High temperature geothermal resources of crustal fault zones: a dedicated approach

Author(s):  
M. Bellanger
Fact Sheet ◽  
2008 ◽  
Author(s):  
Colin F. Williams ◽  
Marshall J. Reed ◽  
Robert H. Mariner ◽  
Jacob DeAngelo ◽  
S. Peter Galanis

2019 ◽  
Vol 7 (1) ◽  
Author(s):  
Hugo Duwiquet ◽  
Laurent Arbaret ◽  
Laurent Guillou-Frottier ◽  
Michael J. Heap ◽  
Mathieu Bellanger

Abstract The present study aims to understand the potential of a new and novel type of geothermal play system for high temperature and electricity production: crustal fault zones (CFZ). According to geological and geophysical data, the Pontgibaud fault zone (French Massif Central) is suspected to host an active hydrothermal system at a depth of a few kilometers. The deep geometry of the fault zone and the permeability distribution are the main unknown parameters that are required to assess the geothermal potential of the Pontgibaud site. Structural and thin-section observations, laboratory permeability and connected porosity measurements and X-ray micro-tomography observations suggest that the hydrothermal system behaves like a double matrix-fracture permeability reservoir. Numerical modeling in which we varied the fault dip and the ratio between the fault zone permeability and host rock, R, was performed. Results indicate that three main convective regimes can be identified (weak convection, single cellular-type convection and bicellular convection). For a sufficiently high fault zone permeability (> 1 × 10−15 m2), buoyancy-driven flow creates a positive thermal anomaly of several tens of °C at a depth of 2–5 km. For a vertical fault zone, the thermal anomaly is larger for higher R values. Numerical models, then applied to the geologically constrained Pontgibaud fault zone, show that a temperature of 150 °C at a depth of 2500 m can be obtained for a fault zone permeability of 1.6 × 10−14 m2. Based on a multi-disciplinary approach, this work establishes a potential predictive tool for future high-temperature geothermal operations within basement rocks hosting large-scale fault systems.


2020 ◽  
Author(s):  
Doris Rupprecht ◽  
Sven Fuchs ◽  
Andrea Förster ◽  
Mariella Penz-Wolfmayr

<p>The GeoTief EXPLORE project aims to explore the geothermal potential and quantify the geothermal resources of the Vienna Basin (Austria) and the underlying Northern Calcareous Alpine basement. The main target of geothermal interest is the massive and tectonically remolded Hauptdolomite facies that has been identified as potential geothermal reservoir in previous studies. Now, this formation is studied using outcrop analogues for the investigation of their petrophysical characterization and specific thermal properties (thermal conductivity and thermal diffusivity).</p><p> </p><p>Here, we report new measurements on a total of 60 samples from 6 outcrops in and around the area of Vienna applying different methods for the laboratory measurement of thermal and hydraulic rock properties. The petrophysical analysis considers the impact of deformation along and across fault zones, which introduces heterogeneity of storage properties and consequently in the thermophysical properties. Using the standard fault core and damage zone model, outcrop samples were grouped into unfractured and fractured protoliths, as well as in fault rocks, like breccias and cataclasites. Rock samples are then classified by their fracture density (m² fracture surface per m³ rock) and by their matrix content and differences in grain sizes, respectively.</p><p> </p><p>The measured thermal rock properties vary significantly between the selected rock groups. The total range [90 % of values] is between 3.2 and 5.0 W/(mK) for thermal conductivity and between 1.3 and 2.7 mm²/s for thermal diffusivity. The results generally met the expected trend for fractured rocks as conductivity and diffusivity decreases with increasing porosity under unsaturated and saturated conditions. The total porosities are less than 5%. The variability of thermal conductivity under saturated conditions shows complex trends depending on the different rock classifications where fault rocks and highly fractured rocks of the damage zone show lower increase in thermal conductivities.</p><p> </p><p>The new petrophysical characterization will be the base for further numerical investigations of the hydraulic and thermal regime as well as for the analysis of the geothermal resources of the Hauptdolomite.</p><p> </p><p> </p><p> </p><p> </p>


