scholarly journals Assessment of Current Energy Consumption in Residential Buildings in Jeddah, Saudi Arabia

Buildings ◽  
2019 ◽  
Vol 9 (7) ◽  
pp. 163 ◽  
Author(s):  
Ahmed Felimban ◽  
Alejandro Prieto ◽  
Ulrich Knaack ◽  
Tillmann Klein ◽  
Yasser Qaffas

In the Kingdom of Saudi Arabia (KSA), residential buildings’ energy consumption accounts for almost 50% of the building stock electricity consumption. The KSA’s economy relies heavily on fossil fuel sources, namely oil reservoirs, whose depletion will negatively affect the future development of the country. The total electricity consumption is growing by approximately 5–8% annually, which would lead to oil production and oil consumption being equal in 2035. Therefore, residential buildings need further assessment as regards their current energy consumption. This research used a survey to explore current user behaviour in residential buildings’ energy performance in the city of Jeddah, KSA. The findings of the survey show that several factors impact the energy performance in residential buildings. First, the buildings’ thermal properties were found to be poorly designed. Second, the cultural aspects (family member role and generous hospitality), and the majority of users within the buildings preferring a room temperature of below 24 °C, requires a massive amount of cooling due to the climate conditions. Third, an increase in user awareness has helped to slightly improve residential buildings’ energy efficiency. Knowing the current high-energy-consumption sources and causes, being able to define opportunities for thermal properties’ enhancement, and increasing user awareness of how to achieve self-sustaining buildings are essential.

Author(s):  
Ahmed Felimban ◽  
Alejandro Prieto ◽  
Ulrich Knaack ◽  
Tillmann Klein ◽  
Yasser Qaffas

In the Kingdom of Saudi Arabia (KSA), residential buildings’ energy consumption accounts for almost 50% of the building stock electricity consumption. The electricity generation consumes over one-third of the daily oil production. KSA was ranked as one of the highest countries in fossil fuel consumption per capita in 2014. Moreover, the KSA’s economy heavily relies on fossil fuel sources, namely oil reservoirs, whereby depletion will negatively affect the future development of the country. The total electricity consumption is annually growing by approximately 5-8%, which would lead to identical oil consumption to oil production in 2035. Currently, the KSA government is concerned to generate more renewable energy using large renewable energy plants. The government is investing in energy generation through renewable sources, by financing large scale photovoltaic farms to stop an economic crisis that may occur in 2035. The existing building stock consumes around 80% of the total current Saudi electricity that is generated. According to the Saudi energy efficiency report, the primary energy consumption per capita is over three times higher than the world average. Therefore, the residential buildings need further assessment as to their current energy consumption. This research used a survey to explore current user behaviour in residential buildings energy performance in the city of Jeddah, KSA. The findings of the survey showed: • The buildings thermal properties were found to be poorly designed • The majority of users within the buildings prefer a room temperature of below 24 °C, which requires a massive amount of cooling • Due to the climate conditions and the cultural aspects of KSA, housing units are occupied for more than 18 hours per day • An increase in user awareness has helped to slightly improve residential buildings energy efficiency Knowing the current high energy consumption sources and causes and being able to define available opportunities for further developments on building thermal properties enhancements and how to increase user awareness to reach self-sustaining buildings is essential.


2020 ◽  
pp. 014459872097514
Author(s):  
AbdulRahman S Almushaikah ◽  
Radwan A Almasri

