scholarly journals Usefulness of Acoustic Sounds from 3D Printers in an Eavesdropping Process and Reconstruction of Printed Shapes

Electronics ◽  
2020 ◽  
Vol 9 (2) ◽  
pp. 297
Author(s):  
Ireneusz Kubiak ◽  
Artur Przybysz ◽  
Andrzej Stańczak

Information protection is an essential safety issue in many human activity fields. The development of computerisation (informatisation) brings new challenges in the area of non-invasive information processing in information technology (IT) systems. The known fact is that VGA, DVI/HDMI interfaces, for example, or formatter systems of laser printers that process video signals are sources of effective disclosing electromagnetic emission. Emission safety of the more and more common three-dimensional (3D) printers is less known. The selected 3D printer with the ME3DP (Material Extrusion 3D Printing) technology was tested to analyse the existing risk. Simple objects were printed during its operation to identify the stepping motor operation that are emission sources in the secondary channels. The analysis carried out focused on finding the correlation between the registered emissions and the printer head (printhead) movements when printing an object. It was shown that the analysis of the registered sensitive signal runtimes and their spectrograms allows us to recreate the printed object shape. The studies focused on measuring the acoustic signals that came from the stepping motors. The analysis of the possibilities of identifying the shapes of printed objects was based on the visual method. The article presents the study results and their analyses.

2020 ◽  
Vol 318 ◽  
pp. 01018
Author(s):  
Athanasios Argyropoulos ◽  
Pantelis N. Botsaris

The aim of this research study centers around the design and development, using a three-dimensional model of an ear-splint. This study results from the need of a non-invasive method, as the current techniques used in otoplasty have succeeded in reducing the risk of complications, but without drastically reducing the rate of postoperative deformity. Indeed, stick out ears present a deformity that occurs in 5% of the population. Factors such as psychosocial impact and intimidation lay the foundations for the need for such a method. This paper essays to create, through 3D printing, a case customized into the ear of any person of all ages. The splint was made on Zortrax M200 3D printer model, equipped with the V3 Hotend head, and the material used for printing was 16 grams of Z-FLEX. It is noted that the creation of the case is innovative and original. After putting the ear-splint into test, by applying it on a human ear, two conclusions emerge. First, it is very light, weight, just 16 grams, and second, it offers comfort and convenience to the user. In order to get results for its practicality, a clinical rehabilitation study is recommended.


2021 ◽  
Vol 11 (11) ◽  
pp. 5305
Author(s):  
Andrzej Stańczak ◽  
Ireneusz Kubiak ◽  
Artur Przybysz ◽  
Anna Witenberg

Information protection is an important safety issue in many human activity fields. Technological advances and related ubiquitous computerization bring new challenges in this area. In particular, the problem concerns the protection of devices against non-invasive acquisition processed information in ICT systems. It is known that, e.g., VGA, DVI/HDMI interfaces or laser printer formatter systems that process visual signals are the effective sources of compromising electromagnetic emanations. The emission safety of the more and more commonly used 3D printers is less known. In many cases, the disclosure of information about printed objects might constitute an infringement of the state/industrial/commercial secret, copyright, patent protection, etc. In order to analyze the existing threat, a selected printer using FDM technology was tested. During the tests, simple objects were printed to identify the operation of the stepper motor and the movements of the printer head and the printer platform, which are sources of emissions in the secondary channels. The analyses performed focused on finding the correlation between the recorded vibration signals and the printer head movements when an object was printed. It was shown that the analysis of the registered sensitive signal runtimes and their spectrograms allowed to recreate the printed object shape. Three simple objects (a trihedron, a tube and a tetrahedron) were selected for testing because they include elements that allow the four major movements of the printer head to be easily recognized: along the X axis, along the Y axis, along an arc and diagonally (between the X and Y axes). The paper presents the test results and their analyses.


Author(s):  
H.W. Deckman ◽  
B.F. Flannery ◽  
J.H. Dunsmuir ◽  
K.D' Amico

We have developed a new X-ray microscope which produces complete three dimensional images of samples. The microscope operates by performing X-ray tomography with unprecedented resolution. Tomography is a non-invasive imaging technique that creates maps of the internal structure of samples from measurement of the attenuation of penetrating radiation. As conventionally practiced in medical Computed Tomography (CT), radiologists produce maps of bone and tissue structure in several planar sections that reveal features with 1mm resolution and 1% contrast. Microtomography extends the capability of CT in several ways. First, the resolution which approaches one micron, is one thousand times higher than that of the medical CT. Second, our approach acquires and analyses the data in a panoramic imaging format that directly produces three-dimensional maps in a series of contiguous stacked planes. Typical maps available today consist of three hundred planar sections each containing 512x512 pixels. Finally, and perhaps of most import scientifically, microtomography using a synchrotron X-ray source, allows us to generate maps of individual element.


