scholarly journals Correlation Between Physiological and Performance-Based Metrics to Estimate Pilots' Cognitive Workload

2021 ◽  
Vol 12 ◽  
Author(s):  
P. Archana Hebbar ◽  
Kausik Bhattacharya ◽  
Gowdham Prabhakar ◽  
Abhay A. Pashilkar ◽  
Pradipta Biswas

This paper discusses the utilization of pilots' physiological indications such as electroencephalographic (EEG) signals, ocular parameters, and pilot performance-based quantitative metrics to estimate cognitive workload. The study aims to derive a non-invasive technique to estimate pilot's cognitive workload and study their correlation with standard physiological parameters. Initially, we conducted a set of user trials using well-established psychometric tests for evaluating the effectiveness of pupil and gaze-based ocular metrics for estimating cognitive workload at different levels of task difficulty and lighting conditions. Later, we conducted user trials with the NALSim flight simulator using a business class Learjet aircraft model. We analyzed participants' ocular parameters, power levels of different EEG frequency bands, and flight parameters for estimating variations in cognitive workload. Results indicate that introduction of secondary task increases pilot's cognitive workload significantly. The beta frequency band of EEG, nearest neighborhood index specifying distribution of gaze fixation, L1 Norm of power spectral density of pupil diameter, and the duty cycle metric indicated variations in cognitive workload.

2016 ◽  
Vol 6 (2) ◽  
pp. 81-90 ◽  
Author(s):  
Kathleen Van Benthem ◽  
Chris M. Herdman

Abstract. Identifying pilot attributes associated with risk is important, especially in general aviation where pilot error is implicated in most accidents. This research examined the relationship of pilot age, expertise, and cognitive functioning to deviations from an ideal circuit trajectory. In all, 54 pilots, of varying age, flew a Cessna 172 simulator. Cognitive measures were obtained using the CogScreen-AE ( Kay, 1995 ). Older age and lower levels of expertise and cognitive functioning were associated with significantly greater flight path deviations. The relationship between age and performance was fully mediated by a cluster of cognitive factors: speed and working memory, visual attention, and cognitive flexibility. These findings add to the literature showing that age-related changes in cognition may impact pilot performance.


2015 ◽  
Vol 11 (1) ◽  
pp. 2897-2908
Author(s):  
Mohammed S.Aljohani

Tomography is a non-invasive, non-intrusive imaging technique allowing the visualization of phase dynamics in industrial and biological processes. This article reviews progress in Electrical Capacitance Volume Tomography (ECVT). ECVT is a direct 3D visualizing technique, unlike three-dimensional imaging, which is based on stacking 2D images to obtain an interpolated 3D image. ECVT has recently matured for real time, non-invasive 3-D monitoring of processes involving materials with strong contrast in dielectric permittivity. In this article, ECVT sensor design, optimization and performance of various sensors seen in literature are summarized. Qualitative Analysis of ECVT image reconstruction techniques has also been presented.


2014 ◽  
pp. 9-18
Author(s):  
Thi Linh Giang Truong ◽  
Vu Quoc Huy Nguyen

Background: Assessment of fetal health plays the most important role in prenatal care because of influence of the prediction of gestational outcome. One of the main aims of routine antenatal care is to identify the ‘ at risk ‘ fetus in order to apply clinical interventions which could results in reduced perinatal morbidity and mortality. Doppler ultrasound is a non invasive technique whereby the movement of blood is studied by detecting the change in frequence of reflected sound, Doppler blood flow velocity waves form of fetal side (umbilical artery, middle cerebral artery ...) and maternal side ( uterine arteries) are discussed and monograms for routine practice are presented. Recently this method is important tool for qualifying high risk pregnancies and help early forecasts the health of the babies and mothers disorder. Doppler sonography in obstetrics is a widely accepted functional method of examining the prediction of gestational outcome. Key words: Doppler, umbilical artery, middle cerebral artery, uterine arteries


2020 ◽  
Vol 11 (1) ◽  
pp. 25
Author(s):  
Sonia Hermoso-Durán ◽  
Guillermo García-Rayado ◽  
Laura Ceballos-Laita ◽  
Carlos Sostres ◽  
Sonia Vega ◽  
...  

