scholarly journals A Study of the Effects of Enhanced Uniformity Control of Greenhouse Environment Variables on Crop Growth

Energies ◽  
2019 ◽  
Vol 12 (9) ◽  
pp. 1749 ◽  
Author(s):  
Chan Kyu Lee ◽  
Mo Chung ◽  
Ki-Yeol Shin ◽  
Yong-Hoon Im ◽  
Si-Won Yoon

In order to ensure high crop yield and good quality in greenhouse horticulture, the major environment control variables, such as temperature, humidity, and CO2 concentration, etc., need to be controlled properly, in order to reduce harmful effects on crop growth by minimizing the fluctuation of the thermal condition. Even though a hot water-based heating system is evidently superior to a hot air-based heating system, in terms of the thermally stable condition or energy saving, a hot air-based heating system has occupied the domestic market due to its economic efficiency from an initial investment cost saving. However, the intrinsic drawbacks of a hot air-based heating system, being more frequent variation of thermal variables and an inordinate disturbance on crops due to its convective heat delivery nature, are believed to be the main reasons for the insufficient crop yield and/or the quality deterioration. In addition, the current thermal environment monitoring system in a greenhouse, in which a sole sensor node usually covers a large part of cultivating area, seems to have a profound need of improvement in order to resolve those problems, in that the assumption of thermal uniform condition, which is adequate for a sole sensor node system, cannot be ensured in some cases. In this study, the qualitative concept of the new control variable—the degree of uniformity—is suggested as an indicator to seek ways of enhancing the crop yield and its quality based on the multiple sensor nodes system with a wireless sensor network. In contrast to a conventional monitoring system, for which a newly suggested concept of qualitative variable cannot be estimated at all, the multiple sensor nodes-based thermal monitoring system can provide more accurate and precise sensing, which enables the degree of uniformity to be checked in real-time and thus more precise control becomes possible as a consequence. From the analysis of the results of the experiment and simulation, it is found that the crops in plastic vinyl houses can be exposed to a serious level of non-uniform thermal condition. For instance, the temperature difference in the longitudinal and widthwise direction is 3.0 °C and 6.5 °C, respectively for the case of 75 × 8 m dimension greenhouse during a typical winter season, and it can be hypothesized that this level of non-uniformity might cause considerable damage to crop growth. In this paper, several variants of control systems, within the framework of the multiple sensor nodes system, is proposed to provide a more thermally-stable cultivating environment and the experimental verification is carried out for different scales of test greenhouses. The results showed that a simple change of heating mode (i.e., from a hot air- to a hot water-based heating system) can bring about a significant improvement for the non-uniformity of temperature (more or less 80%), and an additional countermeasure, with local heat flux control, can lead to a supplementary cut of non-uniformity up to 90%. Among the several variants of local heat flux control systems, the hydraulic proportional mass flow control valve system was proven to represent the best performance, and it can be hypothesized that the newly suggested qualitative variable—the degree of uniformity—with the multiple sensor nodes system can be a good alternative for seeking enhanced cultivating performance, being higher crop yield and better quality along with energy cost saving.

2020 ◽  
Vol 180 ◽  
pp. 03022
Author(s):  
Eugen Marin ◽  
Marinela Mateescu ◽  
Dragos Manea ◽  
Andrei Dumitrascu ◽  
Carmen Vasilachi ◽  
...  

Considerating that the energy resources can be found in limited quantities and are not renewable, the most efficient and technically sustainable for heating the soil in early spring or late autumn in a greenhouse for vegetables is to use the solar energy. A heated greenhouse for vegetables is useful because the vegetation process can start more early or can continue later for can obtain several crops throughout the year. The paper presents theoretical researches accomplished for development an system of ecological heating in a greenhouse covered with a tough polyethylene wrap with triple layer. The heating system contains solar panels with heat-pipe vacuum tubes and an installation for heating the interior of the solarium using hot water hot air heaters, which adds more heat.


