Hydroelastic Response Characteristics of a Pontoon Type VLFS in Waves

1998 ◽  
Vol 1998 (183) ◽  
pp. 211-218 ◽  
Author(s):  
Yoshio Iwahashi ◽  
Shigeo Ohmatsu ◽  
Takashi Tsubogo
Author(s):  
Yoshiyasu Watanabe ◽  
Koichiro Yoshida

It is desired instead of welding to develop a mechanical connector, which may work well to connect two units at the site in spite of circumstances of some extent of relative motions between two units caused by waves. One of the authors proposed a new type of mechanical connector, which is based on an idea of three bodies problem instead of usual mechanical connectors (two bodies problem). In this paper, wave exciting tests of a semisubmersible floating structure model with the proposed mechanical connectors of 1/100 scale and the numerical analysis using hydroelastic response analysis program VODAC are carried out and wave response characteristics of the semisubmersible floating structure model with the mechanical connectors and its feasibility are reported.


2000 ◽  
Vol 14 (1) ◽  
pp. 1-10 ◽  
Author(s):  
Joni Kettunen ◽  
Niklas Ravaja ◽  
Liisa Keltikangas-Järvinen

Abstract We examined the use of smoothing to enhance the detection of response coupling from the activity of different response systems. Three different types of moving average smoothers were applied to both simulated interbeat interval (IBI) and electrodermal activity (EDA) time series and to empirical IBI, EDA, and facial electromyography time series. The results indicated that progressive smoothing increased the efficiency of the detection of response coupling but did not increase the probability of Type I error. The power of the smoothing methods depended on the response characteristics. The benefits and use of the smoothing methods to extract information from psychophysiological time series are discussed.


1997 ◽  
Vol 36 (04/05) ◽  
pp. 237-240
Author(s):  
P. Hammer ◽  
D. Litvack ◽  
J. P. Saul

Abstract:A computer model of cardiovascular control has been developed based on the response characteristics of cardiovascular control components derived from experiments in animals and humans. Results from the model were compared to those obtained experimentally in humans, and the similarities and differences were used to identify both the strengths and inadequacies of the concepts used to form the model. Findings were confirmatory of some concepts but contrary to some which are firmly held in the literature, indicating that understanding the complexity of cardiovascular control probably requires a combination of experiments and computer models which integrate multiple systems and allow for determination of sufficiency and necessity.


2020 ◽  
Vol 12 ◽  
Author(s):  
Fang Wang ◽  
Jingkai Wei ◽  
Caixia Guo ◽  
Tao Ma ◽  
Linqing Zhang ◽  
...  

Background: At present, the main problems of Micro-Electro-Mechanical Systems (MEMS) temperature detector focus on the narrow range of temperature detection, difficulty of the high temperature measurement. Besides, MEMS devices have different response characteristics for various surrounding temperature in the petrochemical and metallurgy application fields with high-temperature and harsh conditions. To evaluate the performance stability of the hightemperature MEMS devices, the real-time temperature measurement is necessary. Objective: A schottky temperature detector based on the metal/n-ZnO/n-Si structures is designed to measure high temperature (523~873K) for the high-temperature MEMS devices with large temperature range. Method: By using the finite element method (FEM), three different work function metals (Cu, Ni and Pt) contact with the n-ZnO are investigated to realize Schottky. At room temperature (298K) and high temperature (523~873K), the current densities with various bias voltages (J-V) are studied. Results: The simulation results show that the high temperature response power consumption of three schottky detectors of Cu, Ni and Pt decreases successively, which are 1.16 mW, 63.63 μW and 0.14 μW. The response temperature sensitivities of 6.35 μA/K, 0.78 μA/K, and 2.29 nA/K are achieved. Conclusion: The Cu/n-ZnO/n-Si schottky structure could be used as a high temperature detector (523~873K) for the hightemperature MEMS devices. It has a large temperature range (350K) and a high response sensitivity is 6.35 μA/K. Compared with traditional devices, the Cu/n-ZnO/n-Si Schottky structure based temperature detector has a low energy consumption of 1.16 mW, which has potential applications in the high-temperature measurement of the MEMS devices.


Author(s):  
Shin-ichi AOKI ◽  
Tomoki HAMANO ◽  
Taishi NAKAYAMA ◽  
Eiichi OKETANI ◽  
Takahiro HIRAMATSU ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document