scholarly journals Indoor Thermal Comfort Analysis: A Case Study of Modern and Traditional Buildings in Hot-Arid Climatic Region of Ethiopia

Urban Science ◽  
2021 ◽  
Vol 5 (3) ◽  
pp. 53
Author(s):  
Haven Hailu ◽  
Eshetu Gelan ◽  
Yared Girma

Indoor thermal comfort is an essential aspect of sustainable architecture and it is critical in maintaining a safe indoor environment. Expectations, acceptability, and preferences of traditional and modern buildings are different in terms of thermal comfort. This study, therefore, attempts to evaluate the indoor thermal comforts of modern and traditional buildings and identify the contributing factors that impede or facilitate indoor thermal comfort in Semera city, Ethiopia. This study employed subjective and objective measurements. The subjective measurement is based on the ASHRAE seven-point thermal sensation scale. An adaptive comfort model was employed according to the ASHRAE standard to evaluate indoor thermal comfort. The results revealed that with regards to thermal sensational votes between −1 and +1, 88% of the respondents are satisfied with the indoor environment in traditional houses, while in modern houses this figure is 22%. Likewise, 83% of occupants in traditional houses expressed a preference for their homes to remain the same or be only slightly cooler or warmer. Traditional houses were, on average, in compliance with the 80% acceptability band of the adaptive comfort standard. The study investigated that traditional building techniques and materials, in combination with consideration of microclimate, were found to play a significant role in regulating the indoor environment.

2021 ◽  
Vol 13 (8) ◽  
pp. 4563
Author(s):  
Nuno Baía Baía Saraiva ◽  
Luisa Dias Dias Pereira ◽  
Adélio Rodrigues Gaspar ◽  
José Joaquim da Costa

The adaptation of spaces to different usage typologies can be complex in heritage buildings. Facilities were initially planned for a specific type of use that, when changed, require additional measures to ensure a suitable indoor environment. Passive strategies—e.g., free cooling—are commonly used as an alternative without requiring equipment installation. However, its implementation often leads to unsatisfactory conditions. Therefore, it is important to clarify the main barriers to achieving thermal comfort in readapted historic buildings. The present work investigates the thermal comfort conditions reported by workers in office spaces of a historic building in the University of Coimbra. A monitoring campaign was carried out between May and September 2020 to assess indoor conditions’ quality. Due to the current pandemic of COVID-19, offices were not occupied at full capacity. A one-day evaluation of thermal comfort was made using a climate analyzer and six occupants were surveyed on 19 August 2020. The main results highlighted discomfort due to overheating of spaces. The causes were related to the combination of inadequate implementation of the free cooling actions and the building use. Furthermore, it was recommended the installation of HVAC systems in case of full capacity.


2020 ◽  
pp. 1420326X2092552
Author(s):  
Yang Zhang ◽  
Wenxuan Yu ◽  
Youli Li ◽  
Han Li

In this article, a comparative study on the outdoor air pollutant prevention and indoor thermal comfort for different types of ventilation was carried out. Both objective experiment, subjective experiment and computational fluid dynamics (CFD) simulation were conducted to investigate the differences in air pollutant prevention and thermal comfort between four common ventilation methods, namely supplying on the ceiling and returning on the ceiling (SC-RC), supplying on the ceiling and returning on the side wall (SC-RSW), supplying on the side wall and returning on the ceiling (SSW-RC), and supplying on the side wall and returning on the side wall (SSW-RSW). Results show that SSW-RSW can provide the highest indoor air quality according to the indoor average PM2.5 concentration. Overall thermal sensation was introduced to evaluate the indoor comfort under the four ventilation methods. The voting results show that the indoor thermal comfort can be enhanced by 29–36% under SSW-RSW and SSW-RC. Therefore, SSW-RSW is more suitable for providing a healthy and comfortable indoor environment.


Energies ◽  
2019 ◽  
Vol 12 (5) ◽  
pp. 808 ◽  
Author(s):  
Hao Tian ◽  
Wei Zhang ◽  
Lingzhi Xie ◽  
Zhichun Ni ◽  
Qingzhu Wei ◽  
...  

Thermal comfort is an important aspect to take into consideration for the indoor environment of a building integrated with a semi-transparent Photovoltaics (STPV) system. The thermal comfort of units with photovoltaic windows and that of conventional windows, which is an ordinary without PV, were evaluated via on-site tests and questionnaires. Using the thermal comfort investigation of the test rig, the maximum difference in air temperature was found to be around 5 °C between test unit and comparison unit. The predicted mean vote (PMV)–predicted percentage dissatisfied (PPD) value of the test unit was better than that of the comparison unit. It was observed that on sunny days, the PMV value ranged from 0.2 (nature) to 1.3 (slightly warm) in the test unit, and that of the comparison unit was 0.7 (slightly warm) to 2.0 (warm), thereby providing better thermal comfort, especially during mornings. The maximum difference in PPD values was found to reach 27% between the two units at noon. On cloudy days, the difference was negligible, and the thermal sensation between the foot and the head were almost the same. Fifty respondents were asked to complete a carefully designed questionnaire. The thermal sensation of the test unit was better than that of comparison unit, which corresponded with the test results. Thermal, lighting, acoustic, and other environment comfort scores were combined, and the acceptance of the test unit with the STPV windows was found to be 73.8%. The thermal sensation difference between men and women was around 5%. Thus, during summer, STPV windows can improve the thermal comfort and potentially reduce the air-conditioning load.


