scholarly journals Bedsores Management: Efficiency Simulation of a New Mattress Design

Healthcare ◽  
2021 ◽  
Vol 9 (12) ◽  
pp. 1701
Author(s):  
Abdullatif Alwasel ◽  
Bandar Alossimi ◽  
Maha Alsadun ◽  
Khalid Alhussaini

Bedsores, also known as pressure ulcers, are wounds caused by the applied external force (pressure) on body segments, thereby preventing blood supply from delivering the required elements to the skin tissue. Missing elements hinder the skin’s ability to maintain its health. It poses a significant threat to patients that have limited mobility. A new patented mattress design and alternative suggested designs aimed to reduce pressure are investigated in this paper for their performance in decreasing pressure. A simulation using Ansys finite element analysis (FEA) is carried out for comparison. Three-dimensional models are designed and tested in the simulation for a mattress and human anthropometric segments (Torso and Hip). All designs are carried out in solidworks. Results show that the original design can redistribute the pressure and decrease it up to 17% less than the normal mattress. The original design shows better ability to decrease the absolute amount of pressure on the body. However, increasing the surface area of the movable parts results in less pressure applied to the body parts. Thus, this work suggests changing the surface area of the cubes from 25 to 100 cm2.

Author(s):  
A. A. Popova ◽  
◽  
I. N. Shubin ◽  
R. E. Aliev ◽  
◽  
...  

Three-dimensional models of the body parts were developed using the basic 3D modeling operations (rotation, extrusion, threading, etc.) of the T-FLEX CAD 3D CAD system, which made it possible to significantly simplify the work with assembly 3D models representing a complex structure consisting of a large number of parts. During the trial operation, the advantages of using the T-FLEX CAD 3D CAD system have been proven when working with complex 3D models. The advantages of using the program in the machine-building cluster are shown.


2012 ◽  
Vol 490-495 ◽  
pp. 1451-1455
Author(s):  
Guang Yao Zhao ◽  
Yi Feng Zhao ◽  
Chuan Yin Tang ◽  
Zhi Yuan Du

Aimed at SUV-type vehicle, simulation and analysis of pressure resistance experiments on the body of automobile has been presented in the paper, according to the vehicle safety regulations and standards of FMVSS216. A limited SUV vehicle model is created; simulation is obtained with the help of software LS-DYNA, based on the principle of finite element analysis method. Assessment of pressure resistance and safety of the automobile has been presented, from the aspect of the deformation of body, the energy absorption of the vehicle and components, and the pressure on the body, etc. By rational improving of the original design of body structure, the reasonable distribution of pressure absorbability of the body of the SUV-type automobile is achieved. The effect of the overall energy absorption of the body is fully exerted, and then the safety of the driver and the passenger in a rollover accident is improved. Research methods and conclusions of this paper provide useful ways and references to the research of the safety of vehicle rollover and design of rationality of body energy absorption


2019 ◽  
Vol 44 (5) ◽  
pp. 462-467 ◽  
Author(s):  
Teun Teunis ◽  
Sjoerd Meijer ◽  
Jesse Jupiter ◽  
Daniel Rikli ◽  

This study aimed to determine the association of teardrop angle and anteroposterior distance with anterior lunate facet displacement and articular congruity before and after anterior plating of distal radial fractures. We included 36 patients with complete intra-articular distal radial fractures with separate anterior lunate facet fragments. On radiographs we determined the teardrop angle and anteroposterior distance. On digital three-dimensional models we measured proximal-distal, anteroposterior and ulnoradial anterior lunate facet displacement, and we outlined the gap surface area. Preoperatively, teardrop angle was highly associated with the extent of anterior lunate facet displacement. Increased anteroposterior distance was mainly associated with articular incongruity after anterior plate fixation. This information may reduce the need of preoperative computed tomography scans in fractures with a normal tear drop angle. This is particularly useful in low-resource settings.


2019 ◽  
Vol 53 (3) ◽  
pp. 197-205
Author(s):  
Kshitij Hemant Sabley ◽  
Usha Shenoy ◽  
Sujoy Banerjee ◽  
Pankaj Akhare ◽  
Ananya Hazarey ◽  
...  

