scholarly journals SUSTAINABLE DESIGN AND ENERGY CONSUMPTION ANALYSIS FOR STRUCTURAL COMPONENTS

2013 ◽  
Vol 8 (1) ◽  
pp. 120-135 ◽  
Author(s):  
Joseph M. Danatzko ◽  
Halil Sezen ◽  
Qian Chen

The engineering community has been striving to design more sustainable buildings in an attempt to reduce both environmental impact and energy use during all phases of design, construction and operation. Design professionals currently have very limited guidance or tools to incorporate life-cycle and sustainability concepts into their designs. After reviewing the capabilities and limitations of four current life cycle analysis (LCA) computer programs, this research has selected the Athena Impact Estimator v4.0 to perform parametric studies of structural members made up of different construction materials. The energy consumption values are calculated and compared for columns, beams, concrete suspended slabs, precast double-tee sections and various other floor types. While Athena did offer some insights based on its LCA results, this research has concluded that existing LCA and sustainability analysis programs have too few options to meet the current needs of design professionals. A more accurate, sophisticated whole-building LCA tool needs to be developed to assess sustainable properties of design alternatives and to produce the most sustainable structural systems.

Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3287
Author(s):  
Alireza Tabrizikahou ◽  
Piotr Nowotarski

For decades, among other industries, the construction sector has accounted for high energy consumption and emissions. As the energy crisis and climate change have become a growing concern, mitigating energy usage is a significant issue. The operational and end of life phases are all included in the building life cycle stages. Although the operation stage accounts for more energy consumption with higher carbon emissions, the embodied stage occurs in a time-intensive manner. In this paper, an attempt has been made to review the existing methods, aiming to lower the consumption of energy and carbon emission in the construction buildings through optimizing the construction processes, especially with the lean construction approach. First, the energy consumption and emissions for primary construction materials and processes are introduced. It is followed by a review of the structural optimization and lean techniques that seek to improve the construction processes. Then, the influence of these methods on the reduction of energy consumption is discussed. Based on these methods, a general algorithm is proposed with the purpose of improving the construction processes’ performance. It includes structural optimization and lean and life cycle assessments, which are expected to influence the possible reduction of energy consumption and carbon emissions during the execution of construction works.


2018 ◽  
Vol 61 (6) ◽  
pp. 1795-1810
Author(s):  
James Bambara ◽  
Andreas K. Athienitis

Abstract. The energy consumption of a building is significantly impacted by its envelope design, particularly for greenhouses where coverings typically provide high heat and daylight transmission. Energy and life cycle cost (LCC) analysis were used to identify the most cost-effective cladding design for a greenhouse located in Ottawa, Ontario, Canada (45.4° N) that employs supplemental lighting. The base case envelope design uses single glazing, whereas the two alternative designs consist of replacing the glass with twin-wall polycarbonate and adding foil-faced rigid insulation (permanent or movable) on the interior surface of the glass. All the alternative envelope designs increased electricity consumption for lighting and decreased heating energy use except when permanent or movable insulation was applied to the north wall and in the case of permanent insulation on the north wall plus polycarbonate on the east wall. This demonstrates how the use of reflective opaque insulation on the north wall can be beneficial for redirecting light onto the crops to achieve simultaneous reductions in electricity and heating energy costs. A maximum reduction in LCC of 5.5% (net savings of approximately $130,000) was achieved when permanent insulation was applied to the north and east walls plus polycarbonate on the west wall. This alternative envelope design increased electricity consumption for horticultural lighting by 4.3%, reduced heating energy use by 15.6%, and caused greenhouse gas emissions related to energy consumption to decrease by 14.7%. This analysis demonstrates how energy and economic analysis can be employed to determine the most suitable envelope design based on local climate and economic conditions. Keywords: Artificial lighting, Consistent daily light integral, Energy modeling, Envelope design, Greenhouse, Life cycle cost analysis, Light emitting diode, Local agriculture.


