scholarly journals An adaptive thermal comfort model for naturally ventilated classrooms of technical institutions in Madurai

2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Subhashini S. ◽  
Thirumaran Kesavaperumal ◽  
Masa Noguchi

Purpose Occupants dwelling in hot climatic regions of India for a longer term are tolerable to high temperature levels than predicted by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) standards. The purpose of this study is to evaluate the thermal sensations (TS) and neutral temperature of the occupants in naturally ventilated (NV) and air-conditioned (AC) classrooms of two technical institutions located in the same premises in the suburbs of Madurai. The main focus of this study is to understand the occupants’ behaviour in response to the thermal conditions of the educational buildings particularly in the warm and humid climatic zone of Madurai. Design/methodology/approach This research collected data through field studies. The data included 383 survey questionnaires from NV classrooms and 285 from AC classrooms, as well as on-site measurements of interior and exterior weather conditions. The TS results show that the students preferred well-designed NV classrooms than AC classrooms. A new adaptive comfort equation derived from this study can be applied to NV classrooms in warm and humid climates where mean outdoor temperature exceeds 40°C. Findings The neutral temperature derived for NV classrooms in Madurai ranged from 29°C to 34°C. Thus, the occupants in the NV classrooms of the higher learning educational institutions in the warm and humid climatic region of Madurai can adapt well to higher indoor temperature levels than predicted by ASHRAE comfort levels with minimum adjustments. Research limitations/implications The study was limited to only occupants in two premier higher learning technical educational institutions located in Madurai region within 5–10 km within the city limits to understand the implications of microclimate with respect to the urban context. Thus, further research is required to examine the tendency under local conditions in other regions beyond those applied to this study. Social implications The findings of this study showed that occupants in higher learning educational intuitions in Madurai prefer NV classrooms than AC classrooms. Therefore, with rising demands of energy use for mechanical ventilation and the associated high cost for running AC buildings, architects should prioritize the design of energy efficient buildings through the optimal use of passive design strategies for ventilation and thermal comfort. This study gives a base data for architects to understand the adaptive limitations of occupants and design NV buildings that can promote natural ventilation and provide better thermal environments that can help increase the productivity of students. Originality/value This paper was an attempt to develop the adaptive comfort model for NV classrooms in Madurai regions. There has been no attempt to identify the adaptive comfort levels of occupants in higher learning technical educational institutions located in warm and humid climatic region of India.

Urban Science ◽  
2021 ◽  
Vol 5 (3) ◽  
pp. 53
Author(s):  
Haven Hailu ◽  
Eshetu Gelan ◽  
Yared Girma

Indoor thermal comfort is an essential aspect of sustainable architecture and it is critical in maintaining a safe indoor environment. Expectations, acceptability, and preferences of traditional and modern buildings are different in terms of thermal comfort. This study, therefore, attempts to evaluate the indoor thermal comforts of modern and traditional buildings and identify the contributing factors that impede or facilitate indoor thermal comfort in Semera city, Ethiopia. This study employed subjective and objective measurements. The subjective measurement is based on the ASHRAE seven-point thermal sensation scale. An adaptive comfort model was employed according to the ASHRAE standard to evaluate indoor thermal comfort. The results revealed that with regards to thermal sensational votes between −1 and +1, 88% of the respondents are satisfied with the indoor environment in traditional houses, while in modern houses this figure is 22%. Likewise, 83% of occupants in traditional houses expressed a preference for their homes to remain the same or be only slightly cooler or warmer. Traditional houses were, on average, in compliance with the 80% acceptability band of the adaptive comfort standard. The study investigated that traditional building techniques and materials, in combination with consideration of microclimate, were found to play a significant role in regulating the indoor environment.


2016 ◽  
Vol 34 (4/5) ◽  
pp. 427-445 ◽  
Author(s):  
Baharuddin Hamzah ◽  
Muhammad Taufik Ishak ◽  
Syarif Beddu ◽  
Mohammad Yoenus Osman