2015 ◽  
Vol 120 (5) ◽  
pp. 2974-2987 ◽  
Author(s):  
Satoshi Okumura ◽  
Kentaro Uesugi ◽  
Michihiko Nakamura ◽  
Osamu Sasaki
Keyword(s):  

Fluid infiltration into fault zones and their deeper level counterparts, brittle-ductile shear zones, is examined in five different tectonic environments. In the 2.7 Ga Abitibi Greenstone Belt major tectonic discontinuities have lateral extents of hundreds of kilometres. These structures, initiated as listric normal faults accommodating rift extension of the greenstone belt, acted as sites for the extrusion of komatiitic magmas, and formed submarine scarps which delimit linear belts of clastic and chemical sediments. During reverse motion on the structures, accommodating shortening of the belt, these transcrustal faults were used as a conduit for the ascent of trondhjemitic magmas from the base of the crust, alkaline magmas from the asthenosphere, and for discharge of hundreds of cubic kilometres of hydrothermal fluids. Such fluids were characterized by δ 18 O = 6 ± 2, δD = —50 ± 20, δ 13 C = —4 ± 3, and temperatures of 270-450 °C, probably derived from devolatilization of crustal rocks undergoing prograde metamorphism. Hydrothermal fluids were more radiogenic ( 87 Sr/ 86 Sr = 0.7010-0.7040) and possessed higher values of μ than contemporaneous mantle, komatiites or tholeiites, and thus carried a contribution from older sialic basement. Mineralized faults possess enrichments of l.i.l. elements, including K, Rb, Li, Cs, B and C0 2 , as well as rare elements such as Au, Ag, As, Sb, Se, Te, Bi, W. Fluids were characterized by X CO2 ≈ 0.1, neutral to slightly acidic pH, low salinity (less than 3% by mass), and K /N a ≈ 0.1, carried minor CH4, CO and N 2 , and underwent transient effervescence of CO 2 during decompression. At Yellowknife, a series of large-scale shear zones developed by brittle-ductile mechanisms, involving volume dilation with the migration of ca. 5% (by mass) volatiles into the shear zone from surrounding metabasalts. This early deformation involved no departures in redox state or whole-rock δ 18 O from background states of Fe 2 /eFe = 0.7 and δ 18 O of 7-7.5 ‰ respectively, attesting to conditions of low water/rock ratios. Shear zones subsequently acted as high-permeability conduits for pulsed discharge of more than 9 km 3 of reduced metamorphic hydrothermal fluids at 360-450 °C. The West Bay Fault, a late major transcurrent structure, contains massive vein quartz that grew at 200-300 °C from fluids of 2- 6 % salinity (possibly formation brines). At the Grenville Front, translation was accommodated along two mylonite zones and an intervening boundary fault. The high-temperature (MZ II) and lowtemperature (MZ I) mylonite zones formed at 580-640 °C and 430-490 °C, respectively, in the presence of fluids of metamorphic origin, indigenous to the immediate rocks. A population of post-tectonic quartz veins occupying brittle fractures were precipitated from fluids with extremely negative δ 18 O at 200-300 °C. The water may have been derived from downward penetration into fault zones of low 18 O precipitation on a mountain range induced by continental collision, with uplift accommodated at deep levels by the mylonite zones coupled with rebound on the boundary faults. At Lagoa Real, Brazil, Archaean gneisses overlie Proterozoic sediments along thrust surfaces, and contain brittle-ductile shear zones locally occupied by uranium deposits. Following deformation at 500-540 °C, in the presence of metamorphic fluids and under conditions of low water/rock ratios, shear zones underwent local intense oxidation and desilication. All minerals undergo a shift of — 10‰ δ 18 O, indicating discharge up through the Archaean gneisses of formation brines recharged by meteoric water in the underlying Proterozoic sediments during overthrusting: about 1000 km 3 of solution passed through these structures. The shear zones and Proterozoic sediments are less radiogenic ( 87 Sr/ 86 Sr = 0.720) than contemporaneous Archaean gneisses ( 87 Sr/ 86 Sr = 0.900), corroborating transport of fluids and solutes through the structure from a large external reservoir. Major crustal detachment faults of Tertiary age in the Picacho Cordilleran metamorphic core complex of Arizona show an upward transition from undeformed granitic basement, through mylonitic to brecciated and hydrothermally altered counterparts. The highest tectonic levels are allochthonous, oxidatively altered Miocene volcanics, with hydrothermal sediments in listric normal fault basins. This transition is accompanied by a 12‰ increase in δ 18 O from 7 to 19, and a decrease of temperature of 400 °C, because of expulsion of large volumes of metamorphic fluids during detachment. In the Miocene allochthon, mixing occurred between cool downward-penetrating meteoric thermal waters and hot, deeper aqueous reservoirs. In general, flow regimes in these fault and shear zones follow a sequence from conditions of high temperature and pressure with locally derived fluids at low water/rock ratios during initiation of the structures, to high fluxes of reduced formation or metamorphic fluids along conduits as the structures propagate and intersect hydrothermal reservoirs. Later in the tectonic evolution and at shallower crustal levels, there was incursion of oxidizing fluids from near-surface reservoirs into the faults.


