Suggested Qualification Test Procedure to Secure Splitting Resistance in Pretensioned Concrete Members

2021 ◽  
Vol 41 ◽  
pp. 75-84
Author(s):  
Adrijana Savić ◽  
Robert J. Peterman ◽  
B. Terry Beck

Prestressed concrete ties could develop end-splitting cracks along tendons due to lateral bursting stresses. The lateral bursting stresses can form due to Hoyer effect (change in diameter of the prestressing tendons due to Poisson’s ratio), the jacking force in the tendons, geometrical features and indent characteristics of the prestressing tendons. End-splitting cracks can occur immediately after de-tensioning procedure in some cases, but they also can be developed during the first weeks after de-tensioning procedure due to sustained lateral stresses exerted by the prestressing tendons. The ability of concrete to resist these bursting stresses without cracking is primarily the function of the thickness of concrete cover, the type of concrete mixture used and the maximum compressive strength of the concrete. Qualification test will be great tool for prestressed concrete tie manufacturers to identify tie designs that may be susceptible to end-splitting cracks. This test was formally adopted as section 4.2.4 in Chapter 30 of the 2021 AREMA Manual for Railway Engineering.

Author(s):  
Adrijana Savic ◽  
B. Terry Beck ◽  
Robert J. Peterman

Abstract Prestressed concrete ties could develop end-splitting cracks along tendons due to lateral bursting stresses. The lateral bursting stresses can form due to Hoyer effect (change in diameter of the prestressing tendons due to Poisson’s ratio, the jacking force in the tendons, geometrical features, and indent characteristics of the prestressing tendons. End-splitting cracks can occur immediately after de-tensioning procedure in some cases, but they also can be developed during the first weeks after de-tensioning procedure due to sustained lateral stresses exerted by the prestressing tendons. The ability of concrete to resist these bursting stresses without cracking is primarily the function of the thickness of concrete cover, the type of concrete mixture used and the maximum compressive strength of the concrete. The test purpose was to identify tie designs that may be susceptible to end-splitting cracks. The Qualification test will be great tool to identify tie designs that have ability to form end-splitting cracks. The System Qualification Test involves six pre-tensioned concrete prisms with the same prestressing tendons and concrete mixture that is used in the concrete ties, except that the edge distance for the prisms is reduced by approximately 25 percent. If this reduction in edge distance results in longitudinal splitting cracks along the prestressing tendons, then the system (tie design and material selection) may be susceptible to concrete end-splitting cracks. In this case, changes to the design and/or material selection should be made prior to mass production of ties.


Author(s):  
Adrijana Savic ◽  
B. Terry Beck ◽  
Aaron A. Robertson ◽  
Robert J. Peterman ◽  
Jeremiah Clark ◽  
...  

The bond between wire and concrete is crucial for transferring the stresses between the two materials in a prestressed concrete member. Furthermore, bond can be affected by such variables as thickness of concrete cover, type of pre-stressing (typically indented) wire used, compressive (release) strength of the concrete, and concrete mix. This work presents current progress toward the development of a testing procedure to get a clear picture of how all these parameters can ruin the bond and result in splitting. The objective is to develop a qualification test procedure to proof-test new or existing combinations of pre-stressing wire and concrete mix to ensure a reliable result. This is particularly crucial in the concrete railroad crosstie industry, where incompatible conditions can result in cracking and even tie failure. The goal is to develop the capability to readily identify compatible wire/concrete designs “in-plant” before the ties are manufactured, thereby eliminating the likelihood that defectively manufactured ties will lead to in-track tie failures due to splitting. The tests presented here were conducted on pre-tensioned concrete prisms cast in metal frames. Three beams (prismatic members) with different cross sections were cast simultaneously in series. Four pre-stressing wires were symmetrically embedded into each concrete prism, resulting in a common wire spacing of 2.0 inches. The prisms were 59.5in long with square cross sections. The first prism was 3.5 × 3.5in with cover 0.75in, the second was 3.25 × 3.25in with cover 0.625in and the third prism in series was 3.0 × 3.0 in with cover 0.50in. All pre-stressing wires used in these initial tests were of 5.32 mm diameter and were of the same wire type (indent pattern) denoted by “WE”, which had a spiral-shaped geometry. This is one of several wire types that are the subject of the current splitting propensity investigation. Others wire types include variations of the classical chevron shape, and the extreme case of smooth wire with no indentions. The wires were initially tensioned to 7000 pounds (31.14 KN) and then gradually de-tensioned after reaching the desired compressive strength. The different compressive (release strength) strength levels tested included 3500 psi (24.13 MPa), 4500psi (31.03 MPa), 6000 psi (41.37 MPa) and 12000psi (82.74MPa). A consistent concrete mix with water-cement ratio 0.38 was used for all castings. Geometrical and mechanical properties of test prisms were representative of actual prestressed concrete crossties used in the railroad industry. Each prism provided a sample of eight different and approximately independent splitting tests of concrete cover (four wire cover tests on each end) for a given release strength. After de-tensioning, all cracks that appeared on the prisms were marked, and photographs of all prism end surfaces were taken to identify the cracking field. During the test procedure longitudinal surface strain profiles, along with live-end and dead-end transfer lengths, were also measured using an automated Laser-Speckle Imaging (LSI) system developed by the authors. Both quantitative and qualitative assessment of cracking behavior is presented as a function of cover and release strength. In addition to the identification of whether cracking took place at each wire end location, measurements of crack length and crack area are also presented for the given WE wire type. The influence of concrete cover and release strength are clearly indicated from these initial tests. The influence of indented wire type (indent geometry) will also be discussed in this paper, along with a presentation of some preliminary test results. This work represents a successful first step in the development of a qualification test for validating a given combination of wire type, concrete cover, and release strength to improve the reliability of concrete railroad crosstie manufacturing.


