Load Bearing Structures Made of Glued Laminated Wood and Plywood

2001 ◽  
Vol 85 (5) ◽  
pp. 38-45
Author(s):  
Ari Aalto ◽  
Markku Tuomala
Keyword(s):  
1993 ◽  
Vol 06 (02) ◽  
pp. 100-104 ◽  
Author(s):  
D. M. Pickles ◽  
C. R. Bellenger

SummaryTotal removal of a knee joint meniscus is followed by osteoarthritis in many mammalian species. Altered load-bearing has been observed in the human knee following meniscectomy but less is known about biochemical effects of meniscectomy in other species. Using pressure sensitive paper in sheep knee (stifle) joints it was found that, for comparable loads, the load-bearing area on the medial tibial condyle was significantly reduced following medial meniscectomy. Also, for loads of between 50 N and 500 N applied to the whole joint, the slope of the regression of contact area against load was much smaller. Following medial meniscectomy, the ability to increase contact area as load increased was markedly reduced.The load bearing area on the medial tibial condyle was reduced following meniscectomy.


2015 ◽  
Vol 10 (2) ◽  
pp. 25-34
Author(s):  
Kristian Sogel
Keyword(s):  

Author(s):  
I.O. Egorochkina ◽  
◽  
I.A. Serebryanaya ◽  
S. A. Jamaldinov ◽  
F.A. Bataeva ◽  
...  

The article describes the features of construction and technical expertise of structures of agricultural warehouse of mineral fertilizers. A draft program for visual and detailed instrumental inspection of building load-bearing structures has been developed. In accordance with the recommendations of the regulatory and technical documentation, measures have been developed to repair and restore the functional state of damaged structures.


Author(s):  
Y.P. Manshin ◽  
◽  
E.Yu. Manshina ◽  

The article considers an algorithm for analyzing the results of field strain-measurement studies of machine structures, which allows obtaining data for the modernization of elements in the form of coefficients of parameter changes. As the object of application of the method, the design element of the header was selected, which had failures due to insufficient endurance under cyclic bending stresses.


2020 ◽  
Vol 62 (1) ◽  
pp. 55-60
Author(s):  
Per Heyser ◽  
Vadim Sartisson ◽  
Gerson Meschut ◽  
Marcel Droß ◽  
Klaus Dröder

Alloy Digest ◽  
2017 ◽  
Vol 66 (2) ◽  

Abstract Strenx 700 is a high-strength structural steel with a minimum yield strength of 650–700 MPa (94–102 ksi) depending on thickness. Strenx 700 meets the requirements of EN 10 025-6 for the S690 grade and thicknesses. Typical applications include demanding load-bearing structures. This datasheet provides information on composition, physical properties, and tensile properties as well as fracture toughness. It also includes information on surface qualities as well as forming, machining, and joining. Filing Code: SA-779. Producer or source: SSAB Swedish Steel Inc..


Sign in / Sign up

Export Citation Format

Share Document