scholarly journals Validation of the HERA Phase I Epoch of Reionization 21 cm Power Spectrum Software Pipeline

2022 ◽  
Vol 924 (2) ◽  
pp. 85
Author(s):  
James E. Aguirre ◽  
Steven G. Murray ◽  
Robert Pascua ◽  
Zachary E. Martinot ◽  
Jacob Burba ◽  
...  

Abstract We describe the validation of the HERA Phase I software pipeline by a series of modular tests, building up to an end-to-end simulation. The philosophy of this approach is to validate the software and algorithms used in the Phase I upper-limit analysis on wholly synthetic data satisfying the assumptions of that analysis, not addressing whether the actual data meet these assumptions. We discuss the organization of this validation approach, the specific modular tests performed, and the construction of the end-to-end simulations. We explicitly discuss the limitations in scope of the current simulation effort. With mock visibility data generated from a known analytic power spectrum and a wide range of realistic instrumental effects and foregrounds, we demonstrate that the current pipeline produces power spectrum estimates that are consistent with known analytic inputs to within thermal noise levels (at the 2σ level) for k > 0.2h Mpc−1 for both bands and fields considered. Our input spectrum is intentionally amplified to enable a strong “detection” at k ∼ 0.2 h Mpc−1—at the level of ∼25σ—with foregrounds dominating on larger scales and thermal noise dominating at smaller scales. Our pipeline is able to detect this amplified input signal after suppressing foregrounds with a dynamic range (foreground to noise ratio) of ≳107. Our validation test suite uncovered several sources of scale-independent signal loss throughout the pipeline, whose amplitude is well-characterized and accounted for in the final estimates. We conclude with a discussion of the steps required for the next round of data analysis.

1998 ◽  
Vol 38 (8-9) ◽  
pp. 443-451 ◽  
Author(s):  
S. H. Hyun ◽  
J. C. Young ◽  
I. S. Kim

To study propionate inhibition kinetics, seed cultures for the experiment were obtained from a propionate-enriched steady-state anaerobic Master Culture Reactor (MCR) operated under a semi-continuous mode for over six months. The MCR received a loading of 1.0 g propionate COD/l-day and was maintained at a temperature of 35±1°C. Tests using serum bottle reactors consisted of four phases. Phase I tests were conducted for measurement of anaerobic gas production as a screening step for a wide range of propionate concentrations. Phase II was a repeat of phase I but with more frequent sampling and detailed analysis of components in the liquid sample using gas chromatography. In phase III, different concentrations of acetate were added along with 1.0 g propionate COD/l to observe acetate inhibition of propionate degradation. Finally in phase IV, different concentrations of propionate were added along with 100 and 200 mg acetate/l to confirm the effect of mutual inhibition. Biokinetic and inhibition coefficients were obtained using models of Monod, Haldane, and Han and Levenspiel through the use of non-linear curve fitting technique. Results showed that the values of kp, maximum propionate utilization rate, and Ksp, half-velocity coefficient for propionate conversion, were 0.257 mg HPr/mg VSS-hr and 200 mg HPr/l, respectively. The values of kA, maximum acetate utilization rate, and KsA, half-velocity coefficient for acetate conversion, were 0.216 mg HAc/mg VSS-hr and 58 mg HAc/l, respectively. The results of phase III and IV tests indicated there was non-competitive inhibition when the acetate concentration in the reactor exceeded 200 mg/l.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ibtissame Khaoua ◽  
Guillaume Graciani ◽  
Andrey Kim ◽  
François Amblard

