scholarly journals Performance Analysis of a Combined Solar-Assisted Heat Pump Heating System in Xi’an, China

Energies ◽  
2019 ◽  
Vol 12 (13) ◽  
pp. 2515
Author(s):  
Huan ◽  
Li ◽  
Wang ◽  
Liu ◽  
Zhao ◽  
...  

This study proposed a combined solar-assisted heat pump (SAHP) system that could operate in the serial mode or parallel mode. For this proposed system, a stable year-round operation could be achieved without the assistance of electric heating or low-temperature heat pump. By analyzing the heat balance equations, a correlation of the combined SAHP system for the two modes switched was obtained, which provided a theoretical basis for the optimal operation of this system. In addition, the performance of the proposed system applied in a university bathroom in Xi’an district was investigated using TRNSYS. The results illustrated that compared to the serial and parallel systems, the proposed system exhibited a good performance on energy efficiency. The annual average coefficient of performance (COP) of the proposed system was 5.7, obviously higher than those of the serial system and the parallel system, which were 3.3 and 4.3, respectively. Therefore, the results in this study could provide the theoretical guidance and reference for practical engineering design.

1994 ◽  
Vol 116 (2) ◽  
pp. 88-93 ◽  
Author(s):  
E. Hahne ◽  
M. Hornberger

At Stuttgart University, a solar heating system for an office building with laboratories and lecture rooms was installed in 1985. It consists of 211 m2 of unglazed solar collectors, a 1050 m3 water-flooded pebble bed heat store, and a heat pump. Heat can be supplied to the store from the solar collectors or from a power station (as waste heat). The whole system has worked successfully for five years under varied strategies. In the first two heating periods, the heating strategy was aimed to collect as much solar energy as possible. Thus, about 60 percent of the heat demand could be covered by solar energy; but the yearly heat pump coefficient of performance (COP) was only around 2.76. With an improved heat pump, a monthly COP of 3.6 was obtained. Heat losses from the storage amounted to about 20 percent.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Akbar Alidadi Shamsabadi ◽  
Mehdi Jahangiri ◽  
Tayebeh Rezaei ◽  
Rouhollah Yadollahi Farsani ◽  
Ali Seryani ◽  
...  

Purpose In this study, a solar water heating system along with a seasonal thermal energy storage and a heat pump is designed for a villa with an area of 192 m2 in Tehran, the capital of Iran. Design/methodology/approach According to the material and the area of the residential space, the required heating of the building was calculated manually and then the thermodynamic analysis of the system and simulation was done in MATLAB software. Finally, regarding the waste of system, an efficient solar heating system, providing all the required energy to heat the building, was obtained. Findings The surface area of the solar collector is equal to 46 m2, the capacity of the tank is about 2,850 m3, insulation thickness stands at 55 cm and the coefficient of performance in required heat pump is accounted to about 9.02. Also, according to the assessments, the maximum level of received energy by the collector in this system occurs at a maximum temperature of 68ºC. Originality/value To the best of the authors’ knowledge, in the present work, for the first time, using mathematical modeling and analyzing of the first and second laws of thermodynamics, as well as using of computational code in MATLAB software environment, the solar-assisted ground source heat pump system is simulated in a residential unit located in Tehran.


Author(s):  
Yahya I. Sharaf-Eldeen

This work involves measurements, analyses, and evaluation of performance of air-source heat pump water heaters (HPWHs), and their impacts on electric utility loads. Two add-on, heat pumps (HPs) rated at 7000 BTU/h (2.051 kW) and 12,000 BTU/h (3.517 kW) were utilized. The HPs were retrofitted to two 50 gal (189.3 l) electric water heaters (EWHs) with their electric heating elements removed. A third standard EWH was used for comparison. The testing setups were fully instrumented for measurements of all pertinent parameters, including inlet and outlet water temperatures, inlet and outlet air temperatures of the HPs, temperature and humidity of the surrounding air, volume of water drawn out of the storage tanks, as well as the electric energy consumptions of the systems. Performance measures evaluated included the coefficient of performance, the energy factor (EF), and the first hour rating (FHR). The HPWH systems gave EFs ranging from 1.8 to 2.5 and corresponding energy savings (and reductions in utility peak loads) ranging from 49.0% to 63.0%, approximately. The values obtained in the summer months were, as expected, somewhat higher than those obtained in the winter ones. The average values of the EFs and energy savings (and reductions in utility peak loads) were about 2.1 and 56.0%, respectively. FHR results were much lower for the HPWHs compared with those for the standard EWH. These results show that HPWHs are much more efficient compared with standard EWHs. While the average value of the EF for the EWH was about 0.92, the HPWHs yielded EFs averaging more than 2.00, resulting in annual energy savings averaging more than 50%. The results also show that HPWHs are effective at reducing utility peak loads, in addition to providing substantial cost savings to consumers.


Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2642 ◽  
Author(s):  
Yi Zhang ◽  
Guanmin Zhang ◽  
Aiqun Zhang ◽  
Yinhan Jin ◽  
Ruirui Ru ◽  
...  

Frost layer on the outdoor air heat exchanger surface in an air-source heat pump (ASHP) can decrease the system coefficient of performance (COP). Although the common defrosting and anti-frosting methods can improve the COP, the periodic defrosting not only reduces the system energy efficiency but also deteriorates the indoor environment. To solve these problems, it is necessary to clearly understand the frosting phenomenon and to achieve the system frost-free operation. This paper focused firstly on the analyses of frosting pathways and frosting maps. Followed by summarizing the characteristics of frost-free technologies. And then the performances of two types of frost-free ASHP (FFASHP) systems were reviewed, and the exergy and economic analysis of a FFASHP heating system were carried out. Finally, the existing problems related to the FFASHP technologies were proposed. Results show that the existing frosting maps need to be further improved. The FFASHP systems can not only achieve continuous frost-free operation but reduce operating cost. And the total COP of the FFASHP heating system is approximately 30–64% higher than that of the conventional ASHP system under the same frosting conditions. However, the investment cost of the FFASHP system increases, and its reliability also needs further field test in a wider frosting environment. In the future, combined with a new frosting map, the control strategy for the FFASHP system should be optimized.


Author(s):  
Yahya I. Sharaf-Eldeen ◽  
Craig V. Muccio ◽  
Eric Gay

This work involves measurements, analyses, and evaluations of the performance of add-on, Heat Pump Water Heater (HPWH) systems in residential and small commercial applications. Two air-source Heat Pump (HP) systems rated at 7,000- and 12,000-BTU (2.051- and 3.517-kWh), were utilized in this work. The two HPs were retrofitted to two 50-gallon (189.3 liters) electric-resistance storage water-heaters with their electric heating elements removed. A third, standard electric water-heater (EWH), was used for comparison. The testing set-up was fully instrumented for measurements of pertinent parameters, including inlet and outlet water temperatures, inlet and outlet air temperatures of the HPs, temperature and humidity of the air in the surrounding space, volume of water draws out of the storage heater tanks, as well as electric energy consumptions of the systems. Several performance measures were used in this work, including the Coefficient of Performance (COP), which is a measure of the instantaneous energy output in comparison with the energy input; Energy Factor (EF), which is an average measure of the COP taken over extended periods of time; and the First Hour Rating (FHR), which is a measure of the maximum volume of hot water that a storage type water-heater can supply to a residence within an hour. The results obtained clearly indicate that, HPWH systems are much more efficient as compared to standard EWHs. While the average value of the EF for a standard EWH is close to 1.0, the HPWH systems yield EFs averaging more than 2.00, resulting in annual energy savings averaging more than 50%. The results also showed that, HPWH systems are effective at reducing utility peak demand-loads, in addition to providing substantial cost savings to consumers.


2016 ◽  
Vol 47 (3) ◽  
pp. 164-170 ◽  
Author(s):  
Alexandros Sotirios Anifantis ◽  
Simone Pascuzzi ◽  
Giacomo Scarascia-Mugnozza

