scholarly journals Analisis Kontribusi Limbah Domestik Terhadap Kualitas Air Sungai Tondano-Sawangan Sulawesi Utara

2020 ◽  
Vol 1 (2) ◽  
pp. 6
Author(s):  
Norinca Sagala ◽  
Maxi Tendean ◽  
Helena Sri Sulastriningsih

Masalah penelitian ini adalah kontribusi limbah domestik terhadap kualitas air sungai Tondano-Sawangan Sulawesi Utara.  Penelitian ini bertujuan untuk mengkaji tentang kontribusi limbah domestik penduduk di bantaran sungai Sawangan terhadap kualitas air sungai Tondano-Sawangan Sulawesi Utara. Metode penelitian yang digunakan adalah deskriptif kuantitaf. Teknik pengumpulan data dikumpulkan dari hasil pengambilan sampel di dua lokasi dan perhitungan labolatorium dan dokumentasi yang ada dilapangan. Parameter yang diukur di laboratorium adalah derajat keasaman atau pH, Biochemilcal Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solid (TSS), Amoniak, dan Total Coliform.  Hasil penelitian menunjukkan kualitas air Sungai Tondano-Sawangan mengalami penurunan kualitas dari hulu ke hilir yang disebabkan oleh limbah domestik penduduk. Parameter yang dominan memberikan kontribusi nilai indeks pencemar yang tinggi adalah parameter biologi yaitu total coliform. Pencemaran air yang disebabkan oleh kontaminasi limbah toilet merupakan masalah yang cukup serius, dikarenakan adanya potensi penularan penyakit oleh pathogen. Kandungan Total coliform yang terdapat pada air sungai bagian hulu sebesar 24200 MPN/100ml sedangkan bagian hilir sebesar 19900 MPN/100ml, sudah melebihi nilai ambang batas standar baku mutu sesuai Standar Nasional Indonesia. Batas maksimum Cemaran Total Coliform yaitu 3000 MPN/100ml, dengan demikian dapat dikatakan bahwa mutu air sungai Sawangan sudah tidak aman lagi untuk di konsumsi bagi masyarakat, namun untuk kegiatan rekreasi, tambak ikan, dan lain sebagainya masih aman. Parameter lain seperti BOD, COD, pH, TSS, Amonia, masih aman karena berada dibawah standar Baku Mutu.Kata Kunci: Limbah Domestik , Kualitas Air, Pencemaran Air, Baku Mutu

2020 ◽  
Vol 5 (2) ◽  
pp. 120
Author(s):  
Muhammad Tri Aji ◽  
Abdul Qadir Jailani

Era milenial ini permasalahan air sebagai sumber kehidupan semakin terasa. Terutama pada air tanah yang menjadi salah satu sumber kehidupan sehari – hari mulai dari aktifitas rumah tangga sampai aktifitas industri. Permasalahan air tanah semakin terasa apabila diiringi dengan laju pertumbuhan penduduk yang semakin tinggi. Kota Magelang merupakan salah satu kota yang perkembangannya tergolong pesat di wilayah Provinsi Jawa Tengah. Hal ini dapat dilihat dari pembangunan serta pertumbuhan ekonomi yang dicapai oleh kota ini. Penelitian ini bertujuan untuk mengetahui kondisi terkini mengenai kualitas air tanah di wilayah kota magelang akibat pembuangan limbah domestik dan industri dengan menganalisis parameter fisika (Suhu), parameter kimia (pH, Nitrat, BOD, COD, dan TSS), dan parameter biologi (Total Coliform). Penetapan lokasi penelitian guna pengambilan sampling air dilakukan menggunakan metode purposive sampling. Analisa parameter kualitas air dapat dilakukan secara in situ dan ex-situ serta nantinya akan di bandingkan dengan baku mutu air PP No.82 tahun 2001 dan Permenkes No. 32 tahun 2017. Hasil penelitian menunjukkan bahwa untuk parameter fisika masih dalam kondisi yang baik dengan nilai suhu rata-rata 26,1°C, sedangkan untuk nilai TSS (Total Suspended Solid) dan TDS (Total Dissolved Solid) 3,7 mg/L dan 227,95 mg/L. sedangkan untuk parameter kimia pH menunjukkan nilai yang cukup fluktuatif dan pada beberapa stasiun air tanah bersifat asam dengan nilai dibawah 7. Nilai nitrat pada stasiun penelitian 1,6,7 dan 9 memiliki nilai melebihi ambang batas yang ditetapkan yaitu 10 mg/L. Kemudian untuk nilai BOD (Biological Oxygen Demand) memiliki nilai lebih dari 2 mg/L sebagai syarat masuk kelas 1 mutu air tanah yang aman untuk higine, COD (Chemical Oxygen Demand) mempunyai nilai yang melebihi syarat maksimal yaitu 10 mg/L di semua stasiun penelitian, oleh sebab itu dikatagorikan sebagai pencemaran berat. Nilai total coliform yang melebihi baku mutu air untuk keperluan higiene sanitasi menurut Permenkes No. 32 tahun 2017 sebesar 50 MPN/100ml.kualitas air tanah Kota Magelang dapat dimanfaatkan untuk keperluan air minum dengan catatan penggunannya harus melalui proses pemasakan terlebih dahulu.


