Degradation Mechanism of Reinforced Concrete Beam Subjected to Fatigue Loads and Seawater Erosion

2015 ◽  
Vol 744-746 ◽  
pp. 38-45
Author(s):  
Zi Jian Liu ◽  
Bo Diao ◽  
Xiao Ning Zheng

The durability of coastal reinforced concrete bridge structures will be deteriorated during service due to fatigue loads and Chloride erosion. Through the microscopic tests of reinforced concrete beams after fatigue and seawater corrosion, 10 reinforced concrete beams divided into 5 groups subjected to different fatigue loads were investigated under the alternative action of seawater corrosion, where the deterioration of concrete was degraded. From the experiment, it can be concluded that there was significant self-healing phenomenon on the cracked beams by fatigue loading; And there was regular and clear microcracks in the beams when the maximum fatigue load between 0.16~0.24Pu; the cracks of the beams became obvious,micro cracks increased and crystals can be significantly seen in cracks and low lying location when the maximum fatigue load exceeds 0.24Pu.

2015 ◽  
Vol 773-774 ◽  
pp. 1022-1026 ◽  
Author(s):  
Md Noor Noorsuhada ◽  
Ibrahim Azmi ◽  
Muhamad Bunnori Norazura ◽  
Mohd Saman Hamidah ◽  
Mat Saliah Soffian Noor ◽  
...  

Fatigue crack of the precast reinforced concrete beam under repetition loading is vital to be examined. Reinforced concrete structures exposed to excessive repetition loading could lead to the failure of the structures. In order to examine the active fatigue crack, the reinforced concrete beams were subjected to three-point repetition maximum loading. Eight phases of maximum fatigue loading with sinusoidal wave, frequency of 1 Hz and 5000 cycles for each phase were performed on the reinforced concrete beams. The inspection was carried out with visual observation of the crack pattern and acoustic emission technique for each load phase. The signal strength of acoustic emission was investigated. It is found that the signal strength of acoustic emission and crack pattern of the reinforced concrete beam subjected to repetition loadings showed promising results for structural health monitoring.


2019 ◽  
Vol 25 (10) ◽  
pp. 134-153
Author(s):  
Haifaa Dhamad Hasan ◽  
Abbas AbdulMajeed Allawi

This paper introduces experimental results of eighteen simply supported reinforced concrete beams of cross sections ( ) and length 3000 mm to study the effect of lacing reinforcement on the performance of such beams under static and fatigue loads. Twelve reinforced concrete beams (two of them are casted with vertical shear reinforcement used as control beams) are tested under four points bending loading with displacement control technique and six laced reinforced concrete beams were exposed to high frequency (10 Hz) by fixing the fatigue load in each cycle. Three parameters are used in the designed beams, which are: lacing bar diameter (4mm, 6mm, and 8mm), lacing bar inclination angle to horizontal , and lacing steel ratio depending on number of lacing bar in each longitudinal face of beam and lacing bar diameter. The comparison results of experimental tests revealed that the ultimate loads of laced reinforced concrete beams are higher than the conventional reinforced concrete beams due to increasing lacing bar diameter, angle of inclination lacing bar, and lacing steel ratio, while the deflection is reduced. Also, the laced reinforced concrete beams can safely withstand the fatigue loading.


2012 ◽  
Vol 204-208 ◽  
pp. 3123-3127
Author(s):  
Guang Yu Lei ◽  
Chang Hong Wu ◽  
Shi Ming Li

Through the experiment of eight lightweight aggregate reinforced concrete beams under static loading and fatigue loading with constant amplitudes, the deformation rule under fatigue loading was analysed, the rigidity calculation means and formulations of lightweight aggregate reinforced concrete beam under fatigue loading were also discussed.


2018 ◽  
Vol 21 (13) ◽  
pp. 1977-1989 ◽  
Author(s):  
Tengfei Xu ◽  
Jiantao Huang ◽  
Arnaud Castel ◽  
Renda Zhao ◽  
Cheng Yang

In this article, experiments focusing at the influence of steel–concrete bond damage on the dynamic stiffness of cracked reinforced concrete beams are reported. In these experiments, the bond between concrete and reinforcing bar was damaged using appreciate flexural loads. The static stiffness of cracked reinforced concrete beam was assessed using the measured load–deflection response under cycles of loading and unloading, and the dynamic stiffness was analyzed using the measured natural frequencies with and without sustained loading. Average moment of inertia model (Castel et al. model) for cracked reinforced beams by taking into account the respective effect of bending cracks (primary cracks) and the steel–concrete bond damage (interfacial microcracks) was adopted to calculate the static load–deflection response and the natural frequencies of the tested beams. The experimental results and the comparison between measured and calculated natural frequencies show that localized steel–concrete bond damage does not influence remarkably the dynamic stiffness and the natural frequencies both with and without sustained loading applied. Castel et al. model can be used to calculate the dynamic stiffness of cracked reinforced concrete beam by neglecting the effect of interfacial microcracks.


2012 ◽  
Vol 214 ◽  
pp. 306-310
Author(s):  
Han Chen Huang

This study proposes a artificial neural network with genetic algorithm (GA-ANN) for predicting the torsional strength of reinforced concrete beam. Genetic algorithm is used to the optimal network structure and parameters. A database of the torsional failure of reinforced concrete beams with a rectangular section subjected to pure torsion was obtained from existing literature for analysis. This study compare the predictions of the GA-ANN model with the ACI 318 code used for analyzing the torsional strength of reinforced concrete beam. The results show that the proposed model provides reasonable predictions of the ultimate torsional strength of reinforced concrete beams and offers superior torsion accuracy compared to that of the ACI 318-89 equation.