Purpose The purpose of this paper is to analyse thermal comfort and the thermal environment in naturally ventilated classrooms. Specifically, the aims of the study were to identify the thermal environment and thermal comfort of respondents in naturally ventilated university classrooms and compare them with the ASHRAE and Indonesian National Standard (SNI); to check on whether the predicted mean vote (PMV) model is applicable or not for predicting the thermal comfort of occupants in naturally ventilated university classrooms; and to analyse the neutral temperature of occupants in the naturally ventilated university classrooms. Design/methodology/approach The study was carried out at the new campus of Faculty of Engineering, Hasanuddin University, Gowa campus. A number of field surveys, which measured thermal environments, namely, air temperature, mean radiant temperature (MRT), relative humidity, and air velocity, were carried out. The personal activity and clothing properties were also recorded. At the same time, respondents were asked to fill a questionnaire to obtain their thermal sensation votes (TSV) and thermal comfort votes (TCV), thermal preference, and thermal acceptance. A total of 118 respondents participated in the study. Before the survey was conducted, a brief explanation was provided to the participants to ensure that they understood the study objectives and also how to fill in the questionnaires. Findings The results indicated that the surveyed classrooms had higher thermal environments than those specified in the well-known ASHRAE standard and Indonesian National Standard (SNI). However, this condition did not make respondents feel uncomfortable because a large proportion of respondents voted within the comfort zone (+1, 0, and −1). The predictive mean vote using the PMV model was higher than the respondents’ votes either by TSV or by TCV. There was a huge difference between neutral temperature using operative temperature (To) and air temperature (Ta). This difference may have been because of the small value of MRT recorded in the measured classrooms. Originality/value The research shows that the use of the PMV model in predicting thermal comfort in the tropic region might be misleading. This is because PMV mostly overestimates the TSV and TCV of the respondents. People in the tropic region are more tolerant to a higher temperature. On the basis of this finding, there is a need to develop a new thermal comfort model for university classrooms that is particularly optimal for this tropical area.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Ga Yoon Choi ◽  
Hwan Sung Kim ◽  
Hyungkyoo Kim ◽  
Jae Seung Lee

Purpose In cities with high density, heat is often trapped between buildings which increases the frequency and intensity of heat events. Researchers have focused on developing strategies to mitigate the negative impacts of heat in cities. Adopting green infrastructure and cooling pavements are some of the many ways to promote thermal comfort against heat. The purpose of this study is to improve microclimate conditions and thermal comfort levels in high-density living conditions in Seoul, South Korea. Design/methodology/approach This study compares six design alternatives of an apartment complex with different paving and planting systems. It also examines the thermal outcome of the alternatives under normal and extreme heat conditions to suggest strategies to secure acceptable thermal comfort levels for the inhabitants. Each alternative is analyzed using ENVI-met, a software program that simulates microclimate conditions and thermal comfort features based on relationships among buildings, vegetation and pavements. Findings The results indicate that grass paving was more effective than stone paving in lowering air temperature and improving thermal comfort at the near-surface level. Coniferous trees were found to be more effective than broadleaf trees in reducing temperature. Thermal comfort levels were most improved when coniferous trees were planted in paired settings. Practical implications Landscape elements show promise for the improvement of thermal conditions because it is much easier to redesign landscape elements, such as paving or planting, than to change fixed urban elements like buildings and roads. The results identified the potential of landscape design for improving microclimate and thermal comfort in urban residential complexes. Originality/value The results contribute to the literature by examining the effect of tree species and layout on thermal comfort levels, which has been rarely investigated in previous studies.


2020 ◽  
Vol 12 (2) ◽  
pp. 473 ◽  
Author(s):  
Hardi K. Abdullah ◽  
Halil Z. Alibaba

Natural ventilation through window openings is an inexpensive and effective solution to bring fresh air into internal spaces and improve indoor environmental conditions. This study attempts to address the “indoor air quality–thermal comfort” dilemma of naturally ventilated office buildings in the Mediterranean climate through the effective use of early window design. An experimental method of computational modelling and simulation was applied. The assessments of indoor carbon dioxide (CO2) concentration and adaptive thermal comfort were performed using the British/European standard BS EN 15251:2007. The results indicate that when windows were opened, the first-floor zones were subjected to the highest CO2 levels, especially the north-facing window in the winter and the south-facing window in the summer. For a fully glazed wall, a 10% window opening could provide all the office hours inside category I of CO2 concentration. Such an achievement requires full and quarter window openings in the cases of 10% and 25% window-to-floor ratios (WFR), respectively. The findings of the European adaptive comfort showed that less than 50% of office hours appeared in category III with cross-ventilation. The concluding remarks and recommendations are presented.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Hamza Laloui ◽  
Noor Hanita Abdul Majid ◽  
Aliyah Nur Zafirah Sanusi

Purpose This paper aims to investigate the impacts of introducing voids combinations on natural ventilation performance in high-rise residential building living unit. Design/methodology/approach This study was carried out through field measurement and computational fluid dynamics methods. The parameters of the study are void types and sizes, and a wind angle was used to formulate case studies. Findings The results indicate that the provision of a single-sided horizontal void larger by 50% increase the indoor air velocity performance up to 322.37% to 0.471 m/s in the living unit and achieves the required velocity for thermal comfort. Originality/value Passive design features are the most desirable techniques to enhance natural ventilation performance in the high-rise residential apartments for thermal comfort and indoor air quality purposes.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Arnaud Louis Sountong-Noma Ouedraogo ◽  
Adamah Messan ◽  
Daniel Yamegueu ◽  
Yezouma Coulibaly

