scholarly journals Research on the Efficiency of Composite Beam Application in Multi-Storey Buildings

2020 ◽  
Vol 12 (20) ◽  
pp. 8328 ◽  
Author(s):  
Tomas Kinderis ◽  
Mindaugas Daukšys ◽  
Jūratė Mockienė

Over the past decade, several types of composite slim floor constructions have been used in multi-storey buildings in Lithuania. In order to study the efficiency of composite beam application in steel-framed multi-storey buildings, Thorbeam (A1), Deltabeam (A2), slim floor beam (A3) and asymmetric slim floor beam (A4) were chosen and evaluated according to nine assessment criteria (beam cost (K1), initial preparation on site (K2), installation time (K3), complexity of installation technology (K4), labour costs (K5), fire resistance (K6), load bearing capacity (K7), beam versatility (K8), and availability of beams (K9)). First, the significance of the rating criteria was selected and the order of the ranking criteria was obtained (K1˃K7˃K3˃K6˃K4˃K5˃K2˃K8˃K9) by means of a survey questionnaire. Second, the beams were ranked according to the points given by the questionnaire respondents as follows: 160 points were given to A2, 144 points to A1, 129 points to A4, and 111 points to A3. Deltabeam is considered to be the most rational alternative of the four beams compared. Calculations done using the Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS) analysis method revealed that composite beam A2 was the best slim floor structure alternative for an eight-storey high-rise commercial residential building frame, A1 ranked second, A4 ranked third, and A3 ranked fourth. In addition, the four composite beams were compared to a reinforced concrete beam (A5) according to three assessment criteria (beam cost including installation (C1), beam self-weight (C2) and fire resistance (C3)). Deltabeam was found to be efficient for use as a slim floor structure in a multi-story building due to having the lowest cost, including installation, and self-weight, and the highest fire resistance compared to other composite beams studied. Although Deltabeams are 1.4 times more expensive than reinforced concrete beams, including installation costs, they save about 2.5% of the building’s height compared to reinforced concrete beams.

2010 ◽  
Vol 452-453 ◽  
pp. 197-200 ◽  
Author(s):  
Zhen Qing Wang ◽  
Zhi Cheng Xue ◽  
Mu Qiao

For the mechanical properties of reinforced concrete under high temperature with large deterioration, the reliability of reinforced concrete beams have been largely discounted. A calculation of fire resistance based on failure probability is given by this paper. Reinforced concrete beam is usually working with cracks. Since each section with cracks has possibility of destruction, the reliability of the beam is calculated by the minimum value of n crack-sections’ resistance. The plastic zone resistance of concrete under high temperature is considered in this paper. A simple and feasible time-variant model of the resistance of reinforced concrete beams under fire and a reliability index analysis method of reinforced concrete beams under fire has been given. The action of ISO834 temperature rising curve on the reliability index of different specifications of concrete beams at different time is analyzed. The action of main parameters on the reliability index changes with time is shown. The fire resistance considers the failure probability is given. The results show that increase the reinforcement ratio and concrete cover thickness appropriately are effective measures to improve the fire resistance limit of reinforced concrete beams.


2019 ◽  
Vol 9 (1) ◽  
pp. 4-9
Author(s):  
Sergey S. MORDOVSKY ◽  
Nikolay A. ILYIN ◽  
Denis A. PANFILOV ◽  
Valeriya N. TALANOVA ◽  
Yana A. BUZOVSKAYA

The article presents a new technical solution, which relates to the field of construction, in particular, to the testing of bending reinforced concrete elements - building beams for strength, deformation and fire resistance on a scale model. The new method of solution implies an increase in the information content, visual clarity and depth of experimental studies of reinforced concrete beams as a result of using the cost-effective way of designing geometric and forceful similarity to the scale model of reinforced concrete beams for strength, deformation and fire resistance. The proposed method allows us to estimate the limiting states of a reinforced concrete beam by strength, deformation and fire resistance; develop an analytical model for calculating the actual fire resistance; save on labor costs in the manufacture of large scale model of full scale design for its testing.


2012 ◽  
Vol 166-169 ◽  
pp. 1379-1382 ◽  
Author(s):  
Dong Fu Zhao ◽  
Zuo Kai You ◽  
Dong Dong Liu

To research the temperature field distribution of concrete beams, experiments on fire resistance of 6 reinforced concrete simple-supported beams were completed. Test results indicate that: the trends of the temperature field distribution in each section of beam are the same, but the difference of the values in each section is large; the larger section of beam is, the higher temperature of beam surface and the more slowly the heat transfer to the internal of beam, which shows the increase of concrete cover thickness can improve fire resistance of beams; After the fire, the gradient of temperature field distribution is very serious in the internal of beam; the higher the temperature of the fire, the bigger damage of reinforced concrete beams is.


2018 ◽  
Vol 21 (13) ◽  
pp. 1977-1989 ◽  
Author(s):  
Tengfei Xu ◽  
Jiantao Huang ◽  
Arnaud Castel ◽  
Renda Zhao ◽  
Cheng Yang

In this article, experiments focusing at the influence of steel–concrete bond damage on the dynamic stiffness of cracked reinforced concrete beams are reported. In these experiments, the bond between concrete and reinforcing bar was damaged using appreciate flexural loads. The static stiffness of cracked reinforced concrete beam was assessed using the measured load–deflection response under cycles of loading and unloading, and the dynamic stiffness was analyzed using the measured natural frequencies with and without sustained loading. Average moment of inertia model (Castel et al. model) for cracked reinforced beams by taking into account the respective effect of bending cracks (primary cracks) and the steel–concrete bond damage (interfacial microcracks) was adopted to calculate the static load–deflection response and the natural frequencies of the tested beams. The experimental results and the comparison between measured and calculated natural frequencies show that localized steel–concrete bond damage does not influence remarkably the dynamic stiffness and the natural frequencies both with and without sustained loading applied. Castel et al. model can be used to calculate the dynamic stiffness of cracked reinforced concrete beam by neglecting the effect of interfacial microcracks.


