scholarly journals QUALITATIVE RESEARCH AND EVALUATION OF LANDFILL LEACHATE / KOKYBINIAI SĄVARTYNO FILTRATO TYRIMAI IR VERTINIMAS

2013 ◽  
Vol 5 (4) ◽  
pp. 356-362 ◽  
Author(s):  
Irina Kačinskaja ◽  
Kristina Bazienė ◽  
Saulius Vasarevičius

Currently, depositing municipal waste in landfills is the dominating method in Lithuania. A large amount of landfill leachate is the main environmental problem. Municipal waste landfill leachate is characterized by high biochemical oxygen demand (BOD) containing a number of heavy metals and concentration of organic compounds. The colmatation of landfill leachate collection systems is another burning problem that occurs due to certain characteristics of leachate such as suspended solids, an increase in calcium and magnesium concentrations and vital activity of microorganisms. Therefore, it is necessary to examine conditions affecting these parameters. The paper presents and analyses the characteristics of experimental data, assesses the factors having the greatest influence on recent development and introduces the measures that should be taken into account so that to the ensure optimal operation of the systems for collecting municipal waste landfill leachate. Article in Lithuanian. Santrauka Pagrindinis atliekų tvarkymo būdas Lietuvoje yra jų deponavimas sąvartynuose. Viena iš svarbiausių aplinkosauginių problemų – dideli susidarantys sąvartyno filtrato kiekiai. Komunalinių atliekų sąvartynų filtratui būdinga didelis biocheminio deguonies suvartojimas (BDS), filtrate taip pat nemažà sunkiųjų metalų bei organinių junginių koncentracija. Svarbu išskirti ir tokią problemą kaip sąvartyno filtrato surinkimo sistemų kolmatacija, pasireiškianti dėl tam tikrų filtrato savybių: skendinčiųjų medžiagų, kalcio ir magnio koncentracijų padidėjimo ir mikroorganizmų gyvybinės veiklos. Būtina įvertinti sąlygas, turinčias įtakos šių parametrų kitimui. Pateikti minėtų savybių eksperimentinių tyrimų duomenys ir analizė. Įvertinta, kokie veiksniai turi didžiausią įtaką filtrato parametrų kitimui, pavyzdžiui, tai, jog bendrasis kietumas (kalcis ir magnis) lemia pH didėjimą, t. y. terpės šarmėjimą. Be to, išanalizuota, kokių priemonių reikėtų imtis optimaliam komunalinių atliekų sąvartyno filtrato surinkimo sistemų veikimui užtikrinti.

2011 ◽  
Vol 71-78 ◽  
pp. 2852-2855
Author(s):  
Kun Shi ◽  
Ming Zou

The microcosm tests were done to estimated the HRT (Hydraulic Retention Time) and removal efficiency of reflowing treatment of the landfill leachate collected from Dalian Maoyingzi Municipal Solid Waste Landfill, which contained high levels of COD (Chemical Oxygen Demand, 38400 mg/L) and SS (Suspended Solids, 650 mg/L) by the reed constructed wetland located in the south area of Dalian Jiaotong University. The results showed that: (1) The HRT in nature soil cuboids were significant shorter than those in sieved soil cuboids (P<0.01); (2) The removal efficiency among the output water with the trend as follows: Preferential flow (53.9%)<Percolating water (59.2%)<Reflowing water (63.3%); (3) The COD and SS were decreased from 38400 and 650 mg/L to 14080 and 213 mg/L by the way of reflowing with the HSL (Hydraulic Surface Loading) of 0.16 m3/(m2·d) by reflowing (Removal efficiency: COD: 63.3%; SS: 67.3%).


