rodriguez-Fontan ◽  
Karin A. Payne ◽  
Stephanie J. Bryant ◽  
...  

Background: In this study, we investigate the in vitro and in vivo chondrogenic capacity of a novel photopolymerizable cartilage mimetic hydrogel, enhanced with extracellular matrix analogs, for cartilage regeneration. Purpose: To (1) determine whether mesenchymal stem cells (MSCs) embedded in a novel cartilage mimetic hydrogel support in vitro chondrogenesis, (2) demonstrate that the proposed hydrogel can be delivered in situ in a critical chondral defect in a rabbit model, and (3) determine whether the hydrogel with or without MSCs supports in vivo chondrogenesis in a critical chondral defect. Study Design: Controlled laboratory study. Methods: Rabbit bone marrow–derived MSCs were isolated, expanded, encapsulated in the hydrogel, and cultured in chondrogenic differentiation medium for 9 weeks. Compressive modulus was evaluated at day 1 and at weeks 3, 6, and 9. Chondrogenic differentiation was investigated via quantitative polymerase reaction, safranin-O staining, and immunofluorescence. In vivo, a 3 mm–wide × 2-mm-deep chondral defect was created bilaterally on the knee trochlea of 10 rabbits. Each animal had 1 defect randomly assigned to be treated with hydrogel with or without MSCs, and the contralateral knee was left untreated. Hence, each rabbit served as its own matched control. Three groups were established: group A, hydrogel (n = 5); group B, hydrogel with MSCs (n = 5); and group C, control (n = 10). Repair tissue was evaluated at 6 months after intervention. Results: In vitro, chondrogenesis and the degradable behavior of the hydrogel by MSCs were confirmed. In vivo, the hydrogel could be delivered intraoperatively in a sterile manner. Overall, the hydrogel group had the highest scores on the modified O’Driscoll scoring system (group A, 17.4 ± 4.7; group B, 13 ± 3; group C, 16.7 ± 2.9) ( P = .11) and showed higher safranin-O staining (group A, 49.4% ± 20%; group B, 25.8% ± 16.4%; group C, 36.9% ± 25.2%) ( P = .27), although significance was not detected for either parameter. Conclusion: This study provides the first evidence of the ability to photopolymerize this novel hydrogel in situ and assess its ability to provide chondrogenic cues for cartilage repair in a small animal model. In vitro chondrogenesis was evident when MSCs were encapsulated in the hydrogel. Clinical Relevance: Cartilage mimetic hydrogel may offer a tissue engineering approach for the treatment of osteochondral lesions.


2016 ◽  
Vol 6 (1) ◽  
pp. 19-23
Author(s):  
Amol Mhatre ◽  
VK Ravindranath ◽  
Sachin Doshi ◽  
Girish Karandikar ◽  
PS Vivek

ABSTRACT Aim The aim of this in vitro study was to investigate the efficiency of the new generation of elastomeric ligatures with innovative designs (SlideTM and AlastiKTM Easy-to-Tie) in reducing frictional resistance (FR) during sliding mechanics as compared with conventional ligatures. Materials and Methods Sixty ligature samples divided into four groups were used for the study. Group A: QuiK-StiK™ (3M Unitek, Monrovia, CA, USA), Group B: AlastiK™ Easy-to-Tie (3M Unitek, Monrovia, CA, USA), Group C: Slide™ (Leone, Firenze, Italy), and Group D: SS ligatures 0.010” (Libral Traders, New Delhi, India). Universal Testing Machine, Instron was used for measuring FR at the bracket-wire interface. Results There was statistically significant difference in FR among all the four groups of ligatures tested (p < 0.001). Slide ligatures produced the least amount of FR followed by SS ligatures, Easy-to-Tie, and QuiK-StiK in the increasing order of the FR values registered. Conclusion SlideTM ligatures may represent a valid alternative to passive self-ligating brackets when minimal amount of friction is desired. Angulation introduced into the elastomeric ligatures reduces the friction in comparison to conventional elastomeric ligatures. How to cite this article Vivek PS, Ravindranath VK, Karandikar G, Doshi S, Mhatre A, Sonawane M. Frictional Characteristics of the Newer Low-friction Elastomeric Ligatures. J Contemp Dent 2016;6(1):19-23.


2019 ◽  
Vol 17 (1) ◽  
pp. 228080001881601
Author(s):  
Filiberto Mastrangelo ◽  
Isabella Perraro ◽  
Sabrina Mattia ◽  
Giuseppe Troiano ◽  
Khrystyna Zhurakivska ◽  
...  

Introduction: The technique of sealing is a widely accepted procedure for prevention of caries. The aim of our in vitro study was to compare the effect of two different curing units (traditional LED source and innovative laser diode lamp) on the integrity of fissure sealant material and its interface with tooth enamel. Materials and methods: Sixty healthy third molars were randomly assigned to two groups. In group A were teeth intended for polymerization by LED B lamp, and group B comprised teeth to be polymerized by an innovative laser diode. Both groups were treated with the traditional sealing technique, subjected to a metallization process, and analyzed by scanning electron microscope. Results: Micro-gaps between the sealant and the enamel were found in specimens in both A (43%) and B (40%) groups ( p=0.793), and sealant shrinkage was seen. Significant differences between the groups emerged in the percentage of perimetric micro-erosion sites (80% vs. 100%, p=0.010) and the presence of holes and micro-bubbles on the sealant surface (21% vs. 63%, p=0.001). Conclusions: Although macroscopic clinical polymerization occurred with both instruments, the microscopic evaluation showed significant differences between the studied groups in terms of perimetric micro-erosion sites and micro-bubbles, which were higher in laser-cured samples.