CT time-attenuation washout curves of adrenal adenomas and nonadenomas.

1998 ◽  
Vol 170 (3) ◽  
pp. 747-752 ◽  
Author(s):  
M Korobkin ◽  
F J Brodeur ◽  
I R Francis ◽  
L E Quint ◽  
N R Dunnick ◽  
...  
Keyword(s):  
1979 ◽  
Vol 18 (06) ◽  
pp. 290-292 ◽  
Author(s):  
R. Lahtinen ◽  
T. Lahtinen

SummaryA l33Xe washout method has been used for measuring changes of blood flow in the proximal femur of a patient with the blastic crisis of chronic granulocytic leukaemia. In the hyperplastic phase the blood flow was highly increased and over three times greater than in the hypoplastic phase of the disease and over thirteen times greater than the value in normal bone. The bone circulation and especially the first component of the two-exponential bone washout curves appeared to reflect cell proliferation and neoplastic activity of the whole bone marrow. The method may provide clinically important information in the follow-up of selected haematological diseases.


1975 ◽  
Vol 38 (2) ◽  
pp. 228-235 ◽  
Author(s):  
M. Demedts ◽  
J. Clement ◽  
D. C. Stanescu ◽  
K. P. van de Woestijne

In 20 healthy subjects and 18 patients with bronchial obstruction, closing volume (CV) on single-breath nitrogen washout curves and inflection point (IP) on transpulmonary pressure-volume curves were recorded simultaneously during slow expiratory vital capacity maneuvers. IP and CV did not occur at identical lung volumes, IP being systematically larger than CV for small CV values. This discrepancy could not be attributed to an esophageal or mediastinal artifact. It is suggested that, though CV and IP both express “airway closure,” their sensitivity to closure may differ: CV underestimates closure because of a dead space effect; the latter may vary individually. On the other hand, IP may not reflect the true beginning of closure, particularly when it occurs at higher lung volumes.


1989 ◽  
Vol 9 (6) ◽  
pp. 886-891 ◽  
Author(s):  
David Barranco ◽  
Leslie N. Sutton ◽  
Sandra Florin ◽  
Joel Greenberg ◽  
Teresa Sinnwell ◽  
...  

19F NMR was used to determine washout curves of an inert, diffusible gas (CHF3) from the cat brain. The cerebral blood flow was estimated from a bi- or tri-phasic fit to the deconvoluted wash-out curve, using the Kety-Schmidt approach. Cerebral blood flow values determined by 19F NMR show the expected responsiveness to alterations in Paco2, but are approximately 28% lower than cerebral blood flow values determined simultaneously by radioactive microsphere techniques. High concentrations of CHF3 have little effect on intracranial pressure, mean arterial blood pressure or Paco2, but cause small changes in the blood flow to certain regions of the brain. We conclude that 19F NMR techniques utilizing low concentrations of CHF3 have potential for the noninvasive measurement of cerebral blood flow.


1964 ◽  
Vol 206 (4) ◽  
pp. 887-890 ◽  
Author(s):  
S. F. Sullivan ◽  
R. W. Patterson ◽  
E. M. Papper

Carbon dioxide washout curves were determined in hyperventilated dogs. Direct measurement of mixed venous carbon dioxide tension allowed calculation of changes in whole-body CO2 stores. The average whole-body CO2 dissociation constant in ten studies was 3.73 ml/kg mm. The limiting factor in reaching a new steady-state value was represented by a slow compartment in the washout curve. The average rate constant for this compartment was 0.062 min–1. The slowest compartment in this analysis has a 98% change in 1 hr, therefore the experimentally determined whole-body dissociation constant should closely approximate actual changes in tissue CO2 stores, excluding bone and fat.


