scholarly journals Mouthguard Use Effect on the Biomechanical Response of an Ankylosed Maxillary Central Incisor during a Traumatic Impact: A 3-Dimensional Finite Element Analysis

Life ◽  
2020 ◽  
Vol 10 (11) ◽  
pp. 294
Author(s):  
Alexandre Luiz Souto Borges ◽  
Amanda Maria de Oliveira Dal Piva ◽  
Laís Regiane da Silva Concílio ◽  
Tarcisio José de Arruda Paes-Junior ◽  
João Paulo Mendes Tribst

(1) Background: Trauma is a very common experience in contact sports; however, there is an absence of data regarding the effect of athletes wearing mouthguards (MG) associated with ankylosed maxillary central incisor during a traumatic impact. (2) Methods: To evaluate the stress distribution in the bone and teeth in this situation, models of maxillary central incisor were created containing cortical bone, trabecular bone, soft tissue, root dentin, enamel, periodontal ligament, and antagonist teeth were modeled. One model received a MG with 4-mm thickness. Both models were subdivided into finite elements. The frictionless contacts were used and a nonlinear dynamic impact analysis was performed in which a rigid object hit the model at 1 m·s−1. For each model, an ankylosed periodontal ligament was simulated totaling 4 different situations. The results were presented in von-Mises stress maps. (3) Results: A higher stress concentration in teeth and bone was observed for the model without a MG and with ankylosed tooth (19.5 and 37.3 MPa, respectively); the most promising mechanical response was calculated for patients with healthy periodontal ligament and MG in position (1.8 and 7.8 MPa, respectively). (4) Conclusions: The MG’s use is beneficial for healthy and ankylosed teeth, since it acts by dampening the generated stresses in bone, dentin, enamel and periodontal ligament. However, patients with ankylosed tooth are more prone to root fracture even when the MG is in position compared to a healthy tooth.

2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Sumedha Kapoor ◽  
Shobha Rodrigues ◽  
M. Mahesh ◽  
Thilak Shetty ◽  
Umesh Pai ◽  
...  

Purpose. The aim of this study was to assess and correlate the stress distribution in an anterior maxillary implant-supported prosthesis with 0°(degree), 15°, and 25° angulated titanium and zirconia abutments using a three-dimensional (3D) finite element analysis (FEA). Materials and Methods. Six FEA models consisting of a dentate anterior maxilla with a single bone-level implant of dimension 4.2 × 10 mm placed in the region of left maxillary central incisor and abutments of dimension 4.2 mm made of titanium and zirconia each with angulation 0° (IA and IB), 15° (IIA and IIB), and 25° (IIIA and IIIB) and ANSYS Workbench software were utilized to design a layered zirconia crown. Unilateral axial and oblique loads of 178 N were applied on the palatal aspect of the crown of left maxillary central incisor. Average von Mises stress values were evaluated in the implant and the peri-implant bone quantitatively and qualitatively. Results. Stress was shown to increase with an increase in angulation in all the areas that were examined. Zirconia abutments showed lesser stress in the implant and surrounding bone than titanium abutments. When compared with the body and apex of the implant, the implant neck values were higher in all models. In between cortical and cancellous bone, the stress recorded was higher in the cortical bone. Conclusion. Within the limitations of this study, straight abutments generated a more uniform and minimal stress in implant and peri-implant bone than angulated abutments. Titanium abutments generated higher stress levels than zirconia abutments. The stresses generated are directly proportional to an increase in abutment angulation, and therefore, straight abutments are most suitable for favourable stress transmission.


Author(s):  
Timothy A. Schmitt ◽  
Taha Al-Shawaf ◽  
Syed M. Rahman ◽  
Angelo Cristobal