Author(s):  
Angela Pakes ◽  
Tuncer Edil ◽  
Morgan Sanger ◽  
Renee Olley ◽  
Tyler Klink

The conventional highway resurfacing technique of mill and overlay (M&O) partially removes the existing pavement and replaces it with asphalt derived from some recycled but mostly virgin materials. Cold-in-place recycling (CIR) is an alternative highway resurfacing method that partially mills the existing pavement and uses it beneath a thinner layer of new asphalt. CIR has become widely used for convenience and cost benefits, but the environmental impacts are poorly quantified. The objective of this study was to quantify the environmental life cycle benefits of using CIR for highway resurfacing instead of M&O. Material quantities and equipment used for CIR and what would have been used in M&O for the same project were provided by contractors for nine highway resurfacing projects in Wisconsin. With this information, a life cycle assessment (LCA) tool was used to determine the relative environmental impacts of the two methods, with energy consumption, water usage, and carbon dioxide emissions chosen as the metrics of the LCA. Results show average environmental savings of 23% in energy consumption and carbon dioxide emissions and 20% in water consumption when using CIR instead of M&O for highway resurfacing. Additionally, CIR reduced virgin aggregate consumption by 37%. Environmental savings achieved by using CIR were found to be directly related to the reduction in volume of new hot mix asphalt (HMA) used, and to the reduction in transportation of materials to and from the site. Linear correlations that can be used to estimate savings of future CIR projects were projected.


2020 ◽  
Vol 12 (1) ◽  
pp. 351 ◽  
Author(s):  
Hossein Omrany ◽  
Veronica Soebarto ◽  
Ehsan Sharifi ◽  
Ali Soltani

Residential buildings are responsible for a considerable portion of energy consumption and greenhouse gas emissions worldwide. Correspondingly, many attempts have been made across the world to minimize energy consumption in this sector via regulations and building codes. The focus of these regulations has mainly been on reducing operational energy use, whereas the impacts of buildings’ embodied energy are frequently excluded. In recent years, there has been a growing interest in analyzing the energy performance of buildings via a life cycle energy assessment (LCEA) approach. The increasing amount of research has however caused the issue of a variation in results presented by LCEA studies, in which apparently similar case studies exhibited different results. This paper aims to identify the main sources of variation in LCEA studies by critically analyzing 26 studies representing 86 cases in 12 countries. The findings indicate that the current trend of LCEA application in residential buildings suffers from significant inaccuracy accruing from incomplete definitions of the system boundary, in tandem with the lack of consensus on measurements of operational and embodied energies. The findings call for a comprehensive framework through which system boundary definition for calculations of embodied and operational energies can be standardized.


2011 ◽  
Vol 55-57 ◽  
pp. 729-736 ◽  
Author(s):  
Tao Liu ◽  
Hai Hong Huang ◽  
Zhi Feng Liu ◽  
Guang Fu Liu

The product life cycle energy consumption model was established considering the impact of remanufacturing on the product lifecycle, and the energy consumption quantitative method was given. In order to optimize the life of a product, a method to calculate its life cycle critical point was proposed. The energy consumption model was applied to two types of gearboxes, new and remanufactured, to compare their life cycle energy, and the energy-saving design scheme optimization was achieved.


2011 ◽  
Vol 243-249 ◽  
pp. 5275-5279
Author(s):  
Hai Bei Xiong ◽  
Yang Zhao

Life cycle assessment (LCA) of a building is a new methodology which accepted as one of the best ways to estimate the environment impacts of a building during its life. In this paper, LCA analysis on a primary school wooden dormitory was conducted using Athena software firstly. Then two others construction materials, namely, concrete and brick, were assumed to be adopted to construct the dormitory. Also the LCA analysis was conducted on the two dormitories using concrete and brick. The comparison on LCA results of the three buildings using different construction materials showed that the dormitory constructed by wood is relatively greener than that of dormitory constructed by concrete and brick.


