scholarly journals A Historical Perspective of Cardiac Implantable Electronic Device Infection: How a Menace Can Drive Technological and Clinical Improvement

Hearts ◽  
2021 ◽  
Vol 2 (2) ◽  
pp. 202-212
Author(s):  
Giulia Massaro ◽  
Igor Diemberger ◽  
Matteo Ziacchi ◽  
Andrea Angeletti ◽  
Giovanni Statuto ◽  
...  

In recent decades there has been a relevant increase in the implantation rate of cardiac implantable electronic devices (CIEDs), albeit with relevant geographical inhomogeneities. Despite the positive impact on clinical outcomes, the possibility of major complications is not negligible, particularly with respect to CIED infections. CIED infections significantly affect morbidity and mortality, especially in instances of delayed diagnosis and appropriate treatment. In the present review, we will start to depict the factors underlying the development of CIED infection as well as the difficulties related to its diagnosis and treatment. We will explain the reasons underlying the need to focus on prophylaxis rather than treatment, in view of the poor outcomes despite improvements in lead extraction procedures. This will lead to the consideration of management of this complication in a hub-spoke manner, and to our analysis of the several technological and procedural improvements developed to minimize this complication. These include prolongation of CIED longevity, the development of leadless devices, and integrated prophylactic approaches. We will conclude with a discussion regarding new devices and strategies under development. This complete excursus will provide the reader with a new perspective on how a major complication can drive technological improvements.

2016 ◽  
Vol 5 (1) ◽  
pp. 65 ◽  
Author(s):  
Khaldoun G Tarakji ◽  
◽  
Christopher R Ellis ◽  
Pascal Defaye ◽  
Charles Kennergren ◽  
...  

The incidence of infection following implantation of cardiac implantable electronic devices (CIEDs) is increasing at a faster rate than that of device implantation. Patients with a CIED infection usually require hospitalisation and complete device and lead removal. A significant proportion die from their infection. Transvenous lead extraction (TLE) is associated with rare but serious complications including major vascular injury or cardiac perforation. Operator experience and advances in lead extraction methods, including laser technology and rotational sheaths, have resulted in procedures having a low risk of complication and mortality. Strategies for preventing CIED infections include intravenous antibiotics and aseptic surgical techniques. An additional method to reduce CIED infection may be the use of antibacterial TYRX™ envelope. Data from non-randomised cohort studies have indicated that antibacterial envelope use can reduce the incidence of CIED infection by more than 80 % in high-risk patients and a randomised clinical trial is ongoing.


Author(s):  
Khaldoun G Tarakji ◽  
Christopher R Ellis ◽  
Pascal Defaye ◽  
Charles Kennergren ◽  
◽  
...  

The incidence of infection following implantation of cardiac implantable electronic devices (CIEDs) is increasing at a faster rate than that of device implantation. Patients with a CIED infection usually require hospitalisation and complete device and lead removal. A significant proportion die from their infection. Transvenous lead extraction (TLE) is associated with rare but serious complications including major vascular injury or cardiac perforation. Operator experience and advances in lead extraction methods, including laser technology and rotational sheaths, have resulted in procedures having a low risk of complication and mortality. Strategies for preventing CIED infections include intravenous antibiotics and aseptic surgical techniques. An additional method to reduce CIED infection may be the use of antibacterial TYRX™ envelope. Data from non-randomised cohort studies have indicated that antibacterial envelope use can reduce the incidence of CIED infection by more than 80 % in high-risk patients and a randomised clinical trial is ongoing.


Medicina ◽  
2019 ◽  
Vol 55 (9) ◽  
pp. 566
Author(s):  
Nesterovics ◽  
Nesterovics ◽  
Stradins ◽  
Kalejs ◽  
Ansabergs ◽  
...  

Background and Objectives: Over the last five decades cardiac implantable electronic devices (CIED) have become established as the mainstay for the treatment of permanent bradycardias, chronic heart failure and dangerous heart rhythm disturbances. These devices improve survival and quality of life in many patients. However, infections associated with CIED implantation, particularly lead-related infective endocarditis (LRIE), can offset all benefits and make more harm than good for the patient. To date, there are no other studies in Latvia, addressing patients with lead-related infective endocarditis. The objective of this study was to identify the most common pathogens associated with LRIE and their antimicrobial resistance and to identify possible risk factors of patients who present with LRIE. Materials and Methods: The study was performed retrospectively at Pauls Stradins Clinical University Hospital (PSCUH). The study included patients who were referred to PSCUH due to LRIE for lead extraction. Patients were identified from procedural journals. Information about isolated microorganisms, patient comorbidities and visual diagnostics data was taken from patient records. Results: Forty-nine patients with CIED related infective endocarditis were included in the study, 34 (69.4%) were male, median age of all patients was 65.0 (50.5–73.0) years, median hospital stay was 15.5 (22.0–30.5) days. Successful and complete lead extraction was achieved in all patients. Thirty-two (65.3%) had received antibiotics prior to blood sample. Only in 31 (63.3%) positive culture results were seen. The most common isolated pathogens were Staphylococcus aureus (23.5%) and coagulase negative staphylococci (23.5%). Other bacteria were isolated considerably less often. The atrial lead was most common location for lead vegetations, seen in 50.0% of cases. Five (10.2%) patients have died due to the disease. Conclusions: Lead-related infective endocarditis is a major complication of cardiac implantable electronic devices with considerable morbidity and mortality, which in our study was as high as 10.2%.


2020 ◽  
Vol 13 (Suppl_1) ◽  
Author(s):  
Muhammad U Khan ◽  
Ahmad Naeem Lone ◽  
Muhammad Khan ◽  
shahul valavoor ◽  
Muhammad Munir ◽  
...  

