scholarly journals The Diagnostic Significance of PDGF, EphA7, CCR5, and CCL5 Levels in Colorectal Cancer

Biomolecules ◽  
2019 ◽  
Vol 9 (9) ◽  
pp. 464 ◽  
Author(s):  
Üçüncü ◽  
Serilmez ◽  
Sarı ◽  
Bademler ◽  
Karabulut

In this study, we compared the levels of C-C chemokine receptor type 5 (CCR5), C-C motif chemokine ligand 5 (CCL5), platelet-derived growth factor (PDGF), and EphrinA7 (EphA7) in patients with colorectal carcinoma and healthy controls in order to investigate the significance and usability of these potential biomarkers in early diagnosis of colorectal cancer. The study included 70 colorectal carcinoma patients and 40 healthy individuals. The CCR5, CCL5, PDGF, and EphA7 levels were measured using ELISA in blood samples. PDGF-BB, EphA7, CCR5, and CCL5 levels of the patients with colorectal carcinoma were significantly higher compared to the control group (p < 0.001 for each comparison). Our logistic regression analysis (the area under the curve was 0.958) supports the notion that PDGF-BB, EphA7, and CCL5 are potential biomarkers for the diagnosis of colon cancer. The sensitivity, specificity, and positive and negative predictive values were found to be 87.9%, 87.5%, 92.1%, and 81.4%, respectively. To our knowledge, this is the first study that investigates the relationship between colorectal carcinoma and the four biomarkers CCL5, CCR5, PDGF, and EphA7. The significantly elevated levels of all these parameters in the patient group compared to the healthy controls indicate that they can be used for the early diagnosis of colorectal carcinoma.

2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
Narges Moslemi Zadeh ◽  
Farshad Naghshvar ◽  
Sepideh Peyvandi ◽  
Parand Gheshlaghi ◽  
Sara Ehetshami

Background. Preeclampsia affects 5-6% of all pregnancies. Predictive factors of preeclampsia can be helpful in early diagnosis of this disease. In this study the predictive values of biochemical markers placenta protein 13 (PP13) and pregnancy-associated plasma protein A (PAPP-A) have been assessed in early diagnosis of preeclampsia. Methods. This case-control study was conducted on 1500 women who presented to a healthcare center of Sari, Iran, between 2010 and 2011. Blood samples were drawn in weeks 11–13 and 24–28 of pregnancy. Of them who developed preeclampsia were considered as case group. A control group consisted of similar women regarding mean age, body mass index (BMI), and pregnancy age. PAPP-A and PP13 serum levels were measured. Data were analyzed using proper statistical tests. Results. PAPP-A and PP13 serum levels were significantly lower in both the first and second trimesters in women who developed preeclampsia (P<0.001). The cumulative value of all four variables with cut-off point of 238.5 has sensitivity, specificity of 91.0%, and undercurve surface of 0.968 which is the most diagnostic value for preeclampsia. Conclusion. It is possible to advantage measuring of PAPP-A and PP13 in the first and second trimesters especially their cumulative values in both trimesters for prediction of the incidence of preeclampsia.


2015 ◽  
Vol 87 (7) ◽  
Author(s):  
Katarzyna Malinowska ◽  
Michał Mik ◽  
Łukasz Dziki ◽  
Adam Dziki ◽  
Ireneusz Majsterek

AbstractCancers are among the most feared diseases of modern civilization. In Poland, colorectal cancer is one of the tumors with the worst prognosis. The ability to cure is primarily dependent on the stage of the disease at the time of diagnosis.was evaluate antioxidant response in patients with colorectal carcinoma.Twenty patients (14 men and 6 women) aged 61.9± 11.1 years with colorectal cancer were included in the study. Twenty healthy subjects (4 men and 16 women) aged 64 ± 15.3 years formed the control group. The erythrocyte activities of antioxidant enzymes, superoxide dismutase (SOD), and glutathione peroxidase (GPx),A significant increase of GPx, and SOD (p < 0.05) were seen in patients compared to healthy controls.The results indicate that the tested antioxidant enzyme activity of glutathione peroxidase and superoxide dismutase is increased in patients diagnosed with colorectal cancer compared to the control group.


2019 ◽  
Vol 79 (2) ◽  
pp. 169-173 ◽  
Author(s):  
A. L. Cabana ◽  
M. O. Xavier ◽  
J. F. Mendes ◽  
A. J. Teles ◽  
A. M. Martins ◽  
...  