2021 ◽  
Author(s):  
◽  
Nicolas Perez Fernandez

<p>This thesis studies the influence of construction materials on the life-cycle energy consumption and carbon dioxide (CO2) emissions of medium sized low energy consumption commercial buildings. When describing buildings by materials, there is a tendency to label them according to the main structural material used. However, the vast majority of commercial buildings use a large number of materials. Hence it is not clear which materials or combinations of materials can achieve the best performance, in terms of lifecycle energy use and CO2 emissions. The buildings analysed here were based on an actual six-storey 4250m2 (gross floor area) building, with a mixed-mode ventilation system, currently under construction at the University of Canterbury in Christchurch. While the actual building is being constructed in concrete, the author has designed two further versions in which the structures and finishes are predominantly steel or timber. Despite having different structural materials, large quantities of finishes materials are common to all three buildings; large glazed curtain walls and sun louvers, stairs balustrade and most of the offices internal finishes. A fourth building was also produced in which all possible common finishes' of the timber building were replaced by timber components. This building is labelled as Timber-plus and was included to assess the difference of the three initial 'common finishes' buildings against a building that might be expected to have a low or even negative total embodied CO2 emission in structure and finishes. In order to highlight the influence of materials, each building was designed to have a similar indoor climate with roughly the same amount of operational energy for heating and cooling over its full life. Both energy use and CO2 emissions have been assessed over three main stages in the life (and potential environmental impact) of a building: initial production of the building materials (initial embodied energy and initial embodied CO2 emissions); operation of the building (mainly in terms of its energy use); and the refurbishment and maintenance of the building materials over the building's effective life (recurrent embodied energy and CO2 emissions). Calculation of embodied energy and embodied CO2 emissions are based on materials' estimates undertaken by a Quantity Surveyor. DesignBuilder software was used to estimate whole life-cycle energy used and CO2 emitted in the operation of the buildings over a period of 60 years. Two different methods for embodied energy and embodied CO2 calculation were applied to the four buildings. The first method was by multiplying the volume of each material in the schedule calculated by the Quantity Surveyor by the New Zealand specific coefficients of embodied energy and embodied CO2 produced by Andrew Alcorn (2003). The second method was analysing the same schedule of materials with GaBi professional LCA software. Materials' inventories in GaBi are average German industry data collected by PE Europe between 1996 and 2004 (Alcorn, 2003; Nebel & Love, 2008). The energy results of the thesis show that when using the Alcorn coefficients, the total embodied energy (initial plus recurrent embodied energy) averaged 23% and operating energy consumption averaged 77% of the total life-cycle energy consumption for the four buildings. Using the GaBi coefficients, total embodied energy averaged 19% and operating energy consumption averaged 81% of the total life-cycle energy consumption of the four buildings. Using the Alcorn coefficients, the difference between the highest (steel building) and lowest (timber-plus building) life-cycle energy consumption represents a 22% increment of the highest over the lowest. Using the GaBi coefficients, the difference between the lowest (timber-plus building) and the highest (timber building) life-cycle energy consumption represents a 15% increment of the highest over the lowest. The CO2 results shows that when using the Alcorn coefficients, the total embodied CO2 emissions averaged 7% and operating CO2 emissions averaged 93%. Using the GaBi coefficients, total embodied CO2 emissions averaged 16% and operating CO2 emissions averaged 84% of the life-cycle CO2 emissions of the four buildings. Using the Alcorn coefficients, the difference between the highest (steel building) and lowest (timber-plus building) life-cycle CO2 emissions represents a 27% increment of the highest over the lower. Using the GaBi coefficients, the difference between the highest (timber building) and the lowest (timber-plus building) lifecycle CO2 emissions represents a 9% increment of the highest over the lowest. While for the case of embodied energy the Alcorn results averaged 32% higher than the GaBi, in the case of embodied CO2 the Alcorn results averaged 62% lower than the GaBi. Major differences in the results produced when using the two different sets of embodied energy and CO2 coefficients are due mainly to their different approaches to the CO2 sequestration in timber materials. While the Alcorn coefficients account for the CO2 sequestration of timber materials, the GaBi coefficients do not. This is particularly noteworthy as the CO2 sequestration of timber has been neglected in previous research. It was established that embodied energy can significantly influence the life-cycle energy consumption and CO2 emissions of contemporary low energy buildings. Using the Alcorn coefficients, the steel building embodied the equivalent of 27 years of operating energy consumption and 12 years of operating CO2 emissions. At the other end of the spectrum the timber-plus building embodied the equivalent of 11 years of operating energy consumption and has stored the equivalent of 3.6 years of operating CO2 emissions. Using the GaBi coefficients, the steel building embodied the equivalent of 19 years of operating energy consumption and 14 years of operating CO2 emissions, while the timber-plus building embodied the equivalent of 8 years of operating energy consumption and 8 years of operating CO2 emissions. These findings are of significance, for example, in the assessment and weighting of the embodied energy and embodied CO2 components of building sustainable rating tools.</p>


