Nondestructive NIR Reflectance Spectroscopic Method for Rapid Fatty Acid Analysis of Peanut Seeds

2011 ◽  
Vol 38 (2) ◽  
pp. 85-92 ◽  
Author(s):  
Jaya Sundaram ◽  
Chari V. Kandala ◽  
Christopher L. Butts ◽  
Charles Y. Chen ◽  
Victor Sobolev

ABSTRACT Near Infrared Reflectance Spectroscopy (NIRS) was used to rapidly and nondestructively analyze the fatty acid concentration present in peanut seeds samples. Absorbance spectra were collected in the wavelength range from 400 nm to 2500 nm using NIRS. The oleic, linoleic and palmitic fatty acids were converted to their corresponding methyl esters and their concentrations were measured using a gas chromatograph (GC). Partial least square (PLS) analysis was performed on a calibration set, and models were developed for prediction of fatty acid concentrations. The best model was selected based on the coefficient of determination (R2), Root Mean Square Error of Prediction, residual percent deviation (RPD) and correlation coefficient percentage between the gas chromatography measured values and the NIR predicted values. The NIR reflectance model developed yielded RPD values of three and above for prediction of the three fatty acids, indicating that this nondestructive method would be suitable for fatty acid predictions in peanut seeds.

1998 ◽  
Vol 6 (1) ◽  
pp. 229-234 ◽  
Author(s):  
William R. Windham ◽  
W.H. Morrison

Near infrared (NIR) spectroscopy in the prediction of individual and total fatty acids of bovine M. Longissimus dorsi neck muscles has been studied. Beef neck lean was collected from meat processing establishments using advanced meat recovery systems and hand-deboning. Samples ( n = 302) were analysed to determine fatty acid (FA) composition and scanned from 400 to 2498 nm. Total saturated and unsaturated FA values ranged from 43.2 to 62.0% and 38.3 to 56.2%, respectively. Results of partial least squares (PLS) modeling shown reasonably accurate models were attained for total saturate content [standard error of performance ( SEP = 1.10%); coefficient of determination on the validation set ( r2 = 0.77)], palmitic ( SEP = 0.94%; r2 = 0.69), unsaturate ( SEP = 1.13%; r2 = 0.77), and oleic ( SEP = 0.97; r2 = 0.78). Prediction of other individual saturated and unsaturated FAs was less accurate with an r2 range of 0.10 to 0.53. However, the sum of individual predicted saturated and unsaturated FA was acceptable compared with the reference method ( SEP = 1.10 and 1.12%, respectively). This study shows that NIR can be used to predict accurately total fatty acids in M. Longissimus dorsi muscle.


Author(s):  
ANGGITA ROSIANA PUTRI ◽  
ABDUL ROHMAN ◽  
SUGENG RIYANTO

Objective: The aims of this research were to analyse the fatty acids contained in Patin (Pangasius micronemus) and Gabus (Channa striata) fish oils also its authentication using FTIR spectroscopy combined with chemometrics. Methods: Patin fish oil (PFO) was extracted from patin flesh using the maceration method with petroleum benzene as the solvent, while gabus fish oil (GFO) was purchased from the market in Yogyakarta. The analysis of fatty acid was done using gas chromatography–flame ionization detector (GC-FID). The authentication was performed using FTIR spectrophotometer and chemometrics methods. Principal component analysis (PCA) was used to determine the proximity of oils based on the characteristic similarity. The quantification of adulterated PFO was performed using multivariate calibrations, partial least square (PLS) and principal component regression (PCR). The classification between authentic oils and those adulterated used discriminant analysis (DA). Results: The level of saturated and polyunsaturated fatty acids in PFO is higher than in GFO. The PLS and PCR methods using the second derivative spectra at wavenumbers of 666–3050 cm-1 offered the highest values of coefficient of determination (R2) and lowest root means the square error of calibration (RMSEC) and root mean square error of prediction (RMSEP). Conclusion: The PCA method was successfully used to determine the proximity of oils. Among oils studied, PFO has a similarity fatty acid composition with GFO. The DA method was able to screen pure PFO from adulterated PFO without any misclassification reported. FTIR spectroscopy in combined with chemometrics can be used for authentication and quantification.


2005 ◽  
Vol 10 (1) ◽  
pp. 13
Author(s):  
I. T. Kadim ◽  
W. Al-Marzooqi ◽  
O. Mahgoub ◽  
K. Annamalai

