Optimal Anti-EGFR Treatment of mCRC Patients With Low-Frequency RAS Mutation

Author(s):  
Keyword(s):  
2020 ◽  
Vol 38 (15_suppl) ◽  
pp. 4067-4067
Author(s):  
Timothy Jay Price ◽  
Cynthia Piantadosi ◽  
Amanda Rose Townsend ◽  
Rob Padbury ◽  
Amitesh Chandra Roy ◽  
...  

4067 Background: Effective targeting of RAS mutations has proven elusive until recently. AMG 510, a novel agent which targets KRAS G12C mutations (G12C MT), has shown promise in early phase clinical trials that included patients with mCRC. Prior reports have suggested that G12C MT may be predictive of poor outcome. Methods: We aimed to assess the prognostic implications of individual RAS in a population-based registry. The SAmCRCR collects data from all patients diagnosed with mCRC in South Australia prospectively. Individual RAS mutation data from patients entered into the SAmCRCR between February 2006 and December 2018 was reviewed. Survival was analysed for the more frequent mutations using Kaplan Meier method. Results: 1605 (33%) of the 4905 patients entered onto the registry had RAS mutation results available. Of these, 658 (41%) had RAS MT. The nature of the RAS MT was available in 563 (85.7% of those with RAT MT). Patient characteristics, frequency of individual RAS MT and median overall survival (OS) per RAS MT are noted in table. Low frequency MT made up an additional 16.3%. There were numerical differences in survival however there was no statistical difference in survival when comparing the various RAS MT, including the comparison of G12C to G12S (p = 0.38). Conclusions: Whilst the G12S mutation was associated with the longest survival numerically, the observed survival for patients with the most common RAS mutations (G12C, G12V, G12A, G12D and G13D) did not significantly differ. [Table: see text]


1996 ◽  
Vol 134 (2) ◽  
pp. 177-183 ◽  
Author(s):  
Domenico Salvatore ◽  
Angela Celetti ◽  
Nicole Fabien ◽  
Christian Paulin ◽  
Maria Luisa Martelli ◽  
...  

Salvatore D, Celetti A, Fabien N, Paulin C, Martelli ML, Battaglia C, Califano D, Monaco C, Viglietto G, Santoro M, Fusco A. Low frequency of p53 mutations in human thyroid tumors; p53 and Ras mutation in two out of fifty-six thyroid tumours. Eur J Endocrinol 1996;134:177–83. ISSN 0804–4643 Objective: p53 is a well-known nuclear phosphoprotein encoded by a suppressor gene known to be mutated in various kinds of human tumours. A relationship between p53 gene mutation and tumour progression seems to be a common feature of several neoplasias. Desing: In order to investigate the role of p53 mutations in human thyroid tumours, DNA samples derived from fifty-six neoplastic tissues, ranging from benign adenomas to undifferentiated carcinomas, were examined for the presence of p53 gene mutations. Methods: The analysis has been conducted using polymerase chain reaction (PCR) amplification of the exons 5–9 of the p53 gene followed by single strand conformation polymorphism (SSCP) and sequence analyses. Results: One anaplastic carcinoma and one papillary carcinoma showed p53 gene mutations in exons 5 and 8, respectively. A cell line established from the papillary carcinoma showed the same mutation present in the original tumour. Both p53 mutations were heterozygous. The p53 positive samples were analysed for other genetic alterations frequently detected in human thyroid carcinomas (mutations of the RET, TRK, and ras oncogenes): both p53-mutated samples proved to be mutated at level of codon 13 of the c-Ki-ras gene. Conclusions: Our data confirm that p53 gene alterations are rare in well-differentiated thyroid tumours, that they are an important requirement for the establishment in culture of human thyroid carcinoma cell lines, and that they can be associated with other genetic alterations, namely ras mutations, in the malignant progression of thyroid tumours. Alfredo Fusco, Dipartimento di Biologia e Patologia Cellulare e Molecolare, Facoltà di Medicina e Chirurgia, via S. Pansini 5, 80131, Napoli, Italy


2002 ◽  
Vol 163 (3) ◽  
pp. 326-328 ◽  
Author(s):  
B. Mayr ◽  
G. Winkler ◽  
G. Schaffner ◽  
M. Reifinger ◽  
G. Brem†

Author(s):  
K. Hama

The lateral line organs of the sea eel consist of canal and pit organs which are different in function. The former is a low frequency vibration detector whereas the latter functions as an ion receptor as well as a mechano receptor.The fine structure of the sensory epithelia of both organs were studied by means of ordinary transmission electron microscope, high voltage electron microscope and of surface scanning electron microscope.The sensory cells of the canal organ are polarized in front-caudal direction and those of the pit organ are polarized in dorso-ventral direction. The sensory epithelia of both organs have thinner surface coats compared to the surrounding ordinary epithelial cells, which have very thick fuzzy coatings on the apical surface.