Background: Current efforts in the identification of new biomarkers are directed towards an accurate differentiation between benign and premalignant cysts. Thermal Liquid Biopsy (TLB) has been previously applied to inflammatory and tumor diseases and could offer an interesting point of view in this type of pathology. Methods: In this work, twenty patients (12 males and 8 females, average ages 62) diagnosed with a pancreatic cyst benign (10) and premalignant (10) cyst lesions were recruited, and biological samples were obtained during the endoscopic ultrasonography procedure. Results: Proteomic content of cyst liquid samples was studied and several common proteins in the different groups were identified. TLB cyst liquid profiles reflected protein content. Also, TLB serum score was able to discriminate between healthy and cysts patients (71% sensitivity and 98% specificity) and between benign and premalignant cysts (75% sensitivity and 67% specificity). Conclusions: TLB analysis of plasmatic serum sample, a quick, simple and non-invasive technique that can be easily implemented, reports valuable information on the observed pancreatic lesion. These preliminary results set the basis for a larger study to refine TLB serum score and move closer to the clinical application of TLB providing useful information to the gastroenterologist during patient diagnosis.


2021 ◽  
Vol 224 (2) ◽  
pp. S182-S183
Author(s):  
Zaid Diken ◽  
Antonio F. Saad ◽  
Sema Hajmurad ◽  
Rakesh Vadhera ◽  
Michelle Simon ◽  
...  

2021 ◽  
Vol 75 (2) ◽  
pp. 125-133
Author(s):  
Soňa Franková ◽  
Jan Šperl

Portal hypertension represents a wide spectrum of complications of chronic liver diseases and may present by ascites, oesophageal varices, splenomegaly, hypersplenism, hepatorenal and hepatopulmonary syndrome or portopulmonary hypertension. Portal hypertension and its severity predicts the patient‘s prognosis: as an invasive technique, the portosystemic gradient (HPVG – hepatic venous pressure gradient) measurement by hepatic veins catheterisation has remained the gold standard of its assessment. A reliable, non-invasive method to assess the severity of portal hypertension is of paramount importance; the patients with clinically significant portal hypertension have a high risk of variceal bleeding and higher mortality. Recently, non-invasive methods enabling the assessment of liver stiffness have been introduced into clinical practice in hepatology. Not only may these methods substitute for liver biopsy, but they may also be used to assess the degree of liver fibrosis and predict the severity of portal hypertension. Nowadays, we can use the quantitative elastography (transient elastography, point shear-wave elastrography, 2D-shear-wave elastography) or magnetic resonance imaging. We may also assess the severity of portal hypertension based on the non-invasive markers of liver fibrosis (i.e. ELF test) or estimate clinically signifi cant portal hypertension using composite scores (LSPS – liver spleen stiff ness score), based on liver stiffness value, spleen diameter and platelet count. Spleen stiffness measurement is a new method that needs further prospective studies. The review describes current possibilities of the non-invasive assessment of portal hypertension and its severity.


Author(s):  
Christopher A. Lerch ◽  
Richard H. Lyon

Abstract A method termed harmonic tracking is developed to recover time dependent gear motion from machine casing vibration. The harmonic tracking method uses short-time spectral generation and a subsequent set of algorithms to locate and track gear meshing frequencies as functions of time. The meshing frequencies are then integrated with respect to time to obtain the rotation of individual gears. More specifically, spectral generation is performed using the discrete Fourier transform, and the locating and tracking algorithms involve locating tones in each short-time spectrum and tracking them through successive spectra to recover gear meshing harmonics. The harmonic tracking method is found to be more robust than demodulation-based methods in the presence of measurement noise and signal distortion from the structural transfer function between gears and the casing. The harmonic tracking method is tested, both through simulation and experiments involving motor-operated valves (MOV’s) as part of the development of a diagnostic system for MOV’s. In all cases, the harmonic tracking method is found to recover gear motion with sufficient accuracy to perform diagnostics. The harmonic tracking method should be generally applicable to situations in which a non-invasive technique is required for determining the time-dependent angular speeds and displacements of gearbox input, intermediary, and output shafts.


Sign in / Sign up

Export Citation Format

Share Document