scholarly journals Previous Intensive Running or Swimming Negatively Affects CPR Effectiveness

Author(s):  
J. Arturo Abraldes ◽  
Ricardo J. Fernandes ◽  
Ricardo Morán-Navarro

Survival outcomes increase significantly when cardiopulmonary resuscitation (CPR) is provided correctly, but rescuers’ fatigue can compromise its delivery. We investigated the effect of two exercise modes on CPR effectiveness and physiological outputs. After 4 min baseline conditions, 30 lifeguards randomly performed a 100 m run and a combined water rescue before 4 min CPR (using an adult manikin and a 30:2 compression–ventilation ratio). Physiological variables were continuously measured during baseline and CPR using a portable gas analyzer (K4b2, Cosmed, Rome, Italy) and CPR effectiveness was analyzed using two HD video cameras. Higher oxygen uptake (23.0 ± 9.9 and 20.6 ± 9.1 vs. 13.5 ± 6.2 mL·kg·min−1) and heart rate (137 ± 19 and 133 ± 15 vs. 114 ± 15 bpm), and lower compression efficacy (63.3 ± 29.5 and 62.2 ± 28.3 vs. 69.2 ± 28.0%), were found for CPRrun and CPRswim compared to CPRbase. In addition, ventilation efficacy was higher in the rescues preceded by intense exercise than in CPRbase (49.5 ± 42.3 and 51.9 ± 41.0 vs. 33.5 ± 38.3%), but no differences were detected between CPRrun and CPRswim. In conclusion, CPRrun and CPRswim protocols induced a relevant physiological stress over each min and in the overall CPR compared with CPRbase. The CPRun protocol reduces the compression rate but has a higher effectiveness percentage than the CPRswim protocol, in which there is a considerably higher compression rate but with less efficacy.

Author(s):  
J. Arturo Abraldes ◽  
Ricardo J. Fernandes ◽  
Núria Rodríguez ◽  
Ana Sousa

Survival outcomes increase significantly when cardiopulmonary resuscitation (CPR) is provided correctly, but rescuer’s fatigue can compromise CPR delivery. We investigated the effect of a 100-m maximal run on CPR and physiological variables in 14 emergency medical technicians (age 29.2 ± 5.8 years, height 171.2 ± 1.1 cm and weight 73.4 ± 13.1 kg). Using an adult manikin and a compression-ventilation ratio of 30:2, participants performed 4-min CPR after 4-min baseline conditions (CPR) and 4-min CPR after a 100-m maximal run carrying emergency material (CPR-run). Physiological variables were continuously measured during baseline and CPR conditions using a portable gas analyzer (K4b2, Cosmed, Rome, Italy) and analyzed using two HD video cameras (Sony, HDR PJ30VE, Japan). Higher VO2 (14.4 ± 2.1 and 22.0 ± 2.5 mL·kg−1·min−1) and heart rate (123 ± 17 and 148 ± 17 bpm) were found for CPR-run. However, the compression rate was also higher during the CPR-run (373 ± 51 vs. 340 ± 49) and between every three complete cycles (81 ± 9 vs. 74 ± 14, 99 ± 14 vs. 90 ± 10, 99 ± 10 vs. 90 ± 10, and, 101 ± 15 vs. 94 ± 11, for cycle 3, 6, 9 and 12, respectively). Fatigue induced by the 100-m maximal run had a strong impact on physiological variables, but a mild impact on CPR emergency medical technicians’ performance.