Lately, with the growth in energy consumption worldwide to support global efforts to improve the climate, developing nations have to take significant measures. Kingdom of Saudi Arabia (KSA) implemented meaningful policy actions towards promoting energy efficiency (EE) in several sectors, especially in the building sector, to be more sustainable. In this paper, various EE measures and solar energy prospects are investigated for the residential sector, in two locations in the middle region of the KSA. An energy performance analysis of pre-existing residential buildings with an overall design is performed using simulation programs. However, installing EE measures in the building envelope is important to achieve an efficient sector regarding its energy consumption. The findings showed that applying EE measures for the building envelope, walls, roof, and windows should be considered first that makes the energy conservation possible. In Riyadh, EE measures are responsible for reducing energy consumption by 27% for walls, 14% for roof, and 6% for window, and by 29%, 13%, and 6% for walls, roof, and windows, respectively, for Qassim. However, the most impactful EE solution was selecting a heating, ventilation, and air conditioning (HVAC) system with a high energy efficiency rate (EER), which can minimize the energy consumption by 33% and 32% for Riyadh and Qassim, respectively. The study's feasibility showed that the number of years needed to offset the initial investment for a proposed roof PV system exceeds the project's life, if the energy produced is exported to the grid at the official export tariff of 0.019 $/kWh. However, the simple payback time was 13.42 years if the energy produced is exported to the grid at a rate of 0.048 $/kWh, reflecting the project's economic feasibility.


Energies ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 87 ◽  
Author(s):  
Jubran Alshahrani ◽  
Peter Boait

Electricity consumption in the Kingdom of Saudi Arabia (KSA) has grown at an annual rate of about 7% as a result of population and economic growth. The consumption of the residential sector accounts for over 50% of the total energy generation. Moreover, the energy consumption of air-conditioning (AC) systems has become 70% of residential buildings’ total electricity consumption in the summer months, leading to a high peak electricity demand. This study investigates solutions that will tackle the problem of high energy demand associated with KSA’s air-conditioning needs in residential buildings. To reduce the AC energy consumption in the residential sector, we propose the use of smart control in the thermostat settings. Smart control can be utilized by (i) scheduling and advance control of the operation of AC systems and (ii) remotely setting the thermostats appropriately by the utilities. In this study, we model typical residential buildings and, crucially, occupancy behavior based on behavioral data obtained through a survey. The potential impacts in terms of achievable electricity savings of different AC operation modes for residential houses of Riyadh city are presented. The results from our computer simulations show that the solutions intended to reduce energy consumption effectively, particularly in the advance mode of operation, resulted in a 30% to 40% increase in total annual energy savings.


2021 ◽  
Vol 13 (24) ◽  
pp. 13934
Author(s):  
Hanan S. S. Ibrahim ◽  
Ahmed Z. Khan ◽  
Yehya Serag ◽  
Shady Attia

Retrofitting “nearly-zero energy” heritage buildings has always been controversial, due to the usual association of the “nearly-zero energy” target with high energy performance and the utilization of renewable energy sources in highly regarded cultural values of heritage buildings. This paper aims to evaluate the potential of turning heritage building stock into a “nearly-zero energy” in hot, dry climates, which has been addressed in only a few studies. Therefore, a four-phase integrated energy retrofitting methodology was proposed and applied to a sample of heritage residential building stock in Egypt along with microscale analysis on buildings. Three reference buildings were selected, representing the most dominant building typologies. The study combines field measurements and observations with energy simulations. In addition, simulation models were created and calibrated based on monitored data in the reference buildings. The results show that the application of hybrid passive and active non-energy generating scenarios significantly impacts energy use in the reference buildings, e.g., where 66.4% of annual electricity use can be saved. Moreover, the application of solar energy sources approximately covers the energy demand in the reference buildings, e.g., where an annual self-consumption of electricity up to 78% and surplus electricity up to 20.4% can be achieved by using photo-voltaic modules. Furthermore, annual natural gas of up to 66.8% can be saved by using two unglazed solar collectors. Lastly, achieving “nearly-zero energy” was possible for the presented case study area. The originality of this work lies in developing and applying an informed retrofitting (nearly-zero energy) guide to be used as a benchmark energy model for buildings that belong to an important historical era. The findings contribute to fill a gap in existing studies of integrating renewable energy sources to achieve “nearly-zero energy” in heritage buildings in hot climates.