Author(s):  
Mark D. Haynes ◽  
Chih-Hang John Wu ◽  
Matthew Arnold ◽  
Naga Narendra B. Bodapati ◽  
B. Terry Beck ◽  
...  

The purpose of this research is to establish mathematical models that predicts the bond strength of a reinforcement wire in prestressed concrete members, given the known geometrical features of the wire. A total of nineteen geometrical features of the reinforcement wire were measured and extracted by a precision non-contact profilometer. With these mathematical models, prestressing reinforcement wires can now be analyzed for their bond strength without destructive testing. These mathematical models, based upon a large collection of empirical data via prestressing reinforcement wires from various wire manufacturers in US and Europe, have the potential to serve as quality assessment tools in reinforcement wire and prestressed concrete member production. Most of these models are very simple and easy to implement in practice, which could provide insight into which reinforcement wires provide the greatest bond strength and which combinations of geometrical features of the reinforcement wire are responsible for providing the bond strength. Our various empirical models have shown that the indent side-wall angle, which is suggested by the ASTM-A881/A881M, may not be the only significant geometrical feature correlated to the transfer length and bond strengths. On the contrary, features such as the indent surface area, indent width, indent edge surface area, indent volume, and release strengths do have significant correlations with the ultimate transfer lengths of the prestressed concrete members. Extensive experiments and testing performed at the Structures Laboratory in Kansas State University, as well as field tests at Transportation Technology Center, Inc. (TTCI) and one Prestressed Concrete Railroad Tie manufacturing facility, have been used to confirm the model predictions. In addition, our experimental results suggest that the maximum pull out force in the un-tensioned pullout testing has significant correlation with the ultimate transfer length. This finding could provide reinforcement wire manufactures with a quality assurance tool for testing their wires prior to the production. The resultant mathematical model relating the wire geometrical features to transfer length is referred to as the Bond Index Number (BIN). The BIN is shown to provide a numerical measure of the bond strength of prestressing steel reinforcement wire, without the need for performing destructive tests with the reinforcement wire. We believe that with the BIN and the maximal pull-out forces from the un-tensioned pull-out tests, one can have better insight into the optimal reinforcement wire design by testing the performance of wires before they are put into production lines.


Author(s):  
Naga Narendra B. Bodapati ◽  
Weixin Zhao ◽  
Robert J. Peterman ◽  
Chih-Hang John Wu ◽  
B. Terry Beck ◽  
...  

A study was conducted to determine the variation in the transfer length of prestressed concrete railroad ties with different indented wire geometries and different concrete properties, including slump and release strength. The study included 12 different reinforcement wire types that are used in concrete railroad ties worldwide. This paper presents the results from transfer length measurements on 96 pretensioned concrete members that were cast in the laboratory. In order to replicate the wire-to-concrete proportions commonly used in prestressed concrete railroad ties, small (3 1/2″ (88.9 mm) × 3 1/2″ (88.9 mm)) prestressed concrete prisms were fabricated and each contained four 5.32-mm-diameter indented wires. A special jacking arrangement was used to ensure that each of the wires was tensioned to the same jacking force. The wires were initially tensioned to 7000 pounds (31.14 kN) each, and the transfer of prestress force into the members was accomplished by a gradual release method replicating the one used in most prestressed concrete crosstie manufacturing plants. The study consisted of two phases. In the first phase, 36 concrete prisms were cast to investigate the effect of different wire indent geometry in a 6-inch (152.4mm) slump concrete mix with 4500 psi (31.03 MPa) release strength. In the second phase, a total of 60 prisms were used to investigate the effect of 4 different concrete parameters with a select group of 5 indented wire types. The second phase included concrete release strengths of 3500 psi (24.13 MPa) and 6000 psi (41.37 MPa), and concrete consistencies (slumps) of 3 (76.2) and 9 inches (228.6 mm). The results have shown that there is a significant variation in transfer lengths for the different indented wires at the same release strength. Additionally, the results show that the transfer lengths decreased significantly with modest increases in the concrete release strength. However, there was no correlation observed between transfer lengths and different concrete slumps for mixes having the same water-to-cementitious (w/c) ratio. For each concrete pour, the splitting tensile strength and modulus of elasticity were measured at the time of prestress transfer. All wire indents were measured according to ASTM A-881 [1] and the results of both phases are presented.