2021 ◽  
Vol 9 ◽  
Author(s):  
Yiman Li ◽  
Jiao Tian ◽  
Yuanzhi Cheng ◽  
Guangzheng Jiang ◽  
Ying Zhang ◽  
...  

Large areas of Yanshan period granites with high heat production values (3–10 μW/m3) and mantle plume around Hainan province co-exist in Igneous Rocks Regions of South China (IRRSC). Surface manifestations are mainly warm/hot springs with temperatures below 90 °C and no typical phenomenon of high temperature resources have been observed. The main objective of this paper is to discuss the existence of high temperature geothermal resources and their possible locations under this kind of geothermal and tectonic background by analysis of high temperature heat sources, borehole temperature measurement, and reservoir temperature estimation. Two possible partial melts of the magma chamber were detected as high temperature heat sources in the Southern Leizhou Peninsular and North Hainan Island at a depth of 8–15 km. Other low resistivity zones in the upper crust are more likely caused by fluid in the formations or faults but not high temperature heat sources. This was also verified by borehole temperature measurement in these two areas, with maximum formation temperatures of 211°C and 185°C found, respectively. Reservoir temperatures from fluid geothermometers show lower temperatures of between 110–160°C for typical geothermal fields over the IRRSC but not in the Southern Leizhou Peninsular and Northern Hainan Island. In all, high temperature geothermal resources may be found in the Southern Leizhou Peninsular and on Northern Hainan Island.


2021 ◽  
Author(s):  
Simon Védrine ◽  
Pascal Tarits ◽  
Mathieu Darnet ◽  
François Bretaudeau ◽  
Sophie Hautot

<p>Electromagnetic geophysical exploration plays a key role in high-temperature geothermal projects to estimate the geothermal potential of a region. The objective of an EM campaign applied to high-temperature geothermal exploration is to obtain an image of the impermeable clay cap, the permeable geothermal reservoir, and the system's heat source at depth, as these three components of the overall geothermal system have distinct electrical signatures. However, deep electromagnetic imaging in the coastal areas of volcanic islands represents a major challenge due to the presence of strong cultural noise induced by urbanized areas concentrated around the coast, the proximity to the sea, strong variations of topography and bathymetry, the small size of targets and the heterogeneity of the near surface. Our objective is the multi-scale integration of airborne transient electromagnetism (ATEM), shallow marine and in land magnetotelluric (MT) and controlled source electromagnetism (CSEM) to improve the reconstruction of deep geological structures by inversion. The contribution of the CSEM method is the key to overcoming cultural electromagnetic noise and exploiting data acquired in urbanized areas. In order to study how to integrate the different EM data, we first apply our methodology to data from a geothermal exploration campaign carried out a few years ago in Martinique in the French West Indies. Then, we present results from runs with synthetic tests for a campaign planned this year in Guadeloupe, also in the French West Indie, whose objective is to increase the production capacity of an existing geothermal field.</p>


