scholarly journals Hygrothermal Performance of Worship Spaces: Preservation, Comfort, and Energy Consumption

2018 ◽  
Vol 10 (11) ◽  
pp. 3838 ◽  
Author(s):  
Carmen Muñoz-González ◽  
Ángel León-Rodríguez ◽  
Rafael Suárez Medina ◽  
Catherine Teeling

The energy problem, one the most important on a global scale, greatly affects the environment. Much of the current energy consumption occurs in existing buildings, including heritage buildings with varying protected status. Energy intervention and heritage conservation conflict to some extent, as research focuses more on the search for improved energy efficiency solutions for materials and systems than on their application to heritage buildings. This study describes experimental research on environmental conditioning techniques in spaces of worship in a temperate climate in southern Spain. Buildings were monitored and assessed in the implementation of different environmental techniques—active and combined (passive and active)—with the aim of improving the thermal comfort conditions of the faithful while preserving the cultural heritage of these buildings. The need for a control system of RH and the air system was concluded, as well as radiant floors and radiators, which, in the considered case studies, would barely affect the artworks. 24- and 12-h operation are better suited to heritage preservation than occasional use. All operation schedules are valid for thermal comfort.

Energies ◽  
2019 ◽  
Vol 13 (1) ◽  
pp. 81 ◽  
Author(s):  
Małgorzata Fedorczak-Cisak ◽  
Katarzyna Nowak ◽  
Marcin Furtak

Improving the energy efficiency of buildings is among the most urgent social development tasks due to the scale of energy consumption in this industry. At the same time, it is essential to meet high requirements for indoor environmental quality and thermal comfort. The issue of overheating is most often analysed in summer but it also occurs in transition seasons, when the cooling systems do not operate. The paper attempts to evaluate the effectiveness of external mobile shading elements on the microclimate of rooms with large glazed areas in the transition season. Passive solutions, such as shading elements, which limit the increase of indoor temperature, do not always allow the acquisition and maintenance of comfortable solutions for the duration of the season, as demonstrated by the authors. Temporary cooling of the rooms may be necessary to maintain comfortable conditions for the users, or other solutions should be devised to improve comfort (e.g., reduction of clothing insulation characteristics). The novelty of the study consists in the analysis of comfort in a “nearly zero energy consumption” building (NZEB) during a period not analyzed by other scientists. This is a transition period during which heating/cooling systems do not operate. The research task set by the authors involved the assessment of the possibility to reduce office space overheating in the transition season (spring) by using external shading equipment in rooms with large glazed areas. An additional research task aimed at checking the extent to which user behaviour, such as reduction in clothing insulation characteristics, can improve comfort in overheated rooms. The results of the tests reveal that the difference in the ambient air temperature between a room with external venetian blinds and an identical room with no venetian blinds in the transition season, i.e., from 27 March to 6 April 2017, ranged from 12.3 to 2.1 °C. The use of a shading system (external venetian blinds positioned at an angle of 45°) reduced the number of discomfort hours by 92% (during working hours) compared to the room without external venetian blinds. A reduction in the thermal insulation of the clothes worn by people working in the room with no venetian blinds helped to reduce the number of discomfort hours by 31%.


2019 ◽  
pp. 53-65
Author(s):  
Renata Domingos ◽  
Emeli Guarda ◽  
Elaise Gabriel ◽  
João Sanches

In the last decades, many studies have shown ample evidence that the existence of trees and vegetation around buildings can contribute to reduce the demand for energy by cooling and heating. The use of green areas in the urban environment as an effective strategy in reducing the cooling load of buildings has attracted much attention, though there is a lack of quantitative actions to apply the general idea to a specific building or location. Due to the large-scale construction of high buildings, large amounts of solar radiation are reflected and stored in the canyons of the streets. This causes higher air temperature and surface temperature in city areas compared to the rural environment and, consequently, deteriorates the urban heat island effect. The constant high temperatures lead to more air conditioning demand time, which results in a significant increase in building energy consumption. In general, the shade of the trees reduces the building energy demand for air conditioning, reducing solar radiation on the walls and roofs. The increase of urban green spaces has been extensively accepted as effective in mitigating the effects of heat island and reducing energy use in buildings. However, by influencing temperatures, especially extreme, it is likely that trees also affect human health, an important economic variable of interest. Since human behavior has a major influence on maintaining environmental quality, today's urban problems such as air and water pollution, floods, excessive noise, cause serious damage to the physical and mental health of the population. By minimizing these problems, vegetation (especially trees) is generally known to provide a range of ecosystem services such as rainwater reduction, air pollution mitigation, noise reduction, etc. This study focuses on the functions of temperature regulation, improvement of external thermal comfort and cooling energy reduction, so it aims to evaluate the influence of trees on the energy consumption of a house in the mid-western Brazil, located at latitude 15 ° S, in the center of South America. The methodology adopted was computer simulation, analyzing two scenarios that deal with issues such as the influence of vegetation and tree shade on the energy consumption of a building. In this way, the methodological procedures were divided into three stages: climatic contextualization of the study region; definition of a basic dwelling, of the thermophysical properties; computational simulation for quantification of energy consumption for the four facade orientations. The results show that the façades orientated to north, east and south, without the insertion of arboreal shading, obtained higher values of annual energy consumption. With the adoption of shading, the facades obtained a consumption reduction of around 7,4%. It is concluded that shading vegetation can bring significant climatic contribution to the interior of built environments and, consequently, reduction in energy consumption, promoting improvements in the thermal comfort conditions of users.