Jurnal Ecolab ◽  
2021 ◽  
Vol 15 (2) ◽  
pp. 101-109
Author(s):  
Dewi Ratnaningsih ◽  
◽  
Retno Puji Lestari ◽  
Ernawita Nazir

Kualitas air di suatu wilayah yang merupakan salah satu indikator lingkungan dapat dievaluasi menggunakan parameter fisika, kimia, dan biologi. Indeks Kualitas Air Indonesia (IKA-INA) dapat digunakan untuk menilai kondisi kualitas air secara menyeluruh pada lokasi dan waktu tertentu. IKA-INA dihitung dengan menggunakan sepuluh (10) parameter yaitu pH, Total Dissolved Solid (TDS), Total Suspended Solid (TSS), Dissolved Oxygen (DO), Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), NO3, NH3, Total Phosphate (TP) dan fecal coliform. IKA-INA tersebut merupakan indeks kualitas air yang dapat memberikan informasi secara sederhana. Dalam pemanfaatannya, tidak semua data parameter dalam IKA-INA tersebut dapat terpenuhi karena adanya data tidak valid atau data yang hilang. Kajian ini bertujuan untuk memberi alternatif rumusan IKA-INA dengan parameter yang tidak lengkap atau jika tidak semua data dalam parameters tersebut tersedia. Metode yang digunakan dalam menyusun rumusan adalah dengan melakukan koreksi faktor bobot parameter IKA-INA terhadap parameter yang hilang dan nilai Q (nilai sub-indeks). Setelah itu dilakukan uji coba pada nilai baku mutu air dalam Peraturan Pemerintah No. 22/2021 Lampiran VI serta pada data kualitas air sungai yang mewakili kualitas baik dan buruk. Hasil uji coba menunjukkan bahwa bobot parameter terkoreksi dapat digunakan untuk penanganan parameter yang hilang dalam penilaian kualitas air dengan metode IKA-INA. Hasil IKA-INA dengan parameter hilang yang menggunakan bobot terkoreksi dan hasil IKA-INA dengan parameter lengkap mayoritas memberikan status IKA yang tidak berbeda, kecuali untuk parameter fecal coli dan parameter yang mempunyai kadar jauh berbeda terhadap kondisi air secara keseluruhan.


2014 ◽  
Vol 11 (2) ◽  
pp. 62 ◽  
Author(s):  
M Wawan Kurniawan ◽  
P Purwanto ◽  
S Sudarno

ABSTRAKIndustri batik menimbulkan dampak air limbah organik dalam jumlah yang besar, warnayang pekat, berbau menyengat dan memiliki suhu, keasaman (pH), Biochemical OxygenDemand (BOD), Chemical Oxygen Demand (COD) serta Total Suspended Solid (TSS) yangtinggi. Desa Banaran Kecamatan Grogol Kabupaten Sukoharjo merupakan sentra industriusaha mikro, kecil dan menengah (UMKM) batik yang potensial dalam mendukungperekonomian lokal namun belum memiliki sistem pengelolaan air limbah. Penelitian inibertujuan untuk menyusun strategi pengelolaan air limbah UMKM Batik di Desa Banarandalam perspektif good governance berdasarkan kajian aspek teknis, aspek ekonomi, aspekmanajemen dan aspek sosial dengan menggunakan analisis SWOT (Strength, Weakness,Opportunity and Threats) dilanjutkan penentuan prioritas strategi dengan metode AHP(Analytical Hierarchy Process). Untuk mengkaji keempat aspek tersebut maka dilakukanobservasi, dokumentasi, pengukuran, uji laboratorium di lokasi penelitian dan wawancaraterhadap stakeholders dalam pengelolaan air limbah UMKM Batik di Desa Banaran yaitupemerintah daerah, UMKM Batik, tokoh masyarakat dan sektor swasta pelaku CorporateSocial Responsibility (CSR) di Kabupaten Sukoharjo. Berdasarkan hasil analisis SWOT danmetode AHP menghasilkan prioritas strategi untuk mewujudkan pengelolaan air limbahUMKM Batik yaitu : (1) Aspek Manajemen : penyusunan kebijakan dan programpengelolaan air limbah UMKM Batik, (2) Aspek Teknis : penentuan lahan untuk InstalasiPengolahan Air Limbah (IPAL) yang representatif, (3) Aspek Ekonomi : swadana UMKMBatik dalam operasional dan perawatan IPAL dan (4) Aspek Sosial : pembinaan tekniskepada UMKM Batik dalam pengelolaan air limbah. Untuk mewujudkan pengelolaan airlimbah UMKM Batik secara optimal dan berkelanjutan diperlukan kerjasama dankemitraan yang baik di antara stakeholders sebagai perwujudan dari paradigma goodgovernance didalam kerangka pembangunan yang berkelanjutan.Kata kunci : pengelolaan air limbah UMKM batik, good governance, prioritas strategi


