scholarly journals Finite Element Modeling and Parametric Study on Floor Steel Beam Concrete Slab System in Non-Composite Action.

2018 ◽  
Vol 24 (7) ◽  
pp. 95
Author(s):  
Salah R. Al-Zaidee ◽  
Ehab Ghazi Al-Hasany

This study aims to show, the strength of steel beam-concrete slab system without using shear connectors (known as a non-composite action), where the effect of the friction force between the concrete slab and the steel beam has been investigated, by using finite element simulation. The proposed finite element model has been verified based on comparison with an experimental work. Then, the model was adopted to study the system strength with a different steel beam and concrete slab profile. ABAQUS has been adopted in the preparation of all numerical models for this study. After validation of the numerical models, a parametric study was conducted, with linear and non-linear Regression analysis. An equation regarding the concrete slab-steel beam system strength in non-composite action has been pointed out. Where the actual strength of the beam without using shear connectors has been located in between the full composite action and non-composite action. However, partial-composite action has been noted, due to the effectiveness of friction force which makes the beam behave as composite before the slip occurs.  

2016 ◽  
Vol 7 (4) ◽  
pp. 316-327
Author(s):  
Serdar Selamet ◽  
Caner Bolukbas

Purpose This paper aims to present a numerical investigation on the fire performance of a single plate shear connection in a steel-framed composite floor. Large-scale fire experiments show that the tensile membrane action of the concrete slab enhances the fire performance of composite floors. The enhancement in the performance is contributed to large slab deflections. However, these deflections cause significant rotations and tensile force in the single plate connection. Design/methodology/approach A finite element model is constructed, which consists of a secondary steel beam, concrete slab and shear connection components. The interaction between the connection components such as bolts and single plate is defined by contact surfaces. The analysis is conducted in two uncoupled phases: thermal analysis by creating fire boundaries on the composite floor model with convective and radiative heat transfer, and mechanical analysis by considering thermal expansion and changes in the material stiffness and strength due to temperature. Findings The thermo-mechanical analysis of the composite floor finite element model shows that the structure survives the 2-h Standard fire, but the connection fails by bolt shear and buckling of the connection plate. Originality/value This paper investigates the fire performance of a shear connection in a steel-framed concrete slab. Previous work generally focused on the concrete slab behavior only. The originality of the research is that the connection is considered as part of a sub-assembly and is subjected to forces due to concrete and steel beam interaction.


Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 479
Author(s):  
Wei Wang ◽  
Xie-dong Zhang ◽  
Fa-xing Ding ◽  
Xi-long Zhou

High-strength bolted shear connectors (HSBSCs), which can be demounted easily and efficiently during deconstruction, are recommended to replace the conventional steel studs in steel–concrete composite beams (SCCBs) to meet the requirements of sustainable development. The existing investigations on the behavior of HSBSCs mainly focus on the positive moment area of composite beams, in which the concrete slab is in compress condition. In this paper, a three-dimensional finite element model (FEM) was developed to investigate the performance of HSBSCs subjected to inverse push-off loading. Material nonlinearities and the interactions among all components were included in the FEM. The accuracy and reliability of the proposed FEM were initially validated against the available push-off test results. Load-carrying capacity and load–slip response of the HSBSCs under inverse push-off loading were further studied by the verified FEM. A parametric study was carried out to determine the influence of the concrete strength, the diameter and tensile strength of bolt and the clearance between the concrete slab and the bolt as well as the bolt pretension on the shear performance of HSBSCs. Based on the extensive parametric analyses, design recommendations for estimating the shear load at the first slip and load-bearing resistance of HSBSCs were proposed and verified.


Author(s):  
Nguyen Tran Hieu

Nowadays, with the development of cutting and welding technologies, steel beams with regular circular openings, called cellular beams, have been widely used for construction. The cellular beams could be designed either as steel beam or composite beam when headed shear connectors connect concrete slab to top flange of steel beam. This paper presents a procedure to design cellular composite beams according to EN 1994-1-1. In addition, a parametric study is carried out to evaluate the influence of circular opening geometry to ultimate load and failure mode of a series of cellular composite beams. As a result, an optimal dimension of cellular beam is proposed. Article history: Received 28 February 2018, Revised 22 March 2018, Accepted 27 April 2018


Materials ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3346
Author(s):  
Bora Gencturk ◽  
Hadi Aryan ◽  
Mohammad Hanifehzadeh ◽  
Clotilde Chambreuil ◽  
Jianqiang Wei

In this study, an investigation of the shear behavior of full-scale reinforced concrete (RC) beams affected from alkali–silica reactivity damage is presented. A detailed finite element model (FEM) was developed and validated with data obtained from the experiments using several metrics, including a force–deformation curve, rebar strains, and crack maps and width. The validated FEM was used in a parametric study to investigate the potential impact of alkali–silica reactivity (ASR) degradation on the shear capacity of the beam. Degradations of concrete mechanical properties were correlated with ASR expansion using material test data and implemented in the FEM for different expansions. The finite element (FE) analysis provided a better understanding of the failure mechanism of ASR-affected RC beam and degradation in the capacity as a function of the ASR expansion. The parametric study using the FEM showed 6%, 19%, and 25% reduction in the shear capacity of the beam, respectively, affected from 0.2%, 0.4%, and 0.6% of ASR-induced expansion.


