scholarly journals Optimization of Adsorbent Layer Type and Developing Solvent in Coccidiostats Sample Preparation with Procedure of Solvent Front Position Extraction

Molecules ◽  
2020 ◽  
Vol 25 (24) ◽  
pp. 6011
Author(s):  
Maciej Jan Rybicki ◽  
Anna Klimek-Turek ◽  
Tadeusz Henryk Dzido

Coccidiostats are drugs used against coccidiosis, a common disease among breeding animals. Their widespread application leads to the appearance of their residues in food, which is potentially harmful for human health and life. The European Union has established limits of concentrations of these drugs in premixtures and food. Nowadays, there are many methods for monitoring coccidiostats’ presence in market products, but their frequent weakness is sample preparation. Solvent Front Position Extraction is a planar chromatography-based sample preparation method that allows for effective assay of samples with coccidiostats when coupled with LC-MS/MS. The purpose of this research was to find common conditions for the effective isolation of eight coccidiostats from biological sample components with both lower and higher retention than the substances of interest. The acquired results were used for effective isolation of monensin and salinomycin from the premixture samples and allowed for their quantitative determination. The application of a semi-automatic device for the development of chromatograms positively impacted the results, confirming the effectiveness of the method for determining coccidiostats in biological samples.

Molecules ◽  
2019 ◽  
Vol 24 (7) ◽  
pp. 1358 ◽  
Author(s):  
Anna Klimek-Turek ◽  
Kamila Jaglińska ◽  
Magdalena Imbierowicz ◽  
Tadeusz Dzido

The new prototype device is applied to the Solvent Front Position Extraction (SFPE) sample preparation procedure. The mobile phase is deposited onto the chromatographic plate adsorbent layer by the pipette, which is moved, according to programmed movement path, by a 3D printer mechanism. The application of the prototype device to SFPE procedure leads to the increased repeatability of the results and significant reduction of the analysis time in comparison to the classical procedure of chromatogram development. Additionally, the new equipment allows use procedures that are not possible to run using the classic chromatogram development. In this paper, the results of manual and semi-automatic sample preparation with SFPE are compared and the possible application of this prototype device is discussed.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Anna Klimek-Turek ◽  
Adam Chomicki ◽  
Emilia Fornal ◽  
Anna Pradiuch ◽  
Michał Hys ◽  
...  

Abstract In the paper the results of the tryptophan determination in human plasma samples prepared with the novel Solvent Front Position Extraction (SFPE) technique are presented. The SFPE procedure is used for preparation of real biological sample for the first time. The results obtained using SFPE are compared with those using the classical sample preparation procedure. Under the optimal conditions, tryptophan and its internal standard were separated from other plasma compounds (matrix) as a small common zone/spot on a chromatographic plate using semiautomatic device equipped with moving pipet, which distributed developing solvent on the adsorbent layer. Tryptophan and the internal standard were evenly distributed within the small common zone from that the both substances were extracted and the solution obtained was transferred to quantitation with LC–MS and MS techniques. The determination results are satisfactory, the percentage values of relative error and RSD relative standard deviation do not exceed 5%. The procedure is characterized by simplicity, high analysis throughput, very good sample purification and seems to be easy applicable to other biological samples with these advantages mentioned.


Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


Author(s):  
Swaminathan Subramanian ◽  
Khiem Ly ◽  
Tony Chrastecky

Abstract Visualization of dopant related anomalies in integrated circuits is extremely challenging. Cleaving of the die may not be possible in practical failure analysis situations that require extensive electrical fault isolation, where the failing die can be submitted of scanning probe microscopy analysis in various states such as partially depackaged die, backside thinned die, and so on. In advanced technologies, the circuit orientation in the wafer may not align with preferred crystallographic direction for cleaving the silicon or other substrates. In order to overcome these issues, a focused ion beam lift-out based approach for site-specific cross-section sample preparation is developed in this work. A directional mechanical polishing procedure to produce smooth damage-free surface for junction profiling is also implemented. Two failure analysis applications of the sample preparation method to visualize junction anomalies using scanning microwave microscopy are also discussed.


Molecules ◽  
2021 ◽  
Vol 26 (8) ◽  
pp. 2277
Author(s):  
Piotr M. Kuś ◽  
Igor Jerković

Recently, we proposed a new sample preparation method involving reduced solvent and sample usage, based on dehydration homogeneous liquid–liquid extraction (DHLLE) for the screening of volatiles and semi-volatiles from honey. In the present research, the method was applied to a wide range of honeys (21 different representative unifloral samples) to determine its suitability for detecting characteristic honey compounds from different chemical classes. GC-FID/MS disclosed 130 compounds from different structural and chemical groups. The DHLLE method allowed the extraction and identification of a wide range of previously reported specific and nonspecific marker compounds belonging to different chemical groups (including monoterpenes, norisoprenoids, benzene derivatives, or nitrogen compounds). For example, DHLLE allowed the detection of cornflower honey chemical markers: 3-oxo-retro-α-ionols, 3,4-dihydro-3-oxoedulan, phenyllactic acid; coffee honey markers: theobromine and caffeine; linden honey markers: 4-isopropenylcyclohexa-1,3-diene-1-carboxylic acid and 4-(2-hydroxy-2-propanyl)cyclohexa-1,3-diene-1-carboxylic acid, as well as furan derivatives from buckwheat honey. The obtained results were comparable with the previously reported data on markers of various honey varieties. Considering the application of much lower volumes of very common reagents, DHLLE may provide economical and ecological advantages as an alternative sample preparation method for routine purposes.


Molecules ◽  
2021 ◽  
Vol 26 (8) ◽  
pp. 2350
Author(s):  
Jianing Zhang ◽  
Fengjie Yu ◽  
Yunmin Tao ◽  
Chunping Du ◽  
Wenchao Yang ◽  
...  

In the present work, a novel sample preparation method, micro salting-out assisted matrix solid-phase dispersion (μ-SOA-MSPD), was developed for the determination of bisphenol A (BPA) and bisphenol B (BPB) contaminants in bee pollen. The proposed method was designed to combine two classical sample preparation methodologies, matrix solid-phase dispersion (MSPD) and homogenous liquid-liquid extraction (HLLE), to simplify and speed-up the preparation process. Parameters of μ-SOA-MSPD were systematically investigated, and results indicated the significant effect of salt and ACN-H2O extractant on the signal response of analytes. In addition, excellent clean-up ability in removing matrix components was observed when primary secondary amine (PSA) sorbent was introduced into the blending operation. The developed method was fully validated, and the limits of detection for BPA and BPB were 20 μg/kg and 30 μg/kg, respectively. Average recoveries and precisions were ranged from 83.03% to 94.64% and 1.76% to 5.45%, respectively. This is the first report on the analysis of bisphenol contaminants in bee pollen sample, and also on the combination of MSPD and HLLE. The present method might provide a new strategy for simple and fast sample preparation of solid and semi-solid samples.


Sign in / Sign up

Export Citation Format

Share Document