2021 ◽  
pp. 104687812110326
Author(s):  
Adeel Arif ◽  
Amber Arif ◽  
Kimberly Anne Fasciglione ◽  
Farrukh Nadeem Jafri

Abstract: Background Locations concentrated with High School (HS) students tend to have lower out-of-hospital cardiac arrest (OHCA) survival rates. Mobile applications (apps) have the capability to augment cardiopulmonary resuscitation (CPR) skill retention as a low-cost, accessible training method. Methods An iterative process to develop an app to reinforce CPR skills emphasizing hand placement, compression rate, real-time feedback, and recurring tips is described. The app was tested on HS students to measure its impact on quality and comfort of CPR using Likert surveys and skills assessments before and after one month of usage. CPR Score and compression rate were measured using the Laerdal™ Little Anne Manikin QCPR software. Results Fourteen HS students participated in a prospective observational study. It was found that the use of the developed app was associated with improved CPR performance (80.43% v. 87.86%, p=0.01-0.02, 95% CI=2.20-12.66) after one month. Additionally, improvements were demonstrated in compression rate accuracy (21.43% v. 64.29%, p=0.041, 95% CI=0.132-0.725), increased comfort performing CPR (3.86 v. 4.79, p<0.001, 95% CI =0.99-1.00) and comfort performing CPR on strangers (2.71 v. 4.42, p<0.001, 95% CI=1.24-2.19). In addition, for every time the app was used, CPR performance increased by 0.5668% (p=0.0182). Conclusion Findings suggest that mobile apps may have promising implications as augmentative tools for CPR curriculums.


2021 ◽  
pp. 088506662110189
Author(s):  
Merry Huang ◽  
Aaron Shoskes ◽  
Migdady Ibrahim ◽  
Moein Amin ◽  
Leen Hasan ◽  
...  

Purpose: Targeted temperature management (TTM) is a standard of care in patients after cardiac arrest for neuroprotection. Currently, the effectiveness and efficacy of TTM after extracorporeal cardiopulmonary resuscitation (ECPR) is unknown. We aimed to compare neurological and survival outcomes between TTM vs non-TTM in patients undergoing ECPR for refractory cardiac arrest. Methods: We searched PubMed and 5 other databases for randomized controlled trials and observational studies reporting neurological outcomes or survival in adult patients undergoing ECPR with or without TTM. Good neurological outcome was defined as cerebral performance category <3. Two independent reviewers extracted the data. Random-effects meta-analyses were used to pool data. Results: We included 35 studies (n = 2,643) with the median age of 56 years (interquartile range [IQR]: 52-59). The median time from collapse to ECMO cannulation was 58 minutes (IQR: 49-82) and the median ECMO duration was 3 days (IQR: 2.0-4.1). Of 2,643, 1,329 (50.3%) patients received TTM and 1,314 (49.7%) did not. There was no difference in the frequency of good neurological outcome at any time between TTM (29%, 95% confidence interval [CI]: 23%-36%) vs. without TTM (19%, 95% CI: 9%-31%) in patients with ECPR ( P = 0.09). Similarly, there was no difference in overall survival between patients with TTM (30%, 95% CI: 22%-39%) vs. without TTM (24%, 95% CI: 14%-34%) ( P = 0.31). A cumulative meta-analysis by publication year showed improved neurological and survival outcomes over time. Conclusions: Among ECPR patients, survival and neurological outcome were not different between those with TTM vs. without TTM. Our study suggests that neurological and survival outcome are improving over time as ECPR therapy is more widely used. Our results were limited by the heterogeneity of included studies and further research with granular temperature data is necessary to assess the benefit and risk of TTM in ECPR population.


