scholarly journals INFLUENCE OF APARTMENTS’ MODERNIZATION ON THE TEMPERATURES OF HEATING SYSTEM IN THE BUILDING

2021 ◽  
Vol 13 (0) ◽  
pp. 1-6
Author(s):  
Giedrius Šiupšinskas ◽  
Juozas Bielskus ◽  
Artur Rogoža

When modernizing apartment buildings, heating appliances are replaced or old ones are left, high thermal temperatures are usually maintained, thus limiting the increase in the DH system’s efficiency. In the article, in order to evaluate the impact of the reduced thermal temperature of the building on space heating when the radiator area remains constant, 3 alternatives have been analyzed. They include cases when after the building modernization old heating appliances are left, but the temperature of the heat carrier is reduced up to 60/40/20 °C in one case or even up to 45/25/20 in another alternative. There has also been examined the possibility of reducing the heat carrier temperature of the heating system without modernization of the building. An hourly data analysis of the heating system model for two typical months of the heating season has been performed. The analysis shows that after the modernization of the building, when heating device areas are left the same, the existing heating temperature can be reduced to 60/40/2020 °C.

Energies ◽  
2019 ◽  
Vol 12 (24) ◽  
pp. 4694
Author(s):  
Tina Lidberg ◽  
Thomas Olofsson ◽  
Louise Ödlund

When buildings become more energy effective, the temperature levels of district heating systems need to be lower to decrease the losses from the distribution system and to keep district heating a competitive alternative on the heating market. For this reason, buildings that are refurbished need to be adapted to suit low-temperature district heating. The aim of this paper is to examine whether four different energy refurbishment packages (ERPs) can be used for lowering the temperature need of a multi-family buildings space heating and domestic hot water (DHW) system as well as to analyse the impact of the DHW circulation system on the return temperature. The results show that for all ERPs examined in this study, the space heating supply temperature agreed well with the temperature levels of a low-temperature district heating system. The results show that the temperature need of the DHW system will determine the supply temperature of the district heating system. In addition, the amount of days with heating demand decreases for all ERPs, which further increases the influence of the DHW system on the district heating system. In conclusion, the DHW system needs to be improved to enable the temperature levels of a low-temperature district heating system.


2019 ◽  
Vol 142 (5) ◽  
Author(s):  
Jiaying Chen ◽  
Hao Li ◽  
Wei Huang ◽  
Zhongbo Li ◽  
Wei Zhong ◽  
...  

Abstract This study investigates the urban heating system (UHS) by taking a look at the heat transportation flexibility of the system. We propose the heating system flexibility (HSF) concept to represent UHS’s capability of meeting the heating demand under different operation conditions during the heating season and give out the corresponding evaluation method. Based on the evaluation method, we investigate the impact of heating network enhancement measures upon HSF by taking a real UHS in Beijing as a demo site. We pick network-wise topological change (extra pipe) and booster pump installation as two representative renovation measures. When an extra pipe close to end-user is introduced to the network, the average flexibility increases but the median flexibility drops. The results show that the introduction of the extra pipe does not reduce the hydraulic imbalance among different substations. A booster pump is more suitable for improving local substation HSF, although such a measure is only effective to a portion of the substations. Overall, the concept of HSF has the potential of being used as an important criterion in the design, operation, and control of UHS and other energy systems.


2021 ◽  
Vol 13 (4) ◽  
pp. 1595
Author(s):  
Valeria Todeschi ◽  
Roberto Boghetti ◽  
Jérôme H. Kämpf ◽  
Guglielmina Mutani

Building energy-use models and tools can simulate and represent the distribution of energy consumption of buildings located in an urban area. The aim of these models is to simulate the energy performance of buildings at multiple temporal and spatial scales, taking into account both the building shape and the surrounding urban context. This paper investigates existing models by simulating the hourly space heating consumption of residential buildings in an urban environment. Existing bottom-up urban-energy models were applied to the city of Fribourg in order to evaluate the accuracy and flexibility of energy simulations. Two common energy-use models—a machine learning model and a GIS-based engineering model—were compared and evaluated against anonymized monitoring data. The study shows that the simulations were quite precise with an annual mean absolute percentage error of 12.8 and 19.3% for the machine learning and the GIS-based engineering model, respectively, on residential buildings built in different periods of construction. Moreover, a sensitivity analysis using the Morris method was carried out on the GIS-based engineering model in order to assess the impact of input variables on space heating consumption and to identify possible optimization opportunities of the existing model.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3350
Author(s):  
Theofanis Benakopoulos ◽  
William Vergo ◽  
Michele Tunzi ◽  
Robbe Salenbien ◽  
Svend Svendsen

The operation of typical domestic hot water (DHW) systems with a storage tank and circulation loop, according to the regulations for hygiene and comfort, results in a significant heat demand at high operating temperatures that leads to high return temperatures to the district heating system. This article presents the potential for the low-temperature operation of new DHW solutions based on energy balance calculations and some tests in real buildings. The main results are three recommended solutions depending on combinations of the following three criteria: district heating supply temperature, relative circulation heat loss due to the use of hot water, and the existence of a low-temperature space heating system. The first solution, based on a heating power limitation in DHW tanks, with a safety functionality, may secure the required DHW temperature at all times, resulting in the limited heating power of the tank, extended reheating periods, and a DH return temperature of below 30 °C. The second solution, based on the redirection of the return flow from the DHW system to the low-temperature space heating system, can cool the return temperature to the level of the space heating system return temperature below 35 °C. The third solution, based on the use of a micro-booster heat pump system, can deliver circulation heat loss and result in a low return temperature below 35 °C. These solutions can help in the transition to low-temperature district heating.