2021 ◽  
Vol 39 ◽  
pp. 103-126
Author(s):  
Adrijana Savić ◽  
Aref Shafiei Dastgerdi ◽  
Terry Beck ◽  
Robert J. Peterman ◽  
Aaron Robertson

This research was focused on evaluating the influence of the different variables that affectsplitting in prestressed concrete members, particularly prestressed concrete ties. These include the thickness of concrete cover, release strength of concrete, and the type of wire indentation. Different combinations of these variables can affect splitting. This research was focused on finding the best possible material characteristics to avoid potential failures in the field. The objective of this research was to set the minimum value of the thickness of concrete cover, for different wire types used in manufacturing having given types of aggregate for concrete mixture. The importance of this research was to identify the best materials and the best system (concrete, wire, cover) designs before the production of prestressed concrete ties. Splitting test results presented in this research were focusedon three different thicknesses of concrete cover, three different concrete mixes, a 4500psi concrete release strength, and seven different indented wire types.


2021 ◽  
Vol 1165 ◽  
pp. 65-86
Author(s):  
Adrijana Savić ◽  
Aref Shafiei Dastgerdi ◽  
Robert J. Peterman ◽  
B. Terry Beck

The important characteristic in the creation of longitudinal splitting cracks in pretensioned concrete members has found to be the geometry of the pre-stressing wire indents. Longitudinal splitting along prestressing tendons can result in severe splitting of prestressed member in the field under loading over time. The research evaluated the influence of wire type indentation on the longitudinal splitting in prestressed concrete members fabricated with different concrete mixtures and different compressive strength of concrete. A key objective was to find the best type of wire to avoid failures in the field. A study was conducted at Kansas State University to understand the effect of wire type on the longitudinal splitting between prestressing steel and prestressed concrete. Three different types of wires will be presented in this paper denoted as “WB”, “WF” and “WQ”. The wires have different parameters which include indent depth, indent width, indent sidewall angle, indent pitch and indent volume.


PCI Journal ◽  
2020 ◽  
Vol 65 (6) ◽  
pp. 35-61
Author(s):  
Chungwook Sim ◽  
Maher Tadros ◽  
David Gee ◽  
Micheal Asaad

Ultra-high-performance concrete (UHPC) is a special concrete mixture with outstanding mechanical and durability characteristics. It is a mixture of portland cement, supplementary cementitious materials, sand, and high-strength, high-aspect-ratio microfibers. In this paper, the authors propose flexural design guidelines for precast, prestressed concrete members made with concrete mixtures developed by precasters to meet minimum specific characteristics qualifying it to be called PCI-UHPC. Minimum specified cylinder strength is 10 ksi (69 MPa) at prestress release and 18 ksi (124 MPa) at the time the member is placed in service, typically 28 days. Minimum flexural cracking and tensile strengths of 1.5 and 2 ksi (10 and 14 MPa), respectively, according to ASTM C1609 testing specifications are required. In addition, strain-hardening and ductility requirements are specified. Tensile properties are shown to be more important for structural optimization than cylinder strength. Both building and bridge products are considered because the paper is focused on capacity rather than demand. Both service limit state and strength limit state are covered. When the contribution of fibers to capacity should be included and when they may be ignored is shown. It is further shown that the traditional equivalent rectangular stress block in compression can still be used to produce satisfactory results in prestressed concrete members. A spreadsheet workbook is offered online as a design tool. It is valid for multilayers of concrete of different strengths, rows of reinforcing bars of different grades, and prestressing strands. It produces moment-curvature diagrams and flexural capacity at ultimate strain. A fully worked-out example of a 250 ft (76.2 m) span decked I-beam of optimized shape is given.