scholarly journals Thermodynamic Analysis of a Hybrid System Coupled Cooling, Heating and Liquid Dehumidification Powered by Geothermal Energy

Energies ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 6084
Author(s):  
Aixiang Xu ◽  
Mengjin Xu ◽  
Nan Xie ◽  
Yawen Xiong ◽  
Junze Huang ◽  
...  

The utilization of geothermal energy is favorable for the improvement of energy efficiency. A hybrid system consisting of a seasonal heating and cooling cycle, an absorption refrigeration cycle and a liquid dehumidification cycle is proposed to meet dehumidification, space cooling and space heating demands. Geothermal energy is utilized effectively in a cascade approach. Six performance indicators, including humidity efficiency, enthalpy efficiency, moisture removal rate, coefficient of performance, cooling capacity, and heating capacity, are developed to analyze the proposed system. The effect of key design parameters in terms of desiccant concentration, air humidity, air temperature, refrigeration temperature and segment temperature on the performance indicators are investigated. The simulation results indicated that the increase of the desiccant concentration makes the enthalpy efficiency, the coefficient of performance, the moisture removal rate and the cooling capacity increase and makes the humidity efficiency decrease. With the increase of air humidity, the humidity efficiency and moisture removal rate for the segment temperatures from 100 to 130 °C are approximately invariant. The decreasing rates of the humidity efficiency and the moisture removal rate with the segment temperature of 140 °C increases respectively. Six indicators, except the cooling capacity and heating capacity, decrease with an increase of air temperature. The heating capacity decreases by 49.88% with the reinjection temperature increasing from 70 to 80 °C. This work proposed a potential system to utilize geothermal for the dehumidification, space cooling and space heating effectively.

2012 ◽  
Vol 433-440 ◽  
pp. 1219-1225
Author(s):  
Jing Hong Ning ◽  
Sheng Chun Liu

This paper reports a combined space cooling, space heating, water heating and food refrigeration system (named CO2 combined system) in supermarket. This system using CO2 as the working fluid consists of a two-stage CO2 transcritical cycle used for food refrigeration, a single-stage CO2 transcritical cycle for space cooling in summer and space heating in winter. The waste heat emitted from the CO2 gas cooling in food refrigeration cycle and space cooling and space heating cycles is recovered by heat recover exchanger and is used to provide hot water for space heating and for general usage, such as the catering, the washing and the toilet facilities in the supermarket. So this CO2 combined system improves the coefficient of performance, decreases the energy consumption as well as reduces the heat pollution. Moreover, this CO2 combined system is compared with typical conventional supermarket technology, the results show that the energy consumption of CO2 combined system is reduced largely and energy efficiency is increased obviously. It can be concluded that the CO2 combined system has a good future for protecting environment and saving energy.


1991 ◽  
Vol 113 (2) ◽  
pp. 80-88 ◽  
Author(s):  
S. Farooq ◽  
D. M. Ruthven

The cyclic operation of a desiccant bed used for solar air conditioning applications has been simulated numerically. The results suggest that the optimal choice of desiccant is not seriously limited by the shape of the isotherm since the effect of isotherm shape on the moisture removal rate can be adequately compensated by appropriate adjustment of the cycle time. The conditions required to maximize the moisture removal rate for any given degree of nonlinearity also satisfy the requirements for maximizing the thermal coefficient of performance.


2021 ◽  
pp. 1-32
Author(s):  
Bismark Addo-Binney ◽  
Wahid Besada ◽  
Martin Agelin-Chaab

Abstract This paper performed analyses on a proposed direct wind-powered heat pump integrated with a pond which serves as an evaporator for space heating in cold regions. The analysis was conducted using environmental data for selected locations in Canada and the Engineering Equation Solver. Three different pairings of heat pumps and wind turbines were studied (a wind-powered heat pump with a pond as an evaporator, a wind-powered heat pump without a pond, and an electricity-powered heat pump). Energy and exergy analyses were performed on the systems. The novelty in the present study is in the use of a wind turbine to directly power the heat pump and using a pond as the evaporator. The results show that the proposed system has the highest coefficient of performance compared to the others. The average coefficient of performance for the selected locations is 2.7, which is at least 67% better than the others. Similarly, the overall exergy for the proposed system is 16.9%, which is at least 40% better than the others. The average heating capacity of the selected locations for the proposed system is 4.5 kW, which is from 29% to 300% better than the others. Additionally, the sustainability index for the proposed system is the highest for the proposed system. The results have shown that the proposed system has superior overall performance for space heating in cold regions.


2013 ◽  
Vol 17 (5) ◽  
pp. 1261-1268 ◽  
Author(s):  
Xiao-Wei Fan ◽  
Xian-Ping Zhang ◽  
Fu-Jun Ju ◽  
Fang Wang

Nowadays, HCFC22 is widely used in heat pump systems in China, which should be phased out in the future. Thus, eco-friendly mixture CO2/dimethylether is proposed to replace HCFC22. Compared with pure CO2 and pure dimethylether, the mixture can reduce the heat rejection pressure, and suppress the flammability and explosivity of pure dimethylether. According to the Chinese National Standards on heat pump water heater and space heating system, performances of the subcritical heat pump system are discussed and compared with those of the HCFC22 system. It can be concluded that CO2 /dimethylether mixture works efficiently as a refrigerant for heat pumps with a large heat-sink temperature rise. When mass fraction of dimethylether is increased, the heat rejection pressure is reduced. Under the nominal working condition, there is an optimal mixture mass fraction of 28/72 of CO2/dimethylether for water heater application under conventional condensation pressure, 3/97 for space heating application. For water heater application, both the heating coefficient of performance and volumetric heating capacity increase by 17.90% and 2.74%, respectively, compared with those of HCFC22 systems. For space heating application, the heating coefficient of performance increases by 8.44% while volumetric heating capacity decreases by 34.76%, compared with those of HCFC22 systems. As the superheat degree increases, both the heating coefficient of performance and volumetric heating capacity tend to decrease.