2021 ◽  
pp. 136943322110073
Author(s):  
Yu Cheng ◽  
Yuanlong Yang ◽  
Binyang Li ◽  
Jiepeng Liu

To investigate the seismic behavior of joint between special-shaped concrete-filled steel tubular (CFST) column and H-section steel beam, a pseudo-static test was carried out on five specimens with scale ratio of 1:2. The investigated factors include stiffening types of steel tube (multi-cell and tensile bar) and connection types (exterior diaphragm and vertical rib). The failure modes, hysteresis curves, skeleton curves, stress distribution, and joint shear deformation of specimens were analyzed to investigate the seismic behaviors of joints. The test results showed the connections of exterior diaphragm and vertical rib have good seismic behavior and can be identified as rigid joint in the frames with bracing system according to Eurocode 3. The joint of special-shaped column with tensile bars have better seismic performance by using through vertical rib connection. Furthermore, a finite element model was established and a parametric analysis with the finite element model was conducted to investigate the influences of following parameters on the joint stiffness: width-to-thickness ratio of column steel tube, beam-to-column linear stiffness ratio, vertical rib dimensions, and axial load ratio of column. Lastly, preliminary design suggestions were proposed.


2020 ◽  
Vol 203 ◽  
pp. 109863 ◽  
Author(s):  
Lucas Ribeiro dos Santos ◽  
Hermano de Sousa Cardoso ◽  
Rodrigo Barreto Caldas ◽  
Lucas Figueiredo Grilo

2011 ◽  
Vol 243-249 ◽  
pp. 3223-3228
Author(s):  
Zhong Fu Wang ◽  
Han Dong Liu ◽  
Tong Jiang ◽  
Si Wei Wan

Based on geological condition of underground factory building in Hohhot pumped storage power station, research and analysis are taken for the fundamental element which affect initial stress field, 3D finite element model of underground factory building is build for the analysis. Beigin with regrssion analysis, adopt linear elasticity caculation of finite element method to take linear regression analysis, and obtain range of optimized parameters. Adopt homogeneous design to definite various assemblies of optimized parameters at different levels. Obtain training sample by elasto plastic caculation of finite element, train for RBF model in oder to get inverse model of ground stress field. The calculation result shown that: RBF model overcome the disadvantages such as slow calculating speed and overfitting of BP model, and it could obtain distrubution rule of initial stress filed by inverse analysis in a reasonable way.


Author(s):  
MR Karamooz-Ravari ◽  
R Dehghani

Nowadays, NiTi rotary endodontic files are of great importance due to their flexibility which enables the device to cover all the portions of curved canal of tooth. Although this class of files are flexible, intracanal separation might happen during canal preparation due to bending or torsional loadings of the file. Since fabrication and characterization of such devices is challenging, time-consuming, and expensive, it is preferable to predict this failure before fabrication using numerical models. It is demonstrated that NiTi shape memory alloy shows asymmetric material response in tension and compression which can significantly affect the lifetime of the files fabricated from. In this article, the effects of this material asymmetry on the bending response of rotary files are assessed using finite element analysis. To do so, a constitutive model which takes material asymmetry into account is used in combination with the finite element model of a RaCe file. The results show that the material asymmetry can significantly affect the maximum von Mises equivalent stress as well as the force–displacement response of the tip of this file.


2019 ◽  
Vol 22 (16) ◽  
pp. 3487-3502
Author(s):  
Hossein Moravej ◽  
Tommy HT Chan ◽  
Khac-Duy Nguyen ◽  
Andre Jesus

Structural health monitoring plays a significant role in providing information regarding the performance of structures throughout their life spans. However, information that is directly extracted from monitored data is usually susceptible to uncertainties and not reliable enough to be used for structural investigations. Finite element model updating is an accredited framework that reliably identifies structural behavior. Recently, the modular Bayesian approach has emerged as a probabilistic technique in calibrating the finite element model of structures and comprehensively addressing uncertainties. However, few studies have investigated its performance on real structures. In this article, modular Bayesian approach is applied to calibrate the finite element model of a lab-scaled concrete box girder bridge. This study is the first to use the modular Bayesian approach to update the initial finite element model of a real structure for two states—undamaged and damaged conditions—in which the damaged state represents changes in structural parameters as a result of aging or overloading. The application of the modular Bayesian approach in the two states provides an opportunity to examine the performance of the approach with observed evidence. A discrepancy function is used to identify the deviation between the outputs of the experimental and numerical models. To alleviate computational burden, the numerical model and the model discrepancy function are replaced by Gaussian processes. Results indicate a significant reduction in the stiffness of concrete in the damaged state, which is identical to cracks observed on the body of the structure. The discrepancy function reaches satisfying ranges in both states, which implies that the properties of the structure are predicted accurately. Consequently, the proposed methodology contributes to a more reliable judgment about structural safety.


Sign in / Sign up

Export Citation Format

Share Document