Author(s):  
Juliana Monteiro Lopes ◽  
Ilton Curty Leal Junior ◽  
Vanessa De Almeida Guimarães

Currently, concerns with sustainable development lead organizations to improve their production processes in order to reduce greenhouse gases emission and energy consumption. Since the bioethanol supply chain is a CO2 emitter and depends on several energy sources, it becomes important to analyze how to improve this chain regarding environmental issues. Thus, this paper presents a comparative study of scenarios with bioethanol supply chain configurations which use different modal alternatives and renewable energy in all its mid-stages. The analysis was based on LCA (life cycle analysis) concepts and in a partial application of LCI (life cycle inventory), so that we can identify which of these scenarios is most appropriate in terms of lower total energy consumption, greater share of renewable energy use and lower CO2 emissions. Based on concepts found in the bibliographic research, the methodology used and the data collected from documental research, this paper analyzes the supply chain that begins with sugarcane plantation and bioethanol production in the south central region of Brazil with destination to export. Based on the results, we concluded that it is possible to improve the performance of the supply chain in environmental terms with a combination of renewable energy sources and modes of transport that are more suitable to the product studied.


Author(s):  
Patxi Hernandez ◽  
Paul Kenny

Building energy performance regulations and standards around the world are evolving aiming to reduce the energy use in buildings. As we move towards zero energy buildings, the embodied energy of construction materials and energy systems becomes more important, as it represents a high percentage of the overall life cycle energy use of a building. However, this issue is still ignored by many regulations and certification methods, as happens with the European Energy Performance of Buildings Directive (EPBD), which focuses on the energy used in operation. This paper analyses a typical house designed to comply with Irish building regulations, calculating its energy use for heating and how water with the Irish national calculation tool, which uses a methodology in line with the EPBD. A range of measures to reduce the energy performance in use of this typical house are proposed, calculating the reduced energy demand and moving towards a zero energy demand building. A life-cycle approach is added to the analysis, taking into account the differential embodied energy of the implemented measures in relation to the typical house base-case, annualizing the differential embodied energy and re-calculating the overall energy use. The paper discusses how a simplified approach for accounting embodied energy of materials could be useful in a goal to achieve the lowest life-cycle energy use in buildings, and concludes with a note on how accounting for embodied energy is a key element when moving towards zero energy buildings.