Energies ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 5836
Author(s):  
Ali Mohammed AL-Dossary ◽  
Daeung Danny Kim

In Saudi Arabia, residential buildings are one of the major contributors to total energy consumption. Even though there are abundant natural resources, it is somewhat difficult to apply them to building designs, as design variables, due to slow progress and private issues in Saudi Arabia. Thus, the present study demonstrated the development of sustainable residential building design by examining the daylighting and energy performance with design variables. Focusing on the daylighting system, the design variables were chosen, including window-to-wall ratios (WWR), external shading devices, and types of glazing. The illuminance level by these design variables in a building was evaluated by using daylight metrics, such as spatial daylight autonomy and annual sunlight exposure. Moreover, the building energy consumption with these design variables was analyzed by using energy simulation. As a result, the daylighting was improved with the increase in WWRs and the tinted double glazing, while these design options can cause overheating in a residential building. Among types of glazing, the double pane windows with a low-E coating showed better energy performance. Based on the results, it is necessary to find the proper design variables that can balance the daylighting and energy performance in residential buildings in hot climates.


2020 ◽  
Vol 24 (3) ◽  
pp. 278-293
Author(s):  
Jan Kaselofsky ◽  
Ralf Schüle ◽  
Marika Rošā ◽  
Toms Prodaņuks ◽  
Anda Jekabsone ◽  
...  

AbstractNon-residential buildings in the European Union consume more than one third of the building sector’s total. Many non-residential buildings are owned by municipalities. This paper reports about an energy saving competition that was carried out in 91 municipal buildings in eight EU member states in 2019. For each public building an energy team was formed. The energy teams’ activities encompassed motivating changes in the energy use behaviour of employees and small investments. Two challenges added an element of gamification to the energy saving competition. To assess the success of the energy saving competition, an energy performance baseline was calculated using energy consumption data of each public building from previous years. Energy consumption in the competition year was monitored on a monthly base. After the competition the top energy savers from each country were determined by the percentage-based reduction of energy consumption compared to the baseline. On average, the buildings had an electricity and heat consumption in 2019 that was about 8 % and 7 %, respectively, lower than the baseline. As an additional data source for the evaluation, a survey among energy team members was conducted at the beginning and after the energy competition. Support from superiors, employee interest and motivation and behaviour change as assessed by energy team members show a positive, if weak or moderate, correlation with changes in electricity consumption, but not with changes in heat consumption.


2021 ◽  
Vol 65 (1) ◽  
pp. 83-92
Author(s):  
Valeria Todeschi ◽  
Simone Beltramino ◽  
Bernadette El Jamous ◽  
Guglielmina Mutani

Nowadays, energy consumption in buildings is one of the fundamental drivers to control greenhouse gas emissions and environmental impact. In fact, the air quality of urban environments can cause two main phenomena in metropolitan areas: urban heat island and climate changes. The aim of this work is to showcase how different building variables can impact the residential building’s space heating and cooling energy consumption. Buildings energy-related variables can be fundamental viewpoints to improve the energy performance of neighborhoods, especially in future urban planning. This work examines four neighborhoods in the city of Turin (IT): Arquata, Crocetta, Sacchi, and Olympic Village characterized by different morphologies and building typologies. In each neighborhood, residential building was grouped according to orientations and construction periods. A sensitivity analysis was applied by analysing six building variables: infiltration rate, window-to-wall ratio, and windows, walls, roofs, and floor thermal transmittances. The energy consumption for space heating and cooling of residential buildings and local climate conditions were investigated using CitySim Pro tool and ENVI-met. The challenge of this work is to identify the building variables that most influence energy consumption and to understand how to promote high-energy efficiency neighborhoods: the goal is to identify the “ideal” urban form with low consumption and good comfort conditions in outdoor urban environments. The results of this work show a significant connection between the energy consumption and the six analyzed building variables; however, this relationship also depends on the shape and orientation of the neighborhood.


