Experimental Investigation on the Flexural Performance of Brick Masonry Wall Retrofitted Using PP-Band Meshes under Cyclic Loading

2016 ◽  
Vol 845 ◽  
pp. 175-180 ◽  
Author(s):  
Andreas Triwiyono ◽  
Frederica Neo ◽  
Johan Ardianto ◽  
Gumbert Maylda Pratama ◽  
Andreas Sugijopranoto

Numbers of residential houses were damaged in some areas caused by earthquakes. The damages greatly affected the number of losses. Most of the houses in some countries are made of brick unreinforced masonry (URM) walls. Improving the structural performance of this kind of masonry has become important. For this reason, experimental study was conducted on the flexural performance of brick walls retrofitted with strapping band (polypropylene/pp-band). The walls were constructed using bricks produced manually with joint mortar ratio of 1 PC: 6 sand, that chosen to represent the actual field conditions of the communities in Indonesia. The aims of the study were to determine the out of plane flexural performance of the non-retrofitted and retrofitted brick masonry walls under cyclic loading by using some variations of the distance between pp-band. The walls were loaded to produce flexural bending that caused vertical and horizontal cracks. The results of the test showed that the retrofitted walls failed by large deformation. After crack, the strength reduced to about 25-50% of the crack load and then regained progressively as residual strength until 150% higher than the strength at crack load by large deformation due to the strapping band mesh. The wall with 10 cm pp-band distance should be used as optimum solution for retrofitting

Author(s):  
M. J. N. Priestley ◽  
D. O. Bridgeman

This paper summarises the results obtained from testing 18 reinforced masonry wall panels under racking load. The programme included tests on both RBM and Hollow Cell types of brick construction under slow cyclic loading. It is shown that satisfactory ductility can be obtained from brick masonry walls if sufficient horizontal steel is provided to carry the full shear load, and if the critical compression zones at the bottom corners of the wall are confined by the use of thin reinforcing plates in the bottom few mortar courses. Without these precautions severe load degradation occurs under successive load reversals.


2010 ◽  
Vol 133-134 ◽  
pp. 201-204
Author(s):  
Ibrahim Mohamad H. Wan ◽  
B.H. Abu Bakar ◽  
M.A. Megat Johari ◽  
P.J. Ramadhansyah

This paper presents the behaviour of moisture movement of calcium silicate brick masonry walls exposed to sodium sulphate environment. The walls were exposed to three sodium sulphate conditions with sulphate concentrations of5%, 10% and 15%. For comparison, some walls were also exposed to dry and wet condition which acts as a control conditions. All specimens were prepared and cured under polythene sheet for 14 days in a controlled environmental room and maintained at relative humidity and temperature of 80 ± 5% and 25 ± 2°C, respectively. After the curing period, the specimens were exposed to sodium sulphate as well as drying and water exposures, during which moisture movement was measured and monitored for a period of up to 7 months. As a result, the moisture expansion was observed and recorded for all masonry wall specimens after exposed to the sulphate condition.


2021 ◽  
Vol 881 ◽  
pp. 149-156
Author(s):  
Mochamad Teguh ◽  
Novi Rahmayanti ◽  
Zakki Rizal

Building material innovations in various interlocking concrete block masonry from local materials to withstand lateral earthquake forces is an exciting issue in masonry wall research. The block hook has an advantage in the interlocking system's invention to withstand loads in the in-plane and out-of-plane orientations commonly required by the masonry walls against earthquake forces. Reviews of the investigation of in-plane and out-of-plane masonry walls have rarely been found in previous studies. In this paper, the results of a series of experimental tests with different interlocking models in resisting the simultaneous in-plane shear and out-of-plane bending actions on concrete blocks are presented. This paper presents a research investigation of various interlocking concrete blocks' mechanical properties with different hook thicknesses. Discussion of the trends mentioned above and their implications towards interlocking concrete block mechanical properties is provided.