2019 ◽  
Vol 282 ◽  
pp. 02031
Author(s):  
Ricardo M.S.F. Almeida ◽  
Eva Barreira ◽  
Sandra Soares ◽  
Ramos Nuno M.M. ◽  
Sérgio Lopes ◽  
...  

The importance of a good indoor environment for peoples’ health and wellbeing is nowadays clearly established. Besides enhancing the wellbeing of building occupants and helping decrease the occurrence of building related illness, a good indoor environment can also lead to a decrease in worker complaints and absenteeism. This paper presents the results of a three-month monitoring campaign where the thermal comfort of a toll station was evaluated, including the main room and the cabins. The physical parameters required for the assessment of both global and local thermal comfort were measured and the results were compared with the thermal perception of the occupants, which was collected through questionnaires. The indoor environmental quality in the main room was better than in the cabins and a mismatch between the PMV index and the occupants thermal sensation was identified.


2014 ◽  
Vol 525 ◽  
pp. 588-592
Author(s):  
Zhang Yuan Wang ◽  
Xiang Mei Zhang ◽  
Wan Sheng Yang

Aim of the paper is to investigate the indoor thermal comfort of the buildings. This work is undertaken by the combination of the literature review and experimental measurement and analyses, on basis of the selected 12 public buildings in Dongguan City (Guangdong Province, China), located at the typical sub-tropic climatic region. It was found that when the air-conditioning system was turned off, the internal surface temperature of the insulation was above a control target of 30°C; when the air-conditioning system was turned on, the internal surface temperature of the insulation was below the control target of 30°C, meeting the requirement of the thermal comfort of human body in summer. These figures will be helpful in the determination of the quantitative control target to improve the indoor thermal comfort in the subtropical areas.


Author(s):  
Xiao Chen ◽  
Qian Wang

This paper proposes a model predictive controller (MPC) using a data-driven thermal sensation model for indoor thermal comfort and energy optimization. The uniqueness of this empirical thermal sensation model lies in that it uses feedback from occupants (occupant actual votes) to improve the accuracy of model prediction. We evaluated the performance of our controller by comparing it with other MPC controllers developed using the Predicted Mean Vote (PMV) model as thermal comfort index. The simulation results demonstrate that in general our controller achieves a comparable level of energy consumption and comfort while eases the computation demand posed by using the PMV model in the MPC formulation. It is also worth pointing out that since we assume that our controller receives occupant feedback (votes) on thermal comfort, we do not need to monitor the parameters such as relative humidity, air velocity, mean radiant temperature and occupant clothing level changes which are necessary in the computation of PMV index. Furthermore simulations show that in cases where occupants’ actual sensation votes might deviate from the PMV predictions (i.e., a bias associated with PMV), our controller has the potential to outperform the PMV based MPC controller by providing a better indoor thermal comfort.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Subhashini S. ◽  
Thirumaran Kesavaperumal ◽  
Masa Noguchi

Purpose Occupants dwelling in hot climatic regions of India for a longer term are tolerable to high temperature levels than predicted by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) standards. The purpose of this study is to evaluate the thermal sensations (TS) and neutral temperature of the occupants in naturally ventilated (NV) and air-conditioned (AC) classrooms of two technical institutions located in the same premises in the suburbs of Madurai. The main focus of this study is to understand the occupants’ behaviour in response to the thermal conditions of the educational buildings particularly in the warm and humid climatic zone of Madurai. Design/methodology/approach This research collected data through field studies. The data included 383 survey questionnaires from NV classrooms and 285 from AC classrooms, as well as on-site measurements of interior and exterior weather conditions. The TS results show that the students preferred well-designed NV classrooms than AC classrooms. A new adaptive comfort equation derived from this study can be applied to NV classrooms in warm and humid climates where mean outdoor temperature exceeds 40°C. Findings The neutral temperature derived for NV classrooms in Madurai ranged from 29°C to 34°C. Thus, the occupants in the NV classrooms of the higher learning educational institutions in the warm and humid climatic region of Madurai can adapt well to higher indoor temperature levels than predicted by ASHRAE comfort levels with minimum adjustments. Research limitations/implications The study was limited to only occupants in two premier higher learning technical educational institutions located in Madurai region within 5–10 km within the city limits to understand the implications of microclimate with respect to the urban context. Thus, further research is required to examine the tendency under local conditions in other regions beyond those applied to this study. Social implications The findings of this study showed that occupants in higher learning educational intuitions in Madurai prefer NV classrooms than AC classrooms. Therefore, with rising demands of energy use for mechanical ventilation and the associated high cost for running AC buildings, architects should prioritize the design of energy efficient buildings through the optimal use of passive design strategies for ventilation and thermal comfort. This study gives a base data for architects to understand the adaptive limitations of occupants and design NV buildings that can promote natural ventilation and provide better thermal environments that can help increase the productivity of students. Originality/value This paper was an attempt to develop the adaptive comfort model for NV classrooms in Madurai regions. There has been no attempt to identify the adaptive comfort levels of occupants in higher learning technical educational institutions located in warm and humid climatic region of India.


Sign in / Sign up

Export Citation Format

Share Document