2020 ◽  
Vol 23 (9) ◽  
pp. 1934-1947
Author(s):  
Dapeng Chen ◽  
Li Chen ◽  
Qin Fang ◽  
Yuzhou Zheng ◽  
Teng Pan

The bending behavior of reinforced concrete beams under uniform pressure is critical for the research of the blast-resistance performance of structural components under explosive loads. In this study, a bending test of five reinforced concrete beams with the dimensions of 200 mm (width) × 200 mm (depth) × 2500 mm (length) under uniform load produced by a specific cylinder-shaped rubber bag filled with air or water was conducted to investigate their flexural performances. An air bag load was applied to three of the reinforced concrete beams, a water bag load was applied to one reinforced concrete beam, and the remainder beam was subjected to the 4-point bending load. The experimental results highlighted that the air bag and water bag loading methods can be used to effectively apply uniform loads to reinforced concrete beams. Moreover, the stiffness of the air bag was improved by 123% in accordance with the initial pressure increases from 0.15 to 0.45 MPa. In addition, a finite element model of the test loading system was established using ABAQUS/Standard software. Moreover, the critical factors of the air bag loading method were analyzed using the numerical model. The calculated results were found to be in good agreement with the test data. The established finite element model can therefore be used to accurately simulate the action performances of the uniform loading technique using rubber bags filled with air or water.


2020 ◽  
Vol 12 (20) ◽  
pp. 8328 ◽  
Author(s):  
Tomas Kinderis ◽  
Mindaugas Daukšys ◽  
Jūratė Mockienė

Over the past decade, several types of composite slim floor constructions have been used in multi-storey buildings in Lithuania. In order to study the efficiency of composite beam application in steel-framed multi-storey buildings, Thorbeam (A1), Deltabeam (A2), slim floor beam (A3) and asymmetric slim floor beam (A4) were chosen and evaluated according to nine assessment criteria (beam cost (K1), initial preparation on site (K2), installation time (K3), complexity of installation technology (K4), labour costs (K5), fire resistance (K6), load bearing capacity (K7), beam versatility (K8), and availability of beams (K9)). First, the significance of the rating criteria was selected and the order of the ranking criteria was obtained (K1˃K7˃K3˃K6˃K4˃K5˃K2˃K8˃K9) by means of a survey questionnaire. Second, the beams were ranked according to the points given by the questionnaire respondents as follows: 160 points were given to A2, 144 points to A1, 129 points to A4, and 111 points to A3. Deltabeam is considered to be the most rational alternative of the four beams compared. Calculations done using the Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS) analysis method revealed that composite beam A2 was the best slim floor structure alternative for an eight-storey high-rise commercial residential building frame, A1 ranked second, A4 ranked third, and A3 ranked fourth. In addition, the four composite beams were compared to a reinforced concrete beam (A5) according to three assessment criteria (beam cost including installation (C1), beam self-weight (C2) and fire resistance (C3)). Deltabeam was found to be efficient for use as a slim floor structure in a multi-story building due to having the lowest cost, including installation, and self-weight, and the highest fire resistance compared to other composite beams studied. Although Deltabeams are 1.4 times more expensive than reinforced concrete beams, including installation costs, they save about 2.5% of the building’s height compared to reinforced concrete beams.


2020 ◽  
Vol 10 (3) ◽  
pp. 822 ◽  
Author(s):  
Shatha Alasadi ◽  
Payam Shafigh ◽  
Zainah Ibrahim

The purpose of this paper is to investigate the flexural behavior of over-reinforced concrete beam enhancement by bolted-compression steel plate (BCSP) with normal reinforced concrete beams under laboratory experimental condition. Three beams developed with steel plates were tested until they failed in compression compared with one beam without a steel plate. The thicknesses of the steel plates used were 6 mm, 10 mm, and 15 mm. The beams were simply supported and loaded monotonically with two-point loads. Load-deflection behaviors of the beams were observed, analyzed, and evaluated in terms of spall-off concrete loading, peak loading, displacement at mid-span, flexural stiffness (service and post-peak), and energy dissipation. The outcome of the experiment shows that the use of a steel plate can improve the failure modes of the beams and also increases the peak load and flexural stiffness. The steel development beams dissipated much higher energies with an increase in plate thicknesses than the conventional beam.


2010 ◽  
Vol 452-453 ◽  
pp. 197-200 ◽  
Author(s):  
Zhen Qing Wang ◽  
Zhi Cheng Xue ◽  
Mu Qiao

For the mechanical properties of reinforced concrete under high temperature with large deterioration, the reliability of reinforced concrete beams have been largely discounted. A calculation of fire resistance based on failure probability is given by this paper. Reinforced concrete beam is usually working with cracks. Since each section with cracks has possibility of destruction, the reliability of the beam is calculated by the minimum value of n crack-sections’ resistance. The plastic zone resistance of concrete under high temperature is considered in this paper. A simple and feasible time-variant model of the resistance of reinforced concrete beams under fire and a reliability index analysis method of reinforced concrete beams under fire has been given. The action of ISO834 temperature rising curve on the reliability index of different specifications of concrete beams at different time is analyzed. The action of main parameters on the reliability index changes with time is shown. The fire resistance considers the failure probability is given. The results show that increase the reinforcement ratio and concrete cover thickness appropriately are effective measures to improve the fire resistance limit of reinforced concrete beams.


Sign in / Sign up

Export Citation Format

Share Document