scholarly journals Physical Dimensions and Tar and Nicotine Yields of Fine-cut Smoking Articles Rolled by German Consumers

Author(s):  
HF Dymond

AbstractIn 1994, the European Smoking Tobacco Association (ESTA) commissioned and reported a study undertaken in the Netherlands to determine the making habits of roll-your-own smokers. The study included laboratory smoking of the collected smoking articles for the determination of tar and nicotine. In 1997, ESTA commissioned a similar study for Germany involving German fine-cut smokers. This paper reviews the data produced from the German study and compares the data with that produced in the Netherlands. An independent market research agency recruited known smokers of fine-cut tobacco. They were given the most popular brand of tobacco and the most popular brand of booklet paper. The consumers were instructed to make a fine-cut smoking article for testing each time they wanted to smoke. These smoking articles were placed in protective tins and collected by the research agency for analysis. An independent laboratory in Germany undertook the smoking and analysis. This study shows that a German roll-your-own smoker uses an average of 830 mg tobacco and makes a product that is 7.6 mm in diameter. German booklet paper is slightly shorter than Dutch paper. German products are more cylindrical than Dutch products and this probably accounts for the much reduced variability of German products compared with Dutch products. The mean tar yield of these articles was 12 mg and the mean nicotine yield was 0.9 mg.

2009 ◽  
Vol 2 (4) ◽  
pp. 451-459 ◽  
Author(s):  
G. Bakker ◽  
E. Sizoo ◽  
A. Jekel ◽  
D.P. Pereboom-de Fauw ◽  
R. Schothorst ◽  
...  

In 2006, a duplicate diet study of children's food was carried out in the Netherlands. Parents or guardians of 123 children collected duplicates of the 24-hour diets. Levels of aflatoxin M1, aflatoxin B1, ochratoxin A, trichothecenes and fumonisins were determined. Aflatoxin M1 was detectable in 10% of the samples, with all toxin levels below the limit of quantification. Aflatoxin B1 could be detected in 80% of the samples, while in 47% of all samples aflatoxin B1 was quantifiable. Ochratoxin A could be quantified in all samples. Deoxynivalenol was quantified in almost every sample, while T-2 and HT-2 toxins could only be quantified in 3.2% and 6.4% of the samples respectively. 15-acetyldeoxynivalenol was detected in 1.6% of the samples. Fumonisin B1 was detected in 28% of the samples and fumonisin B2 in a quarter of merely those samples where fumonisin B1 was detected. In 20% of the samples fumonisin B1 could be quantified and in a quarter of those samples fumonisin B2 could be quantified too. The analytical results were used to estimate levels of daily intake. Only the mean daily intake levels for aflatoxin B1, ochratoxin A, deoxynivalenol and fumonisins B1 and B2 could reliably be estimated. The values were 0.1, 4.1, 291 and 28 ng/kg bw/day respectively, all are well below the corresponding tolerable daily intakes. For aflatoxin B1 a tolerable intake does not exist, but the intake value for this mycotoxin was very low if compared to the value that would result from the intake of food, if it was contaminated with aflatoxin B1 at the EU regulatory limit, specified for baby food. The mean daily intakes of the mycotoxins determined in children's food in the Netherlands are low and implicate that there is no health risk for children due to exposure from the studied mycotoxins.


1996 ◽  
Vol 75 (05) ◽  
pp. 772-777 ◽  
Author(s):  
Sybille Albrecht ◽  
Matthias Kotzsch ◽  
Gabriele Siegert ◽  
Thomas Luther ◽  
Heinz Großmann ◽  
...  

SummaryThe plasma tissue factor (TF) concentration was correlated to factor VII concentration (FVIIag) and factor VII activity (FVIIc) in 498 healthy volunteers ranging in age from 17 to 64 years. Immunoassays using monoclonal antibodies (mAbs) were developed for the determination of TF and FVIIag in plasma. The mAbs and the test systems were characterized. The mean value of the TF concentration was 172 ± 135 pg/ml. TF showed no age- and gender-related differences. For the total population, FVIIc, determined by a clotting test, was 110 ± 15% and the factor VIlag was 0.77 ± 0.19 μg/ml. FVII activity was significantly increased with age, whereas the concentration demonstrated no correlation to age in this population. FVII concentration is highly correlated with the activity as measured by clotting assay using rabbit thromboplastin. The ratio between FVIIc and FVIIag was not age-dependent, but demonstrated a significant difference between men and women. Between TF and FVII we could not detect a correlation.


1966 ◽  
Vol 16 (01/02) ◽  
pp. 038-050 ◽  
Author(s):  
Ulla Hedner ◽  
Inga Marie Nilsson ◽  
B Robertson

SummaryThe plasminogen content was determined by a casein method in plasma and serum from 20 normal volunteers. The mean plasminogen content was found to be 10.1 ACU (the arbitrary caseinolytic unit defined in such a way that using a 3% casein solution and a digestion time of 20 min. at 37°C, 10 ACU gave an extinction of 0.300). No difference between serum and plasma regarding the plasminogen content was found.Plasminogen was determined in drained and drained plus washed clots prepared from 2 ml plasma. The highest values found in the drained clots were 0.9 ACU/clot and 0.2 ACU/clot in the drained plus washed clots.Plasminogen was also determined in drained and drained plus washed clots prepared from plasma with added purified plasminogen. The plasminogen was recovered in the washing fluid. According to these tests, then, purified added plasminogen is washed out of the clots.The plasminogen content of 20 thrombi obtained post mortem was also determined. The mean value was found to be 0.7 ACU/cm thrombus. Judging from our results, the “intrinsic clot lysis theory” is not the main mechanism of clot dissolution.