2020 ◽  
Author(s):  
Morten Hamremoen Røed

<p><span><span>Exploitation of super-critical water from deep geothermal resources can potentially give a 5-10 fold increase in the power output per well. Such an improvement represents a significant reduction in investment costs for deep geothermal energy projects, thus improving their competiveness. </span></span></p><p><span><span>In the previous European Horizon2020 DESCRAMBLE (Drilling in dEep, Super-CRitical AMBients of continental Europe) project it was demonstrated drilling of a deep geothermal well with super-critical conditions (>375°C, >220 bar) by extending an existing well in Larderello, Italy to a depth of around 4km. As state-of-the-art electronic logging tools could not operate reliably at these conditions, DESCRAMBLE developed and tested a novel pressure and temperature logging tool for these supercritical conditions. Target specification for the slickline operated tool was 8 hours logging operation time at 450°C/450 bar, limited by the critical temperature for the available battery technology used for the application. During testing in the supercritical well in Larderello, Italy in 2017, the tool recorded a maximum well temperature of 443.6°C.</span></span></p><p><span><span>The instrument developed in the DESCRAMBLE project, although being state-of-the-art in its performance, was costly and advanced in addition to having a larger outer diameter than desired in for example slim-well applications. Therefore, there is a need for a simpler, lower cost version of this tool with a smaller outer diameter.</span></span></p><p><span><span>The tool being developed, based on the H2020 DESCRAMBLE project, consists of off-the-shelf high temperature electronics, sensors and batteries shielded from the environment by a heat and pressure shield (Dewar). The target specification for the tool is 600°C/500Bar, with a shorter operational time than the DESCRAMBLE tool. </span></span></p><p><span><span>In this work, we describe the tool requirements and discuss the design choices made regarding mechanical parts, seals, electronics platform, sensors, and available battery technology. 3D CAD drawings and simulations of the thermal performance of the tool will be presented, as well as preliminary test results of the electronic platform combined with the sensors and batteries. Production and testing of the physical tool will not be within the scope of the project.</span></span></p><p> </p>


Geophysics ◽  
1997 ◽  
Vol 62 (4) ◽  
pp. 1069-1086 ◽  
Author(s):  
Philip E. Wannamaker ◽  
Jeffery M. Johnston ◽  
John A. Stodt ◽  
John R. Booker