2012 ◽  
Vol 153 (40) ◽  
pp. 1570-1577 ◽  
Author(s):  
Attila Nemes ◽  
Anita Kalapos ◽  
Péter Domsik ◽  
Tamás Forster

Three-dimensional speckle-tracking echocardiography is a new cardiac imaging methodology, which allows three-dimensional non-invasive evaluation of the myocardial mechanics. The aim of this review is to present this new tool emphasizing its diagnostic potentials and demonstrating its limitations, as well. Orv. Hetil., 2012, 153, 1570–1577.


2015 ◽  
Vol 11 (1) ◽  
pp. 2897-2908
Author(s):  
Mohammed S.Aljohani

Tomography is a non-invasive, non-intrusive imaging technique allowing the visualization of phase dynamics in industrial and biological processes. This article reviews progress in Electrical Capacitance Volume Tomography (ECVT). ECVT is a direct 3D visualizing technique, unlike three-dimensional imaging, which is based on stacking 2D images to obtain an interpolated 3D image. ECVT has recently matured for real time, non-invasive 3-D monitoring of processes involving materials with strong contrast in dielectric permittivity. In this article, ECVT sensor design, optimization and performance of various sensors seen in literature are summarized. Qualitative Analysis of ECVT image reconstruction techniques has also been presented.


2019 ◽  
pp. 1-2

A study of of endometrial thickness on TVS in relation with histopathology report on dilation and curettage. AIM AND OBJECTIVE-To set a cut off limit of endometrial thickness on TVS for differtiating between normal and abnormal endometrium. MATERIAL AND METHOD-hospital based comparative study. RESULTS-TVS is non invasive ,simple first line procedure in AUB women. Mean endometrial thickness in normal endometrial group was 8.00±2.44 mm and in abnormal endometrial group was 15.16±33 mm.The difference was found highly significant (p value<.001)


2019 ◽  
Vol 11 (6) ◽  
pp. 168781401985284
Author(s):  
Meiliang Wang ◽  
Mingjun Wang ◽  
Xiaobo Li

The use of the traditional fabric simulation model evidently shows that it cannot accurately reflect the material properties of the real fabric. This is against the background that the simulation result is artificial or an imitation, which leads to a low simulation equation. In order to solve such problems from occurring, there is need for a novel model that is designed to enhance the essential properties required for a flexible fabric, the simulation effect of the fabric, and the efficiency of simulation equation solving. Therefore, the improvement study results will offer a meaningful and practical understanding within the field of garment automation design, three-dimensional animation, virtual fitting to mention but a few.


Heliyon ◽  
2021 ◽  
Vol 7 (4) ◽  
pp. e06645
Author(s):  
Charlotte Theresa Trebing ◽  
Sinan Sen ◽  
Stefan Rues ◽  
Christopher Herpel ◽  
Maria Schöllhorn ◽  
...  

Author(s):  
L Epprecht ◽  
L Qingsong ◽  
N Stenz ◽  
S Hashimi ◽  
T Linder

Abstract Objective Ventilation of the middle ear and mastoid air cells is believed to play an important role in the pathogenesis of chronic ear disease. Traditionally, ventilation is assessed by computed tomography. However, this exposes patients to cumulative radiation injury. In cases with a perforation in the tympanic membrane, tympanometry potentially presents a non-invasive alternative to measure the ventilated middle-ear and mastoid air cell volume. This study hypothesised that total tympanometry volume correlates with ventilated middle-ear and mastoid air cell volume. Method Total tympanometry volume was compared with ventilated middle-ear and mastoid air cell volume on computed tomography scans in 20 tympanic membrane perforations. Results There was a high correlation between tympanometry and computed tomography volumes (r = 0.78; p < 0.001). A tympanometry volume more than 2 ml predicted good ventilation on computed tomography. Conclusion These results may help reduce the need for pre-operative computed tomography in uncomplicated cases with tympanic membrane perforations.


Sign in / Sign up

Export Citation Format

Share Document