Author(s):  
F. A. Saparudin ◽  
T. C. Chee ◽  
A. S. Ab Ghafar ◽  
H. A. Majid ◽  
N. Katiran

<span>Water quality is one of the major factors that greatly affects growth and mortality rate of aquatic livestock especially in high density aquaculture system.  Conventional method requires fish farmer to perform manual water quality test and record on multiple fish tanks in regular basis. This process is meticulous, and may affect aquatic livestock that needs close and immediate attention. In this paper, water quality monitoring system for the high density aquaculture environment is proposed. The monitoring system is composed of multiple sensor nodes and sensor/server node hybrid, which used to collect and manage the water quality parameter data of multiple tanks. The sensor nodes collect and store the water quality parameters in local database and transmit them to the server node through a wireless communication. The server node is used for data analysis, processing and allow public access via web browser through various Wi-Fi enabled smart devices. This paper presents a proof-of concept of clustered wireless monitoring system focused on the use of multiple sensor nodes to determine the water parameter in real time. This system is cost effective, quickly deployable, and user-friendly with wireless capabilities.</span>


HortScience ◽  
1994 ◽  
Vol 29 (4) ◽  
pp. 249a-249
Author(s):  
Eric A. Lavoie ◽  
Damien de Halleux ◽  
André Gosselin ◽  
Jean-Claude Dufour

The main objective of this research was to produce a simulated model that permitted the evaluation of operating costs of commercial greenhouse tomato growers with respect to heating methods (hot air, hot water, radiant and heat pumps) and the use of artificial lighting for 1991 and 1992. This research showed that the main factors that negatively influence profitability were energy consumption during cold periods and the price of tomatoes during the summer season. The conventional hot water system consumed less energy than the heat pump system and produced marketable fruit yields similar to those from the heat pump system. The hot water system was generally more profitable in regards to energy consumption and productivity. Moreover, investment costs were less; therefore, this system gives best overall financial savings. As for radiant and hot air systems, their overall financial status falls between that of the hot water system and the heat pump. The radiant system proved to be more energy efficient that the hot air system, but the latter produced a higher marketable fruit yield over the 2-year study.


2018 ◽  
Vol 14 (01) ◽  
pp. 4
Author(s):  
Wang Weidong

To improve the efficiency of the remote monitoring system for logistics transportation, we proposed a remote monitoring system based on wireless sensor network and GPRS communication. The system can collect information from the wireless sensor network and transmit the information to the ZigBee interpreter. The monitoring system mainly includes the following parts: Car terminal, GPRS transmission network and monitoring center. Car terminal mainly consists by the Zigbee microcontroller and peripherals, wireless sensor nodes, RFID reader, GPRS wireless communication module composed of a micro-wireless monitoring network. The information collected by the sensor communicates through the GPRS and the monitoring center on the network coordinator, sends the collected information to the monitoring center, and the monitoring center realizes the information of the logistics vehicle in real time. The system has high applicability, meets the design requirements in the real-time acquisition and information transmission of the information of the logistics transport vehicles and goods, and realizes the function of remote monitoring.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3350
Author(s):  
Theofanis Benakopoulos ◽  
William Vergo ◽  
Michele Tunzi ◽  
Robbe Salenbien ◽  
Svend Svendsen

The operation of typical domestic hot water (DHW) systems with a storage tank and circulation loop, according to the regulations for hygiene and comfort, results in a significant heat demand at high operating temperatures that leads to high return temperatures to the district heating system. This article presents the potential for the low-temperature operation of new DHW solutions based on energy balance calculations and some tests in real buildings. The main results are three recommended solutions depending on combinations of the following three criteria: district heating supply temperature, relative circulation heat loss due to the use of hot water, and the existence of a low-temperature space heating system. The first solution, based on a heating power limitation in DHW tanks, with a safety functionality, may secure the required DHW temperature at all times, resulting in the limited heating power of the tank, extended reheating periods, and a DH return temperature of below 30 °C. The second solution, based on the redirection of the return flow from the DHW system to the low-temperature space heating system, can cool the return temperature to the level of the space heating system return temperature below 35 °C. The third solution, based on the use of a micro-booster heat pump system, can deliver circulation heat loss and result in a low return temperature below 35 °C. These solutions can help in the transition to low-temperature district heating.


2012 ◽  
Vol 193-194 ◽  
pp. 30-33
Author(s):  
Xue Ying Wang ◽  
Dong Xu ◽  
Ya Jun Wu

This article analyzes the problem in application the solar system was used in residential building, puts forward the requirements to use energy and choose the setting of the solar energy collector from two aspects of building and drainage design respectively. In addition, the article explicates andthe solar energy collector and building integrated design and the development of solar energy collector. At last, the article puts forward some Suggestions on the improvement and development of residential solar hot water system and the design of the hot water supply bath solution of practice to make solar energy and low power assisted by night combining.


Sign in / Sign up

Export Citation Format

Share Document