Enhancing Fire Resistance Performance of Precast Concrete Load-Bearing Walls by Using Polypropylene Fibers and Wire Mesh

2015 ◽  
Vol 105 (30) ◽  
pp. 1-8
Author(s):  
Thanyawat Pothisiri
2012 ◽  
Vol 628 ◽  
pp. 156-160
Author(s):  
In Kyu Kwon ◽  
Hyung Jun Kim ◽  
Heung Youl Kim ◽  
Bum Yean Cho ◽  
Kyung Suk Cho

Structural steel has been used since the early 1970’s in Korea as primary structural members such as columns, beams, and trusses. The materials have much higher strength such as fast construction, high load bearing capacity, high construction quality but those have a fatal weakness as well. Load-bearing capacity is going down when the structural members are contained in fire condition. Therefore, to protect the structural members made of steels from the heat energy the fire resistance performance required. Generally, the fire resistance performance have evaluated from the exact fire tests in fire furnaces. But the evaluation method takes much more time and higher expenses so, the engineering method requires. The engineering method not only adopts a science but also an engineering experience. In this paper, to make various data-bases for evaluation of structural members such as columns(H-section, RHS), beams, loaded fire tests were conducted and derived not only each limiting temperature but also fire resistance respectively.


2021 ◽  
Vol 11 (23) ◽  
pp. 11500
Author(s):  
Inwook Heo ◽  
Khaliunaa Darkhanbat ◽  
Sun-Jin Han ◽  
Seung-Ho Choi ◽  
Hoseong Jeong ◽  
...  

In this study, full-scale fire tests and finite element (FE) analyses are conducted to investigate the fire resistance performance of hollow-core slabs (HCSs) manufactured using the extrusion method. The deflection of the HCS specimens and the temperature distribution in the section according to the fire exposure time are measured and analyzed comprehensively, and the test results are compared with the FE analysis results. In addition, parametric analyses are conducted on 21 cases with the HCS depth, span length, hollow ratio in a section, cover thickness of concrete, and load ratio (i.e., the ratio of the external load to the ultimate load) as variables, based on which the fire resistance performance of the HCS according to each variable is investigated. The analysis results show that the load ratio is a key factor governing the fire resistance behavior of HCSs, whereas the effects of the cover thickness of concrete and the hollow ratio in a section are relatively slight within the range of variables examined in this study.


Polymers ◽  
2021 ◽  
Vol 13 (11) ◽  
pp. 1701
Author(s):  
R. A. Ilyas ◽  
S. M. Sapuan ◽  
M. R. M. Asyraf ◽  
D. A. Z. N. Dayana ◽  
J. J. N. Amelia ◽  
...  

Polymer composites filled with metal derivatives have been widely used in recent years, particularly as flame retardants, due to their superior characteristics, including high thermal behavior, low environmental degradation, and good fire resistance. The hybridization of metal and polymer composites produces various favorable properties, making them ideal materials for various advanced applications. The fire resistance performance of polymer composites can be enhanced by increasing the combustion capability of composite materials through the inclusion of metallic fireproof materials to protect the composites. The final properties of the metal-filled thermoplastic composites depend on several factors, including pore shape and distribution and morphology of metal particles. For example, fire safety equipment uses polyester thermoplastic and antimony sources with halogenated additives. The use of metals as additives in composites has captured the attention of researchers worldwide due to safety concern in consideration of people’s life and public properties. This review establishes the state-of-art flame resistance properties of metals/polymer composites for numerous industrial applications.


2013 ◽  
Vol 405-408 ◽  
pp. 2305-2310
Author(s):  
Ling Feng Gong ◽  
Yin Bai ◽  
Jian Lei Zhai

With fire temperature rising, elastic modulus of steel would be reduce, which then would lead to global instability phenomenon of double-layer square pyramid silo-shell structure. In order to analyze its fire resistance performance under high fire temperature, different geometric parameters were set based on the effect factors when it operated normally at room temperature. To analyze its displacement change by conducting nonlinear finite element analysis which was under the two typical temperature rising cases including global non-uniform temperature and localized high temperature. Then, with the temperature rising, the fire resistance performance and the maxium displacement changing rule were obtained.


Author(s):  
Yevhen Dmytrenko

Traditional methods of calculation of beam constructions of floors and coverings of industrial buildings assume their consideration when calculating separately from the frame structures, in particular, reinforced concrete slabs, without taking into account their joint work, which leads to a significant margin of safety. Today in Ukraine there is a significant number of industrial buildings and structures that need strengthening and reconstruction. In this regard, of particular importance are studies of the actual load-bearing capacity of the frames of single-storey and multi-storey industrial buildings, and both in the reconstruction and in new construction, the results of which will significantly reduce costs and more rationally design structures. At the same time, one of the most relevant areas is the study of the joint work of metal load-bearing structures with prefabricated reinforced concrete structures of rigid disks of coatings and floors in their calculation.           Moreover, in the national building codes, as well as in the educational and methodological literature, the calculation methods of taking into account the joint work of such constructions are not fully covered. The purpose of this work is to estimate the reduction of mass of the metal beam structure in its calculation in bending, taking into account the joint work with the rigid disk of the floor consist of precast concrete. As part of the study, the calculation of the floor beam according to the traditional calculation scheme - without taking into account the joint work with the floor slab, the calculation of its cross-section taking into account the joint work with floor slabs and experimental numerical study of the floor by the finite element method. Modeling of the floor fragment was performed in the software packages "SCAD Office" and "LIRA CAD 2019". Numerical research is aimed at verifying the feasibility of using the calculation methodology of DBN B.2.6-98-2009 to determine the effective width of the shelf when calculating the T-sections for prefabricated reinforced concrete slabs, which are included in the joint work with the floor beams. A comparative analysis of the obtained cross-section of the beam with the beam which was previously calculated by the traditional method of calculation  in stresses in the most dangerous cross section and the total mass of the beams. According to the results of the analysis, the correctness of the application of the above normative method for determining the effective width of the shelf of T-bending reinforced concrete elements was confirmed.


Sign in / Sign up

Export Citation Format

Share Document