As part of the post-Fukushima accident scenario, the qualification of a water-filled cylindrical tank subjected to tornado missile impact was required to ensure the availability of water inventory in the tank to mitigate the post-accident effects. Most of the classical tornado missile impact analysis and design involves using empirical formulas that have been developed based on tests. It is recognized that water backed structures provide additional resistance to perforation of the missile due to the mass and properties of the water. Therefore, a finite element analysis was used to qualify the tank for two controlling postulated missiles, namely, 2 ½” diameter schedule 40 pipe and bolted wood decking. The location on the tank for the missile impact, angle of impact and orientation of the missile were selected to develop the most critical response. The analysis was performed using the LS-DYNA computer program. The true stress-strain material properties were used for both the tank material and the missile types. These material properties were given a bilinear elastic-plastic curve. It was determined that, even if an impact at the thinnest section at the top of the tank occurs and the missile penetrates, the remaining inventory of water in the tank will be sufficient to mitigate the needs for a post-Fukushima scenario. Impact on the lower elevation of the tank was investigated for any potential failure or tearing of the tank wall. The maximum of equivalent (Von Mises) stress, shear stress, and plastic strain were calculated. The results show that these values are less than the limiting values with additional available margin. Consequently the analysis shows that the tank will survive a hit in the lower portions, and the water inventory of the tank is sufficient to mitigate the effect of a post-Fukushima scenario should a missile penetrate the thinner, upper section of the tank.


Author(s):  
Nurullah Türker ◽  
Hümeyra Tercanlı Alkış ◽  
Steven J Sadowsky ◽  
Ulviye Şebnem Büyükkaplan

An ideal occlusal scheme plays an important role in a good prognosis of All-on-Four applications, as it does for other implant therapies, due to the potential impact of occlusal loads on implant prosthetic components. The aim of the present three-dimensional (3D) finite element analysis (FEA) study was to investigate the stresses on abutments, screws and prostheses that are generated by occlusal loads via different occlusal schemes in the All-on-Four concept. Three-dimensional models of the maxilla, mandible, implants, implant substructures and prostheses were designed according to the All-on-Four concept. Forces were applied from the occlusal contact points formed in maximum intercuspation and eccentric movements in canine guidance occlusion (CGO), group function occlusion (GFO) and lingualized occlusion (LO). The von Mises stress values for abutment and screws and deformation values for prostheses were obtained and results were evaluated comparatively. It was observed that the stresses on screws and abutments were more evenly distributed in GFO. Maximum deformation values for prosthesis were observed in the CFO model for lateral movement both in the maxilla and mandible. Within the limits of the present study, GFO may be suggested to reduce stresses on screws, abutments and prostheses in the All-on-Four concept.


2021 ◽  
Vol 11 (6) ◽  
pp. 2547 ◽  
Author(s):  
Carlo Prati ◽  
João Paulo Mendes Tribst ◽  
Amanda Maria de Oliveira Dal Piva ◽  
Alexandre Luiz Souto Borges ◽  
Maurizio Ventre ◽  
...  

The aim of the present investigation was to calculate the stress distribution generated in the root dentine canal during mechanical rotation of five different NiTi endodontic instruments by means of a finite element analysis (FEA). Two conventional alloy NiTi instruments F360 25/04 and F6 Skytaper 25/06, in comparison to three heat treated alloys NiTI Hyflex CM 25/04, Protaper Next 25/06 and One Curve 25/06 were considered and analyzed. The instruments’ flexibility (reaction force) and geometrical features (cross section, conicity) were previously investigated. For each instrument, dentine root canals with two different elastic moduli(18 and 42 GPa) were simulated with defined apical ratios. Ten different CAD instrument models were created and their mechanical behaviors were analyzed by a 3D-FEA. Static structural analyses were performed with a non-failure condition, since a linear elastic behavior was assumed for all components. All the instruments generated a stress area concentration in correspondence to the root canal curvature at approx. 7 mm from the apex. The maximum values were found when instruments were analyzed in the highest elastic modulus dentine canal. Strain and von Mises stress patterns showed a higher concentration in the first part of curved radius of all the instruments. Conventional Ni-Ti endodontic instruments demonstrated higher stress magnitudes, regardless of the conicity of 4% and 6%, and they showed the highest von Mises stress values in sound, as well as in mineralized dentine canals. Heat-treated endodontic instruments with higher flexibility values showed a reduced stress concentration map. Hyflex CM 25/04 displayed the lowest von Mises stress values of, respectively, 35.73 and 44.30 GPa for sound and mineralized dentine. The mechanical behavior of all rotary endodontic instruments was influenced by the different elastic moduli and by the dentine canal rigidity.


