scholarly journals Coatings in Decellularized Vascular Scaffolds for the Establishment of a Functional Endothelium: A Scoping Review of Vascular Graft Refinement

2021 ◽  
Vol 8 ◽  
Author(s):  
Jun Wei Heng ◽  
Muhammad Dain Yazid ◽  
Mohd Ramzisham Abdul Rahman ◽  
Nadiah Sulaiman

Developments in tissue engineering techniques have allowed for the creation of biocompatible, non-immunogenic alternative vascular grafts through the decellularization of existing tissues. With an ever-growing number of patients requiring life-saving vascular bypass grafting surgeries, the production of functional small diameter decellularized vascular scaffolds has never been more important. However, current implementations of small diameter decellularized vascular grafts face numerous clinical challenges attributed to premature graft failure as a consequence of common failure mechanisms such as acute thrombogenesis and intimal hyperplasia resulting from insufficient endothelial coverage on the graft lumen. This review summarizes some of the surface modifying coating agents currently used to improve the re-endothelialization efficiency and endothelial cell persistence in decellularized vascular scaffolds that could be applied in producing a better patency small diameter vascular graft. A comprehensive search yielding 192 publications was conducted in the PubMed, Scopus, Web of Science, and Ovid electronic databases. Careful screening and removal of unrelated publications and duplicate entries resulted in a total of 16 publications, which were discussed in this review. Selected publications demonstrate that the utilization of surface coating agents can induce endothelial cell adhesion, migration, and proliferation therefore leads to increased re-endothelialization efficiency. Unfortunately, the large variance in methodologies complicates comparison of coating effects between studies. Thus far, coating decellularized tissue gave encouraging results. These developments in re-endothelialization could be incorporated in the fabrication of functional, off-the-shelf alternative small diameter vascular scaffolds.

Author(s):  
M. Yu. Khanova ◽  
E. A. Velikanova ◽  
V. G. Matveeva ◽  
E. O. Krivkina ◽  
T. V. Glushkova ◽  
...  

Objective: to create a cell-populated small-diameter vascular graft (SDVG) using autologous endothelial cells and extracellular matrix proteins, and to evaluate the efficiency of endothelial cell monolayer formation during shear stress preconditioning in a SDVG.Materials and methods. PHBV/PCL tubular scaffolds of vascular grafts were made by electrospinning from a mixture of polyhydroxybutyrate-valerate (PHBV) copolymer and polycaprolactone (PCL) and modified with fibrin. To populate the graft, an endothelial cell culture was isolated from the blood of patients with coronary heart disease. Phenotyping of endothelial colony-forming cell (ECFC) culture was performed by flow cytometry and immunofluorescence microscopy. Cell proliferative and angiogenic activity were also studied. Cell-populated vascular scaffolds were cultured in a pulsatile flow setup with a final shear stress of 2.85 dyne/cm2. The effect of pulsatile flow on monolayer formation was assessed by immunofluorescence, scanning electron microscopy, atomic force microscopy, and whole-transcriptome RNA sequencing.Results. Under the influence of pulsatile flow, endothelial cells that were seeded into the tubular scaffold showed an increase in the expression level of endothelial profile proteins, focal adhesion and cytoskeleton. In contrast to endothelial cell culture on a vascular graft surface under static conditions, when cultured under pulsatile flow with 2.85 dyne/ cm2 shear stress, endothelial lining cells have an increased ability to adhere and are oriented along the pulsatile flow path. Whole-transcriptome RNA sequencing showed that induced shear stress increased expression levels of differentially expressed genes encoding proteins that ensure vascular development, endothelial integrity, and endothelial metabolism. A protocol for fabrication of a personalized cell-populated biodegradable SDVG under pulsatile flow conditions was developed.Conclusion. The use of autologous fibrin and ECFC culture, as well as shear stress preconditioning, allow to obtain a personalized cell-populated SDVG with continuous functional endothelial monolayer adapted to the flow.


1988 ◽  
Vol 1 (1) ◽  
pp. 35-44 ◽  
Author(s):  
Steven P. Schmidt ◽  
Navid Monajjem ◽  
M. Michelle Evancho ◽  
Todd R. Pippert ◽  
W. V. Sharp

2018 ◽  
Vol 14 (8) ◽  
pp. 2598-2608 ◽  
Author(s):  
Vijay Parikh ◽  
Juned Kadiwala ◽  
Araida Hidalgo Bastida ◽  
Cathy Holt ◽  
Mohammad Sanami ◽  
...  