Author(s):  
Dongjun Yang ◽  
Wongyu Lee ◽  
Jehyeok Oh

Although the use of audio feedback with devices such as metronomes during cardiopulmonary resuscitation (CPR) is a simple method for improving CPR quality, its effect on the quality of pediatric CPR has not been adequately evaluated. In this study, 64 healthcare providers performed CPR (with one- and two-handed chest compression (OHCC and THCC, respectively)) on a pediatric resuscitation manikin (Resusci Junior QCPR), with and without audio feedback using a metronome (110 beats/min). CPR was performed on the floor, with a compression-to-ventilation ratio of 30:2. For both OHCC and THCC, the rate of achievement of an adequate compression rate during CPR was significantly higher when performed with metronome feedback than that without metronome feedback (CPR with vs. without feedback: 100.0% (99.0, 100.0) vs. 94.0% (69.0, 99.0), p < 0.001, for OHCC, and 100.0% (98.5, 100.0) vs. 91.0% (34.5, 98.5), p < 0.001, for THCC). However, the rate of achievement of adequate compression depth during the CPR performed was significantly higher without metronome feedback than that with metronome feedback (CPR with vs. without feedback: 95.0% (23.5, 99.5) vs. 98.5% (77.5, 100.0), p = 0.004, for OHCC, and 99.0% (95.5, 100.0) vs. 100.0% (99.0, 100.0), p = 0.003, for THCC). Although metronome feedback during pediatric CPR could increase the rate of achievement of adequate compression rates, it could cause decreased compression depth.


Author(s):  
Sylvain Ploux ◽  
Marc Strik ◽  
Saer Abu-Alrub ◽  
F Daniel Ramirez ◽  
Samuel Buliard ◽  
...  

Abstract Background Multiparametric remote monitoring of patients with heart failure (HF) has the potential to mitigate the health risks of lockdowns for COVID-19. Aims To compare health care use, physiological variables, and HF decompensations during one month before and during the first month of the first French national lockdown for COVID-19 among patients undergoing remote monitoring. Methods Transmitted vital parameters and data from cardiac implantable electronic devices were analyzed in 51 patients. Medical contact was defined as the sum of visits and days of hospitalization. Results The lockdown was associated with a marked decrease in cardiology medical contact (118 days before vs 26 days during, -77%, p = 0.003) and overall medical contact (180 days before vs 79 days during, -58%, p = 0.005). Patient adherence with remote monitoring was 84±21% before and 87±19% during lockdown. The lockdown was not associated with significant changes in various parameters, including physical activity (2±1 to 2±1 h/day), weight (83±16 to 83±16 kg), systolic blood pressure (121±19 to 121±18 mmHg), heart rate (68±10 to 67±10 bpm), heart rate variability (89±44 to 78±46 ms, p = 0.05), atrial fibrillation burden (84±146 vs 86±146 h/month), or thoracic impedance (66±8 to 66±9 Ω). Seven cases of HF decompensations were observed before lockdown, all but one of which required hospitalization, versus six during lockdown, all but one of which were managed remotely. Conclusions The lockdown restrictions caused a marked decrease in health care use but no significant change in the clinical status of HF patients under multiparametric remote monitoring. lay summary The first French COVID-19 lockdown had a huge detrimental impact on conventional health care use (-78% in cardiology medical contact). However the lockdown had little impact over the short-term, if any, on vital parameters and the clinical status of patients with heart failure who were adherent to multiparametric remote monitoring. This remote monitoring strategy allowed early identification and home management of most of the heart failure decompensations during the lockdown.


2021 ◽  
Vol 10 (1) ◽  
pp. 161
Author(s):  
Colt A. Coffman ◽  
Jacob J. M. Kay ◽  
Kat M. Saba ◽  
Adam T. Harrison ◽  
Jeffrey P. Holloway ◽  
...  

Objective assessments of concussion recovery are crucial for facilitating effective clinical management. However, predictive tools for determining adolescent concussion outcomes are currently limited. Research suggests that heart rate variability (HRV) represents an indirect and objective marker of central and peripheral nervous system integration. Therefore, it may effectively identify underlying deficits and reliably predict the symptomology following concussion. Thus, the present study sought to evaluate the relationship between HRV and adolescent concussion outcomes. Furthermore, we sought to examine its predictive value for assessing outcomes. Fifty-five concussed adolescents (12–17 years old) recruited from a local sports medicine clinic were assessed during the initial subacute evaluation (within 15 days postinjury) and instructed to follow up for a post-acute evaluation. Self-reported clinical and depressive symptoms, neurobehavioral function, and cognitive performance were collected at each timepoint. Short-term HRV metrics via photoplethysmography were obtained under resting conditions and physiological stress. Regression analyses demonstrated significant associations between HRV metrics, clinical symptoms, neurobehavioral function, and cognitive performance at the subacute evaluation. Importantly, the analyses illustrated that subacute HRV metrics significantly predicted diminished post-acute neurobehavioral function and cognitive performance. These findings indicate that subacute HRV metrics may serve as a viable predictive biomarker for identifying underlying neurological dysfunction following concussion and predict late cognitive outcomes.