REAKTOR ◽  
2014 ◽  
Vol 15 (2) ◽  
pp. 73 ◽  
Author(s):  
Lieke Riadi ◽  
Whenny Ferydhiwati ◽  
Liok Dimas Sanjaya Loeman

Limbah industri tekstil di area pinggir kota Surabaya mempunyai karakteristik perbandingan COD dan BOD = 5.57. Limbah jenis ini sulit untuk dibiodegradasi. Studi ini mempelajari tekonologi elektrokoagulasi untuk mengolah limbah tekstil dengan menurunkan intensitas warna, Total Suspended Solid (TSS) dan Chemical Oxygen Demand (COD). Percobaan batch pada suhu kamar dilakukan untuk mempelajari pengaruh pH, jarak elektroda terhadap penurunan warna,TSS dan COD dan membandingkan biaya operasinya jika menggunakan pengolahan kimia.Effisiensi penurunan tertinggi untuk warna (91.96%),  TSS (49.17%), dan COD (29.67%) terjadi pada pH awal 4.0 dan jarak elektroda 2 cm dengan  elektroda Al/Al. Waktu optimum penurunan intensitas warna dalah 10 menit. Laju penurunan COD adalah : -dC/dt = 0.0053 C +0.056 , dengan C adalah konsentrasi COD. Jumlah sludge yang dihasilkan daripengolahan elektrokoagulasi  3.4 % lebih kecil dibandingkan menggunakan bahan kimia. Biaya yang digunakan untuk pengolahan dengan elektrokoagulasi 52.35 % lebih murah dibandingkan jika menggunakan koagulasi dengan bahan kimia ( tawas). Kata kunci : elektrokoagulasi, penurunan warna, penurunan TSS, laju degradasi COD, imbah tekstil Abstract Waste water from textile industry which is located in one suburb of Surabaya city as characteristic which the ratio of COD to BOD was 5.57. This type of waste water is difficult to be biodegraded. This study investigated elektrokoagulasi technology to treat textile waste water by removing color, total suspended solid, and Chemical Oxygen Demand. Batch experiment at room temperature was carried out to study the effect of pH, electrode distance for color, TSS and COD removal. This study also tried to compare the operation cost between elektrokoagulasi and chemical processes. The best removal efficiencies by Al electrodes was 91.96 % for color, 49.17 % for TSS and 29.67 % for COD which were under initial pH 4.0 and electrodes distance 2 cm. The optimum operation time for color removal was  found 10 minutes.The COD degradation rate was - dC/dt = 0.0053 C +0.056, with C= COD concentration. Sludge result from elektrokoagulasi was 3.4 % less than that by chemical treatment.The operation cost for elektrokoagulasi is 52.35 % less than that for chemical coagulation. 


2017 ◽  
Vol 15 (1) ◽  
pp. 61-69
Author(s):  
Uswatun Hasanah ◽  
Sugito Sugito

Tingginya kandungan zat organik pada limbah cair industri rumah potong ayam (RPA) menyebabkan limbah cair tersebut tidak boleh dibuang langsung ke lingkungan akuatik. Peningkatan kebutuhan protein dari sumber konsumsi daging ayam, menyebabkan peningkatan limbah cair industri RPA. Oleh karena itu diperlukan suatu alternatif penyelesaian untuk menurunkan kandungan beban pencemar pada limbah cair industri RPA agar kualitas effluent yang dihasilkan tidak mencemari lingkungan serta memenuhi baku mutu yang telah ditetapkan. Pada penelitian ini pengolahan limbah cair RPA dilakukan dengan menggunakan sistem biofilter anaerob media bioball, dengan variasi waktu tinggal dan konsentrasi influnt. Sampel  pengukuran konsentrasi Chemical Oxygen Demand (COD) influent berturut turut sebesar 734 mg/L, 388 mg/L, dan 248 mg/L. Konsentrasi Total Suspended Solid (TSS) dalam air baku limbah RPA sebesar 88 mg/L, 70 mg/L, dan 54 mg/L. Setelah dilakukan pengolahan mengalami penurunan konsentrasi COD dan TSS terhadap semua variasi konsentrasi. Waktu tinggal yang paling efektif dalam menurunkan kadar COD dan TSS pada limbah cair RPA adalah 7 jam.


