PROBLEMS OF DEVELOPMENT OF THE SYSTEM OF MANDATORY METROLOGICAL EXAMINATION OF SPECIAL EQUIPMENT

Author(s):  
K. V.  Epifantsev ◽  
Metrologiya ◽  
2020 ◽  
pp. 3-15
Author(s):  
Rustam Z. Khayrullin ◽  
Alexey S. Kornev ◽  
Andrew A. Kostoglotov ◽  
Sergey V. Lazarenko

Analytical and computer models of false failure and undetected failure (error functions) were developed with tolerance control of the parameters of the components of the measuring technique. A geometric interpretation of the error functions as two-dimensional surfaces is given, which depend on the tolerance on the controlled parameter and the measurement error. The developed models are applicable both to theoretical laws of distribution, and to arbitrary laws of distribution of the measured quantity and measurement error. The results can be used in the development of metrological support of measuring equipment, the verification of measuring instruments, the metrological examination of technical documentation and the certification of measurement methods.


2020 ◽  
Vol 86 (7) ◽  
pp. 39-44
Author(s):  
K. V. Gogolinsky ◽  
A. E. Ivkin ◽  
V. V. Alekhnovich ◽  
A. Yu. Vasiliev ◽  
A. E. Tyurnina ◽  
...  

Thickness is one of the key indicators characterizing the quality and functional properties of coatings. Various indirect methods (electromagnetic, radiation, optical) most often used in practice to measure thickness are based on the functional dependence of a particular physical parameter of the system «base – coating» on the coating thickness. The sensitivity of these procedures to the certain properties of coatings imposes the main restriction to the accuracy of measurements. Therefore, the development and implementation of the approaches based on direct measurements of geometric parameters of the coating appears expedient. These methods often belong to the class of «destructive» and, in addition to measuring instruments, require the use of special equipment. To ensure the uniformity of measurements in the laboratory or technological control, these methods are isolated as a separate procedure (method) and must undergo metrological certification in accordance with GOST R 8.563–2009. We present implementation, metrological certification and practical application of the method for measuring thickness of coatings by crater-grinding method. The principles of technical implementation of test equipment, measurement procedure and calculation formulas are described. The results of evaluating the accuracy indicators of the proposed procedure by calculation and experimental methods are presented. In both cases, the relative error did not exceed 6%. The applicability of the developed technique is shown for a wide range of coating materials (from soft metals to superhard ceramics) of different thickness (with from units to hundreds of micrometers). Apart from the goals of process control and outgoing inspection, the method can be recommended as a reference measurement procedure for calibration of measures and adjusting samples for various types of thickness gauges.


2020 ◽  
pp. 22-29
Author(s):  
A. Bogoyavlenskiy ◽  
A. Bokov

The article contains the results of the metrological examination and research of the accuracy indicators of a method for diagnosing aircraft gas turbine engines of the D30KU/KP family using an ultra-high-frequency plasma complex. The results of metrological examination of a complete set of regulatory documents related to the diagnostic methodology, and an analysis of the state of metrological support are provided as well. During the metrological examination, the traceability of a measuring instrument (diagnostics) – an ultrahigh-frequency plasma complex – is evaluated based on the scintillation analyzer SAM-DT-01–2. To achieve that, local verification schemes from the state primary standards of the corresponding types of measurements were built. The implementation of measures to eliminate inconsistencies identified during metrological examination allows to reduce to an acceptable level the metrological risks of adverse situations when carrying out aviation activities in industry and air transportation. In addition, the probability of occurrence of errors of the first and second kind in the technological processes of tribodiagnostics of aviation gas turbine engines is reduced when implementing a method that has passed metrological examination in real practice. At the same time, the error in determining ratings and wear indicators provides acceptable accuracy indicators and sufficient reliability in assessing the technical condition of friction units of the D-30KP/KP2/KU/KU-154 aircraft engines.


2017 ◽  
Vol 25 (Suppl. 1) ◽  
pp. 121-140
Author(s):  
R. B. Arango ◽  
A. M. Campos ◽  
E. F. Combarro ◽  
E. R. Canas ◽  
I. Díaz

Precision Agriculture entails the appropriate management of the inherent variability of soil and crops, resulting in an increase of economic benefits and a reduction of environmental impact. However, site-specific treatments require maps of the soil variability to identify areas of land that share similar properties. In order to produce these maps, we propose a cost-efficient method that combines clustering algorithms with publicly available satellite imagery. The method does not require exploring the parcels with any special equipment or taking samples of the soil for laboratory analysis. The proposed method was tested in a case study for three vineyard parcels with topographical dissimilarities. The study compares different spectral and thermal bands from the Landsat 8 satellite as well as vegetation and moisture indices to determine which one produces the best clustering. The experimental results seem promising for identification of agricultural management zones. The findings suggest that thermal bands produce better clustering than those based on the NDVI index.