Abstract Even today, an effective diagnostic test for aspergillosis in penguins is unknown, being the gold standard post-mortem examinations. The fungal antigen galactomannan (GM) has been used as a biomarker of disease in humans and is detected by the Platelia Aspergillus EIA (BioRad)®, a commercial kit based on the sandwich ELISA technique. It is standardized for use in neutropenic patients, however studies have demonstrated its usefulness also possible for birds. The aim of our study was to evaluate the effectiveness of Platelia Aspergillus EIA® test (BioRad-US) in the diagnosis of aspergillosis in Magellanic penguins, determining sensitivity, specificity, and positive and negative predictive values for different cut-off points. Were included in the study, blood serum samples (n = 29) Magellanic penguins in captivity that died by aspergillosis. Detection of GM was performed following manufacturer's instructions and the GM index was obtained by dividing the average value of OD of the duplicate of the clinical sample by duplicate OD of the average value of the cut-off sample provided by the kit. Through information database results were obtained for the presence of anti-Aspergillus fumigatus antibodies detected by agar gel immunodiffusion (AGID) for all serum samples. Results were analyzed using chi-square test and Kruskal-Wallis from SPSS 20.0, IBM®. ROC curve was obtained and from this, rates of sensitivity, specificity, positive and negative predictive values were also calculated based on four different cutoff points (0.5, 1.0, 1.5 and 2.0). The serum GM index did not differ between animals of the case and control group (pkw =0.097). In determining the ROC curve for serum GM detection the value of area under the curve was 0.635. From the values determined by the coordinate of the curve, four different cut points (0.5, 1.0, 1.5 and 2.0) were analyzed, resulting in sensitivity rates ranging from 86.2 to 34.5% % and specificity between 87% and 26.1%. By comparing the serum GM index in group case as the presence or absence of antibodies detected by AGID was found p=0.503. The detection of GM the Platelia Aspergillus EIA® test seems is not be useful for the diagnosis of aspergillosis in naturally infected penguins.


Entropy ◽  
2020 ◽  
Vol 22 (7) ◽  
pp. 729 ◽  
Author(s):  
Peter Oehr ◽  
Thorsten Ecke

Background: This investigation included both a study of potential non-invasive diagnostic approaches for the bladder cancer biomarker UBC® Rapid Test and a study including comparative methods about sensitivity–specificity characteristic (SS-ROC) and predictive receiver operating characteristic (PV-ROC) curves that used bladder cancer as a useful example. Methods: The study included 289 urine samples from patients with tumors of the urinary bladder, patients with non-evidence of disease (NED) and healthy controls. The UBC® Rapid Test is a qualitative point of care assay. Using a photometric reader, quantitative data can also be obtained. Data for pairs of sensitivity/specificity as well as positive/negative predictive values were created by variation of threshold values for the whole patient cohort, as well as for the tumor-free control group. Based on these data, sensitivity–specificity and predictive value threshold distribution curves were constructed and transformed into SS-ROC and PV-ROC curves, which were included in a single SS/PV-ROC plot. Results: The curves revealed TPP-asymmetric improper curves which cross the diagonal from above. Evaluation of the PV-ROC curve showed that two or more distinct positive predictive values (PPV) can correspond to the same value of a negative predictive value (NPV) and vice versa, indicating a complexity in PV-ROC curves which did not exist in SS-ROC curves. In contrast to the SS-ROC curve, the PV-ROC curve had neither an area under the curve (AUC) nor a range from 0% to 100%. Sensitivity of the qualitative assay was 58.5% and specificity 88.2%, PPV was 75.6% and NPV 77.3%, at a threshold value of approximately 12.5 µg/L. Conclusions: The SS/PV-ROC plot is a new diagnostic approach which can be used for direct judgement of gain and loss of predictive values, sensitivity and specificity according to varied threshold value changes, enabling characterization, comparison and evaluation of qualitative and quantitative bioassays.


2020 ◽  
Vol 163 (6) ◽  
pp. 1156-1165
Author(s):  
Juan Xiao ◽  
Qiang Xiao ◽  
Wei Cong ◽  
Ting Li ◽  
Shouluan Ding ◽  
...  

Objective To develop an easy-to-use nomogram for discrimination of malignant thyroid nodules and to compare diagnostic efficiency with the Kwak and American College of Radiology (ACR) Thyroid Imaging, Reporting and Data System (TI-RADS). Study Design Retrospective diagnostic study. Setting The Second Hospital of Shandong University. Subjects and Methods From March 2017 to April 2019, 792 patients with 1940 thyroid nodules were included into the training set; from May 2019 to December 2019, 174 patients with 389 nodules were included into the validation set. Multivariable logistic regression model was used to develop a nomogram for discriminating malignant nodules. To compare the diagnostic performance of the nomogram with the Kwak and ACR TI-RADS, the area under the receiver operating characteristic curve, sensitivity, specificity, and positive and negative predictive values were calculated. Results The nomogram consisted of 7 factors: composition, orientation, echogenicity, border, margin, extrathyroidal extension, and calcification. In the training set, for all nodules, the area under the curve (AUC) for the nomogram was 0.844, which was higher than the Kwak TI-RADS (0.826, P = .008) and the ACR TI-RADS (0.810, P < .001). For the 822 nodules >1 cm, the AUC of the nomogram was 0.891, which was higher than the Kwak TI-RADS (0.852, P < .001) and the ACR TI-RADS (0.853, P < .001). In the validation set, the AUC of the nomogram was also higher than the Kwak and ACR TI-RADS ( P < .05), each in the whole series and separately for nodules >1 or ≤1 cm. Conclusions When compared with the Kwak and ACR TI-RADS, the nomogram had a better performance in discriminating malignant thyroid nodules.