Respirology ◽  
2014 ◽  
Vol 20 (2) ◽  
pp. 273-278 ◽  
Author(s):  
Marceli R. Leite ◽  
Ercy Mara C. Ramos ◽  
Carlos A. Kalva-Filho ◽  
Fernanda Maria M. Rodrigues ◽  
Ana Paula C.F. Freire ◽  
...  

2021 ◽  
pp. 026988112097233
Author(s):  
Richard J Xia ◽  
Thomas Chao ◽  
Divya Patel ◽  
Gillinder Bedi

Background: Aspects of the canonical stress response differ in stimulant, opioid, and alcohol users relative to controls, and dysregulated responses to stress may contribute to continued use of these drugs. Little prior research has focused on stress responses in regular cannabis smokers. We assessed responses to a standardized laboratory social stress assay (the Trier Social Stress Task; TSST) in regular cannabis smokers (CANs) compared with controls (CONs). Methods: Healthy, non-treatment-seeking adult CANs (⩾4×/week; smoking cannabis as usual) and demographically matched CONs completed the TSST. Outcome measures were subjective mood, heart rate, and salivary cortisol. Results: Nineteen CANs (1 female) and 20 CONs (2 female) participated; groups were matched on trauma exposure, sex, race, and age. CANs smoked cannabis 6.4 ± 1.1 days/week. Eight CANs and one CON smoked tobacco cigarettes daily. Overall, the TSST produced expected increases in anxiety, negative mood states, cortisol, and heart rate. CANs had blunted subjective response to stress relative to CONs, but they did not differ in physiological (cortisol and cardiovascular) stress responding. Conclusion: These results indicate that CANs have blunted mood responses to social stress, but normative physiological stress responding. Observed differences could be due to residual effects of cannabis, reluctance to endorse negative mood states, or to issues related to identifying (i.e., emotional identification) or feeling (i.e., interoception) stress-related affective states. Further research is warranted to characterize the mechanisms of these differences and assess implications for daily functioning and treatment outcomes.


2018 ◽  
Vol 26 (0) ◽  
Author(s):  
Ana Cláudia Mesquita Garcia ◽  
Talita Prado Simão-Miranda ◽  
Ana Maria Pimenta Carvalho ◽  
Paula Condé Lamparelli Elias ◽  
Maria da Graça Pereira ◽  
...  

ABSTRACT Objective: To investigate the effect of therapeutic listening on state anxiety and surgical fears in preoperative colorectal cancer patients. Method: A randomized controlled trial with 50 patients randomly allocated in the intervention group (therapeutic listening) (n = 25) or in the control group (n = 25). The study evaluated the changes in the variables state anxiety, surgical fears and physiological variables (salivary alpha-amylase, salivary cortisol, heart rate, respiratory rate and blood pressure). Results: In the comparison of the variables in the control and intervention groups in pre- and post-intervention, differences between the two periods for the variables cortisol (p=0.043), heart rate (p=0.034) and surgical fears (p=0.030) were found in the control group, which presented reduction in the values of these variables. Conclusion: There was no reduction in the levels of the variables state anxiety and surgical fears resulting from the therapeutic listening intervention, either through the physiological or psychological indicators. However, the contact with the researcher during data collection, without stimulus to reflect on the situation, may have generated the results of the control group. Clinical Trial Registration: NCT02455128.


Sign in / Sign up

Export Citation Format

Share Document