scholarly journals Analysis of ceiling type to produce energy efficient residential buildings: case study on housing design of puskim pu-bandung city

2021 ◽  
Vol 11 (1) ◽  
pp. 36
Author(s):  
Nurina Vidya Ayuningtyas ◽  
Istiana Adianti ◽  
Jatmika Adi Suryabrata

Many houses that exist on this earth. Therefore, it is necessary to have tactical and intelligent thinking in designing a home. Many things are rarely considered related to the effects of the design of building elements when related to the temperature or the energy produced. Existing background regarding efforts to reach a comfortable temperature can not only be solved in terms of mechanical systems, but the architectural approach can help and provide a comfortable effect for its inhabitants. This research was conducted to determine the level of thermal comfort or temperature in the room of a residential design that would be related to the size of energy consumption by applying several alternative designs or ceiling forms. This type of research is research using simulation methods through a computer model. The results showed the use of ceiling type Vaulted Ceiling was able to increase the Surface Inside Temperature value by 3 ° C when compared to the type of drop ceiling. The Mean Radiant Temperature value when using the ceiling vault type rises 0.6 ° C and on the acquisition of Operative, Temperature rises 0.3 ° C. The use of insulation material on the roof can significantly reduce Mean Radiant Temperature and Operative Temperature at 1.7 ° C at Mean Radiant Temperature and 0.8 ° C at Operative Temperature. Seeing the results of the simulation in this study, the recommended ceiling type is to use the drop ceiling type because it is quite capable of keeping the temperature in the room not too high so that thermal comfort can be achieved. However, if you want to apply a ceiling design with a model or type of drop ceiling, it is better to use additional insulation material so that the heat transmission temperature is not too high in the room.

Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4530
Author(s):  
Youcef Bouzidi ◽  
Zoubayre El Akili ◽  
Antoine Gademer ◽  
Nacef Tazi ◽  
Adil Chahboun

This paper investigates adaptive thermal comfort during summer in medical residences that are located in the French city of Troyes and managed by the Association of Parents of Disabled Children (APEI). Thermal comfort in these buildings is evaluated using subjective measurements and objective physical parameters. The thermal sensations of respondents were determined by questionnaires, while thermal comfort was estimated using the predicted mean vote (PMV) model. Indoor environmental parameters (relative humidity, mean radiant temperature, air temperature, and air velocity) were measured using a thermal environment sensor during the summer period in July and August 2018. A good correlation was found between operative temperature, mean radiant temperature, and PMV. The neutral temperature was determined by linear regression analysis of the operative temperature and Fanger’s PMV model. The obtained neutral temperature is 23.7 °C. Based on the datasets and questionnaires, the adaptive coefficient α representing patients’ capacity to adapt to heat was found to be 1.261. A strong correlation was also observed between the sequential thermal index n(t) and the adaptive temperature. Finally, a new empirical model of adaptive temperature was developed using the data collected from a longitudinal survey in four residential buildings of APEI in summer, and the obtained adaptive temperature is 25.0 °C with upper and lower limits of 24.7 °C and 25.4 °C.


2014 ◽  
Vol 1041 ◽  
pp. 325-328
Author(s):  
Ferenc Kalmár ◽  
Tünde Kalmar

Energy saving is one of the main priorities in the building sector. In the last years in Hungary different national programs were launched in order to improve the thermal properties of residential buildings. In case of building refurbishment 40-60% heating energy savings were expected. There were cases when the expected energy savings have not been met. The aim of this research was to see which the refurbishment impact is on the thermal comfort in a residential building. It was found the mean radiant temperature, the operative temperature and the predicted mean vote (PMV) decrease after building refurbishment.


2021 ◽  
Vol 13 (8) ◽  
pp. 1443
Author(s):  
Maria Angela Dissegna ◽  
Tiangang Yin ◽  
Hao Wu ◽  
Nicolas Lauret ◽  
Shanshan Wei ◽  
...  