AbstractFor a wide range of purposes, one faces the challenge to detect light from extremely faint and spatially extended sources. In such cases, detector noises dominate over the photon noise of the source, and quantum detectors in photon counting mode are generally the best option. Here, we combine a statistical model with an in-depth analysis of detector noises and calibration experiments, and we show that visible light can be detected with an electron-multiplying charge-coupled devices (EM-CCD) with a signal-to-noise ratio (SNR) of 3 for fluxes less than $$30\,{\text{photon}}\,{\text{s}}^{ - 1} \,{\text{cm}}^{ - 2}$$ 30 photon s - 1 cm - 2 . For green photons, this corresponds to 12 aW $${\text{cm}}^{ - 2}$$ cm - 2 ≈ $$9{ } \times 10^{ - 11}$$ 9 × 10 - 11 lux, i.e. 15 orders of magnitude less than typical daylight. The strong nonlinearity of the SNR with the sampling time leads to a dynamic range of detection of 4 orders of magnitude. To detect possibly varying light fluxes, we operate in conditions of maximal detectivity $${\mathcal{D}}$$ D rather than maximal SNR. Given the quantum efficiency $$QE\left( \lambda \right)$$ Q E λ of the detector, we find $${ \mathcal{D}} = 0.015\,{\text{photon}}^{ - 1} \,{\text{s}}^{1/2} \,{\text{cm}}$$ D = 0.015 photon - 1 s 1 / 2 cm , and a non-negligible sensitivity to blackbody radiation for T > 50 °C. This work should help design highly sensitive luminescence detection methods and develop experiments to explore dynamic phenomena involving ultra-weak luminescence in biology, chemistry, and material sciences.


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Kwang-Hyun Uhm ◽  
Seung-Won Jung ◽  
Moon Hyung Choi ◽  
Hong-Kyu Shin ◽  
Jae-Ik Yoo ◽  
...  

AbstractIn 2020, it is estimated that 73,750 kidney cancer cases were diagnosed, and 14,830 people died from cancer in the United States. Preoperative multi-phase abdominal computed tomography (CT) is often used for detecting lesions and classifying histologic subtypes of renal tumor to avoid unnecessary biopsy or surgery. However, there exists inter-observer variability due to subtle differences in the imaging features of tumor subtypes, which makes decisions on treatment challenging. While deep learning has been recently applied to the automated diagnosis of renal tumor, classification of a wide range of subtype classes has not been sufficiently studied yet. In this paper, we propose an end-to-end deep learning model for the differential diagnosis of five major histologic subtypes of renal tumors including both benign and malignant tumors on multi-phase CT. Our model is a unified framework to simultaneously identify lesions and classify subtypes for the diagnosis without manual intervention. We trained and tested the model using CT data from 308 patients who underwent nephrectomy for renal tumors. The model achieved an area under the curve (AUC) of 0.889, and outperformed radiologists for most subtypes. We further validated the model on an independent dataset of 184 patients from The Cancer Imaging Archive (TCIA). The AUC for this dataset was 0.855, and the model performed comparably to the radiologists. These results indicate that our model can achieve similar or better diagnostic performance than radiologists in differentiating a wide range of renal tumors on multi-phase CT.


1987 ◽  
Vol 121 ◽  
pp. 287-293
Author(s):  
C.J. Schalinski ◽  
P. Biermann ◽  
A. Eckart ◽  
K.J. Johnston ◽  
T.Ph. Krichbaum ◽  
...  

A complete sample of 13 flat spectrum radio sources is investigated over a wide range of frequencies and spatial resolutions. SSC-calculations lead to the prediction of bulk relativistic motion in all sources. So far 6 out of 7 sources observed with sufficient dynamic range by means of VLBI show evidence for apparent superluminal motion.


2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Jie Liao ◽  
Lan Yang

AbstractTemperature is one of the most fundamental physical properties to characterize various physical, chemical, and biological processes. Even a slight change in temperature could have an impact on the status or dynamics of a system. Thus, there is a great need for high-precision and large-dynamic-range temperature measurements. Conventional temperature sensors encounter difficulties in high-precision thermal sensing on the submicron scale. Recently, optical whispering-gallery mode (WGM) sensors have shown promise for many sensing applications, such as thermal sensing, magnetic detection, and biosensing. However, despite their superior sensitivity, the conventional sensing method for WGM resonators relies on tracking the changes in a single mode, which limits the dynamic range constrained by the laser source that has to be fine-tuned in a timely manner to follow the selected mode during the measurement. Moreover, we cannot derive the actual temperature from the spectrum directly but rather derive a relative temperature change. Here, we demonstrate an optical WGM barcode technique involving simultaneous monitoring of the patterns of multiple modes that can provide a direct temperature readout from the spectrum. The measurement relies on the patterns of multiple modes in the WGM spectrum instead of the changes of a particular mode. It can provide us with more information than the single-mode spectrum, such as the precise measurement of actual temperatures. Leveraging the high sensitivity of WGMs and eliminating the need to monitor particular modes, this work lays the foundation for developing a high-performance temperature sensor with not only superior sensitivity but also a broad dynamic range.


