scholarly journals Effect of Aeration Modes and COD/N Ratios on Organic Matter and Nitrogen Removal in Horizontal Subsurface Flow Constructed Wetland Mesocosms

Water ◽  
2018 ◽  
Vol 10 (11) ◽  
pp. 1530 ◽  
Author(s):  
Xin Chen ◽  
Hui Zhu ◽  
Yingying Xu ◽  
Brian Shutes ◽  
Baixing Yan ◽  
...  

A series of mesocosm-scale horizontal subsurface flow constructed wetlands (HSSF-CWs) were established. In Experiment 1, four artificial aeration (AA) modes, including pre-aeration at 24 h before the input of influent water (PA), aeration at 6 h (6AA) and 12 h (12AA) after the input of influent water and non-aeration (NA), were tested to obtain an optimal aeration mode for chemical oxygen demand (CODCr) and nitrogen removal. The results showed that aeration after the input of influent water could improve the removal efficiencies of CODCr and ammonia-nitrogen (NH4⁺-N), but lead to an accumulation of nitrate-nitrogen (NO3−-N). The above observation demonstrated that a single aeration cannot create an ideal alternation of aerobic and anaerobic conditions for simultaneous nitrification and denitrification. Therefore, HSSF-CWs with intermittent aeration (IA), after the input of influent water and NA were established to evaluate the combined effects of IA and influent COD/N ratios on pollutant removal in Experiment 2. The HSSF-CW with IA exhibited a better performance in CODCr and nitrogen removal compared to HSSF-CW with NA. The highest removal percentages of CODCr (90.1%), NH4+-N (99.8%) and total nitrogen (TN, 99.5%) were achieved at a COD/N ratio of 9.3 in HSSF-CW with IA.

2020 ◽  
Vol 20 (8) ◽  
pp. 3318-3329
Author(s):  
Fernanda Lamede Ferreira de Jesus ◽  
Antonio Teixeira de Matos ◽  
Mateus Pimentel de Matos

Abstract The objective of this study was to evaluate the influence of stoloniferous and fasciculated root systems, of Tifton 85 and vetiver grass respectively, on pollutant removal for primary treatment of sewage in horizontal subsurface flow constructed wetlands (HSSF-CWs). For this, three HSSF-CWs measuring 4 m × 1 m × 0.25 m, filling with gneiss gravel # 0 (D60 of 7.0 mm and 48.4% porosity) as substrate, were used. One unit was cultivated with Tifton 85 grass (HSSFT-CW), one with vetiver grass (HSSFV-CW) and one remained uncultivated (HSSFC-CW) as a control. Sewage was applied at a flow rate of 0.53–0.80 m3 d−1, corresponding to an organic loading rate of approximately 350 kg ha−1 d−1 (biochemical oxygen demand – BOD), which resulted in a hydraulic retention time of 0.6–0.9 day. The HSSFV-CW was more efficient than the HSSFC-CW in removing dissolved solids (measured as electrical conductivity) and reducing the total suspended solids (TSS), BOD5, turbidity and sodium concentration, while the HSSFT-CW was not superior in any way. The results indicate that cultivation of vetiver grass provided increased efficiency for removing pollutants from sewage when compared with Tifton 85-grass, in the HSSF-CW.


2011 ◽  
Vol 64 (11) ◽  
pp. 2177-2184 ◽  
Author(s):  
J. Zhai ◽  
H. W. Xiao ◽  
K. Kujawa-Roeleveld ◽  
Q. He ◽  
S. M. Kerstens

A new type of hybrid constructed wetland (CW), consisting of both vertical-baffled flow wetland (VBFW) and horizontal subsurface flow wetland (HSFW), has been deployed in Southern China to naturally accelerate the removal of organic matter and nitrogen. The hybrid CW system is characterised by a combination of continuous baffled flow vertical wetland and ‘S’ pattern horizontal subsurface flow wetland with natural aeration ditches to increase the concentration of dissolved oxygen in the HSFW bed. An internal circulatory system from the HSFW effluent back to the VBFW may optionally be operated to enhance the biological denitrification effect. Cyperus alternifolius is the main macrophyte in the wetland bed. The performance of the hybrid CW was studied with a pilot-scale system and three full-scale systems for municipal sewage treatment in Southern China. The results suggest that this new hybrid CW can achieve removal efficiencies of chemical oxygen demand, suspended solids, ammonia nitrogen, total nitrogen, and total phosphorus of better than 83.6, 95.0, 71.7, 64.5 and 68.1% respectively, with a specific wetland bed area of 0.70–0.93 m2 PE−1. The mean effluent concentrations of these parameters would meet the regulatory discharge limits for wastewater treatment systems (GB18918, 2002) and reuse in the context of agricultural irrigation solutions in China.