2001 ◽  
Vol 124 (1) ◽  
pp. 63-69 ◽  
Author(s):  
Dennis L. O’Neal ◽  
Angel Rodriguez ◽  
Michael Davis ◽  
Sekhar Kondepudi

An experimental study was conducted to quantify the effect of return air leakage from hot/humid attic spaces on the performance of a residential air conditioner. Tests were conducted in psychrometric facilities where temperatures and humidities could be controlled closely. The test air conditioner had a nominal cooling capacity of 12.3 kW and a seasonal coefficient of performance of 3.8. Return air leakage from hot attic spaces was simulated by assuming adiabatic mixing of the indoor air at normal conditions with the attic air at high temperatures. Effective capacity and coefficient of performance both decreased with increased return air leakage, leakage air temperature, and air humidity. Under attic conditions of 54.4°C and 20 percent relative humidity, 10% return leakage reduced the effective cooling capacity and coefficient of performance of the air conditioner by approximately 30%. Power consumption was relatively constant for all variables except outdoor temperature. The sensible heat ratio (SHR), which is a measure of the dehumidification performance, increased with increasing leakage.


Author(s):  
CP Jawahar

This paper presents the energy analysis of a triple effect absorption compression (hybrid) cycle employing ammonia water as working fluid. The performance parameters such as cooling capacity and coefficient of performance of the hybrid cycle is analyzed by varying the temperature of evaporator from −10 °C to 10 °C, absorber and condenser temperatures in first stage from 25 °C to 45 °C, degassing width in both the stages from 0.02 to 0.12 and is compared with the conventional triple effect absorption cycle. The results of the analysis show that the maximum cooling capacity attained in the hybrid cycle is 472.3 kW, at 10 °C evaporator temperature and first stage degassing width of 0.12. The coefficient of performance of the hybrid cycle is about 30 to 65% more than the coefficient of performance of conventional triple effect cycle.


Author(s):  
Ali Al-Alili ◽  
Yunho Hwang ◽  
Reinhard Radermacher

In hot and humid regions, removal of moisture from the air represents a considerable portion of the air conditioning load. Conventionally, air conditioning systems have to lower the air temperature below its dew point to accomplish dehumidification. Desiccant air conditioners offer a solution to meet the humidity and temperature requirements of buildings via decoupling latent and sensible loads. In this work, the performance of a new desiccant material is investigated experimentally. This desiccant material can be regenerated using a low temperature heat source, as low as 45°C. It also has a unique S-shape isotherm. The effects of the process air stream’s temperature and humidity, the regeneration temperature, the ventilation mass flow rate, and the desiccant wheel’s rotational speed on the cycle performance are investigated. ARI-humid conditions are used as a baseline and the moisture mass balance is maintained within 5%. The results are presented in terms of the moisture removal rate and latent coefficient of performance (COPlat). The results show a desiccant wheel’s COPlat higher than unity when it is coupled with an enthalpy wheel.


2021 ◽  
Vol 4 ◽  
pp. 133-139
Author(s):  
Rikhard Ufie ◽  
Cendy S. Tupamahu ◽  
Sefnath J. E. Sarwuna ◽  
Jufraet Frans

Refrigerant R-22 is a substance that destroys the ozone layer, so that in the field of air conditioning it has begun to be replaced, among others with refrigerants R-32 and R-410a, and also R-290. Through this research, we want to know how much Coefficient of Performance (COP) and Refrigeration Capacity (Qe) can be produced for the four types of refrigerants. The study was carried out theoretically for the working conditions of the vapor compression cycle with an evaporation temperature (Tevap) of 0, -5, and -10oC, a further heated refrigerant temperature (ΔTSH) of 5 oC, a condensation temperature (Tkond) of 45 oC and a low-cold refrigerant temperature. (ΔTSC) 10 oC and compression power of 1 PK . The results of the study show that the Coefficient of Performance (COP) in the use of R-22 and R-290 is higher than the use of R-32 and R-410a, which are 4,920 respectively; 4,891; 4.690 and 4.409 when working at an evaporation temperature of 0 oC; 4.260; 4,234; 4.060 and 3.812 when working at an evaporation temperature of -5 oC; and amounted to 3,730; 3,685; 3,550 and 3,324 if working at an evaporation temperature of -10 oC. Based on the size of the COP, if this installation works with a compression power of 1 PK, then the cooling capacity of the R-22 and R-290 is higher than the R-32 and R-410a, which are 3,617 respectively. kW; 3,597 kW; 3,449 kW and 3,243 kW. If working at an evaporation temperature of 0 oC; 3.133 kW; 3.114 kW; 2,986 kW and 2,804 kW if working at an evaporation temperature of -5 oC; and 2,741 kW; 2,710 kW; 2,611 kW and 2,445 kW if working at an evaporation temperature of -10oC.


Author(s):  
Jeremy Spitzenberger ◽  
Pengtao Wang ◽  
Laith Ismael ◽  
Hongbin Ma ◽  
Ahmad Abuheiba ◽  
...  

Abstract Ejector driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this investigation, a single-stage gas-fired ejector heat pump (EHP) is investigated and thermodynamically modeled in order to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) temperatures on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120-180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Results show that an optimized COP of the EHP system exists which depends on HTE and LTE temperatures, primary nozzle throat diameters. In addition, it is found that the EHP COP is independent of the ejector COP. From this investigation a maximum EHP COP of 1.31 is able to be achieved for a HTE temperature of 160 °C and a LTE temperature of 19.5 °C with a total heating capacity of 15.98 kW.