scholarly journals The Use of Generalized Gaussian Distribution in Vibroacoustic Detection of Power Transformer Core Damage

Energies ◽  
2020 ◽  
Vol 13 (10) ◽  
pp. 2525
Author(s):  
Robert Krupiński ◽  
Eugeniusz Kornatowski

Vibroacoustic diagnostics (VM—Vibroacoustic Method) is one of the methods for diagnosing the active part of power transformers. Measurement technologies have been refined over the past several years, but the methods of analyzing data obtained in VM diagnostics are still in development. In most cases, they are based on a simple frequency spectrum analysis, and the diagnostic conclusions are subjective and depend on the expert’s professional experience. The article presents an objective method for the detection of transformer unit core damage, based on the analysis of the statistical properties of the vibration signal registered on the surface of the tank of an unloaded transformer in the steady state of vibrations (VM). The algorithm for proceeding further is: FFT analysis of the vibroacoustic signal, with the determination of the relative changes in vibration power as a function of frequency P r ( f ) and, finally, the determination of the statistic properties of the dataset P r ( f ) . The Generalized Gaussian Distribution (GGD) is used to describe the P r ( f ) set. The detector output values are the λ and p parameters of the GGD distribution. These two numerical values form the basis for the classification of the technical condition of the transformer unit core. The correctness of the described solution was verified on the example of ten pieces of 16 MVA power transformers with different operating times and degrees of wear.

2021 ◽  
Author(s):  
◽  
Gints Poišs

A power transformer is a key unit in the transmission system, and its cut-off can impact both consumers and the general stability of the system. Therefore, it is an important tool for processing the operational and technical condition data to quantify them as the technical condition index (TCI). Based on the technical condition of the power transformer, the TCI enables objective and reasoned decisions on the future investments related to replacement or repairs of transformers. Thus, by using the TCI, the service life of the transformer can be safely extended, since the identified risks have been recognized and are being followed-up. The TCI method is useful for a power transformer park, because it allows easy identification of transformers that require most attention. A crucial precondition for this method is data availability, diversity, and regularity or frequency of data collection. These features (preconditions) may vary in different power transmission systems, and it creates the necessity for a tailored approach. The present Doctoral Thesis studies the diagnostic methods used in the transmission system in Latvia and the results thereof. Thus, it takes advantage of an already existing data set and flow to develop a TCI-based complex of algorithms for determining the risk level of high-power transformers in acceptable risk conditions.


2018 ◽  
Vol 58 ◽  
pp. 02007
Author(s):  
Svetlana Vysogorets ◽  
Alexandr Nazarychev ◽  
Ilia Gorec ◽  
Alexey Tadjibaev

The relationship between the resource of a power transformer and the resource characteristics of a liquid dielectric is shown. Determined the key quality indicators, which allow to control the resource of the liquid dielectric. For the first time, “The method of experimental determination of the liquid dielectric resource and measures for its restoration” was developed.


2017 ◽  
Vol 26 (102) ◽  
pp. 110-119
Author(s):  
D. S. Yarymbash, ◽  
◽  
S. T. Yarymbash, ◽  
T. E. Divchuk, ◽  
D. A. Litvinov

Vestnik MEI ◽  
2020 ◽  
Vol 6 (6) ◽  
pp. 82-90
Author(s):  
Dmitriy I. Panfilov ◽  
◽  
Mikhail G. Astashev ◽  
Aleksandr V. Gorchakov ◽  
◽  
...  