Introduction: Cardiac Implantable Electronic Device (CIED) infections are a major source of morbidity, mortality and increased healthcare cost. There are several well established risk factors associated with increased infection. An antibiotic coated envelope has been developed as an infection prevention intervention. Hypothesis: Whether antibiotic coated envelope is an effective preventive strategy against Cardiac Implantable Electronic Device Infections. Methods: 6 trials comparing use of antibiotic envelope to control, including 1 randomized trial and 5 cohort studies were selected using PubMed and Embase data bases through May 2019. The efficacy end point was prevention of CIED Infection. Outcomes were combined using random effects model and estimated by odds ratio with 95% confidence intervals (CI). Results: In our analysis of total 12,024 patients undergoing CIED implantation, 5,844 patients received antibiotic envelope while 6,180 patients were included in the control group. Antibiotic envelope was superior to control in reducing the risk of device infection (OR 0.40 CI [0.17-0.95], p=0.04). Conclusions: The use of antibiotic envelope in Cardiac Implantable Electronic Devices (CIED) is associated with reduced incidence of CIED infection.


EP Europace ◽  
2019 ◽  
Vol 21 (9) ◽  
pp. 1378-1384 ◽  
Author(s):  
Frank Bracke ◽  
Niels Verberkmoes ◽  
Marcel van 't Veer ◽  
Berry van Gelder

Abstract Aims Abandoned leads are often linked to complications during lead extraction, prompting pre-emptive extraction if leads become non-functional. We examined their influence on complications when extracted for device-related infection. Methods and results All patients undergoing lead extraction for device-related infection from 2006 to 2017 in our hospital were included. The primary endpoint was major complications. Out of 500 patients, 141 had abandoned leads, of whom 75% had only one abandoned lead. Median cumulative implant times were 24.2 (interquartile range 15.6–38.2) and 11.6 (5.6–17.4), respectively years with or without abandoned leads. All leads were extracted only with a femoral approach in 50.4% of patients. Mechanical rotational tools were introduced in 2014 and used in 22.2% of cases and replacing laser sheaths that were used in 5% of patients. Major complications occurred in 0.7% of patients with abandoned leads compared with 1.7% of patients with only active leads (P = 0.679). Failure to completely remove all leads was 14.9% and 6.4%, respectively with or without abandoned leads (P = 0.003), and clinical failure was 6.4% and 2.2% (P = 0.028), respectively. Procedural failure dropped to 9.2% and 5.7% (P = 0.37), respectively after the introduction of mechanical rotational tools. The only independent predictor of procedural and clinical failure in multivariate analysis was the cumulative implant duration. Conclusion Despite longer implant times, patients with abandoned leads did not have more major complications during lead extraction. Therefore, preventive extraction of non-functional leads to avoid complications at a later stage is not warranted.


Author(s):  
Łukasz Tułecki ◽  
Anna Polewczyk ◽  
Wojciech Jacheć ◽  
Dorota Nowosielecka ◽  
Konrad Tomków ◽  
...  

Background: Transvenous lead extraction (TLE) is the preferred management strategy for complications related to cardiac implantable electronic devices. TLE sometimes can cause serious complications. Methods: Outcomes of TLE procedures using non-powered mechanical sheaths were analyzed in 1500 patients (mean age 68.11 years; 39.86% females) admitted to two high-volume centers. Results: Complete procedural success was achieved in 96.13% of patients; clinical success in 98.93%, no periprocedural death occurred. Mean lead dwell time in the study population was 112.1 months. Minor complications developed in 115 (7.65%), major complications in 33 (2.20%) patients. The most frequent minor complications were tricuspid valve damage (TVD) (3.20%) and pericardial effusion that did not necessitate immediate intervention (1.33%). The most common major complication was cardiac laceration/vascular tear (1.40%) followed by an increase in TVD by two or three grades to grade 4 (0.80%). Conclusions: Despite the long implant duration (112.1 months) satisfying results without procedure-related death can be obtained using mechanical tools. Lead remnants or severe tricuspid regurgitation was the principal cause of lack of clinical and procedural success. Worsening TR(Tricuspid regurgitation) (due to its long-term consequences), but not cardiac/vascular wall damage; is still the biggest TLE-related problem; when non-powered mechanical sheaths are used as first-line tools.


2014 ◽  
Vol 3 (3) ◽  
pp. 184 ◽  
Author(s):  
Cristian Podoleanu ◽  
Jean-Claude Deharo ◽  
◽  

Despite improved preventive measures, infection associated with the use of cardiac implantable electronic devices (CIEDs) to treat often life-threatening conditions is rising at an average annual rate of almost 5 %. This rise is being driven by the increasing complexity of CIED technology and by the advancing age and co-morbidities of the patients. Although CIED infection is usually suspected based on local signs at the generator pocket site, diagnosis can be challenging in patients presenting no local manifestations or symptoms. Diagnostic methods include microbiological testing and echocardiography, and may be completed by positron emission tomography (PET)/computed tomography (CT) scan in selected cases. CIED infection requires a multidisciplinary approach in view of hardware extraction, targeted antibiotic therapy and reimplantation on an as-needed basis. Antibiotic prophylaxis targeting staphylococcal flora is recommended but the relation of these infections to medical care exposes patients to multi-resistant bacteria. New preventive measures utilising an antibacterial sleeve look promising. Treatment can be started on an empirical basis using an antistaphylococcal agent but must be continued using targeted antibiotic therapy. Crucial questions remain as to the best prevention strategy, optimal duration and timing of antibiotic therapy, and the most effective reimplantation technique.


Sign in / Sign up

Export Citation Format

Share Document