Clean Energy ◽  
2021 ◽  
Vol 5 (3) ◽  
pp. 423-432
Author(s):  
Rakesh Dalal ◽  
Kamal Bansal ◽  
Sapan Thapar

Abstract The residential-building sector in India consumes >25% of the total electricity and is the third-largest consumer of electricity; consumption increased by 26% between 2014 and 2017. India has introduced a star-labelling programme for residential buildings that is applicable for all single- and multiple-dwelling units in the country for residential purposes. The Energy Performance Index (EPI) of a building (annual energy consumption in kilowatt-hours per square metre of the building) is taken as an indicator for awarding the star label for residential buildings. For gauging the EPI status of existing buildings, the electricity consumption of residential buildings (in kWh/m2/year) is established through a case study of the residential society. Two years of electricity bills are collected for an Indian residential society located in Palam, Delhi, analysed and benchmarked with the Indian residential star-labelling programme. A wide EPI gap is observed for existing buildings for five-star energy labels. Based on existing electricity tariffs, the energy consumption of residential consumers and the Bureau of Energy Efficiency (BEE)’s proposed building ENERGY STAR labelling, a grid-integrated rooftop solar photovoltaic (PV) system is considered for achieving a higher star label. This research study establishes the potential of grid-connected rooftop solar PV systems for residential buildings in Indian cities through a case study of Delhi. Techno-economic analysis of a grid-integrated 3-kWp rooftop solar PV plant is analysed by using RETScreen software. The study establishes that an additional two stars can be achieved by existing buildings by using a grid-integrated rooftop solar PV plant. Payback for retrofit of a 3-kWp rooftop solar PV plant for Indian cites varies from 3 to 7 years. A case study in Delhi, India establishes the potential of grid-connected rooftop solar PV systems for residential buildings. Techno-economic analysis of grid integrated, 3 kWp rooftop solar systems estimates a payback period from 3 to 7 years.


2014 ◽  
Vol 899 ◽  
pp. 16-23
Author(s):  
Tamás Csoknyai

The residential buildings built with prefabricated technology (also called panel buildings) represent a significant part of the building stock, particularly in Eastern Europe. These buildings are typically 30-40 years old and due to their poor energy performance they have been in the focus of energy policy makers over the recent years. These buildings are typically connected to district heating systems and the continuously decreasing heat demand caused by the renovation subsidy programs resulting in risks of inefficient operation and on the long term it questions the viability of the district heating systems. Therefore it is particularly important to have a clear picture on the energy consumption trends about this segment of the building stock. In this paper, the building stock of the city of Debrecen connected to district heating is analysed. The current energy consumption figures of the buildings are analysed. In Debrecen, the share of retrofitted buildings is relatively low (appr. 15%), therefore a future trend analysis was also carried out. The results of this study can be interesting for other cities as well, particularly those with a significant share of “panel buildings”.


Author(s):  
Khuram Pervez Amber ◽  
Muhammad Waqar Aslam ◽  
Anila Kousar ◽  
Muhammad Sajid Khan ◽  
Ghulam Qadir Chaudhary ◽  
...  

Abstract Energy usage intensity (EUI, kWh/m2/year) of a building category helps energy managers and building owners in evaluating the energy performance of their buildings. Banks are energy-intensive buildings, but there is limited research published in this highly energy-intensive building category. In this paper, the energy consumption of 98 bank buildings located in different cities of the AJK region of Pakistan has been critically analyzed and their EUI value has been established. Data were collected through site visits, interviews, and questionnaires. Electricity consumption of each bank branch was normalized using the cooling degree days method and respective annual normalized EUIs were calculated. It was found through analysis that three major factors that drive electricity consumption in bank buildings in Pakistan are building's area, the number of workstations, and the number of automatic teller machines. The EUI of banks in Pakistan has been found to be 222 kWh/m2/yr, which is comparable with the same of eight other countries.