scholarly journals Combination of Capped Gold Nanoslit Array and Electrochemistry for Sensitive Aqueous Mercuric Ions Detection

Nanomaterials ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 88
Author(s):  
Cheng-Chuan Chen ◽  
Shu-Cheng Lo ◽  
Pei-Kuen Wei

Label-free surface plasmon resonance (SPR) detection of mercuric ions in various aqueous solutions, using capped gold nanoslit arrays combined with electrochemical (EC) sensing technique, is demonstrated. The nanoslit arrays are fabricated on flexible cyclo-olefin polymer substrates by a nanoimprinting lithography method. The EC and SPR signals for the investigation of current responses and transmission SPR spectra are simultaneously measured during metal ions electrodeposition. Glycerol–water solution is studied to evaluate the resonant peak wavelength sensitivity (480.3 nm RIU−1) with a FOM of 40.0 RIU−1 and the obtained intensity sensitivity is 1819.9%. The ferrocyanide/ferricyanide redox couple performs the diffusion controlled electrochemical processes (R2 = 0.99). By investigating the SPR intensity changes and wavelength shifts of various mercuric ion concentrations, the optical properties are evaluated under chronoamperometric conditions. The sensors are evaluated in the detection range between 100 μM and 10 nM with a detection limit of 1 μM. The time dependence of SPR signals and the selectivity of 10 μM Hg2+ in the presence of 10 μM interfering metal ion species from Ca2+, Co2+, Ni2+, Na+, Cu2+, Pb2 + and Mn2+ are determined. The capped gold nanoslit arrays show the selectivity of Hg2+ and the EC sensing method is effectively utilized to aqueous Hg2+ detection. This study provides a label-free detection technique of mercuric ions and this developed system is potentially applicable to detecting chemicals and biomolecules.

MRS Advances ◽  
2018 ◽  
Vol 3 (26) ◽  
pp. 1491-1496
Author(s):  
Natalie Hughes ◽  
Nancy Nguyen ◽  
Deanna-Kaye Daley ◽  
Justin Grennell ◽  
Amira Gee ◽  
...  

ABSTRACTPoint-of-care systems require highly sensitive, quantitative and selective detection platforms for the real-time multiplexed monitoring of target analytes. To ensure facile development of a sensor, it is preferable for the detection assay to have minimal chemical complexity, contain no wash steps and provide a wide and easily adaptable detection range for multiple targets. Current studies involve label-free detection strategy for relevant clinical molecules such as heme using G-quadruplex based self-assembly. We have explored the measurement of binding and kinetic parameters of various G-quadruplex/heme complexes which are able to self-associate to form a DNAzyme with peroxidase mimicking capabilities and are critical to nucleic acid research. The detection strategy includes immobilizing the G-quadruplex sequences within a polymer matrix to provide a self-assembly based detection approach for heme that could be translated towards other clinically relevant targets.


2018 ◽  
Vol 44 (3) ◽  
pp. 2869-2883 ◽  
Author(s):  
Raji Atchudan ◽  
Thomas Nesakumar Jebakumar Immanuel Edison ◽  
Dasagrandhi Chakradhar ◽  
Namachivayam Karthik ◽  
Suguna Perumal ◽  
...  

2021 ◽  
Vol 13 (15) ◽  
pp. 1832-1838
Author(s):  
Jiaxi Cheng ◽  
Fenghua Jiang ◽  
Siqi Zhang

We develop a label-free, sensitive and selective nanochannel sensing platform for detection of TC. The nanosensor provided a low detection limit, a wide detection range and excellent recovery rate in different water samples.


Author(s):  
Wei-Jhen Wang ◽  
Chia-Hwa Lee ◽  
Chin-Wen Li ◽  
Stephen Liao ◽  
Fuh-Jyh Jan ◽  
...  

Abstract In this study, a label-free detection approach for effective detection of the odontoglossum ringspot virus (ORSV) infected orchids has been developed. We used semiconductor fabrication process to fabricate 1,810 micro/nano hybrid structured sensing electrodes on a 8 inch reclaimed wafer. The self-assembled monolayer (SAM) process was then employed to sequentially modify the electrode surface with 11-mercaptoundecanoic acid (11-MUA), 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC)/ N-hydroxysuccinimide (NHS), anti-ORSV, and ORSV. EIS was conducted for the ORSV concentration detection. Experimental results demonstrated that the ORSV concentration in a virus infected orchid leaf could be effectively detected. When compared with the ELISA kit, our device possesses a wider linear detection range (0.5–50,000 ng/mL) and a higher sensitivity. The specificity of our device on ORSV detection was also confirmed. Our sensing device retains advantages, such as label-free, lower amounts of the antibody and target sample required, low detection time, and a wider linear detection range. Those results imply the feasibility of our sensing device in field applications.


