scholarly journals Lamb-Wave-Based Multistage Damage Detection Method Using an Active PZT Sensor Network for Large Structures

Sensors ◽  
2019 ◽  
Vol 19 (9) ◽  
pp. 2010 ◽  
Author(s):  
Hameed ◽  
Li ◽  
Chen ◽  
Qi

A multistage damage detection method is introduced in this work that uses piezoelectric lead zirconate titanate (PZT) transducers to excite/sense the Lamb wave signals. A continuous wavelet transformation (CWT), based on the Gabor wavelet, is applied to accurately process the complicated wave signals caused by the damage. For a network of transducers, the damage can be detected in one detection cell based on the signals scattered by the damage, and then it can be quantitatively estimated by three detection stages using the outer tangent circle and least-squares methods. First, a single-stage damage detection method is carried out by exciting a transducer at the center of the detection cell to locate the damaged subcell. Then, the corner transducers are excited in the second and third stages of detection to improve the damage detection, especially the size estimation. The method does not require any baseline signal, and it only utilizes the same arrangement of transducers and the same data processing technique in all stages. The results from previous detection stages contribute to the improvement of damage detection in the subsequent stages. Both numerical simulation and experimental evaluation were used to verify that the method can accurately quantify the damage location and size. It was also found that the size of the detection cell plays a vital role in the accuracy of the results in this Lamb-wave-based multistage damage detection method.

Author(s):  
M. Saqib Hameed ◽  
Zheng Li ◽  
Kaihong Zheng

Abstract A Multistage Elliptical Parametric (MEP) method is developed in this research for damage size evaluation in anisotropic composite laminates. The Lamb waves are actuated and sensed using piezoelectric (lead zirconate titanate, PZT) transducers arranged as a network of square cells. The dynamic response signals are processed using a continuous wavelet transformation (CWT) based on the Gabor wavelet for accurate time of flight (ToF) measurements. A numerical method is developed for the construction of non-elliptic path loci for each actuator-sensor pair. The damage is localized first using the least squares method, and then the damage edge points are located on each non-elliptic path loci as points which have the minimum distance from the damage location. The MEP method based on the damage edge points is implemented in multiple stages for damage size evaluation in a cross-ply laminate. Each stage is designed on the basis on excitation of specific prearranged transducers inside the square cell. The results indicate that the MEP method can quantitatively estimate the size of an elliptical damage in cross-ply laminates.


Author(s):  
Bao Chi Ha ◽  
Kevin Gilbert ◽  
Gang Wang

Because of their electro-mechanical coupling property, Lead-Zirconate-Titanate (PZT) materials have been widely used for ultrasonic wave sensing and actuation in structural health monitoring applications. In this paper, a PZT rosette concept is proposed to conduct Lamb wave-based damage detection in panel-like structures by exploring its best directional sensing capability. First, a directivity study was conducted to investigate sensing of flexural Lamb wave propagation using a PZT fiber having d33 effects. Then, commercial off-the-shelf PZT fibers were polarized in-house in order to construct the PZT rosette configuration, in which three PZT fibers are oriented at 0°, 45°, 90°, respectively. Since Lamb wave responses are directly related to measured PZT fiber voltage signals, a simple interrogation scheme was developed to calculate principal strain direction in order to locate an acoustic source. Comprehensive tests were conducted to evaluate the performance of the proposed PZT rosette using an aluminum plate. It is shown that the PZT rosette is able to sense Lamb wave responses and accurately locate an acoustic source. We expect to further evaluate the PZT rosette performance when damages are introduced.


2021 ◽  
Vol 9 (1) ◽  
pp. 1321-1328
Author(s):  
Abdul Aziz Khan J , Shanmugaraja P , Kannan S

MEMS Energy Harvesting(EH) devices are excepted to grow in the upcoming years, due to the increasing aspects of MEMS EH devices in vast applications. In Recent advancements in energy harvesting (EH) technologies wireless sensor devices play a vital role to extend their lifetime readily available in natural resources. In this paper the design of MEMS Cantilever at low frequency (100Hz) with different piezoelectric materials Gallium Arsenide (GaAs), Lead Zirconate Titanate (PZT-8), Tellurium Dioxide (TeO2), Zinc oxide (ZnO) is simulated and performance with different materials are compared. The results are analyzed with various parameters such as electric potential voltage, von mises stress, displacement. The paper discusses the suitability of the piezoelectric material for MEMS fully cochlear implantable sensor application.