Near-infrared reflectance spectroscopic (NIRS) calibrations were developed for the prediction of the content of dry matter (DM); nitrogen (N), ether extract (EE), neutral detergent fibre (NDF), acid detergent fibre (ADF), gross energy (GE), calcium (Ca) and phosphate (P) in broiler excreta samples. The chemical composition of broiler excreta was determined by the conventional chemical analysis methods in the laboratory and compared with NIRS. Excreta samples (n = 72) were oven dried (60 oC) and analyzed for DM, N, EE, NDF, ADF, GE, Ca and P. The determined values (mean ± SD) were as follows: DM: 31.46 ± 7.65 (range:19.14 - 44.51), N: 5.85 ± 2.88 (range: 4.85 -7.00), EE: 1.37 ± 0.25 (range: 0.88-1.99), ADF: 16.71 ± 1.99 (range: 12.11-19.97), NDF: 26.26 ± 1.63 (range: 22.03-30.21), GE: 15.27 ± 0.33 (range: 14.52-16.11), Ca: 2.57 ± 0.22 (range: 2.16-3.01), P: 1.79 ± 0.15 (range: 1.41-2.11). The samples were then scanned in a NIRS model 5000 analyzer and the spectra obtained for each sample. Calibration equations and prediction values were developed for broiler excreta samples. The software used modified partial least square regression statistic, as it is most suitable for natural products. For broiler excreta samples, the coefficient of determination (R2) and the standard error of prediction (SEP) was DM = 0.97, 1.27, N = 0.95, 0.72, EE = 0.92, 0.07, ADF = 0.87, 0.78, NDF = 0.88, 0.72, GE = 0.89; 0.24, Ca = 0.96, 0.06, P = 0.93, 0.09, respectively. The results indicate that it is possible to calibrate NIRS to predict major constituents in broiler excreta samples.


Animals ◽  
2019 ◽  
Vol 9 (9) ◽  
pp. 640 ◽  
Author(s):  
Goi ◽  
Manuelian ◽  
Currò ◽  
Marchi

The pet food industry is interested in performing fast analyses to control the nutritional quality of their products. This study assessed the feasibility of near-infrared spectroscopy to predict mineral content in extruded dry dog food. Mineral content in commercial dry dog food samples (n = 119) was quantified by inductively coupled plasma optical emission spectrometry and reflectance spectra (850–2500 nm) captured with FOSS NIRS DS2500 spectrometer. Calibration models were built using modified partial least square regression and leave-one-out cross-validation. The best prediction models were obtained for S (coefficient of determination; R2 = 0.89), K (R2 = 0.85), and Li (R2 = 0.74), followed by P, B, and Sr (R2 = 0.72 each). Only prediction models for S and K were adequate for screening purposes. This study supports that minerals are difficult to determine with NIRS if they are not associated with organic molecules.


2009 ◽  
Vol 17 (2) ◽  
pp. 89-100 ◽  
Author(s):  
Yoshifumi Mohri ◽  
Yukoh Sakata ◽  
Makoto Otsuka

The purpose of this study was to construct a calibration model for the prediction of glycyrrhizic acid content in Kakkonto extracts using near infrared (NIR) spectroscopy. The NIR spectra of the Kakkonto extracts were obtained using a Fourier transform NIR spectrometer in transmission mode and chemometric analysis was performed using partial least-square (PLS) regression. The calibration model was constructed by the selection of wave number regions and by the first derivative pre-treatment of NIR spectra. The glycyrrhizic acid content could be predicted using a calibration model comprising three principal components (PCs) obtained by the PLS method. The calibration model was theoretically analysed by investigating the standard error of prediction values, the loading vectors of each PC and the regression vector. The relationship between the actual and predicted glycyrrhizic acid contents in the Kakkonto extract exhibited a straight line with a coefficient of determination of 0.966 (calibration) and 0.945 (validation), respectively. The predicted glycyrrhizic acid content in the Kakkonto extract was within the 95% predictive intervals.


Foods ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 885
Author(s):  
Sergio Ghidini ◽  
Luca Maria Chiesa ◽  
Sara Panseri ◽  
Maria Olga Varrà ◽  
Adriana Ianieri ◽  
...  

The present study was designed to investigate whether near infrared (NIR) spectroscopy with minimal sample processing could be a suitable technique to rapidly measure histamine levels in raw and processed tuna fish. Calibration models based on orthogonal partial least square regression (OPLSR) were built to predict histamine in the range 10–1000 mg kg−1 using the 1000–2500 nm NIR spectra of artificially-contaminated fish. The two models were then validated using a new set of naturally contaminated samples in which histamine content was determined by conventional high-performance liquid chromatography (HPLC) analysis. As for calibration results, coefficient of determination (r2) > 0.98, root mean square of estimation (RMSEE) ≤ 5 mg kg−1 and root mean square of cross-validation (RMSECV) ≤ 6 mg kg−1 were achieved. Both models were optimal also in the validation stage, showing r2 values > 0.97, root mean square errors of prediction (RMSEP) ≤ 10 mg kg−1 and relative range error (RER) ≥ 25, with better results showed by the model for processed fish. The promising results achieved suggest NIR spectroscopy as an implemental analytical solution in fish industries and markets to effectively determine histamine amounts.


2018 ◽  
Vol 17 (4) ◽  
pp. 334-347
Author(s):  
Kwanchayanawish MACHANA ◽  
Amonrat KANOKRUNG ◽  
Sirinart SRICHAN ◽  
Boonyadist VONGSAK ◽  
Maliwan KUTAKO ◽  
...  