2010 ◽  
Vol 1 (SRMS-7) ◽  
Author(s):  
David Pennicard ◽  
Heinz Graafsma ◽  
Michael Lohmann

The new synchrotron light source PETRA-III produced its first beam last year. The extremely high brilliance of PETRA-III and the large energy range of many of its beamlines make it useful for a wide range of experiments, particularly in materials science. The detectors at PETRA-III will need to meet several requirements, such as operation across a wide dynamic range, high-speed readout and good quantum efficiency even at high photon energies. PETRA-III beamlines with lower photon energies will typically be equipped with photon-counting silicon detectors for two-dimensional detection and silicon drift detectors for spectroscopy and higher-energy beamlines will use scintillators coupled to cameras or photomultiplier tubes. Longer-term developments include ‘high-Z’ semiconductors for detecting high-energy X-rays, photon-counting readout chips with smaller pixels and higher frame rates and pixellated avalanche photodiodes for time-resolved experiments.


2007 ◽  
Vol 16 (1) ◽  
pp. 119-122 ◽  
Author(s):  
Patrick Ledda

In the natural world, the human eye is confronted with a wide range of colors and luminances. A surface lit by moonlight might have a luminance level of around 10−3 cd/m2, while surfaces lit during a sunny day could reach values larger than 105 cd/m2. A good quality CRT (cathode ray tube) or LCD (liquid crystal display) monitor is only able to achieve a maximum luminance of around 200 to 300 cd/m2 and a contrast ratio of not more than two orders of magnitude. In this context the contrast ratio or dynamic range is defined as the ratio of the highest to the lowest luminance. We call high dynamic range (HDR) images, those images (or scenes) in which the contrast ratio is larger than what a display can reproduce. In practice, any scene that contains some sort of light source and shadows is HDR. The main problem with HDR images is that they cannot be displayed, therefore although methods to create them do exist (by taking multiple photographs at different exposure times or using computer graphics 3D software for example) it is not possible to see both bright and dark areas simultaneously. (See Figure 1.) There is data that suggests that our eyes can see detail at any given adaptation level within a contrast of 10,000:1 between the brightest and darkest regions of a scene. Therefore an ideal display should be able to reproduce this range. In this review, we present two high dynamic range displays developed by Brightside Technologies (formerly Sunnybrook Technologies) which are capable, for the first time, of linearly displaying high contrast images. These displays are of great use for both researchers in the vision/graphics/VR/medical fields as well as professionals in the VFX/gaming/architectural industry.


2015 ◽  
Vol 61 (225) ◽  
pp. 89-100 ◽  
Author(s):  
Cameron Lewis ◽  
Sivaprasad Gogineni ◽  
Fernando Rodriguez-Morales ◽  
Ben Panzer ◽  
Theresa Stumpf ◽  
...  

AbstractWe have built and operated an ultra-wideband UHF pulsed-chirp radar for measuring firn stratigraphy from airborne platforms over the ice sheets of Greenland and West Antarctica. Our analysis found a wide range of capabilities, including imaging of post firn–ice transition horizons and sounding of shallow glaciers and ice shelves. Imaging of horizons to depths exceeding 600 m was possible in the colder interior regions of the ice sheet, where scattering from the ice surface and inclusions was minimal. The radar’s high sensitivity and large dynamic range point to loss tangent variations as the dominant mechanism for these englacial reflective horizons. The radar is capable of mapping interfaces with reflection coefficients as low as −80 dB near the firn–ice transition and as low as −64 dB at depths of 600 m. We found that firn horizon reflectivity strongly mirrored density variance, a result of the near-unity interfacial transmission coefficients. Zones with differing compaction mechanisms were also apparent in the data. We were able to sound many ice shelves and areas of shallow ice. We estimated ice attenuation rates for a few locations, and our attenuation estimates for the Ross Ice Shelf, West Antarctica, appear to agree well with earlier reported results.