Greenhouses play a significant function in the modern agriculture economy even if require great amount of energy for heating systems. An interesting solution to alleviate the energy costs and environmental problems may be represented by the use of geothermal energy. The aim of this paper, based on measured experimental data, such as the inside greenhouse temperature and the heat pump performance (input and output temperatures of the working fluid, electric consumption), was the evaluation of the suitability of low enthalpy geothermal heat sources for agricultural needs such as greenhouses heating. The study was carried out at the experimental farm of the University of Bari, where a greenhouse was arranged with a heating system connected to a ground-source heat pump (GSHP), which had to cover the thermal energy request. The experimental results of this survey highlight the capability of the geothermal heat source to ensue thermal conditions suitable for cultivation in greenhouses even if the compressor inside the heat pump have operated continuously in a fluctuating state without ever reaching the steady condition. Probably, to increase the performance of the heat pump and then its coefficient of performance within GSHP systems for heating greenhouses, it is important to analyse and maximise the power conductivity of the greenhouse heating system, before to design an expensive borehole ground exchanger. Nevertheless, according to the experimental data obtained, the GSHP systems are effective, efficient and environmental friendly and may be useful to supply the heating energy demand of greenhouses.


2017 ◽  
Vol 8 (3) ◽  
pp. 404-411 ◽  
Author(s):  
Yuguo Wu ◽  
Yake Jiang ◽  
Bo Gao ◽  
Zhigang Liu ◽  
Jing Liu

Abstract Water reuse and desalination systems are energy intensive processes, and their increasing use is leading energy consumption within water systems to be an increasingly important issue. Shower wastewater contains large amounts of heat, so there is an opportunity to recover energy from shower water to offset energy consumption elsewhere in water systems. This paper found ways to increase the output of hot water and lower the energy consumption by establishing a thermodynamic model of an instantaneous wastewater source heat pump. The system proved to be very effective, the heating COP (coefficient of performance) can reach 3.3 even in the winter. Under the conditions of limited heat transfer area, reducing the suction pressure of a compressor is a more feasible way to increase the hot water output to meet the needs of users rather than increasing the discharge pressure. Besides, increasing the heat transfer area of the evaporator is a more effective option. When the heat transfer area of evaporator varies from 0.5 to 1.0 square meters, a notable change is that the heating COP increases from 3.283 to 3.936. The heating COP in a system with a recuperator can reach 5.672, almost double that compared to the original systems.


2013 ◽  
Vol 411-414 ◽  
pp. 3084-3087
Author(s):  
Shu Zhang ◽  
Mao Yu Zheng

In this paper, the mathematical models of a GCHP system and a Ground-couple heat pump system with air-soil thermal storage (GCHPASTS) were developed, and the 20-year performances of the two systems were simulated in severe cold area of china, respectively. The results show that the soil temperature declines gradually during the operation of a GCHP system, which leads to the decrease of the coefficient of performance (COP) and the heating effect of the heat pump year after year. On the contrary, the balance of ground thermal load can be realized during the operation of a GCHPASTS system, and the heating performance of heat pump is stable and efficient for long time. So, it can be proved that a GCHP system cant be used for heating alone, while a GCHPASTS system is feasibility.


2013 ◽  
Vol 805-806 ◽  
pp. 486-491
Author(s):  
Yue Ren Wang ◽  
Yu Feng Jiang ◽  
Min Yu

Using Dest software simulation benchmark building the dynamic heat load, analyzing its distribution pattern, at the same timewe can also get heat pump units in the COP value is different under different working condition, then the soil source heat pump and central heating complementary heating system, undertake in soil source heat pump system design heat load, under theconditions of different proportion of the whole system operation energy consumption, initial investment analysis, we conclude thatthe soil source heat pump and central heating complementary heating systems of different energy matching optimization features,this provides a reference for practical engineering.


2016 ◽  
Vol 19 ◽  
pp. 20-26 ◽  
Author(s):  
Moritz Hein ◽  
Ralf Stöber ◽  
Gerhard Fischerauer ◽  
Johannes Bürner ◽  
Jörg Franke ◽  
...  

The central heating units of buildings are typically replaced every 20 to 30 years. There exists a variety of solutions for fuel-and gas-based units, but it would be advantageous to be able to use renewable energies. This would become possible by the combination of planar carbon-fiber-based infrared (IR) radiant heating foils with a heat pump providing hot water. The main goal of our proposed overall control strategy is to increase the energy efficiency while maintaining the thermal comfort for the residents. We examined the electromagnetic compatibility of the heating foils and simulated the relative contributions of the amount of energy provided by the heat pump and by the heating foils to obtain a maximum coefficient of performance for the combined heating system.