Determinations of fatty acid profiles of five microalgae; Amphora sp., Chaetoceros sp., Melosira sp., Bellerochae sp., and Lithodesmium sp., from the east coast of Thailand were evaluated by conventional Gas Chromatography-Flame Ionization Detector (GC-FID). The results exhibited that the fatty acids suitable for biodiesel production were the most frequent entities encountered in all microalgae profiles. The GC chromatogram of fatty acid profiles in microalgae showed that both Amphora sp. and Chaetoceros sp. comprised essential omega-3 fatty acids, eicosapentaenoic acid (EPA), and docosahexaenoic acid (DHA). Additionally, this study assessed whether Fourier Transform infrared (FT-IR) microspectroscopy could be used to evaluate and monitor the biochemical compositions of microalgae, including lipid, carbohydrate, and protein profiles, by using colorimetric methods. Results showed that FT-IR spectra combined with biochemical values of lipid, carbohydrate, and protein contents were used as predictive models generated by partial least square (PLS) regression. Cross-validation of the lipid, protein, and carbohydrate models showed high degrees of statistical accuracy with RMSECV values of approximately 0.5 - 3.22 %, and a coefficient of regression between the actual and predicted values of lipids, carbohydrates, and proteins were 92.66, 95.73, and 96.43 %, respectively. The RPD values were all high (> 3), indicating good predictive accuracy. This study suggested that FT-IR could be a tool for the simultaneous measurement of microalgae composition of biochemical contents in microalgae cells.


1995 ◽  
Vol 78 (3) ◽  
pp. 802-806 ◽  
Author(s):  
José Louis Rodriguez-Otero ◽  
Maria Hermida ◽  
Alberto Cepeda

Abstract Near-infrared reflectance (NIR) spectroscopy was used to analyze fat, protein, and total solids in cheese without any sample treatment. A set of 92 samples of cow’s milk cheese was used for instrument calibration by principal components analysis and modified partial least-square regression. The following statistical values were obtained: standard error of calibration (SEC) = 0.388 and squared correlation coefficient (R2) = 0.99 for fat, SEC = 0.397 and R2 = 0.98 for protein, and SEC = 0.412 and R2 = 0.99 for total solids. To validate the calibration, an independent set of 25 cheese samples of the same type was used. Standard errors of validation were 0.47,0.50, and 0.61 for fat, protein, and total solids, respectively, and hf for the regression of measurements by reference methods versus measurements by NIR spectroscopy was 0.98 for the 3 components.


2015 ◽  
Vol 73 (1) ◽  
Author(s):  
Feri Candra ◽  
Syed Abd. Rahman Abu Bakar

Hyperspectral imaging technology is a powerful tool for non-destructive quality assessment of fruits. The objective of this research was to develop novel calibration model based on hyperspectral imaging to estimate soluble solid content (SSC) of starfruits. A hyperspectral imaging system, which consists of a near infrared  camera, a spectrograph V10, a halogen lighting and a conveyor belt system, was used in this study to acquire hyperspectral  images of the samples in visible and near infrared (500-1000 nm) regions. Partial least square (PLS) was used to build the model and to find the optimal wavelength. Two different masks were applied for obtaining the spectral data. The optimal wavelengths were evaluated using multi linear regression (MLR). The coefficient of determination (R2) for validation using the model with first mask (M1) and second mask (M2) were 0.82 and 0.80, respectively.


2018 ◽  
Vol 64 (No. 6) ◽  
pp. 276-282 ◽  
Author(s):  
Šestak Ivana ◽  
Mesić Milan ◽  
Zgorelec Željka ◽  
Perčin Aleksandra ◽  
Stupnišek Ivan

Spectral data contain information on soil organic and mineral composition, which can be useful for soil quality monitoring. The objective of research was to evaluate hyperspectral visible and near infrared reflectance (VNIR) spectroscopy for field-scale prediction of soil properties and assessment of factors affecting soil spectra. Two hundred soil samples taken from the experiment field (soil depth: 30 cm; sampling grid: 15 × 15 m) were scanned using portable spectroradiometer (350–1050 nm) to identify spectral differences of soil treated with ten different rates of mineral nitrogen (N) fertilizer (0–300 kg N/ha). Principal component analysis revealed distinction between higher- and lower-N level treatments conditioned by differences in soil pH, texture and soil organic matter (SOM) composition. Partial least square regression resulted in very strong correlation and low root mean square error (RMSE) between predicted and measured values for the calibration (C) and validation (V) dataset, respectively (SOM, %: R<sub>C</sub><sup>2</sup> = 0.75 and R<sub>V</sub><sup>2</sup> = 0.74; RMSE<sub>C</sub> = 0.334 and RMSE<sub>V</sub> = 0.346; soil pH: R<sub>C</sub><sup>2</sup> = 0.78 and R<sub>V</sub><sup>2</sup> = 0.62; RMSE<sub>C</sub> = 0.448 and RMSE<sub>V</sub> = 0.591). Results indicated that hyperspectral VNIR spectroscopy is an efficient method for measurement of soil functional attributes within precision farming framework.  


Sign in / Sign up