PurposeA major challenge faced by West Africa is to find comfortable housing as a result of climate change and population growth. The climatic adaptation of buildings and their indoor environment become an essential condition for maintaining the health and productivity of the occupants. This paper proposes a model to assess the thermal comfort of naturally ventilated buildings in hot and dry climates in Burkina Faso.Design/methodology/approachThe proposed method is an adaptive model which relies on a combination of parameters such as the operative temperature, the new effective temperature and the basic parameters of thermal comfort. It consists in proposing the zones of thermal comfort on the diagram of the humid air for each climatic region.FindingsA decision-making tool is set up for evaluating the comfort of buildings to better consider the bio-climatic concept through a long-term comfort index. This comfort index is defined and is used to assess the degree of thermal discomfort for various types of housing. Two natural ventilation pilot buildings located in Ouagadougou were considered. The results show that the pilot building whose wall are is made of Earth blocks achieves 26.4% of thermal comfort while the building made of hollow cement block achieves 25.8% of thermal comfort.Originality/valueThe decision-making tool proposed in the present study allow building stakeholders to better and easily design, assess and improve the thermal environment of buildings.


2018 ◽  
Vol 10 (9) ◽  
pp. 3091 ◽  
Author(s):  
Raúl Castaño-Rosa ◽  
Carlos Rodríguez-Jiménez ◽  
Carlos Rubio-Bellido

The design and construction of buildings is currently subject to a growing set of requirements concerning sustainability and energy efficiency. This paper shows a case study of the Torre Sevilla skyscraper, located in the city of Seville (in the south of Spain), which has high-tech energy-efficient features and which uses air-conditioning systems during most of its operating hours. The analysis carried out starts from a simulation in which occupants’ thermal comfort are obtained, based on the adaptive comfort model defined in the standard EN 15251:2007. With this approach, it is possible to determine the number of hours during operation in which the building has adequate comfort conditions only with the help of the envelope and natural ventilation. Consequently, the remaining useful hours require the use of air-conditioning systems. The results show that it is possible to improve the thermal performance of the building due to its location in the Mediterranean climate. To do this, advanced mixed mode (through manual-opening or mechanically-controlled opening windows) and active air-conditioning are suggested. This experimental proposal provides a reduction of the occupation hours which require the use of air-conditioning equipment by 28.57%, reducing the air-conditioning demand and, consequently, the energy consumption of the building.


Energies ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 5388
Author(s):  
Hao Sun ◽  
Carlos Jimenez-Bescos ◽  
Murtaza Mohammadi ◽  
Fangliang Zhong ◽  
John Kaiser Calautit

Natural ventilation is an energy-efficient way to provide fresh air and enhance indoor comfort levels. The wind-driven natural ventilation in courtyards has been investigated by many researchers, particularly the influence of the spatial configuration and environmental parameters on the ventilation and thermal comfort performance. However, previous research has mainly focused on the courtyard region instead of the indoor spaces surrounding it. Additionally, as a microclimate regulator, courtyards are rarely assessed in terms of the impact of vegetation, including its impact on energy consumption and thermal comfort. Evapotranspiration from vegetation can help lower air temperature in the surrounding environment and, therefore, its influence on the ventilation and thermal comfort in buildings with courtyards should be evaluated. The present study investigates the impact of vegetation on the aero-thermal comfort conditions in a courtyard and surrounding buildings in hot climates. Computational fluid dynamics was employed to evaluate the aero-thermal comfort conditions of the courtyard and surrounding buildings with different configurations of vegetation. The modeling was validated using previous works’ experimental data, and good agreement was observed. Thermal comfort indices were used to assess thermal performance. The study also evaluated the cover, height and planting area of vegetation in the courtyard. The results of this study can help develop tools that can assist the addition of vegetation in courtyards to maximize their effects. Future works will focus on looking at the influence of the strategies on different designs and layouts of courtyards.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Zul-Atfi Bin Ismail

PurposeImproper evaluation and information mismanagement concerning thermal comfort appears to negatively affect occupants' satisfaction and building energy consumption in precast concrete (PC) building contexts. Predictive models are particularly problematic in PC building construction projects where natural ventilation levels do not coincide with occupants' thermal comfort and thermal sensation specifications.Design/methodology/approachA systematic literature review is undertaken to explore the viability and benefits of a new ICT-based approach for meeting social and environmental objectives.FindingsSophisticated thermal comfort system solutions are essential for optimising thermal comfort and saving energy in PC building construction projects.Originality/valueIt is imperative that designers and manufacturers are kept up-to-date with the possibilities and potentials associated with new and nascent technologies so that building projects can meet key sustainability criteria.


Sign in / Sign up

Export Citation Format

Share Document