2021 ◽  
Vol 25 (1) ◽  
pp. 30
Author(s):  
Kadek Diana Harmayani

The Mangusada Regional General Hospital (RSD) as a provider of health facilities certainly produces liquid waste in every operational activity. Wastewater in the Wastewater Treatment Installation (WWTI) RSD Mangusada contains Biological Oxygen Demand (BOD5), Chemical Oxygen Demand (COD), Total Suspended Solid (TSS), ammonia, total coliform, Total Dissolved Solid (TDS), detergent, oil and fat. This study aims to evaluate the performance of the WWTI as well as to determine the content in the wastewater after being treated by the IPAL RSD Mangusada according to the reference quality standards of the Governor of Bali Regulation No.16/2016 and Regulation of the Minister of Environment and Forestry of the Republic of Indonesia Number: P.68/Menlhk/Setjen/Kum.1/8/2016. The wastewater treatment system at RSD Mangusada uses a biological system. The data used in the analysis are secondary data, namely the Bed Occupation Rate (BOR) data in June 2020, the total number of beds, the average discharge of outlets in June 2020 and parameters of the quality and quantity of wastewater in the inlet and outlet of WWTI from January 2020 to July 2020. Based on the results of testing the quality and quantity of wastewater at the WWTI of RSD Mangusada outlet, the content of waste water in the outlet of WWTI is in accordance with the regulatory standards for the reference quality standards. In addition, the effectiveness of the efficiency of the WWTI at RSD Mangusada succeeded in reducing the ammonia content of 92.35%, BOD5 64.03%, COD 63.97%, TSS 67.03%, oil and fat 64.64%, total coliform 76.84%. , and detergent at 76.25%. But the efficiency of the WWTI of RSD Mangusada was not good enough in reducing the TDS content of -3.92%.  


2018 ◽  
Author(s):  
Indra Agus Riyanto ◽  
M Widyastuti ◽  
Heru Hendrayana

Sub DAS (Daerah Aliran Sungai) Serayu terletak di Kabupaten Wonosobo JawaTengah dengan luasan 13682.19 ha. Sub DAS Serayu merupakan salah satu Sub DAS yangmemiliki peranan penting terhadap kondisi DAS Serayu, yaitu sebagai daerah imbuhan air.Pada saat ini, di bagian hulu Sub DAS Serayu telah dimanfaatkan secara intensif untukpertanian dan Wisata Kawasan Dieng sehingga memberikan pengaruh terhadap kuantitasdan kualitas air sungai, serta kondisi DAS. Tujuan penelitian ini adalah menganalisisbesarnya debit aliran Sub DAS Serayu, menganalisis kualitas air sungai Sub Das Serayu,dan menganalisis tingkat kekritisan Sub DAS Serayu. Besarnya debit aliran dihitungmenggunakan pendekatan neraca air metode Thornthwaite Mather dan divalidasi denganpengukuran lapangan. Kualitas air diukur langsung di lapangan dan di laboratorium.Pengukuran langsung meliputi suhu, daya hantar listrik (DHL) dan pH; sedangkanpengukuran di laboratorium meliputi Dissolved Oxygen (DO), Biochemical OxygenDemand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solid (TSS), TotalDissolved Solid (TDS), nitrat, fosfat, sulfat, amonia, H2S, Fe, Mn, detergen, coli tinja, danminyak lemak. Kekritisan Sub DAS didekati dengan perbandingan besarnya debit alirandan kebutuhan air dalam Sub DAS. Hasil penelitian menunjukkan bahwa neraca air SubDAS Serayu probabilitas 60 % diperoleh Direct runoff (DRO) sebesar 274.659.736m3/tahun, sedangkan probabilitas 80 % diperoleh DRO sebesar 182.487.225 m3/tahun.Validasi hasil perhitungan debit neraca air diperoleh 15% lebih tinggi dari debitpengukuran. Parameter kualitas air yang melebihi ambang batas baku mutu kelas IImenurut Peraturan Pemerintah 82/2001 adalah coli tinja pada seluruh sampel; dan padabeberapa sampel untuk kadar Fe, detergen, minyak lemak, sulfida dan pospat hal tersebutdisebabkan oleh keterdapatan penggunaan lahan berupa pertanian intesif di wilayah huludiikuti kegiatan wisata, dominasi sawah di bagian tengah Sub DAS, serta dominanpermukiman di hilir Sub DAS. Hasil analisis kekritisan Sub DAS Serayu menunjukkanbahwa kondisi Sub DAS termasuk klasifikasi tidak kritis.