1973 ◽  
Vol 72 (4) ◽  
pp. 714-726 ◽  
Author(s):  
A. Burger ◽  
B. Miller ◽  
C. Sakoloff ◽  
M. B. Vallotton

ABSTRACT An improved method for the determination of serum triiodothyronine (T3) has been developed. After addition of a tracer amount of the hormone, T3 was extracted from 1 ml serum under conditions of pH and ionic strength which favoured T3 extraction (89%) over thyroxine (T4) extraction (58%). Chromatography of the extracted material on Sephadex LH-20 separated T3 completely from residual T4. The T3 eluate was dried, then re-dissolved in 0.5 ml NaOH 0.04 n. To 0.2 ml duplicate aliquots, a standard amount of TBG was added for the competitive protein analysis. After one hour incubation at 4°C, separation of bound from free T3 was achieved on small Sephadex G-25 columns. Overall recovery was 67 ± 10.8% and correction for the loss was made. The solvent blank was 37 ± 27 (sd) ng/100 ml. Accuracy of measurement of known quantities of T3 added to serum was 98.4%. The coefficient of variation within the assay was 6.2% and between the assays it was 11.4%. The limit of detection (0.1 ng) corresponded to a concentration of 25 ng/100 ml. T4 added to serum did not interfere with T3 determination until high non-physiological values were reached. The mean ± sd serum T3 in 54 euthyroid subjects was 153 ± 58 ng/100 ml and in 24 hyperthyroid patients it was 428 ±186 ng/100 ml; 4 out of the 24 hyperthyroid values were within 2 sd of the mean euthyroid group. All the values found in the euthyroid group were well above the limit of detection of the method.


2010 ◽  
Vol 35 (4) ◽  
pp. 543-550 ◽  
Author(s):  
Wojciech Batko ◽  
Bartosz Przysucha

AbstractAssessment of several noise indicators are determined by the logarithmic mean <img src="/fulltext-image.asp?format=htmlnonpaginated&src=P42524002G141TV8_html\05_paper.gif" alt=""/>, from the sum of independent random resultsL1;L2; : : : ;Lnof the sound level, being under testing. The estimation of uncertainty of such averaging requires knowledge of probability distribution of the function form of their calculations. The developed solution, leading to the recurrent determination of the probability distribution function for the estimation of the mean value of noise levels and its variance, is shown in this paper.


2020 ◽  
Vol 17 (1) ◽  
pp. 95-105
Author(s):  
Ramji Rathod ◽  
Faraat Ali ◽  
Amrish Chandra ◽  
Robin Kumar ◽  
Meenakshi Dahiya ◽  
...  

Background: A simple and sensitive Ultra Performance Liquid Chromatography-Mass Spectrometry method was developed and validated to measure the concentrations of Alogliptin (ALO), Linagliptin (LIN), Saxagliptin (SAX), and Sitagliptin (SIT) using Pioglitazone (PIO) as an internal standard. Methods: Chromatographic separation of six gliptins was achieved on a C-18 column (100×2.1 mm, 2.7 μm) using a mobile phase consisting of formic acid in water, 0.1%v/v: acetonitrile in gradient elution. Electrospray ionization (ESI) source was operated in the positive ion mode. Targeted MS/MS mode on a QTOF MS was used to quantify the drug utilizing the transitions of 340.1(m/z), 473.2 (m/z), 316.2 (m/z), 408.1 (m/z), and 357.1 (m/z) for ALO, LIN, SAX, SIT and PIO respectively. Results: As per ICH Q2R1 guidelines, a detailed validation of the method was carried out and the standard curves were found to be linear over the concentration ranges of 1516.0-4548.1 ng mL-1, 519.8- 1559.4 ng mL-1, 1531.4-4594.3 ng mL-1and 1519.6-4558.8 ng mL-1 for ALO, LIN, SAX and SIT respectively. Precision and accuracy results were within the acceptable limits. The mean recovery was found to be 98.8 _ 0.76 % (GEM), 102.2 _ 1.59 % (LIN), 95.3 _ 2.74 % (SAX) and 99.2 _ 1.75 % (SIT) respectively. Conclusions: The optimized validated UPLC QTOF-MS/MS method offered the advantage of shorter analytical times and higher sensitivity and selectivity. The optimized method is suitable for application in quantitative analysis of pharmaceutical dosage forms for QC laboratory.


1979 ◽  
Vol 44 (3) ◽  
pp. 700-710 ◽  
Author(s):  
Ivan Fořt ◽  
Hans-Otto Möckel ◽  
Jan Drbohlav ◽  
Miroslav Hrach

Profiles of the mean velocity have been analyzed in the stream streaking from the region of rotating standard six-blade disc turbine impeller. The profiles were obtained experimentally using a hot film thermoanemometer probe. The results of the analysis is the determination of the effect of relative size of the impeller and vessel and the kinematic viscosity of the charge on three parameters of the axial profile of the mean velocity in the examined stream. No significant change of the parameter of width of the examined stream and the momentum flux in the stream has been found in the range of parameters d/D ##m <0.25; 0.50> and the Reynolds number for mixing ReM ##m <2.90 . 101; 1 . 105>. However, a significant influence has been found of ReM (at negligible effect of d/D) on the size of the hypothetical source of motion - the radius of the tangential cylindrical jet - a. The proposed phenomenological model of the turbulent stream in region of turbine impeller has been found adequate for values of ReM exceeding 1.0 . 103.


Sign in / Sign up

Export Citation Format

Share Document