2020 ◽  
Vol 12 (12) ◽  
pp. 5102
Author(s):  
José Alberto Herrera-Melián ◽  
Mónica Mendoza-Aguiar ◽  
Rayco Guedes-Alonso ◽  
Pilar García-Jiménez ◽  
Marina Carrasco-Acosta ◽  
...  

In this study, pilot-scale hybrid constructed wetlands (CWs) and multistage horizontal subsurface flow CWs (HF CWs) have been studied and compared for the treatment of raw urban wastewater. In the hybrid CWs, the first stage was a mulch-based horizontal subsurface flow CW and the second stage was a vertical subsurface flow CW (VF CW). The VF CWs were used to determine if sand could improve the performance of the hybrid CW with respect to the mulch. In the multistage HFs, mulch, gravel and sand were used as substrates. The effect of water height (HF10: 10 cm vs. HF40: 40 cm) and surface loading rate (SLR: 12 vs. 24 g Chemical Oxygen Demand (COD)/m2d) has been studied. The results show that the use of sand in the vertical flow stage of the hybrid CW did not improve the average performance. Additionally, the sand became clogged, while the mulch did not. The effect of water height on average pollutant removal was not determined but HF10 performed better regarding compliance with legal regulations. With a SLR of 12 g COD/m2d, removals of HF10 were: 79% for COD, 75% for NH4+-N, 53% for dissolved molybdate-reactive phosphate-P (DRP), 99% for turbidity and 99.998% for E. coli and total coliforms. When SLR was doubled, removals decreased for NH4+-N: 49%, DRP: −20%, E coli and total coliforms: 99.5–99.9%, but not for COD (85%) and turbidity (99%). Considering the obtained results and the simplicity of the construction and operation of HFs, HF10 would be the most suitable choice for the treatment of raw urban wastewater without clogging problems.


2019 ◽  
Vol 20 (2) ◽  
pp. 33-40
Author(s):  
Muna A. Rahi ◽  
Ayad A. H. Faisal

This study aimed at comparing the performance of vertical, horizontal and hybrid subsurface flow systems in secondary treatment for the effluent wastewater from the primary basins at Al-Rustumia wastewater treatment plant, Baghdad, Iraq. The treatments were monitored for six weeks while the testsduration were from 4 to 12 September 2018 under continuous wastewater feeding for chemical oxygen demand (COD), total suspended solid (TSS),ammonia-nitrogen(NH4-N) and phosphate (PO4-P) in comparison with FAO and USEPA standards for effluent discharge to evaluate the suitability of treated water for irrigation purposes. Among the systems planted with Phragmites Australia, the hybrid subsurface flow system which consisted of vertical unit followed by horizontal one, considerably removed the pollutants more efficiently than the single operated systems. The planted hybrid subsurface flow wetland system was achieved the highest removal with a mean removal rate of COD,TSS, NH4-N, and PO4-Pat 99.3, 83.2,67.4 and 53% respectively and these percentages were decreased in the other systems. The results proved that the planted vertical subsurface flow unit can be removed the COD, TSS, NH4-N and PO4-Pwith values of 93, 71.1, 43.3 and 30.7%, respectively while the achieved removals by horizontal subsurface flow unit of 99, 74.3, 54.5 and 20.3%, respectively. The planted horizontal subsurface flow wetland, however, showed a good efficacy for all parameters in the treatment process except for PO4-P when it is compared with vertical system, however, there is a clear increase in the NO3-N effluent concentration for all treatment units.