2013 ◽  
Vol 365-366 ◽  
pp. 978-982
Author(s):  
Xiao Wei Feng ◽  
De Wen Zhang

The softening point of modified asphalt is an extremely important indicator to evaluate the high-temperature performance; its the temperature of modified asphalt sample emerging shear deformation under the action of certain shear stress according to the specific heating rate. Its found that in the actual construction and testing, different temperature conditions has a larger impact on the softening point of the modified asphalt, which has adverse affect on road construction. This paper studied and researched the influence of temperature on modified asphalt softening point indicators from the different test temperature, including packing compact temperature, scraper temperature in removal of asphalt that above test mode, standing temperature, curing temperature and initial heating temperature before test.


2021 ◽  
pp. 67-72
Author(s):  
Владимир Леонидович Малкин ◽  
Владимир Александрович Угорелов ◽  
Петр Алексеевич Леончук ◽  
Руслан Андреевич Загуменников

Разработана методика проведения испытаний технических средств защиты стальных сварных бытовых баллонов для сжиженных углеводородных газов (СУГ) от физического разрушения при воздействии на них пожара. В методике содержатся требования к отбору газовых баллонов, рассматриваемым модельным сценариям, установке для испытаний, мероприятиям по подготовке испытаний, порядку их проведения, к отчету о проведении испытаний. Использование предлагаемой методики позволит с высокой степенью достоверности оценивать эффективность применения технических средств защиты стальных бытовых баллонов для СУГ от физического разрушения при воздействии пожара. The paper contains proposals for inclusion in the testing methodology for technical means of protecting gas cylinders from physical destruction. The proposals relate to the choice of typical scenarios characteristic for emergencies and fire development in a room with LPG cylinders: the ingress of cylinders into the fire center, the impact on the cylinder surface of the heat flow of the adjacent fire center; the impact on the surface of the cylinder of LPG vapors jet combustion, simulating the effect of combustion of LPG vapors coming out of the outlet of the valve (safety valve or membrane) of the adjacent cylinder. The design of the installation for testing cylinders in accordance with the above scenarios is presented. There are given requirements for the test preparation procedure, including the verification of documentation, installation of technical protective equipment, filling and delivery of cylinders, checking for gas leaks from cylinders after delivery, installation for testing. A detailed description of the installation procedure is given in accordance with the presented diagrams for various test scenarios. The basic diagrams of the measuring system for the pressure inside the cylinder, mounting of thermocouples on the wall of the cylinder, and remote supply of liquid fuel to trays are described. There is described the test procedure, which consists of turning on the recording systems, gas supplying to the installation, activating the cylinder heating system, video recording of the experiment with timing, closing the valve in front of the pressure sensor after the end of combustion, discharging LPG from the sealed cylinder to the burner. The requirements for the composition of the test report are given, which make it possible to confirm the reliability of the experiments.


2018 ◽  
Vol 51 (3) ◽  
pp. 373-400
Author(s):  
Guoxiang Zhao ◽  
Kewen Li ◽  
Changwei Liu ◽  
Lin Jia ◽  
Bheki Mahlalela Mahlalela

2019 ◽  
pp. 67-73
Author(s):  
I. V. Sergeeva ◽  
A. S. Yamshchikov ◽  
Т. A. Debelova

The article presents the results obtained from the use of aeration with large forms of bactericidal spray (cedar) in preschool and school institutions in Krasnoyarsk in conjunction with individual aeration of small forms of bactericidal spray (cedar) at home in the season of rising incidence of influenza and ARVI. Due to a decrease in the total microbial contamination of the air environment and surface when using the harmless bactericidal spray (cedar), there is a decrease in the incidence of ARVI among children who regularly receive aeration for 4 weeks, and there is a lighter course of ARVI and the absence of complicated forms in 2 times in the observed children in comparison with the group where aeration was not applied. The positive results obtained during the 4-week observation, and the absence of any side effects from the spraying of bactericidal spray (cedar) allows us to recommend it for the prevention of influenza and ARVI during the period of epidemic or seasonal increase in morbidity in organized groups of preschool and school institutions. Considering that since the beginning of the heating season, dry air is installed in the premises, the use of aeration of bactericidal spray reduces the impact of harmful environmental factors on the child’s body, which is facilitated by the ionization and moistening of the air with phytoncide spray components.


Sign in / Sign up

Export Citation Format

Share Document