2021 ◽  
Vol 10 (12) ◽  
pp. 2675
Author(s):  
Monika Zajkowska ◽  
Agnieszka Kulczyńska-Przybik ◽  
Maciej Dulewicz ◽  
Kamil Safiejko ◽  
Marcin Juchimiuk ◽  
...  

Colorectal cancer (CRC) is one of the most common malignancies. Despite the availability of diagnostic tests, an increasing number of new cases is observed. That is why it is very important to search new markers that would show high diagnostic utility. Therefore, we made an attempt to assess the usefulness of eotaxins, as there are few studies that investigate their significance, in patients with CRC. The study included 80 subjects (CRC patients and healthy volunteers). Serum concentrations of all eotaxins were measured using a multiplexing method (Luminex), while CCR3 was measured by immunoenzymatic assay (ELISA). CRP levels were determined by immunoturbidimetry and classical tumor marker levels (CEA and CA 19-9) and were measured using chemiluminescent microparticle immunoassay (CMIA). The highest usefulness among the proteins tested showed CCR3. Its concentrations were significantly higher in the CRC group than in healthy controls. The diagnostic sensitivity, specificity, positive and negative predictive value, and the area under the ROC curve (AUC) of CCR3 were higher than those of CA 19-9. The maximum values for sensitivity, negative predictive value, and AUC were obtained for a combination of CCR3 and CRP. Our findings suggest the potential usefulness of CCR3 in the diagnosis of CRC, especially in combination with CRP or CEA.


2015 ◽  
Vol 100 (5) ◽  
pp. 962-965 ◽  
Author(s):  
Ahmet Türkoğlu ◽  
Mesut Gül ◽  
Abdullah Oğuz ◽  
Zübeyir Bozdağ ◽  
Burak Veli Ülger ◽  
...  

Our objective for this study was to discuss the usability of mean platelet volume, which is associated with numerous vascular pathologies, in the early diagnosis of acute mesenteric ischemia. Acute mesenteric ischemia is an uncommon, life-threatening clinical condition mostly seen in the elderly. Early diagnosis of acute mesenteric ischemia and correction of blood circulation before necrosis occurs are important factors affecting prognosis. A total of 95 patients who underwent emergency surgery for acute mesenteric ischemia and 90 healthy volunteers as control group were included in this study. Age, gender, hemoglobin values, white blood cell counts, mean platelet volume, and platelet counts are recorded for evaluation. The mean platelet volume values were significantly higher in patients with acute mesenteric ischemia than in the controls (9.4 ± 1.1 fL and 7.4 ± 1.4 fL, respectively; P &lt; 0.001). Receiver-operating characteristic analysis demonstrated a cutoff value of mean platelet volume as 8.1 fL (area under the curve, 0.862), a sensitivity of 83.2%, and a specificity of 80%. As a result, in the patients who are admitted to the hospital with acute nonspecific abdominal pain and suspected of having acute mesenteric ischemia, high mean platelet volume values in routine hemograms support the diagnosis of acute mesenteric ischemia.


Diagnostics ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. 109 ◽  
Author(s):  
Ukweh ◽  
Ugbem ◽  
Okeke ◽  
Ekpo

Background: Ultrasound is operator-dependent, and its value and efficacy in fetal morphology assessment in a low-resource setting is poorly understood. We assessed the value and efficacy of fetal morphology ultrasound assessment in a Nigerian setting. Materials and Methods: We surveyed fetal morphology ultrasound performed across five facilities and followed-up each fetus to ascertain the outcome. Fetuses were surveyed in the second trimester (18th–22nd weeks) using the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guideline. Clinical and surgical reports were used as references to assess the diagnostic efficacy of ultrasound in livebirths, and autopsy reports to confirm anomalies in terminated pregnancies, spontaneous abortions, intrauterine fetal deaths, and still births. We calculated sensitivity, specificity, positive and negative predictive values, Area under the curve (AUC), Youden index, likelihood ratios, and post-test probabilities. Results: In total, 6520 fetuses of women aged 15–46 years (mean = 31.7 years) were surveyed. The overall sensitivity, specificity, and AUC were 77.1 (95% CI: 68–84.6), 99.5 (95% CI: 99.3–99.7), and 88.3 (95% CI: 83.7–92.2), respectively. Other performance metrics were: positive predictive value, 72.4 (95% CI: 64.7–79.0), negative predictive value, 99.6 (95% CI: 99.5–99.7), and Youden index (77.1%). Abnormality prevalence was 1.67% (95% CI: 1.37–2.01), and the positive and negative likelihood ratios were 254 (95% CI: 107.7–221.4) and 0.23 (95% CI: 0.16–0.33), respectively. The post-test probability for positive test was 72% (95% CI: 65–79). Conclusion: Fetal morphology assessment is valuable in a poor economics setting, however, the variation in the diagnostic efficacy across facilities and the limitations associated with the detection of circulatory system anomalies need to be addressed.