Polymers ◽  
2019 ◽  
Vol 11 (8) ◽  
pp. 1264 ◽  
Author(s):  
Daehan Kim ◽  
Sung-Hwan Kim ◽  
Joong Yull Park

Polydimethylsiloxane (PDMS) membranes are used in various applications, such as microvalves, micropumps, microlenses, and cell culture substrates, with various thicknesses from microscale to nanoscale. In this study, we propose a simple fabrication method for PDMS membranes on a water surface, referred to as the floating-on-water (FoW) method. FoW can be used to easily fabricate PDMS membranes with thicknesses of a few micrometers (minimum 3 μm) without special equipment. In addition, as the membrane is fabricated on the water surface, it can be easily handled without damage. In addition, alternative membrane structures were demonstrated, such as membrane-on-pins and droplet-shaped membranes. FoW can be widely used in various applications that require PDMS membranes with microscale thicknesses.


2019 ◽  
Vol 946 ◽  
pp. 380-385
Author(s):  
Boris A. Chaplygin ◽  
Viacheslav V. Shirokov ◽  
Tat'yana A. Lisovskaya ◽  
Roman A. Lisovskiy

The strength of abrasive wheels is one of the key factors affecting the performance of abrasive machining. The paper discusses ways to improve the strength of abrasive wheels. The stress-state mathematical model presented herein is a generalization of the existing models. It is used herein to find for the first time that there are numerous optimal combinations of the elastic modulus and reinforcing material density, which result in the same minimum value of the objective function. It is found out that increasing the radius of the reinforcing component while also optimizing the mechanical properties of its material may increase the permissible breaking speed of the wheel several times. We herein present a regression equation and a nomogram for finding the optimal combination of control factors. Conventional methods for testing the mechanical properties of materials, which have been proven reliable for testing metals and alloys, are not as reliable for testing abrasive materials, as the test results they generate are not sufficiently stable or accurate. We therefore propose an alternative method that does not require any special equipment or special studies.


Plant Methods ◽  
2021 ◽  
Vol 17 (1) ◽  
Author(s):  
Peio Ziarsolo ◽  
Tomas Hasing ◽  
Rebeca Hilario ◽  
Victor Garcia-Carpintero ◽  
Jose Blanca ◽  
...  

Abstract Background K-seq, a new genotyping methodology based on the amplification of genomic regions using two steps of Klenow amplification with short oligonucleotides, followed by standard PCR and Illumina sequencing, is presented. The protocol was accompanied by software developed to aid with primer set design. Results As the first examples, K-seq in species as diverse as tomato, dog and wheat was developed. K-seq provided genetic distances similar to those based on WGS in dogs. Experiments comparing K-seq and GBS in tomato showed similar genetic results, although K-seq had the advantage of finding more SNPs for the same number of Illumina reads. The technology reproducibility was tested with two independent runs of the tomato samples, and the correlation coefficient of the SNP coverages between samples was 0.8 and the genotype match was above 94%. K-seq also proved to be useful in polyploid species. The wheat samples generated specific markers for all subgenomes, and the SNPs generated from the diploid ancestors were located in the expected subgenome with accuracies greater than 80%. Conclusion K-seq is an open, patent-unencumbered, easy-to-set-up, cost-effective and reliable technology ready to be used by any molecular biology laboratory without special equipment in many genetic studies.


2021 ◽  
pp. 1-6
Author(s):  
Satoshi Morito ◽  
Takao Nitanda ◽  
Ryuko Tsukamoto ◽  
Shingo Kamoshida ◽  
Hiroshi Yasui ◽  
...  

Immunocytochemistry (ICC) is an important ancillary technique in clinical cytology for not only identifying and characterizing tumor cells but also gaining prognostic or therapeutic information. Although cell blocks are often prepared for immunocytochemical evaluation of body cavity fluid and fine-needle aspiration specimens, they are not suitable for hypocellular samples. Liquid-based cytology can help prepare additional smears from residual cytological specimens. However, since conventional methods are used for nongynecological specimens in most laboratories, ICC is often limited by the number of cytological smears. Cell transfer methods permit to evaluate several immunocytochemical markers in a single cytological smear. Yet, these methods have some limitations; for example, they are time-consuming (about 3–40 h) and medium membranes with their attached cells are occasionally stretched or torn when peeled off the slides. Therefore, in an attempt to solve these problems, we developed a rapid and reliable cell transfer method using a nylon mesh. Our method requires no special equipment or reagent and can significantly reduce the turnaround time, as compared to previous methods.


2012 ◽  
Vol 220-223 ◽  
pp. 1633-1637 ◽  
Author(s):  
Gen Li ◽  
Yu Tian Zhu

Based on the requirements of special equipment safety and the current status of recreation facilities test system, a fault diagnosis system for roller coaster was designed. The signal acquisition device was designed, taking digital signal processor as the main control chip. High-frequency vibration acceleration signal and low-frequency motion acceleration signal were acquired. And the data were transmitted to upper computer. By using LabVIEW, the software of upper computer was developed. FFT analysis and wavelet analysis were applied to process the data. BP neural network was applied to fault diagnosis. The test result shows that the system is quick, accurate and reliable.