1985 ◽  
Vol 59 (4) ◽  
pp. 1137-1144 ◽  
Author(s):  
R. Kraemer ◽  
B. Meister

To apply real-time moment-ratio analysis to multibreath N2-washout curves (MBNW) from children, a new processor-controlled device was constructed. Flow and fractional N2 concentration (FN2) were each sampled by 200 Hz. An electromagnetic triple-valve system, with an instrumental dead space of 36 ml and a valve resistance of 0.3 cmH2O . l-1 . s, was connected in series with a pneumotachograph and an N2 analyzer (Ohio 720) placed next to the mouthpiece. A FORTRAN/MACRO program on a PDP 11/23 computer enabled measurement of inspiratory and expiratory flow and FN2 sampling by a 12-bit analog-to-digital converter. The fast real-time digital processing of the N2 and flow signals incorporated filtering, delay compensation, and corrections for the effects of changes in gas composition and temperature. MBNW dynamics of the lungs were studied in 17 healthy and 28 asthmatic children and in 16 patients with cystic fibrosis, evaluating the moment ratios of the washout curves as indices of the ventilation characteristics. Intrasubject variability of the moment ratios (m1/m0, m2/m0) and determination of functional residual capacity (FRC) varied between 6.3 and 14.7% (depending on which parameter is considered) and was comparatively lower than other indices previously investigated in adults. In addition, the sensitivity of the moment ratios for discriminating different stages of ventilation inhomogeneity was superior to other indices. m2/m0 is closely related to the simultaneously measured airway resistance, and the ratio between cumulative expired volume and FRC is correlated with the ratio between residual volume and total lung capacity.


2012 ◽  
Vol 302 (2) ◽  
pp. H391-H401 ◽  
Author(s):  
Tine V. Karlsen ◽  
Emmet McCormack ◽  
Maja Mujic ◽  
Olav Tenstad ◽  
Helge Wiig

There is a lack of available methods to noninvasively quantify lymphatic function in small experimental animals, a necessity for studies on lymphatic system pathophysiology. We present a new method to quantify lymph flow in mice and rats, based on optically monitoring the depot clearance of near-infrared fluorescently labeled albumin and subsequent calculation of removal rate constants ( k). BSA was conjugated with Alexa680 NHS ester and remained stable in protein-rich solutions without free dye dissociation. To assess lymph flow, mice or rats were imaged every 30 or 60 min during a 3- to 6-h period following an intradermal injection of 0.5 or 1 μl Alexa680-albumin. Mice were awake between measurements, whereas rats were anesthetized throughout the experiment. The k, a parameter defined as equivalent to lymph flow, was calculated from the slopes of the resultant log-linear washout curves and averaged −0.40 ± 0.03 and −0.30 ± 0.02%/min for control C57BL/6 and C3H mice, respectively. Local administration of the vasoconstrictor endothelin-1 in mice led to a significant reduction in k, whereas overhydration in rats increased k, reflecting the coupling between capillary filtration and lymph flow. Furthermore, k was 50% of wild type in lymphedema Chy mice where dermal lymphatics are absent. We conclude that lymph flow can be determined as its rate constant k by optical imaging of depot clearance of submicroliter amounts of Alexa680-albumin. The method offers a minimally invasive, reproducible, and simple alternative to assess lymphatic function in mice and rats.


1980 ◽  
Vol 48 (2) ◽  
pp. 265-272 ◽  
Author(s):  
R. W. Light ◽  
R. B. George ◽  
G. R. Meneely ◽  
L. J. Chouest ◽  
R. H. Rosekrans

Multiple-breath nitrogen washout (MBNW) curves from 39 normal and 45 patients with varying degrees of airway obstruction were analyzed with the following equation: log log [(F0N2 - F infinity N2)/(FN2 - F infinity N2)] = B log (V/FRC) +A, where F0N2 is the initial, F infinity N2 is the equilibrium, and FN2 is the end-tidal fractional nitrogen concentration after a volume (V) of air in liters have been exchanged, and FRC is the measured functional residual capacity of the individual. All 84 curves were well described with the equation when all points corresponding to FN2 below 0.40 were used. The coefficient of determination (r2) exceeded 0.990 in 56/84 (67%) of the transformed curves and the lowest coefficient of determination was 0.946. This suggests that the MBNW can be described by two numbers, B called the index of uniformity, and A the index of efficiency. The ability of these two indices and the lung clearance index (LCI) to identify individuals as abnormal and to separate groups with varying degrees of airway obstruction was compared. B identified more individuals (33/45) as abnormal than did A(15/45) or LCI (19/45). B was also superior to A or LCI in separating groups with varying degrees of airway obstruction. This analysis allows the complex MBNW curve to be described by two numbers that vary depending on the degree of airway obstruction.


Sign in / Sign up

Export Citation Format

Share Document