The specific features relating to voltage control of power transformers at distribution network transformer substations are considered. An approach to implementing high-speed on-load voltage control of serially produced 10/0.4 kV power transformers by using a solid-state on-load tap changer (SOLTC) is presented. An example of the SOLTC circuit solution on the basis of thyristor switches is given. On-load voltage control algorithms for power transformers equipped with SOLTC that ensure high reliability and high-speed operation are proposed. The SOLTC performance and the operability of the suggested voltage control algorithms were studied by simulation in the Matlab/Simulink environment and by experiments on the SOLTC physical model. The structure and peculiarities of the used simulation Matlab model are described. The SOLTC physical model design and its parameters are presented. The results obtained from the simulating the SOLTC operation on the Matlab model and from the experiments on the SOLTS physical model jointly with a power transformer under different loads and with using different control algorithms are given. An analysis of the experimental study results has shown the soundness of the adopted technical solutions. It has been demonstrated that the use of an SOLTC ensures high-speed voltage control, high efficiency and reliability of its operation, and arcless switching of the power transformer regulating taps without load voltage and current interruption. By using the SOLTC operation algorithms it is possible to perform individual phase voltage regulation in a three-phase 0.4 kV distribution network. The possibility of integrating SOLTC control and diagnostic facilities into the structure of modern digital substations based on the digital interface according to the IEC 61850 standard is noted.


2017 ◽  
Vol 1 (20) ◽  
pp. 63-74 ◽  
Author(s):  
Arkadiusz Rychlik ◽  
Krzysztof Ligier

This paper discusses the method used to identify the process involving fatigue cracking of samples on the basis of selected vibration signal characteristics. Acceleration of vibrations has been chosen as a diagnostic signal in the analysis of sample cross section. Signal characteristics in form of change in vibration amplitudes and corresponding changes in FFT spectrum have been indicated for the acceleration. The tests were performed on a designed setup, where destruction process was caused by the force of inertia of the sample. Based on the conducted tests, it was found that the demonstrated sample structure change identification method may be applied to identify the technical condition of the structure in the aspect of loss of its continuity and its properties (e.g.: mechanical and fatigue cracks). The vibration analysis results have been verified by penetration and visual methods, using a scanning electron microscope.


2020 ◽  
Vol 67 (1) ◽  
pp. 42-47
Author(s):  
Anatoliy I. Sopov ◽  
Aleksandr V. Vinogradov

In power transformers, energy losses in the form of heat are about 2 percent of their rated power, and in transformers of large power centers reach hundreds of kilowatts. Heat is dissipated into the environment and heats the street air. Therefore, there is a need to consume this thermal energy as a source of heat supply to nearby facilities. (Research purpose) To develop methods and means of using excess heat of power transformers with improvement of their cooling system design. (Materials and methods) The authors applied following methods: analysis, synthesis, comparison, monographic, mathematical and others. They analyzed various methods for consuming excess heat from power transformers. They identified suitable heat supply sources among power transformers and potential heat consumers. The authors studied the reasons for the formation of excess heat in power transformers and found ways to conserve this heat to increase the efficiency of its selection. (Results and discussion) The authors developed an improved power transformer cooling system design to combine the functions of voltage transformation and electric heating. They conducted experiments to verify the effectiveness of decisions made. A feasibility study was carried out on the implementation of the developed system using the example of the TMG-1000/10/0.4 power transformer. (Conclusions) The authors got a new way to use the excess heat of power transformers to heat the AIC facilities. It was determined that the improved design of the power transformer and its cooling system using the developed solutions made it possible to maximize the amount of heat taken off without quality loss of voltage transformation.


2018 ◽  
Vol 239 ◽  
pp. 06002
Author(s):  
P.V. Chepur ◽  
A.A. Tarasenko ◽  
A.A. Gruchenkova

The problem of the limiting states occurrence in the structures of a vertical steel tank is investigated in this work. To study the SSS of the metal structures of the object, the authors created a numerical model of the RVS-20000 tank in the ANSYS software complex. The model considers the maximum number of elements with their geometry and connections affecting the tank SSS under non-axisymmetric loading, including beyond the elasticity of steel. Dependences between the parameters of intrinsic stiffness of the VST are obtained. The results of the finite element analysis made it possible to develop a technique for assessing the technical condition of the structure with the development of irregular subsidence of the external bottom contour. The proposed technique can be used by both operating and design organizations in making managerial decisions regarding the repair of RVS-20000 subjected to the base subsidence.