2012 ◽  
Vol 214 ◽  
pp. 306-310
Author(s):  
Han Chen Huang

This study proposes a artificial neural network with genetic algorithm (GA-ANN) for predicting the torsional strength of reinforced concrete beam. Genetic algorithm is used to the optimal network structure and parameters. A database of the torsional failure of reinforced concrete beams with a rectangular section subjected to pure torsion was obtained from existing literature for analysis. This study compare the predictions of the GA-ANN model with the ACI 318 code used for analyzing the torsional strength of reinforced concrete beam. The results show that the proposed model provides reasonable predictions of the ultimate torsional strength of reinforced concrete beams and offers superior torsion accuracy compared to that of the ACI 318-89 equation.


2014 ◽  
Vol 7 (5) ◽  
pp. 723-746 ◽  
Author(s):  
D. M. Santos ◽  
F. R. Stucchi ◽  
A. T. Beck

This paper presents an investigation on the safety of structural elements submitted to pure bending, produced in reinforced concrete, in steel and steel-concrete composites, and designed according to Brazilian codes NBR8681:2003, NBR6118:2007 and NBR8800:2008. The study allows a comparison of the relative safety of beams produced with these materials and designed using these codes. Comparative studies between the performances of different materials are difficult to find in the published literature. The present study shows that reliability indexes for reinforced concrete beams are satisfactory; however, results for steel beams are below limit values established in international design standards. Reliability indexes found herein for steel-concrete composite beams are intermediate to concrete and steel beams.


2017 ◽  
Vol 172 ◽  
pp. 1176-1183 ◽  
Author(s):  
Piotr Turkowski ◽  
Marek Łukomski ◽  
Paweł Sulik ◽  
Paweł Roszkowski

2020 ◽  
Vol 23 (9) ◽  
pp. 1934-1947
Author(s):  
Dapeng Chen ◽  
Li Chen ◽  
Qin Fang ◽  
Yuzhou Zheng ◽  
Teng Pan

The bending behavior of reinforced concrete beams under uniform pressure is critical for the research of the blast-resistance performance of structural components under explosive loads. In this study, a bending test of five reinforced concrete beams with the dimensions of 200 mm (width) × 200 mm (depth) × 2500 mm (length) under uniform load produced by a specific cylinder-shaped rubber bag filled with air or water was conducted to investigate their flexural performances. An air bag load was applied to three of the reinforced concrete beams, a water bag load was applied to one reinforced concrete beam, and the remainder beam was subjected to the 4-point bending load. The experimental results highlighted that the air bag and water bag loading methods can be used to effectively apply uniform loads to reinforced concrete beams. Moreover, the stiffness of the air bag was improved by 123% in accordance with the initial pressure increases from 0.15 to 0.45 MPa. In addition, a finite element model of the test loading system was established using ABAQUS/Standard software. Moreover, the critical factors of the air bag loading method were analyzed using the numerical model. The calculated results were found to be in good agreement with the test data. The established finite element model can therefore be used to accurately simulate the action performances of the uniform loading technique using rubber bags filled with air or water.


2020 ◽  
Vol 10 (3) ◽  
pp. 822 ◽  
Author(s):  
Shatha Alasadi ◽  
Payam Shafigh ◽  
Zainah Ibrahim

The purpose of this paper is to investigate the flexural behavior of over-reinforced concrete beam enhancement by bolted-compression steel plate (BCSP) with normal reinforced concrete beams under laboratory experimental condition. Three beams developed with steel plates were tested until they failed in compression compared with one beam without a steel plate. The thicknesses of the steel plates used were 6 mm, 10 mm, and 15 mm. The beams were simply supported and loaded monotonically with two-point loads. Load-deflection behaviors of the beams were observed, analyzed, and evaluated in terms of spall-off concrete loading, peak loading, displacement at mid-span, flexural stiffness (service and post-peak), and energy dissipation. The outcome of the experiment shows that the use of a steel plate can improve the failure modes of the beams and also increases the peak load and flexural stiffness. The steel development beams dissipated much higher energies with an increase in plate thicknesses than the conventional beam.


2016 ◽  
Vol 707 ◽  
pp. 51-59 ◽  
Author(s):  
Osama Ahmed Mohamed ◽  
Rania Khattab

The behaviour of reinforced concrete beam strengthened with Carbon Fiber Reinforced Polymer (CFRP) and Glass fiber reinforced polymer GFRP laminates was investigated using finite element models and the results are presented in this paper. The numerical investigation assessed the effect of the configuration of FRP strengthening laminates on the behaviour of concrete beams. The load-deflection behaviour, and ultimate load of strengthened beam were compared to those of un-strengthened concrete beams. It was shown that using U-shaped FRP sheets increased the ultimate load. The stiffness of the strengthed beam also increased after first yielding of steel reinforcing bars. At was also observed that strengthening beams with FRP laminates to one-fourth of the beam span, modifies the failure of the beam from shear-controlled near the end of the unstrengthened beam, to flexure-controlled near mid-span. CFRP produced better results compared GFRP in terms of the ability to enhance the behavior of strengthenened reinforced concrete beams.


Sign in / Sign up

Export Citation Format

Share Document