2021 ◽  
Vol 13 (8) ◽  
pp. 4563
Author(s):  
Nuno Baía Baía Saraiva ◽  
Luisa Dias Dias Pereira ◽  
Adélio Rodrigues Gaspar ◽  
José Joaquim da Costa

The adaptation of spaces to different usage typologies can be complex in heritage buildings. Facilities were initially planned for a specific type of use that, when changed, require additional measures to ensure a suitable indoor environment. Passive strategies—e.g., free cooling—are commonly used as an alternative without requiring equipment installation. However, its implementation often leads to unsatisfactory conditions. Therefore, it is important to clarify the main barriers to achieving thermal comfort in readapted historic buildings. The present work investigates the thermal comfort conditions reported by workers in office spaces of a historic building in the University of Coimbra. A monitoring campaign was carried out between May and September 2020 to assess indoor conditions’ quality. Due to the current pandemic of COVID-19, offices were not occupied at full capacity. A one-day evaluation of thermal comfort was made using a climate analyzer and six occupants were surveyed on 19 August 2020. The main results highlighted discomfort due to overheating of spaces. The causes were related to the combination of inadequate implementation of the free cooling actions and the building use. Furthermore, it was recommended the installation of HVAC systems in case of full capacity.


2011 ◽  
Vol 216 ◽  
pp. 176-180
Author(s):  
Yong Ding ◽  
Yue Mei Su

Wireless Sensor Networks functionality is closely related to network lifetime which depends on the energy consumption, so require energy- efficient protocols to improve the network lifetime. According to the analysis and summary of the current energy efficient estimation algorithms in wireless sensor network An energy-efficient algorithm is proposed,. Then this optimization algorithm proposed in the paper is adopted to improve the traditional diffusion routing protocol. Simulation results show that this algorithm is to effectively balance the network energy consumption, improve the network life-cycle and ensure the communication quality.


Author(s):  
Edita Povilaitytė-Leliugienė

The analyses of interwar Vilnius heritage preservation, research, and maintenance concentrated mostly on discussions about the general law, state tendency, and case studies of good and bad practices. However, the more modern heritage preservation, research, or maintenance theories and aspects during the interwar period were neglected. Therefore, this article aims to analyse if modern technologies, ideas, and methods in the heritage research and maintenance (mostly in the reconstructions and adaptation of heritage buildings for new purposes) projects were adapted or not in interwar Vilnius. According to this aim, the article analyses a few heritage maintenance works and emphasises how architects used new technologies, modern architecture details, and ideas in the heritage maintenance projects and their realisation. Technologies as central heating system, electrification, canalisation, toilets, or bright interiors, wide air-spaces were inseparable from modernism perspective. The architecture of buildings and urban structures were modernised and improved for better living quality. Also, ideas and technologies did not avoid the heritage objects, especially civil buildings as Vilnius Town Hall, squares as Cathedral square, defensive heritage object as Vilnius Upper Castle. However, the analysis maintains that modern technologies were used moderately and kept a respectful tone with the authentic heritage, whole complex, and elements.


2014 ◽  
Vol 493 ◽  
pp. 74-79
Author(s):  
Y.A. Sabtalistia ◽  
S.N.N. Ekasiwi ◽  
B. Iskandriawan

Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixture of windows, exterior walls, kitchen, and occupants in the studio apartment affect thermal comfort in the room too.This study aims to determine the position of the AC supply which has the best thermal comfort of FAC system in the studio apartment. It can be done by analyzing ADPI (Air Diffusion Performance Index), the distribution of air temperature, wind speed, RH (Relative Humidity), and DR (Draft Risk) to change the position of the AC supply supported by CFD (Computational Fluid Dynamics) simulation.This result prove that AC position 2 (on wall near the kitchen) is more comfortable than AC position 1 (on the bathroom wall) because AC position 2 away from occupied areas, thereby reducing the occurrence of draught discomfort.


2020 ◽  
pp. 014459872096921
Author(s):  
Yanru Li ◽  
Enshen Long ◽  
Lili Zhang ◽  
Xiangyu Dong ◽  
Suo Wang

In the Yangtze River zone of China, the heating operation in buildings is mainly part-time and part-space, which could affect the indoor thermal comfort while making the thermal process of building envelope different. This paper proposed to integrate phase change material (PCM) to building walls to increase the indoor thermal comfort and attenuate the temperature fluctuations during intermittent heating. The aim of this study is to investigate the influence of this kind of composite phase change wall (composite-PCW) on the indoor thermal environment and energy consumption of intermittent heating, and further develop an optimization strategy of intermittent heating operation by using EnergyPlus simulation. Results show that the indoor air temperature of the building with the composite-PCW was 2–3°C higher than the building with the reference wall (normal foamed concrete wall) during the heating-off process. Moreover, the indoor air temperature was higher than 18°C and the mean radiation temperature was above 20°C in the first 1 h after stopping heating. Under the optimized operation condition of turning off the heating device 1 h in advance, the heat release process of the composite-PCW to the indoor environment could maintain the indoor thermal environment within the comfortable range effectively. The composite-PCW could decrease 4.74% of the yearly heating energy consumption compared with the reference wall. The optimization described can provide useful information and guidance for the energy saving of intermittently heated buildings.


Sign in / Sign up

Export Citation Format

Share Document