1992 ◽  
Vol 336 (1278) ◽  
pp. 295-306 ◽  

The past 30 years has seen a remarkable development in our understanding of how the auditory system - particularly the peripheral system - processes complex sounds. Perhaps the most significant has been our understanding of the mechanisms underlying auditory frequency selectivity and their importance for normal and impaired auditory processing. Physiologically vulnerable cochlear filtering can account for many aspects of our normal and impaired psychophysical frequency selectivity with important consequences for the perception of complex sounds. For normal hearing, remarkable mechanisms in the organ of Corti, involving enhancement of mechanical tuning (in mammals probably by feedback of electro-mechanically generated energy from the hair cells), produce exquisite tuning, reflected in the tuning properties of cochlear nerve fibres. Recent comparisons of physiological (cochlear nerve) and psychophysical frequency selectivity in the same species indicate that the ear’s overall frequency selectivity can be accounted for by this cochlear filtering, at least in band width terms. Because this cochlear filtering is physiologically vulnerable, it deteriorates in deleterious conditions of the cochlea - hypoxia, disease, drugs, noise overexposure, mechanical disturbance - and is reflected in impaired psychophysical frequency selectivity. This is a fundamental feature of sensorineural hearing loss of cochlear origin, and is of diagnostic value. This cochlear filtering, particularly as reflected in the temporal patterns of cochlear fibres to complex sounds, is remarkably robust over a wide range of stimulus levels. Furthermore, cochlear filtering properties are a prime determinant of the ‘place’ and ‘time’ coding of frequency at the cochlear nerve level, both of which appear to be involved in pitch perception. The problem of how the place and time coding of complex sounds is effected over the ear’s remarkably wide dynamic range is briefly addressed. In the auditory brainstem, particularly the dorsal cochlear nucleus, are inhibitory mechanisms responsible for enhancing the spectral and temporal contrasts in complex sounds. These mechanisms are now being dissected neuropharmacologically. At the cortical level, mechanisms are evident that are capable of abstracting biologically relevant features of complex sounds. Fundamental studies of how the auditory system encodes and processes complex sounds are vital to promising recent applications in the diagnosis and rehabilitation of the hearing impaired.


2011 ◽  
Vol 437 (2) ◽  
pp. 215-222 ◽  
Author(s):  
Christopher G. R. Perry ◽  
Daniel A. Kane ◽  
Chien-Te Lin ◽  
Rachel Kozy ◽  
Brook L. Cathey ◽  
...  

Assessment of mitochondrial ADP-stimulated respiratory kinetics in PmFBs (permeabilized fibre bundles) is increasingly used in clinical diagnostic and basic research settings. However, estimates of the Km for ADP vary considerably (~20–300 μM) and tend to overestimate respiration at rest. Noting that PmFBs spontaneously contract during respiration experiments, we systematically determined the impact of contraction, temperature and oxygenation on ADP-stimulated respiratory kinetics. BLEB (blebbistatin), a myosin II ATPase inhibitor, blocked contraction under all conditions and yielded high Km values for ADP of >~250 and ~80 μM in red and white rat PmFBs respectively. In the absence of BLEB, PmFBs contracted and the Km for ADP decreased ~2–10-fold in a temperature-dependent manner. PmFBs were sensitive to hyperoxia (increased Km) in the absence of BLEB (contracted) at 30 °C but not 37 °C. In PmFBs from humans, contraction elicited high sensitivity to ADP (Km<100 μM), whereas blocking contraction (+BLEB) and including a phosphocreatine/creatine ratio of 2:1 to mimic the resting energetic state yielded a Km for ADP of ~1560 μM, consistent with estimates of in vivo resting respiratory rates of <1% maximum. These results demonstrate that the sensitivity of muscle to ADP varies over a wide range in relation to contractile state and cellular energy charge, providing evidence that enzymatic coupling of energy transfer within skeletal muscle becomes more efficient in the working state.


Sign in / Sign up

Export Citation Format

Share Document