2021 ◽  
Author(s):  
◽  
Nicolas Perez Fernandez

<p>This thesis studies the influence of construction materials on the life-cycle energy consumption and carbon dioxide (CO2) emissions of medium sized low energy consumption commercial buildings. When describing buildings by materials, there is a tendency to label them according to the main structural material used. However, the vast majority of commercial buildings use a large number of materials. Hence it is not clear which materials or combinations of materials can achieve the best performance, in terms of lifecycle energy use and CO2 emissions. The buildings analysed here were based on an actual six-storey 4250m2 (gross floor area) building, with a mixed-mode ventilation system, currently under construction at the University of Canterbury in Christchurch. While the actual building is being constructed in concrete, the author has designed two further versions in which the structures and finishes are predominantly steel or timber. Despite having different structural materials, large quantities of finishes materials are common to all three buildings; large glazed curtain walls and sun louvers, stairs balustrade and most of the offices internal finishes. A fourth building was also produced in which all possible common finishes' of the timber building were replaced by timber components. This building is labelled as Timber-plus and was included to assess the difference of the three initial 'common finishes' buildings against a building that might be expected to have a low or even negative total embodied CO2 emission in structure and finishes. In order to highlight the influence of materials, each building was designed to have a similar indoor climate with roughly the same amount of operational energy for heating and cooling over its full life. Both energy use and CO2 emissions have been assessed over three main stages in the life (and potential environmental impact) of a building: initial production of the building materials (initial embodied energy and initial embodied CO2 emissions); operation of the building (mainly in terms of its energy use); and the refurbishment and maintenance of the building materials over the building's effective life (recurrent embodied energy and CO2 emissions). Calculation of embodied energy and embodied CO2 emissions are based on materials' estimates undertaken by a Quantity Surveyor. DesignBuilder software was used to estimate whole life-cycle energy used and CO2 emitted in the operation of the buildings over a period of 60 years. Two different methods for embodied energy and embodied CO2 calculation were applied to the four buildings. The first method was by multiplying the volume of each material in the schedule calculated by the Quantity Surveyor by the New Zealand specific coefficients of embodied energy and embodied CO2 produced by Andrew Alcorn (2003). The second method was analysing the same schedule of materials with GaBi professional LCA software. Materials' inventories in GaBi are average German industry data collected by PE Europe between 1996 and 2004 (Alcorn, 2003; Nebel & Love, 2008). The energy results of the thesis show that when using the Alcorn coefficients, the total embodied energy (initial plus recurrent embodied energy) averaged 23% and operating energy consumption averaged 77% of the total life-cycle energy consumption for the four buildings. Using the GaBi coefficients, total embodied energy averaged 19% and operating energy consumption averaged 81% of the total life-cycle energy consumption of the four buildings. Using the Alcorn coefficients, the difference between the highest (steel building) and lowest (timber-plus building) life-cycle energy consumption represents a 22% increment of the highest over the lowest. Using the GaBi coefficients, the difference between the lowest (timber-plus building) and the highest (timber building) life-cycle energy consumption represents a 15% increment of the highest over the lowest. The CO2 results shows that when using the Alcorn coefficients, the total embodied CO2 emissions averaged 7% and operating CO2 emissions averaged 93%. Using the GaBi coefficients, total embodied CO2 emissions averaged 16% and operating CO2 emissions averaged 84% of the life-cycle CO2 emissions of the four buildings. Using the Alcorn coefficients, the difference between the highest (steel building) and lowest (timber-plus building) life-cycle CO2 emissions represents a 27% increment of the highest over the lower. Using the GaBi coefficients, the difference between the highest (timber building) and the lowest (timber-plus building) lifecycle CO2 emissions represents a 9% increment of the highest over the lowest. While for the case of embodied energy the Alcorn results averaged 32% higher than the GaBi, in the case of embodied CO2 the Alcorn results averaged 62% lower than the GaBi. Major differences in the results produced when using the two different sets of embodied energy and CO2 coefficients are due mainly to their different approaches to the CO2 sequestration in timber materials. While the Alcorn coefficients account for the CO2 sequestration of timber materials, the GaBi coefficients do not. This is particularly noteworthy as the CO2 sequestration of timber has been neglected in previous research. It was established that embodied energy can significantly influence the life-cycle energy consumption and CO2 emissions of contemporary low energy buildings. Using the Alcorn coefficients, the steel building embodied the equivalent of 27 years of operating energy consumption and 12 years of operating CO2 emissions. At the other end of the spectrum the timber-plus building embodied the equivalent of 11 years of operating energy consumption and has stored the equivalent of 3.6 years of operating CO2 emissions. Using the GaBi coefficients, the steel building embodied the equivalent of 19 years of operating energy consumption and 14 years of operating CO2 emissions, while the timber-plus building embodied the equivalent of 8 years of operating energy consumption and 8 years of operating CO2 emissions. These findings are of significance, for example, in the assessment and weighting of the embodied energy and embodied CO2 components of building sustainable rating tools.</p>