Static Loading Test of the End-Bearing Pile under the Sides Friction Action

2013 ◽  
Vol 353-356 ◽  
pp. 974-978
Author(s):  
Xiao Wei Wang ◽  
Nan Gai Yi ◽  
Shi Ping Zhang

Because the pile foundation has the characters of high bearing capacity, small deformation and easy to construct, it is widely used in practical engineering. In order to verify the end-bearing pile loading capability, in this paper, the single pile vertical compressive static load test is used to the on-site measuring point in actual engineering test, and get the Q-S curve of the pile. FEM is used to simulate the test at the same time. The ideal elastic-plastic constitutive model based on Mohr-Coulomb failure criteria is used to simulate foundation soil. Some conclusions are obtained by using large scaled finite element analysis software ADINA to build the 2D plane strain finite element model and to proceed numerical analysis of the pile. Finally, the comparative analysis with the engineering practice is proceeded. It has the practical significance for the structure analysis of the single pile.

2013 ◽  
Vol 7 (1) ◽  
pp. 170-178 ◽  
Author(s):  
Weijun Yang ◽  
Yongda Yang ◽  
Jihua Yin ◽  
Yushuang Ni

In order to study the basic mechanical property of cast-in-place stiffening-ribbed-hollow-pipe reinforced concrete girderless floor, and similarities and differences of the structural performance compared with traditional floor, we carried out the destructive stage loading test on the short-term load test of floor model with four clamped edges supported in large scale, and conducted the long-term static load test. Also, the thesis conducted finite element analysis in virtue of ANSYS software for solid slab floor, stiffening-ribbed-hollow-pipe floor and tubular floor. The experiment indicates that the developing process of cracks, distribution and failure mode in stiffening-ribbed-hollow-pipe floor are similar to that of solid girderless floor, and that this kind of floor has higher bearing capacity and better plastic deformation capacity. The finite element analysis manifests that, compared with solid slab floor, the deadweight of stiffening-ribbed-hollow-pipe floor decreases on greater level while deformation increases little, and that compared with tubular floor, this floor has higher rigidity. So stiffening-ribbed-hollow-pipe reinforced concrete girderless floor is particularly suitable for long-span and large-bay building structure.


2021 ◽  
Vol 2101 (1) ◽  
pp. 012008
Author(s):  
Jinman Wang ◽  
Shaofei Li ◽  
Mingru Zhou ◽  
Lin Zhong ◽  
Yiming Chen

Abstract In order to realize the directional and controllable splitting of splitting grouting, the field grouting test was carried out. Using a new grouting pipe designed, the splitting direction and size of the branch vein are effectively controlled through the control of grouting pressure and grouting amount. In order to explore the bearing characteristics of split grouting pile and provide necessary parameters for the design of split grouting pile composite foundation in engineering practice, the field static load test and indoor geotechnical test of split grouting pile are designed, and the ultimate bearing capacity of single pile and necessary soil parameters are obtained. In order to make up for the limitations of field static load test, the three-dimensional finite element model of pile, soil and branch vein of split grouting pile is established by using the finite element analysis software ABAQUS. The finite element analysis results are compared with the measured values of field test, and the variation laws of pile shaft axial force, stress and displacement of branch vein at different depths, pile side friction, etc. are further explored, Through these changes, the interaction and load transfer mechanism between pile and soil are analyzed, which provides a reference for optimal design.


2012 ◽  
Vol 178-181 ◽  
pp. 2048-2051
Author(s):  
Xian Min Zhang ◽  
Yan Gao

Through the measured simply supported bridge's dynamic parameters, we can establish the finite element model of the structure.As the flexibility matrix can reflect the actual state of the bridge, making the actual measured flexibility matrix as a basis to inverse the bridge’s finite element model .Combined with the engineering practice static load test, we can assess the bearing capacity of the bridge according to inversion model bridge.


2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Caiwei Liu ◽  
Jijun Miao ◽  
Changyong Zhao

In order to get a more accurate finite element model of a spatial lattice structure with bolt-ball joints for health monitoring, a method of modifying the bolt-ball joint stiffness coefficient was proposed. Firstly, the beam element with adjustable stiffness was used in the joint zone in this paper to reveal the semirigid characteristic of the joint. Secondly, the value of stiffness reduction factor (ar) was limited in the range of[0.2,0.8]and the reference value (ar0) of it was suggested to be 0.5 based on referenced literatures. Finally, the finite element model fractional steps updating strategy based on neural network technique was applied and the limited measuring point information was used to form the network input parameter. A single-layer latticed cylindrical shell model with 157 joints and 414 tubes was used in a shaking TABLE test. Based on the measured modal data, the presented method was verified. The results show that this model updating technique can reflect the true dynamic characters of the shell structure better. Moreover, the neural network can be simplified considerably by using this algorithm. The method can be used for model updating of a latticed shell with bolt-ball joints and has great value in engineering practice.


2014 ◽  
Vol 501-504 ◽  
pp. 1297-1300
Author(s):  
Hai Yun Huang ◽  
Jun Ping Zhang

An on-site static load test of a reinforced concrete double-arch bridge with fracture is carried out, and a comparative analysis of the measured experimental results of the bridge working conditions and the calculation results of Midas/civil Finite Element Model is performed. The results show that the performance and structural deformation recoverability of the bridge is weak. The bridges overall load-bearing capacity does not satisfy its designed requirements.


2012 ◽  
Vol 256-259 ◽  
pp. 1139-1143
Author(s):  
Li Lan Zhang ◽  
Yao Dong Wu

This paper through the test results and theoretical calculation of the batter pile static load, analysis of the actual stress state of cables, and according to the test results to determine the level of the foundation soil resistance coefficient ratio and allow level a transplant.


2012 ◽  
Vol 594-597 ◽  
pp. 565-569
Author(s):  
Zi Sen Wei ◽  
Yong Mou Zhang ◽  
Dong Hui Peng

The static load test of composite foundation was simulated by using the nonlinear finite element programs, and the changes of the pile-soil stress ratio and the pile and soil settlements as well as the plastic deformation of composite foundation were analyzed. The simulation results show that: the cushion of flexible pile composite foundation can effectively regulate the pile-soil stress ratio and make the bearing capacity of the lime soil pile and the soil between piles give full play at the same time. The cushion has a distinct role in reducing the pile settlements, however, has little effect in reducing the soil settlements. The reasonable cushion thickness is about 300mm. The composite foundation will emerge local shear failure when it reaches the ultimate bearing capacity. Reducing the pile spacing can increase the ultimate bearing capacity, and the rate of increase shows a gradually increasing trend.


2006 ◽  
Vol 321-323 ◽  
pp. 590-593 ◽  
Author(s):  
Nam Po Kim ◽  
Jung Seok Kim ◽  
Sung Il Seo ◽  
Tae Won Park

This paper shows the experimental study to evaluate the fatigue strength of a bogie frame for Korean tilting train. The various load cases were established based on the international standard (UIC615-4) and the special tilting load case, which is unique in the tilting train, was derived by dynamic analysis and logical assumption of operation under worst tilting condition. The experimental study was conducted by means of two ways, both static and fatigue loading test. Through the static load test, the safety against fatigue was assessed using Goodman diagram of the material used. The fatigue load test was carried out up to 1x107cycles. The fatigue strength was assessed by fatigue crack inspection by means of NDT test at the stage of 6x106cycles and 1x107cycles.


Sign in / Sign up

Export Citation Format

Share Document