2019 ◽  
Vol 80 (3) ◽  
pp. 458-465 ◽  
Author(s):  
Ahmed Samir Naje ◽  
Mohammed A. Ajeel ◽  
Isam Mohamad Ali ◽  
Hussein A. M. Al-Zubaidi ◽  
Peter Adeniyi Alaba

Abstract In this work, landfill leachate treatment by electrocoagulation process with a novel rotating anode reactor was studied. The influence of rotating anode speed on the removal efficiency of chemical oxygen demand (COD), total dissolved solids (TDS), and total suspended solids (TSS) of raw landfill leachate was investigated. The influence of operating parameters like leachate pH, leachate temperature, current, and inter-distance between the cathode rings and anode impellers on the electrocoagulation performance were also investigated. The results revealed the optimum rotating speed is 150 rpm and increasing the rotating speed above this value led to reducing process performance. The leachate electrocoagulation treatment process favors the neutral medium and the treatment performance increases with increasing current intensity. Furthermore, the electrocoagulation treatment performance improves with increasing leachate temperature. However, the performance reduces with increasing inter-electrode distance.


2017 ◽  
Vol 8 (2) ◽  
pp. 234-243 ◽  
Author(s):  
Mohini Verma ◽  
R. Naresh Kumar

Abstract Landfill leachate and municipal wastewater at various ratios (1:20, 1:10, 1:7 and 1:5) were subjected to coagulation and electrocoagulation (EC). Alum was used in conventional coagulation at pH 6 and aluminum plate as electrode was used in EC at a current density of 386 A/m2 with 5 cm inter electrode spacing. Treatment efficiency was assessed from removal of chemical oxygen demand (COD), total suspended solids (TSS), turbidity, ammonia, nitrate and phosphate. At 1:5 ratio of landfill leachate to municipal wastewater, highest COD removal was with 3.8 g/L alum whereas highest turbidity removal was with 3.3 g/L alum during coagulation. EC exhibited almost similar removal efficiency for all the parameters at different ratios tested except for COD which was considerably higher at 1:20 ratio. Aluminum consumption from electrode was 0.7 g/L following EC as compared to 3.8 g/L alum used in coagulation. The amount of sludge produced was found to be higher with EC as compared to coagulation which could be due to the fact that the electrochemical method was performed for a longer duration than conventional coagulation. For minimal sludge generation, EC reaction time should be ∼30 min. Further studies with EC process on costing and sludge generation will help to advance the technology for wastewater treatment.


2021 ◽  
Vol 42 (3(SI)) ◽  
pp. 775-781
Author(s):  
M.M. Hanafiah ◽  
◽  
N.I.H.A. Aziz ◽  
A.A. Halim ◽  
L.S. Shamdin ◽  
...  

Aim: In this study, Ipomoea aquatica and Pistia stratiotes were used to remove total suspended solids, chemical oxygen demand and ammoniacal nitrogen (NH3-N) from the landfill leachate collected at Ampar Tenang Closed Landfill (ATCL) site in Dengkil, Selangor, Malaysia. Methodology: The physico-chemical characteristics of landfill leachate (pH, temperature, NH3-N, dissolved oxygen, biochemical oxygen demand, chemical oxygen demand, total dissolved solids, total suspended solids, salinity, electrical conductivity and nitrite as well as selected heavy metals were determined before phytoremediation treatment. Results: The physico-chemical properties of leachate samples were found to be lower as compared to the standards set by the government, except for COD (>100 mg l-1). Heavy metals content, Na, Mg and Fe was high in leachate. It was found that the concentrations of NH3-N, COD and TSS in leachate decreased by 57.64%, 26.85% and 62.05% after treatment with Ipomea aquatica, respectively. Whereas, 61%, 32% and 74.7% removal rate was observed for NH3-N, COD and TSS, post-treatment by Pistia stratiotes. One-way ANOVA analysis for Ipomoea aquatica revealed insignificant difference (p>0.05) but for Pistia stratiotes there was a significant difference (p<0.05) in the reduction of TSS, COD and NH3-N concentrations. Interpretation: Based on the findings, Pistia stratiotes was found more effective than Ipomea aquatica for reducing TSS, COD and NH3-N concentrations from landfill leachate.