Author(s):  
Osezua Obehi Ibhadode ◽  
Ishaya Musa Dagwa ◽  
Akii Okonigbon Akhaehomen Ibhadode

Calibration curves of a multi-component dynamometer is of essence in machining operations in a lathe machine as they serve to provide values of force and stress components for cutting tool development and optimization. In this study, finite element analysis has been used to obtain the deflection and stress response of a two component cutting tool lathe dynamometer, for turning operation, when the cutting tool is subjected to cutting and thrust forces from 98.1N to 686.7N (10 to 70kg-wts), at intervals of 98.1N(10kg-wt). By obtaining the governing equation, modeling the dynamometer assembly, defining boundary conditions, generating the assembly mesh, and simulating in Inventor Professional; horizontal and vertical components of deflection by the dynamometer were read off for three different loading scenarios. For these three loading scenarios, calibration plots by experiment compared with plots obtained from simulation by finite element analysis gave accuracies of 79%, 95%, 84% and 36%, 57%, 63% for vertical and horizontal deflections respectively. Also, plots of horizontal and vertical components of Von Mises stress against applied forces were obtained.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Charles Savoldelli ◽  
Elodie Ehrmann ◽  
Yannick Tillier

AbstractWith modern-day technical advances, high sagittal oblique osteotomy (HSOO) of the mandible was recently described as an alternative to bilateral sagittal split osteotomy for the correction of mandibular skeletal deformities. However, neither in vitro nor numerical biomechanical assessments have evaluated the performance of fixation methods in HSOO. The aim of this study was to compare the biomechanical characteristics and stress distribution in bone and osteosynthesis fixations when using different designs and placing configurations, in order to determine a favourable plating method. We established two finite element models of HSOO with advancement (T1) and set-back (T2) movements of the mandible. Six different configurations of fixation of the ramus, progressively loaded by a constant force, were assessed for each model. The von Mises stress distribution in fixations and in bone, and bony segment displacement, were analysed. The lowest mechanical stresses and minimal gradient of displacement between the proximal and distal bony segments were detected in the combined one-third anterior- and posterior-positioned double mini-plate T1 and T2 models. This suggests that the appropriate method to correct mandibular deformities in HSOO surgery is with use of double mini-plates positioned in the anterior one-third and posterior one-third between the bony segments of the ramus.


2018 ◽  
Vol 7 (4.26) ◽  
pp. 190 ◽  
Author(s):  
Nur Fatin Izzati Ibrahim ◽  
Ruslizam Daud ◽  
Muhammad Khairul Ali Hassan ◽  
Noor Ali Hassan ◽  
Noor Alia Md Zain ◽  
...  

Axial stiffness is the most important factor in stability. It is known that any changes in the diameter of any components of the frame will either increase or decrease the axial stiffness of the fixation. The model of implant and bone will be variety as the variables changes. Current studies states that ring stability are one of the most important factors in ensuring fractured bones to have a successful re-union. In circular external fixation, the stability of the pin-bone interaction is influenced by the stability of the fixation frame where the major component is the rings. The objective is to study the finite element analysis (FEA) of the external fixator assembled in human diaphysis under compression force with different materials of the exoskeleton which are stainless steel, titanium alloy, magnesium alloy and carbon fiber. The results obtained show the mechanical strength of each material where it will be used to compare the value of von-Mises stress, stiffness and total deformation to acquire the best suitable ring diameter and material. Based on the result, as the diameter of the ring increases, the stiffness of the ring will be decreased. 


2020 ◽  
Vol 5 (10) ◽  
pp. 1288-1293
Author(s):  
Panagiotis J. Charitidis

The present study concerns with the finite element investigation of balanced aluminium single lap joints subjected to tensile loading. Epoxy adhesives were used for bonding having different nanoparticles rate in the epoxy resin (0.5, 1.0, 1.5 and to 2 wt. %, respectively). Two-dimensional (2D) finite element analysis has been employed to determine the peeling stress, von Mises stress, and the shear strain distribution across the midplane of the joints. The results mainly prove that the nanoparticles rate in the adhesive material directly affects the joint tensile strength. Nanocomposite adhesives present a higher failure load than that of neat adhesives. Furthermore, nanocomposite adhesive with 0.5 wt. % of nanoparticles generated strengths (shear and peeling strengths) more than neat adhesives, after which decreased by further addition of the nanoparticles.


Sign in / Sign up

Export Citation Format

Share Document