Author(s):  
Robert E. Nordquist ◽  
J. Hill Anglin ◽  
Michael P. Lerner

A human breast carcinoma cell line (BOT-2) was derived from an infiltrating duct carcinoma (1). These cells were shown to have antigens that selectively bound antibodies from breast cancer patient sera (2). Furthermore, these tumor specific antigens could be removed from the living cells by low frequency sonication and have been partially characterized (3). These proteins have been shown to be around 100,000 MW and contain approximately 6% hexose and hexosamines. However, only the hexosamines appear to be available for lectin binding. This study was designed to use Concanavalin A (Con A) and Ricinus Communis (Ricin) agglutinin for the topagraphical localization of D-mannopyranosyl or glucopyranosyl and D-galactopyranosyl or DN- acetyl glactopyranosyl configurations on BOT-2 cell surfaces.


Author(s):  
P. A. Marsh ◽  
T. Mullens ◽  
D. Price

It is possible to exceed the guaranteed resolution on most electron microscopes by careful attention to microscope parameters essential for high resolution work. While our experience is related to a Philips EM-200, we hope that some of these comments will apply to all electron microscopes.The first considerations are vibration and magnetic fields. These are usually measured at the pre-installation survey and must be within specifications. It has been our experience, however, that these factors can be greatly influenced by the new facilities and therefore must be rechecked after the installation is completed. The relationship between the resolving power of an EM-200 and the maximum tolerable low frequency interference fields in milli-Oerstedt is 10 Å - 1.9, 8 Å - 1.4, 6 Å - 0.8.


Author(s):  
G. Y. Fan ◽  
J. M. Cowley

It is well known that the structure information on the specimen is not always faithfully transferred through the electron microscope. Firstly, the spatial frequency spectrum is modulated by the transfer function (TF) at the focal plane. Secondly, the spectrum suffers high frequency cut-off by the aperture (or effectively damping terms such as chromatic aberration). While these do not have essential effect on imaging crystal periodicity as long as the low order Bragg spots are inside the aperture, although the contrast may be reversed, they may change the appearance of images of amorphous materials completely. Because the spectrum of amorphous materials is continuous, modulation of it emphasizes some components while weakening others. Especially the cut-off of high frequency components, which contribute to amorphous image just as strongly as low frequency components can have a fundamental effect. This can be illustrated through computer simulation. Imaging of a whitenoise object with an electron microscope without TF limitation gives Fig. 1a, which is obtained by Fourier transformation of a constant amplitude combined with random phases generated by computer.


Author(s):  
M. T. Postek ◽  
A. E. Vladar

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. The industry requires that an automated instrument must be routinely capable of 5 nm resolution (or better) at 1.0 kV accelerating voltage for the measurement of nominal 0.25-0.35 micrometer semiconductor critical dimensions. Testing and proving that the instrument is performing at this level on a day-by-day basis is an industry need and concern which has been the object of a study at NIST and the fundamentals and results are discussed in this paper.In scanning electron microscopy, two of the most important instrument parameters are the size and shape of the primary electron beam and any image taken in a scanning electron microscope is the result of the sample and electron probe interaction. The low frequency changes in the video signal, collected from the sample, contains information about the larger features and the high frequency changes carry information of finer details. The sharper the image, the larger the number of high frequency components making up that image. Fast Fourier Transform (FFT) analysis of an SEM image can be employed to provide qualitiative and ultimately quantitative information regarding the SEM image quality.


1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


1971 ◽  
Vol 36 (4) ◽  
pp. 527-537 ◽  
Author(s):  
Norman P. Erber

Two types of special hearing aid have been developed recently to improve the reception of speech by profoundly deaf children. In a different way, each special system provides greater low-frequency acoustic stimulation to deaf ears than does a conventional hearing aid. One of the devices extends the low-frequency limit of amplification; the other shifts high-frequency energy to a lower frequency range. In general, previous evaluations of these special hearing aids have obtained inconsistent or inconclusive results. This paper reviews most of the published research on the use of special hearing aids by deaf children, summarizes several unpublished studies, and suggests a set of guidelines for future evaluations of special and conventional amplification systems.


Sign in / Sign up

Export Citation Format

Share Document