The microclimatic conditions of the urban environment influence significantly the thermal comfort of human beings. One of the main human biometeorology parameters of thermal comfort is the Mean Radiant Temperature (Tmrt), which quantifies effective radiative flux reaching a human body. Simulation tools have proven useful to analyze the radiative behavior of an urban space and its impact on the inhabitants. We present a new method to produce detailed modeling of Tmrt spatial distribution using the 3-D Discrete Anisotropic Radiation Transfer model (DART). Our approach is capable to simulate Tmrt at different scales and under a range of parameters including the urban pattern, surface material of ground, walls, roofs, and properties of the vegetation (coverage, shape, spectral signature, Leaf Area Index and Leaf Area Density). The main advantages of our method are found in (1) the fine treatment of radiation in both short-wave and long-wave domains, (2) detailed specification of optical properties of urban surface materials and of vegetation, (3) precise representation of the vegetation component, and (4) capability to assimilate 3-D inputs derived from multisource remote sensing data. We illustrate and provide a first evaluation of the method in Singapore, a tropical city experiencing strong Urban Heat Island effect (UHI) and seeking to enhance the outdoor thermal comfort. The comparison between DART modelled and field estimated Tmrt shows good agreement in our study site under clear-sky condition over a time period from 10:00 to 19:00 (R2 = 0.9697, RMSE = 3.3249). The use of a 3-D radiative transfer model shows promising capability to study urban microclimate and outdoor thermal comfort with increasing landscape details, and to build linkage to remote sensing data. Our methodology has the potential to contribute towards optimizing climate-sensitive urban design when combined with the appropriate tools.


2011 ◽  
Vol 243-249 ◽  
pp. 4905-4908
Author(s):  
Xue Min Sui ◽  
Xu Zhang ◽  
Guang Hui Han

Relative humidity is an important micro-climate parameter in radiant cooling environment. Based on the human thermal comfort model, this paper studied the effect on PMV index of relative humidity, and studied the relationship of low mean radiant temperature and relative humidity, drew the appropriate design range of indoor relative humidity for radiant cooling systems.The results show that high relative humidity can compensate for the impact on thermal comfort of low mean radiant temperature, on the premise of achieving the same thermal comfort requirements. However, because of the limited compensation range of relative humidity, together with the constraints for it due to anti-condensation of radiant terminal devices, the design range of relative humidity should not be improved, and it can still use the traditional air-conditioning design standards.


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


Finisterra ◽  
2012 ◽  
Vol 42 (84) ◽  
Author(s):  
Henrique Andrade ◽  
Rute Vieira

Measurements of various climatic parameters were carried out in an average-sized green space in the centre of Lisbon (the Fundação Calouste Gulbenkian Park). The aims consisted of assessing the thermal differentiation between the park and the surrounding built-up area and analysing the microclimatic patterns within the park itself. The main results demonstrate that the park is cooler than the built-up area in all the seasons and both during the daytime and at night, but especially so in the daytime during the summer. The most significant microclimatic contrasts were found to occur with respect to solar radiation and mean radiant temperature, with consequences upon the level of thermal comfort. The structure of the vegetation was also found to have a significant microclimatic influence, since the reduction in the level of incident solar radiation brought on by the presence of groups of trees was much larger than that associated with isolated trees.


2011 ◽  
Vol 3 (1) ◽  
Author(s):  
Noémi Kántor ◽  
János Unger

AbstractThis paper gives a review on the topic of the mean radiant temperature Tmrt, the most important parameter influencing outdoor thermal comfort during sunny conditions. Tmrt summarizes all short wave and long wave radiation fluxes reaching the human body, which can be very complex (variable in spatial and also in temporal manner) in urban settings. Thermal comfort researchers and urban planners need easy and sound methodological approaches to assess Tmrt. After the basics of the Tmrt calculation some of the methods suitable for obtaining Tmrt also in urban environments will be presented.. Two of the discussed methods are based on instruments which measure the radiation fluxes integral (globe thermometer, pyranometer-pyrgeometer combination), and three of the methods are based on modelling the radiation environment with PC software (RayMan, ENVI-met and SOLWEIG).


2019 ◽  
Vol 11 (19) ◽  
pp. 5417
Author(s):  
Jinmog Han ◽  
Jongkyun Bae ◽  
Jihoon Jang ◽  
Jumi Baek ◽  
Seung-Bok Leigh

Heating, ventilation, and air-conditioning (HVAC) systems usually have a set-point temperature control feature that uses the indoor dry-bulb temperature to control the indoor environment. However, an incorrect set-point temperature can reduce thermal comfort and result in unnecessary energy consumption. This study focuses on a derivation method for the optimal cooling set-point temperature of an HVAC system used in office buildings, considering the thermal characteristics and daily changes in the weather conditions, to establish a comfortable indoor environment and minimize unnecessary energy consumption. The operative temperature is used in the HVAC system control, and the mean radiant temperature is predicted with 94% accuracy through a multiple regression analysis by applying the indoor thermal environment data and weather information. The regression equation was utilized to create an additional equation to calculate the optimal set-point temperature. The simulation results indicate that the HVAC system control with the new set-point temperatures calculated from the derived equation improves thermal comfort by 38.5% (26%p). This study confirmed that a cooling set-point temperature that considers both the thermal characteristics of a building and weather conditions is effective in enhancing the indoor thermal comfort during summer.


Sign in / Sign up

Export Citation Format

Share Document