2000 ◽  
Vol 84 (08) ◽  
pp. 325-331 ◽  
Author(s):  
M. J. B. Wissink ◽  
M. J. A. van Luyn ◽  
R. Beernink ◽  
F. Dijk ◽  
A. A. Poot ◽  
...  

SummaryEndothelial cell seeding, a promising method to improve the performance of small-diameter vascular grafts, requires a suitable substrate, such as crosslinked collagen. Commonly used crosslinking agents such as glutaraldehyde and formaldehyde cause, however, cytotoxic reactions and thereby hamper endothelialization of currently available collagen-coated vascular graft materials.The aim of this study was to investigate the effects of an alternative method for crosslinking of collagen, using N-(3-dimethylaminopropyl)-N’-ethylcarbodiimide (EDC) in combination with N-hydroxysuccinimide (NHS), on various cellular functions of human umbilical vein endothelial cells (HUVECs) in vitro. Compared to non-crosslinked type I collagen, proliferation of seeded endothelial cells was significantly increased on EDC/NHS-crosslinked collagen. Furthermore, higher cell numbers were found with increasing crosslink densities. Neither the morphology of the cells nor the secretion of prostacyclin (PGI2), von Willebrand factor (vWF), tissue plasminogen activator (t-PA) and plasminogen activator inhibitor (PAI-1) was affected by the crosslink density of the collagen substrate. Therefore, EDC/NHScrosslinked collagen is candidate substrate for in vivo application such as endothelial cell seeding of collagen-coated vascular grafts.


2017 ◽  
Vol 5 (30) ◽  
pp. 5942-5953 ◽  
Author(s):  
Fatemeh Karimi ◽  
Thomas G. McKenzie ◽  
Andrea J. O'Connor ◽  
Greg G. Qiao ◽  
Daniel E. Heath

Blood contacting devices are commonly used in today's medical landscape.


2008 ◽  
Vol 22 (S2) ◽  
pp. 605-605
Author(s):  
Mauricio Antonio Contreras ◽  
Mathew Douglas Phaneuf ◽  
Shengqian Wu ◽  
Martin J. Bide ◽  
Frank W. LoGerfo

2015 ◽  
Vol 3 (47) ◽  
pp. 9212-9222 ◽  
Author(s):  
Yuanyuan Wang ◽  
Siyuan Chen ◽  
Yiwa Pan ◽  
Jingchen Gao ◽  
Di Tang ◽  
...  

Rapidin situendothelialization of a small diameter vascular graft with catalytic nitric oxide generation and promoted endothelial cell adhesion.


1995 ◽  
Vol 4 (4) ◽  
pp. 401-410 ◽  
Author(s):  
Stuart K. Williams

Endothelial cells line the lumenal surface of al) elements of the vascular system. These cells exhibit numerous metabolic functions necessary for the maintenance of homeostasis. The critical role of endothelium in maintaining normal blood vessel function is exemplified by the poor clinical performance of small diameter polymeric vascular grafts which fail due, in part, to the lack of a functional endothelium on the lumenal surface. Extensive research has explored the potentiality of transplanting endothelial cells onto polymeric vascular grafts to improve graft function. Several critical issues have been explored including the source of endothelial cells for transplantation, the interaction of endothelium with polymers and the healing process of endothelial cell transplanted grafts. The future of endothelial cell transplantation will also include the use of these cells as vehicles for genetic engineering.


1985 ◽  
Vol 2 (6) ◽  
pp. 898-906 ◽  
Author(s):  
Steven P. Schmidt ◽  
Timothy J. Hunter ◽  
Linda J. Falkow ◽  
M. Michelle Evancho ◽  
William V. Sharp