2014 ◽  
Vol 70 (12) ◽  
pp. 1941-1947 ◽  
Author(s):  
R. Campos ◽  
F. M. Ferraz ◽  
E. M. Vieira ◽  
J. Povinelli

This study investigated the co-treatment of landfill leachate/domestic wastewater in bench-scale activated sludge (AS) reactors to determine whether the slowly biodegradable organic matter (SBOM) was removed rather than diluted. The AS reactors were loaded with mixtures of raw leachate and leachate that was pretreated by air stripping. The tested volumetric ratios were 0%, 0.2%, 2% and 5%. For all of the tested conditions, the reactors performed better when pretreated leachate was used rather than raw leachate, and the best volumetric ratio was 2%. The following removals were obtained: 97% for the biochemical oxygen demand (BOD5,20), 79% for total suspended solids, 77% for dissolved organic carbon and 84% for soluble chemical oxygen demand. Most of the pretreated leachate SBOM (65%) was removed rather than diluted or adsorbed into the sludge, as confirmed by Fourier transform infrared (FTIR) spectroscopy analyses.


Author(s):  
Hamidi Abdul Aziz ◽  
Nur Syahirah Rahmat ◽  
Motasem Y. D. Alazaiza

Chemical-based coagulants and flocculants are commonly used in the coagulation–flocculation process. However, the drawbacks of using these chemical materials have triggered researchers to find natural materials to substitute or reduce the number of chemical-based coagulants and flocculants. This study examines the potential application of Nephelium lappaceum seeds as a natural coagulant–coagulant aid with Tin (IV) chloride (SnCl4) in eliminating suspended solids (SS), colour, and chemical oxygen demand (COD) from landfill leachate. Results showed that the efficiency of Nephelium lappaceum was low when used as the main coagulant in the standard jar test. When SnCl4 was applied as a single coagulant, as much as 98.4% of SS, 96.8% of colour and 82.0% of COD was eliminated at an optimal dose of 10.5 g/L and pH 7. The higher removal efficiency of colour (88.8%) was obtained when 8.40 g/L of SnCl4 was applied with a support of 3 g/L of Nephelium lappaceum. When SnCl4 was utilised as a coagulant, and Nephelium lappaceum seed was used as a flocculant, the removal of pollutants generally improved. Overall, this research showed that Nephelium lappaceum seed is a viable natural alternative for treating landfill leachate as a coagulant aid.


2018 ◽  
Vol 250 ◽  
pp. 06007 ◽  
Author(s):  
Siti Nor Aishah Mohd-Salleh ◽  
Nur Shaylinda Mohd-Zin ◽  
Norzila Othman ◽  
Nur Syahirah Mohd-Amdan ◽  
Fitryaliah Mohd-Shahli

Treatment on the generated landfill leachate is crucial as it can cause serious toxicological effects and environmental hazards, particularly when the unfavorable contaminants are left accumulated for a long period of time. The purpose of this study was to determine the optimum coagulant dosage of polyaluminium chloride (PAC) in selected dosage ranges (2250-4500 mg/L) and to analyse the ideal pH of leachate sample (pH 3-10). PAC was tested on stabilized leachate taken from Simpang Renggam Landfill Site (SRLS), by investigating the percentage removals of five significant parameters, which were suspended solids, chemical oxygen demand (COD), ammonia, and heavy metals (iron (Fe) and chromium (Cr)). The removal efficiency was determined by a series of experiments using jar test. From the obtained results, it was found that 3750 mg/L and pH 7 were the optimum conditions for PAC dosage and sample pH, respectively. The conventional optimization test showed satisfactory results for suspended solids, COD, Fe, and Cr at 95%, 53%, 97%, and 79% respectively, but had low removal on ammonia at 18%. It can be concluded that the coagulation-flocculation process has the potential to be applied as a primary treatment for stabilized landfill leachate in Malaysia.


2016 ◽  
Vol 33 (4) ◽  
pp. 851-861 ◽  
Author(s):  
E. Fleck ◽  
A. G. Gewehr ◽  
L. F. A. Cybis ◽  
G. R. Gehling ◽  
V. B. Juliano

Sign in / Sign up

Export Citation Format

Share Document