To address outstanding questions in Mesozoic‐Cenozoic structure and present‐day deep physicochemical state in the region of the southern Cordilleran hingeline, a detailed, east‐west profile of magnetotelluric (MT) soundings 155 km in length was acquired. From these soundings, a resistivity interpretation was produced using an inversion algorithm based on a structural parameterization. In the upper ten kilometers of the transect, the interpretation shows two segments of low resistivity lying beneath allochthonous rocks of the Late Mesozoic, Sevier thrust sheet. Subsequent industry drilling motivated in part by our surveying confirms the existence and position of the eastern subthrust conductor and, more spectacularly, identifies the presence of yet deeper, autochthonous Mesozoic rocks. The conductors cannot be specified uniquely with present public data, because their electrical characteristics appear consistent with Paleozoic, pyrolized graphitic strata of either Late Devonian‐Mississippian or Middle Ordovician age. However, the drilling results show that Late Paleozoic and younger rocks lie underthrust much farther west than recognized previously, and perhaps as far west as the Utah‐Nevada border. A simple structural interpretation is offered where one underthrust segment of low‐resistivity sediments was created originally, but this segment was broken later into two major ones during higher‐angle Tertiary extension. For the middle and lower crust, the MT data imply a nearly 1-D resistivity structure of remarkable uniformity across the entire transect. In particular, there occurs a deep low‐resistivity layer most pronounced (about 8 ohm-m) in the nominal depth interval of 17.5 to 40 km. The MT data indicate that the layer cannot be confined to a single thin layer in the lower crust but instead represents vertically distributed low resistivity. With temperatures estimated from surface heat flow to range from 550°C to 1050°C with depth in the layer, and with a metaigneous mineralogy of high metamorphic grade assumed, mechanisms to produce the low resistivity can be constrained. The deep layer is thus consistent with [Formula: see text] brines at its upper levels, fluids of lower [Formula: see text] activity toward middle levels, and [Formula: see text] melting below about 30 km. The marked uniformity of the deep conductive layer across the transect suggests a similar uniformity of deep physicochemical state. However, this is not at odds with recent analyses of heat flow, Curie depth, Quaternary extension, and basaltic volcanism. Pre‐existing structural fabrics have had no measureable influence on localizing regions of high temperature, fluids and melting in the lower crust, at least averaged over the scale of tens of kilometers. Given its uniformity over a distance of 155 km or more, the depth to the regional deep conductor does not appear related to the distribution of high‐temperature geothermal resources.


1992 ◽  
Vol 29 (7) ◽  
pp. 1474-1491 ◽  
Author(s):  
T. G. Kotzer ◽  
T. K. Kyser ◽  
E. Irving

In the Athabasca Basin, diagenetic hematite of variable paragenesis occurs throughout the sandstones and underlying paleoregolith. This hematite carries three distinct, single-component magnetizations: A (D = 158°, I = 62°, α95 = 5°, n = 21); B (D = 11°, I = −36°, α95 = 7°, n = 6); and C (D = 18°, I = 79°, α95 = 3°, n = 27). In some areas of the sandstones, such as near reactivated fault zones, the diagenetic hematite has been altered to goethite which yields a very low-intensity, incoherent D magnetization. Ages for the A, B, and C magnetizations, inferred from comparisons with paleomagnetic directions in Precambrian rocks whose ages are known approximately, are 1750–1600, 1600–1450, and about 900 Ma, respectively. The A magnetization is carried by the earliest formed hematite, and its estimated age compares well with U–Pb ages of 1650–1700 Ma for early diagenetic apatite. U–Pb and Rb–Sr ages of approximately 1500 and 900 Ma for uraninite and illite coeval with hematite that carries the B and C magnetizations compare well with their ages estimated from paleomagnetism. The development of B magnetization appears to be coeval with high-grade, unconformity-type uranium mineralization.Petrographic and field relationships indicate that the A magnetization is carried by hematite formed during initial diagenesis of the Athabasca sandstones, the B magnetization is carried by hematite formed during peak diagenesis, and the C magnetization is carried by hematite formed during subsequent high-temperature hydrothermal alteration. The incoherent D magnetizations have resulted from degradation of hematite to goethite as a result of incursion of low-temperature meteoric waters along fault zones that have been continuously reactivated since the late Precambrian. δ18O values of clay minerals and of the coeval hematite which carries the B and C magnetization indicate that they were formed from a fluid having temperatures of 150–200 °C and δ18O values near 1.0‰. Fluids that deposited the early formed hematite carrying the A magnetism are relatively 18O depleted, with values of approximately 0.8‰ and somewhat lower temperatures of 120–160 °C. Intermingling of A, B, and C magnetizations indicates either that hematite may be deposited by one fluid and reprecipitated by a subsequent fluid, or that fluid flow was controlled by local variations in permeability. Evidently, fluid flow has been episodic and basin wide and has occurred over a time span on the order of 108 years. It is suggested that the stratigraphy of the sandstones controlled the basin-wide lateral migration of the basinal fluids and that faults facilitated interformational fluid flow.


Sign in / Sign up

Export Citation Format

Share Document