2021 ◽  
Author(s):  
◽  
William King, III ◽  

The ideal “off the shelf” tissue engineering, small-diameter (< 6 mm inner diameter (ID)) vascular graft hinges on designing a template that facilitates transmural ingrowth of capillaries to regenerate an endothelized neointimal surface. Previous traditionally electrospun (TES) approaches to create bioresorbable vascular grafts lack the pore sizes required to facilitate transmural capillary ingrowth required for successful in situ neovascular regeneration. Therefore, the ability to create scaffolds with program-specific architectures independent of fiber diameter via the relatively recent sub-technique of near-field electrospinning (NFES) represents a promising solution to create tissue engineering vascular grafts. These programmed large pore sizes are anticipated to promote in situ regeneration and improve the outcomes as well as the quality of life of patients with arterial disease. In this dissertation, we manufactured via NFES as well as characterized biodegradable polydioxanone (PDO) small-diameter vascular grafts. Chapter 1 introduces the need for off-the-shelf, small-diameter vascular grafts to facilitate in situ regeneration, the process and pore size limitations of TES vascular grafts, and the promising use of NFES to develop precisely tailored PDO vascular grafts. Chapter 2 describes the process of NFES and details the current progress in NFES of biomedical polymers as well as the major limitations that exist in the field. Chapters 3, 4, and 5 contain primary research exploring the creation of an NFES vascular graft scaffold and characterizing the mechanical as well as biological response of these scaffolds. Specifically, in Chapter 3 we demonstrate a NFES apparatus designed around a commercial 3D printer to write PDO microfibers. The processing parameters of air gap, polymer concentration, translational velocity, needle gauge, and applied voltage were characterized for their effects on PDO fiber diameter. The processing parameters of polymer concentration and translational fiber deposition velocity were further characterized for their effects on fiber crystallinity and individual fiber uniformity. The precision of fiber stacking via a 3D printer was qualitatively evaluated to inform the creation of 3D scaffolds to guide the alignment of human gingival fibroblasts. It was found that fiber diameters correlate positively with polymer concentration, applied voltage, and needle gauge and inversely correlate with translational velocity and air gap distance. Individual fiber diameter variability decreases, and crystallinity increases with increasing translational fiber deposition velocity. These data resulted in the creation of tailored PDO 3D scaffolds which guided the alignment of primary human fibroblast cells. Together, these results suggest that NFES of PDO can be scaled to create precise geometries with tailored fiber diameters for vascular graft scaffolds. In Chapter 4, we demonstrated a NFES device to semi-stably write PDO microfibers. The polymer spinneret was programmed to translate in a stacking grid pattern, which resulted in a scaffold with highly aligned grid fibers that were intercalated with low density, random fibers. As a consequence of this random switching process, increasing the grid dimensions resulted in both a lower density of fibers in the center of each grid in the scaffold as well as a lower density of “rebar-like” stacked fibers per unit area. These hybrid architecture scaffolds resulted in tailorable as well as greater surface pore sizes as given by scanning electron micrographs and effective object permeability as indicated by fluorescent microsphere filtration compared to TES scaffolds of the same fiber diameter. Furthermore, these programmable scaffolds resulted in tailorability in the characterized mechanical properties ultimate tensile strength, percent elongation, yield stress, yield elongation, and Young’s modulus independent of fiber diameter compared to the static TES scaffold characterization. Lastly, the innate immune response of neutrophil extracellular traps (NETs) was further attenuated on NFES scaffolds compared to TES scaffolds. These results suggest that this novel NFES scaffold architecture of PDO can be highly tailored as a function of programming for small diameter vascular graft scaffolds. In Chapter 5, we created two types of NFES PDO architectures, as small-diameter vascular graft scaffolds. The first architecture type consisted of a 200 x 200 µm and 500 x 500 µm grid geometry with random fiber infill produced from one set of processing parameters, while the second architecture consisted of aligned fibers written in a 45°/45° and 20°/70° offset from the long axis, both on a 4 mm diameter cylindrical mandrel. These vascular graft scaffolds were characterized for their effective object transit pore size, mechanical properties, and platelet-material interactions compared to TES scaffolds and Gore-Tex® vascular grafts. It was found that effective pore size, given by 9.9 and 97 µm microsphere filtration through the scaffold wall for NFES grafts, was significantly more permeable compared to TES grafts and Gore-Tex® vascular grafts. Furthermore, the characterized mechanical properties of ultimate tensile strength, percent elongation, suture retention, burst pressure, and Young’s modulus were all tailorable for NFES grafts, independent of fiber diameter, compared to TES graft characterization. Lastly, platelet adhesion was attenuated on large pore size NFES grafts compared to the TES grafts which approximated the low level of platelet adhesion measured on Gore-Tex® grafts, with all grafts showing minimal platelet activation given by P-selectin surface expression. Together, these results suggest a highly tailorable process for the creation of the next generation of small-diameter vascular grafts. Lastly, Chapter 6 expounds future considerations for continuing research in NFES technology, NFES for general tissue engineering, and NFES for vascular tissue engineering as well as gives final conclusions. Together, the finding of this dissertation indicated that NFES vascular grafts result in seamless, small diameter tubular scaffolds with programmable pore sizes on the magnitude anticipated to facilitate transmural endothelialization as well as programmable mechanical properties that approximate native values. Thus, this work represents the next step in developing bioinstructive designed scaffolds to facilitate in situ vascular regeneration to improve the outcomes as well as the quality of life of patients with arterial vascular disease.


Sign in / Sign up

Export Citation Format

Share Document