2019 ◽  
Vol 90 (e7) ◽  
pp. A2.3-A3
Author(s):  
Hue Mun Au Yong ◽  
Erica Minato ◽  
Eldho Paul ◽  
Udaya Seneviratne

IntroductionThis study aims to (i)evaluate the diagnostic sensitivity, specificity and predictive values of seizure-related heart rate (HR) in differentiating epileptic seizures(ES) from psychogenic non-epileptic seizures(PNES), (ii)define the most useful point of HR measurement: pre-ictal, ictal-onset, maximal-ictal or post-ictal, and (iii)define the HR cut-off points to differentiate ES from PNES.MethodsAll video EEG(VEEG) at Monash Health from May 2009 to November 2015 were retrospectively reviewed. Baseline(during wakefulness), one-minute pre-ictal, ictal-onset, maximal-ictal and one-minute post-ictal HR were measured for each ES and PNES event. Events less than ten seconds or with uninterpretable ECG due to artefacts were excluded. ROC curve analysis was performed to study the diagnostic accuracy reflected by area under the curve(AUC). The AUC was interpreted as follows; ≤0.5, differentiation of PNES from ES no better than chance; 0.80–0.89, good differentiation; and 0.9–1, excellent differentiation.ResultsVEEG of 341 ES and 265 PNES from 130 patients were analysed. The AUC for pre-ictal, ictal-onset, maximal-ictal and post-ictal HR were found to have poor differentiation between ES and PNES. Comparing PNES and bilateral tonic-clonic ES, AUC for absolute maximal-ictal HR was 0.84(CI 0.73–0.95) and for absolute post-ictal HR was 0.90(CI 0.81–1.00). Using Youden’s index, to diagnose tonic-clonic ES, the optimal cut-off point for absolute maximal-ictal HR was 114bpm (sensitivity 84%;specificity 82%;PPV 26.7%,NPV 98.5%) and for absolute post-ictal HR was 90bpm(sensitivity 91%;specificity 82%;PPV 30.3%;NPV 99.1%).ConclusionsThese findings suggest that seizure-related HR increase is useful in differentiating bilateral tonic-clonic ES from PNES. Based on the AUC, the best diagnostic measureme.


Author(s):  
Lin Yang ◽  
Meng Dai ◽  
Qinglin Cao ◽  
Shuai Ding ◽  
Zhanqi Zhao ◽  
...  

Hypoxia poses a serious threat to pilots. The aim of the study was to examine the efficacy of electrical bioimpedance (EBI) in detecting the onset of hypoxia in real time in a rabbit hypoxia model. Thirty-two New Zealand rabbits were divided equally into four groups (control group and 3 hypoxia groups, i.e. mild, moderate and severe). Hypoxia was induced by simulating various altitudes in the hypobaric oxygen chamber (3000 m, 5000 m and 8000 m). Both cerebral impedance and blood oxygen (SaO2) were monitored continuously. Results showed that the cerebral impedance increased immediately during the period of increasing altitude and decreased quickly to the initial baseline at the phase of descending altitude. Moreover, the change of cerebral impedance in mild hypoxia group (3000 m) is significantly smaller than those in the other two groups (5000 m and 8000 m, P<0.05). The changes of cerebral impedance and SaO2 were significantly correlated based on the total of measurement data (R2=0.628, P<0.001). Further, the agreement analysis performed with Bland-Altman and standardized residual plots exhibited high concordance between cerebral impedance and SaO2. Receiver operator characteristic analysis manifested that the sensitivity, specificity and area under the curve using cerebral impedance for changes of SaO2 >10% were 0.735, 0.826 and 0.845, respectively. These findings demonstrated that EBI could sensitively and accurately monitor changes of cerebral impedance induced by hypoxia, which might provide a potential tool for the real-time and non-invasive monitoring of hypoxic condition of pilots in flight for early identification of hypoxia.


Sign in / Sign up

Export Citation Format

Share Document