2012 ◽  
Vol 15 (2) ◽  
pp. 62-69
Author(s):  
Galih Widayanti ◽  
Didik Setiyo Widodo ◽  
Abdul Haris

Telah dilakukan elektrodekolorisasi air yang tercemar limbah industri Batik dan Tekstil di daerah Batang dan Pekalongan. Penelitian ini bertujuan untuk mendekolorisasi zat warna dalam air limbah industri batik dan tekstil dengan pendekatan elektrolisis menggunakan elektroda PbO2/Pb dan mengukur parameter pH, COD (Chemical Oxygen Demand), TSS (Total Suspended Solid), TDS (Total Disolved Solid). Penelitian dilakukan melalui elektrolisis 100 mL limbah air sungai Pekalongan dan Batang pada potensial 6,5 volt dan 8,0 volt untuk limbah sebelum di buang ke sungai. Waktu elektrolisis selama 200 menit. Hasil akhir elektrolisis dianalisis dengan Spektrometer UV-Vis dan analisis parameter pH, COD, TDS dan TSS sebelum dan sesudah proses elektrolisis. Hasil yang di dapatkan sebagai berikut: sebelum elektrolisis limbah air sungai di Pekalongan pH 6,90; COD 54,20 mg/L; TSS 20,30 mg/L; TDS 1,893 mg/L. Limbah air sungai di Batang pH 6,71; COD 56,18 mg/L; TSS 25,55 mg/L; TDS 7,393 mg/L. Limbah sebelum di buang ke sungai pH 7,32; COD 678,32 mg/L; TSS 219,15 mg/L; TDS 1,983 mg/L. Sesudah elektrolisis limbah air sungai di Pekalongan pH 6,99; COD 52,10 mg/L; TSS 2,03 mg/L; TDS 1,925 mg/L. Limbah air sungai di Batang pH 7,99; COD 69,903 mg/L; TSS10,70 mg/L; TDS 6,785 mg/ L. Limbah sebelum di buang ke sungai pH 7,56; COD 366,830 mg/L; TSS 46,50 mg/L; TDS2,235 mg/L. Hasil yang diperoleh menunjukkan dekolorisasi menggunakan elektroda PbO2/Pb berlangsung hingga 94,03% untuk limbah air sungai di Pekalongan, 96,74 % untuk limbah air sungai di Batang, 97,13 % untuk limbah sebelum dibuang ke sungai.


2021 ◽  
Vol 1 (2) ◽  
Author(s):  
Kholis Normania Laily ◽  
Muhammad Amin ◽  
Dwi Sat Agus Yuwana

<p>Kawasan pesisir erat kaitannya dengan perubahan sifat perairan yang terjadi akibat kegiatan manusia, salah satunya yaitu berasal dari air limbah domestik. Berdasarkan hasil pengamatan pada pemukiman pesisir Pantai Blebak Kabupaten Jepara, menunjukkan bahwa masyarakat masih membuang air limbah langsung ke badan tanah tanpa melakukan pengolahan, sehingga mencemari kualitas air tanah. Oleh karena itu diperlukan metode dalam pengolahan air limbah.</p><p> </p><p>Penelitian ini menggunakan metode <em>Constructed Wetland Subsurface Flow Horizontal</em> dengan tanaman <em>Typha angustifolia,</em> <em>Cladium</em>, dan<em> Dracaena sanderiana</em>. Parameter senyawa yang ditinjau adalah BOD (<em>Biochemical Oxygen Demand</em>), COD (<em>Chemical Oxygen Demand</em>), dan TSS (<em>Total Suspended Solid</em>). Pengolahan dilakukan dengan waktu detensi 3,6, dan 9 hari. Sedangkan analisis<em> </em>data yang digunakan yaitu analisis uji Anova.</p><p> </p><p>Hasil penelitian menunjukkan bahwa nilai penyisihan tertinggi kadar BOD, COD, dan TSS terjadi pada waktu detensi ke -9 hari. Penyisihan kadar BOD tertinggi yaitu sebesar 90,24%, untuk parameter COD yaitu sebesar 90,46%, sedangkan penyisihan TSS tertinggi yaitu sebebesar 90,61%.</p>


Sign in / Sign up

Export Citation Format

Share Document