2019 ◽  
Vol 19 (2) ◽  
pp. 339-356 ◽  
Author(s):  
Balamonica K ◽  
Jothi Saravanan T ◽  
Bharathi Priya C ◽  
Gopalakrishnan N

Structural damage detection using unmanned Structural Health Monitoring techniques is becoming the need of the day with the technologies available presently. Sensors made of Lead Zirconate Titanate materials, due to their simplicity and robustness, are increasingly used as an effective monitoring sensor in Structural Health Monitoring. Continuous monitoring of the structures using Lead Zirconate Titanate sensors often results in a laborious data retrieval process due to the large amount of signal generated. To speed up the data retrieval process, a multi-sensing technique in which the Lead Zirconate Titanate patches are connected in series and parallel is proposed for structural damage detection. The proposed method is validated using an experimental investigation carried out on a reinforced concrete beam embedded with smart Lead Zirconate Titanate sensor units. The beam is subjected to damage, and the location of damage is identified using conductance signatures obtained from patches sensed individually and through multiplexing. This article proposes an effective methodology for selection of patches to be connected in series/parallel to maximise the efficiency of damage detection. Damage quantification using conventional statistical metrics such as root mean square deviation, mean absolute percentage deviation and cross correlations are found to be ineffective in identifying the location of damage from the multiplexed signatures. In turn, dynamic metrics such as moving root mean square deviation, moving mean absolute percentage deviation and moving cross correlation with overlapped moving blocks of data are proposed in the present work and their ability to detect the damage location from multiplexed signatures is discussed.


1999 ◽  
Vol 14 (7) ◽  
pp. 2940-2944 ◽  
Author(s):  
Fei Fang ◽  
Wei Yang ◽  
Ting Zhu

Lanthanum-modified lead zirconate titanate ferroelectric ceramics (Pb0.96La0.04)(Zr0.40Ti0.60)0.99O3 were synthesized by the conventional powder processing technique. X-ray diffraction experiments revealed that the samples belong to the tetragonal phase with a = b = 0.4055 nm, c = 0.4109 nm, and c/a = 1.013. After being poled, the samples were indented with a 5-kg Vickers indenter, and lateral electric fields of 0.4 Ec, 0.5 Ec, and 0.6 Ec (Ec = 1100 V/mm) were applied, respectively. Field-emission scanning electron microscopy showed that 90° domain switching appeared near the tip of the indentation crack under a lateral electric field of 0.6 Ec. A mechanism of 90° domain switching near the crack tip under an electric field is discussed.


2020 ◽  
Vol 31 (16) ◽  
pp. 1898-1909
Author(s):  
Qijian Liu ◽  
Yuan Chai ◽  
Xinlin Qing

A variety of structural health monitoring techniques have been developed to support the efficient online monitoring of structural integrity. Moreover, Lamb wave and electromechanical impedance methods are increasingly used for structural health monitoring applications due to their high sensitivity and effectiveness in detecting damage. However, these techniques require transducers to be permanently attached to structures because of the usage of baselines recorded under the condition without damage. In this study, a reusable piezoelectric lead zirconate titanate transducer for monitoring corrosion damage on the aluminum plate is introduced, which can be removed from the test specimen and reused with the repeatability of signals. The reusable piezoelectric lead zirconate titanate transducer is bonded on the aluminum plate using the ethylene-acrylic acid copolymer with an aluminum enclosure. A series of experiments are conducted on an aluminum plate, including the investigation for repeatability of signals and the capability of corrosion detection of the designed piezoelectric lead zirconate titanate transducer through the Lamb wave and electromechanical impedance methods. The simulated corrosion defect with the area of 15 × 15 mm2 is detected during experiments. The experimental results confirm that the reusable piezoelectric lead zirconate titanate transducer can effectively evaluate the corrosion damage to plate structure and can be reused many times.


Sign in / Sign up

Export Citation Format

Share Document