Author(s):  
R. Shruthi ◽  
G. P. Shivashankara

Abstract To find the effect of Hydraulic Retention Time (HRT) and seasons on the performance of horizontal subsurface flow constructed wetland (HSSF CW) in treating rural wastewater, a pilot scale unit 2.5 m × 0.4 m × 0.3 m size bed planted with a Typha latifolia and Phragmites australis was operated for a 12-month duration. During the study 2, 4, 6, 8, and 10 days of HRT were maintained in winter, summer, and rainy seasons. The removal efficiency obtained was ranges from 62.09 to 87.23% for Chemical Oxygen Demand, 69.58% to 93.32% for Biochemical Oxygen Demand5 (BOD), 31.55% to 59.89% for Ammonia Nitrogen (NH4-N), 15.18% to 52.90% for Total Kjeldahl Nitrogen (TKN), 21.02% to 50.21% for Phosphate Phosphorus (PO43− P), 19.82% to 48.23% for, Total phosphorus (TP), 74.93% to 93.10% for Faecal Coliform (FC) and 69.93% to 90.23% Total Coliform (TC). Overall, results showed that the performance of the unit was good. For statistical analysis two way ANOVA test followed by the Tukey test was used with a 95% level of significance. It was observed that the removal efficiency of the pollutants were increased with an increase in HRT. HRT of 6 days found as adequate for significant removal of organic matter (COD and BOD). Seasonal removal efficiencies followed the order of summer > rainy > winter for all the parameters, but the difference was not statistically significant.


2017 ◽  
Vol 77 (4) ◽  
pp. 988-998 ◽  
Author(s):  
Tadesse Alemu ◽  
Andualem Mekonnen ◽  
Seyoum Leta

Abstract In the present study, a pilot scale horizontal subsurface flow constructed wetland (CW) system planted with Phragmites karka; longitudinal profile was studied. The wetland was fed with tannery wastewater, pretreated in a two-stage anaerobic digester followed by a sequence batch reactor. Samples from each CW were taken and analyzed using standard methods. The removal efficiency of the CW system in terms of biological oxygen demand (BOD), chemical oxygen demand (COD), Cr and total coliforms were 91.3%, 90%, 97.3% and 99%, respectively. The removal efficiency for TN, NO3− and NH4+-N were 77.7%, 66.3% and 67.7%, respectively. Similarly, the removal efficiency of SO42−, S2− and total suspended solids (TSS) were 71.8%, 88.7% and 81.2%, respectively. The concentration of COD, BOD, TN, NO3−N, NH4+-N, SO42 and S2− in the final treated effluent were 113.2 ± 52, 56 ± 18, 49.3 ± 13, 22.75 ± 20, 17.1 ± 6.75, 88 ± 120 and 0.4 ± 0.44 mg/L, respectively. Pollutants removal was decreased in the first 12 m and increased along the CW cells. P. karka development in the first cell of CW was poor, small in size and experiencing chlorosis, but clogging was higher in this area due to high organic matter settling, causing a partial surface flow. The performance of the pilot CW as a tertiary treatment showed that the effluent meets the permissible discharge standards.


1994 ◽  
Vol 30 (12) ◽  
pp. 297-306 ◽  
Author(s):  
Joseph Akunna ◽  
Claude Bizeau ◽  
René Moletta ◽  
Nicolas Bernet ◽  
Alain Héduit

Two laboratory upflow aerobic and anaerobic filters fed with synthetic wastewaters were used to study firstly the effects of aeration rate on the nitrification of anaerobically pre-treated effluents and secondly the effects of recycle-to-influent ratios on methane production rate, denitrification and nitrification performances of a combined aerobic and anaerobic wastewater treatment process. Nitrification of anaerobically pre-treated effluent was accompanied by aerobic post-treatment for residual COD removal. A comparison of nitrification performances using autotrophic medium and anaerobically pre-treated effluents (containing 1203 mg COD 1−1) with the same ammonia nitrogen concentration of about 300 mg NH4-N 1−1 showed that 3% of added ammonia nitrogen was assimilated by autotrophic nitrifiers during nitrification of the autotrophic medium while up to 30% was assimilated by both nitrifiers and heterotrophs during organic carbon removal and nitrification of anaerobically pre-treated effluent. Furthermore, it was suspected that significant nitrogen loss through denitrification occured in the aerobic filter especially at low aeration rates. In the study of the combined aerobic-anaerobic system, maximum ammonia nitrogen removal of 70% through denitrification was obtained at recycle-to-influent ratios of 4 and 5. COD removal efficiency in the anaerobic filter decreased from 77 to 60% for recycle-to-influent ratios of zero to 5. Overall COD removal efficiency of the entire system was constant at about 99% due to heterotrophic COD removal in the aerobic filter.