Toxins ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 43
Author(s):  
Inna Székács ◽  
Nóra Adányi ◽  
István Szendrő ◽  
András Székács

Novel optical waveguide lightmode spectroscopy (OWLS)-based immunosensor formats were developed for label-free detection of Fusarium mycotoxin zearalenone (ZON). To achieve low limits of detection (LODs), both immobilised antibody-based (direct) and immobilised antigen-based (competitive) assay setups were applied. Immunoreagents were immobilised on epoxy-, amino-, and carboxyl-functionalised sensor surfaces, and by optimising the immobilisation methods, standard sigmoid curves were obtained in both sensor formats. An outstanding LOD of 0.002 pg/mL was obtained for ZON in the competitive immunosensor setup with a dynamic detection range between 0.01 and 1 pg/mL ZON concentrations, depending on the covalent immobilisation method applied. This corresponds to a five orders of magnitude improvement in detectability of ZON relative to the previously developed enzyme-linked immonosorbent assay (ELISA) method. The selectivity of the immunosensor for ZON was demonstrated with structural analogues (α-zearalenol, α-zearalanol, and β-zearalanol) and structurally unrelated mycotoxins. The method was found to be applicable in maize extract using acetonitrile as the organic solvent, upon a dilution rate of 1:10,000 in buffer. Thus, the OWLS immunosensor method developed appears to be suitable for the quantitative determination of ZON in aqueous medium. The new technique can widen the range of sensoric detection methods of ZON for surveys in food and environmental safety assessment.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2655
Author(s):  
Giorgia Giovannini ◽  
Denis Garoli ◽  
Patrick Rupper ◽  
Antonia Neels ◽  
René M. Rossi ◽  
...  

Thanks to its negative surface charge and high swelling behavior, montmorillonite (MMT) has been widely used to design hybrid materials for applications in metal ion adsorption, drug delivery, or antibacterial substrates. The changes in photophysical and photochemical properties observed when fluorophores interact with MMT make these hybrid materials attractive for designing novel optical sensors. Sensor technology is making huge strides forward, achieving high sensitivity and selectivity, but the fabrication of the sensing platform is often time-consuming and requires expensive chemicals and facilities. Here, we synthesized metal-modified MMT particles suitable for the bio-sensing of self-fluorescent biomolecules. The fluorescent enhancement achieved by combining clay minerals and plasmonic effect was exploited to improve the sensitivity of the fluorescence-based detection mechanism. As proof of concept, we showed that the signal of fluorescein isothiocyanate can be harvested by a factor of 60 using silver-modified MMT, while bovine serum albumin was successfully detected at 1.9 µg/mL. Furthermore, we demonstrated the versatility of the proposed hybrid materials by exploiting their plasmonic properties to develop liquid label-free detection systems. Our results on the signal enhancement achieved using metal-modified MMT will allow the development of highly sensitive, easily fabricated, and cost-efficient fluorescent- and plasmonic-based detection methods for biomolecules.


Polymers ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1026
Author(s):  
Elisa Chiodi ◽  
Allison M. Marn ◽  
Matthew T. Geib ◽  
M. Selim Ünlü

The importance of microarrays in diagnostics and medicine has drastically increased in the last few years. Nevertheless, the efficiency of a microarray-based assay intrinsically depends on the density and functionality of the biorecognition elements immobilized onto each sensor spot. Recently, researchers have put effort into developing new functionalization strategies and technologies which provide efficient immobilization and stability of any sort of molecule. Here, we present an overview of the most widely used methods of surface functionalization of microarray substrates, as well as the most recent advances in the field, and compare their performance in terms of optimal immobilization of the bioreceptor molecules. We focus on label-free microarrays and, in particular, we aim to describe the impact of surface chemistry on two types of microarray-based sensors: microarrays for single particle imaging and for label-free measurements of binding kinetics. Both protein and DNA microarrays are taken into consideration, and the effect of different polymeric coatings on the molecules’ functionalities is critically analyzed.


Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1872
Author(s):  
Holger Schulze ◽  
Harry Wilson ◽  
Ines Cara ◽  
Steven Carter ◽  
Edward N. Dyson ◽  
...  

Rapid point of care tests for bacterial infection diagnosis are of great importance to reduce the misuse of antibiotics and burden of antimicrobial resistance. Here, we have successfully combined a new class of non-biological binder molecules with electrochemical impedance spectroscopy (EIS)-based sensor detection for direct, label-free detection of Gram-positive bacteria making use of the specific coil-to-globule conformation change of the vancomycin-modified highly branched polymers immobilized on the surface of gold screen-printed electrodes upon binding to Gram-positive bacteria. Staphylococcus carnosus was detected after just 20 min incubation of the sample solution with the polymer-functionalized electrodes. The polymer conformation change was quantified with two simple 1 min EIS tests before and after incubation with the sample. Tests revealed a concentration dependent signal change within an OD600 range of Staphylococcus carnosus from 0.002 to 0.1 and a clear discrimination between Gram-positive Staphylococcus carnosus and Gram-negative Escherichia coli bacteria. This exhibits a clear advancement in terms of simplified test complexity compared to existing bacteria detection tests. In addition, the polymer-functionalized electrodes showed good storage and operational stability.


Sign in / Sign up

Export Citation Format

Share Document