Objective: To assess and compare the tensions and deformations (stresses and strains) generated after application of two types of forces (traction and torsion) in miniscrews of two different materials (titanium and stainless steel) placed at five different angulations. Materials and Methods: Three-dimensional models of the posterior maxillary area and the mini-implants were constructed using computer-aided design software program (CATIA P3 V5-6 R2015 B26 / 2016; Dassault Systèmes). Titanium and stainless steel materials were used for miniscrews. The area constructed was in between the maxillary second premolar and first molar. The models with mini-implants were inserted at five different angulations (30°, 45°, 60°, 75° and 90°). Torsional and tractional forces were applied on these implants, and the models were solved using ANSYS 10.0. Stress generated in implant and in the cortical and cancellous bones was evaluated and compared at all the five angulations. Results: Stress generated in stainless steel mini-implant during torsional and linear force application was less when compared with titanium mini-implant. Also, stress generated in implants of both materials increased as the angle increased from 30° to 90°. Difference in stress generated by stainless steel implant in the cortical bone for both linear and torsional forces was less when compared with titanium implant, whereas for cancellous bone, the difference was insignificant at all the angles. Conclusion: Irrespective of angles, difference in stress generated in stainless steel implants and titanium implants for both the forces was not significant, and hence, stainless steel implants can be used effectively in a clinical setting.


2010 ◽  
Vol 133 (1) ◽  
Author(s):  
Alfonso Campos-Amezcua ◽  
Zdzislaw Mazur-Czerwiec ◽  
Armando Gallegos-Muñoz

This paper presents a thermomechanical analysis of a first stage bucket during a gas turbine startup. This analysis uses two simulation techniques, computational fluid dynamics (CFD) for the conjugate heat transfer and flow analysis, and finite element analysis (FEA) for the thermostructural analysis. Computational three-dimensional models were developed using two commercial codes, including all elements of the real bucket to avoid geometric simplifications. An interface was developed to transfer the three-dimensional behavior of bucket temperatures during turbine startup from CFD analysis to subsequent FEA analysis, imposing them as a thermal load. This interface virtually integrates the computational models, although they have different grids. The results of this analysis include temperature evolution and related stresses, as well as the thermomechanical stresses and zones where they are present. These stresses are dominated by thermal mechanisms, so a new temperature startup curve is proposed where the maximum calculated stress decline around 100 MPa, and almost all stresses are lower throughout the transient analysis. The results are compared with experimental data reported in the literature obtaining acceptable approximation.


Author(s):  
S. H. Su ◽  
J. H. Zhang ◽  
D. H. Tao

A new structure of artificial joints with bionic joint capsule was proposed and designed to overcome the feedback of current prostheses that omitted many functions of lubricant and joint capsule. The new structure was composed of three components: therapeutic lubricant, artificial joints and artificial joint capsule. The lubricant sealed by capsule not only can reduce the wear of artificial joints but also can prohibit the wear particles leaking to the body liquid. So the unwilling reactions between the wear particles and liquid may be avoided completely. Meanwhile, a three-dimensional (3-D) finite element analysis (FEA) model was created for the bionic artificial joints with joint capsule. The effects of capsule thickness and the flexion angels on the stress values and distributions were discussed in detail.


2020 ◽  
Vol 143 ◽  
pp. 01001
Author(s):  
Chengfa Deng ◽  
Chang Xu ◽  
Qi Xie ◽  
Qiang Peng

The safety evaluation of the aqueduct in many years of operation is often performed to determine the structural operational behaviour so as to provide a scientific basis for further reinforcement or reconstruction. The missing of the original design data due to the long construction period provides great challenging in the structural safety evaluation of the aqueduct. Taking a hyperbolic arch aqueduct in China as an example, we first rebuilt the aqueduct model using the three-dimensional (3D) point cloud from the three-dimensional laser scanning technology. Coupled with the on-site safety inspection, the 3D finite element analysis was then performed to learn the stress performance of the aqueduct body and its supporting structures, so as to achieve the purpose of safety evaluation of aqueduct structure in a whole.


2016 ◽  
Vol 87 (1) ◽  
pp. 104-110 ◽  
Author(s):  
Paiboon Techalertpaisarn ◽  
Antheunis Versluis

ABSTRACT Objective: To investigate the effect of the position of the apical portion of closing loops on the force system at both loop ends. Materials and Methods: T-loops were compared with backward-sloped L-loops (SL) and reversed L-loops (RL). SL-loops were directed toward the anterior side; RL-loops were directed toward the posterior side. Loop response to loop pulling was determined with finite element analysis at six positions of the apical loop portion for 12-mm interbracket distance and 8-mm loop length and height. Three-dimensional models of the closing loops were created using beam elements with the properties of stainless steel. Loop responses (horizontal load/deflection, vertical force, and moment-to-force ratio) at both loop ends were calculated as well as at 100 g and 200 g activation forces. Results: T-, SL-, and RL-loops with the same position of the apical portion showed approximately the same force system at both loop ends. This behavior was found across the investigated range through which the loops were moved (interbracket center to posterior bracket). Conclusions: The center of the apical portion determined the force system of the closing loops regardless of the position of the loop legs. The centers of the apical portion of the T-, SL-, and RL-loops acted like V-bend positions.


Sign in / Sign up

Export Citation Format

Share Document