Materials ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 2712
Author(s):  
Elena Ferretti

The present paper deals with an improvement of the strengthening technique consisting in the combined use of straps—made of stainless steel ribbons—and CFRP (Carbon Fiber Reinforced Polymer) strips, to increase the out-of-plane ultimate load of masonry walls. The straps of both the previous and the new combined technique pass from one face to the opposite face of the masonry wall through some holes made along the thickness, giving rise to a three-dimensional net of loop-shaped straps, closed on themselves. The new technique replaces the stainless steel ribbons with steel wire ropes, which form closed loops around the masonry units and the CFRP strips as in the previous technique. A turnbuckle for each steel wire rope allows the closure of the loops and provides the desired pre-tension to the straps. The mechanical coupling—given by the frictional forces—between the straps and the CFRP strips on the two faces of the masonry wall gives rise to an I-beam behavior that forces the CFRP strips to resist the load as if they were the two flanges of the same I-beam. Even the previous combined technique exploits the ideal I-beam mechanism, but the greater stiffness of the steel wire ropes compared to the stiffness of the steel ribbons makes the constraint between the facing CFRP strips stiffer. This gives the reinforced structural element a greater stiffness and delamination load. In particular, the experimental results show that the maximum load achievable with the second combined technique is much greater than the maximum load provided by the CFRP strips. Even the ultimate displacement turns out to be increased, allowing us to state that the second combined technique improves both strength and ductility. Since the CFRP strips of the combined technique run along the vertical direction of the wall, the ideal I-beam mechanism is particularly useful to counteract the hammering action provided by the floors on the perimeter walls, during an earthquake. Lastly, when the building suffers heavy structural damage due to a strong earthquake, the box-type behavior offered by the three-dimensional net of straps prevents the building from collapsing, acting as a device for safeguarding life.


2020 ◽  
Vol 2020 ◽  
pp. 1-13
Author(s):  
Qiang Zhou ◽  
Lingyu Yang ◽  
Wenyang Zhao

Masonry structures are widely used in developing countries due to their low cost and simple construction, especially in remote areas, where there are a large number of houses without seismic measures. These buildings are prone to collapse and cause a lot of casualties, even under the action of small earthquakes. For the reinforcement of this structure, a cheap, effective, and easy-to-construct reinforcement method is urgently needed. Therefore, this article studies the reinforcement method of polypropylene bands (PP-bands). We have carried out low-frequency cyclic loading tests for two PP-band reinforced masonry walls and two compared masonry walls. We mainly studied the influence of PP-band and different compressive strengths of plastering mortar on the masonry wall’s seismic capacity. The seismic indicators mainly studied in this article include ultimate bearing capacity, energy dissipation capacity, stiffness degradation, and hysteresis characteristics. The experimental results show that the PP-band can greatly enhance the seismic capacity of the masonry wall. The ultimate bearing capacity, energy dissipation capacity, and displacement ductility of the PP-band reinforced wall are increased by 38%–48%, 22%–47%, and 138%–226%.


Buildings ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. 103
Author(s):  
Houria Hernoune ◽  
Benchaa Benabed ◽  
Antonios Kanellopoulos ◽  
Alaa Hussein Al-Zuhairi ◽  
Abdelhamid Guettala

Near surface mounted (NSM) carbon fibers reinforced polymer (CFRP) reinforcement is one of the techniques for reinforcing masonry structures and is considered to provide significant advantages. This paper is composed of two parts. The first part presents the experimental study of brick masonry walls reinforced with NSM CFRP strips under combined shear-compression loads. Masonry walls have been tested under vertical compression, with different bed joint orientations 90° and 45° relative to the loading direction. Different reinforcement orientations were used including vertical, horizontal, and a combination of both sides of the wall. The second part of this paper comprises a numerical analysis of unreinforced brick masonry (URM) walls using the detailed micro-modelling approach (DMM) by means of ABAQUS software. In this analysis, the non-linearity behavior of brick and mortar was simulated using the concrete damaged plasticity (CDP) constitutive laws. The results proved that the application of the NSM-CFRP strips on the masonry wall influences significantly strength, ductility, and post-peak behavior, as well as changing the failure modes. The adopted DMM model provides a good interface to predict the post peak behavior and failure mode of unreinforced brick masonry walls.


2017 ◽  
Vol 747 ◽  
pp. 119-127 ◽  
Author(s):  
Francesco Monni ◽  
Enrico Quagliarini ◽  
Stefano Lenci

This paper presents the results of an experimental campaign aimed at improving the innovative technique of continuos basalt fiber (BF) stitching in order to repair the masonry panels damaged by seismic events or to enhance the seismic behavior of unreinforced masonry walls. The masonry panels were tested under out-of-plane actions, one of the common way of failure for masonry walls during an earthquake. The most significant change introduced respect to the system already tested in previous studies, is the presence of pre-tensioned elements and mechanical anchorage of the BF ropes, always with the end of proposing a dry retrofitting system. The results indicate the effectiveness of this, increasing the performance of masonry wall specimens under out-of-plane actions respect to the damaged and unreinforced conditions. Besides, this technique potentially appears fully sustainable, because it is cheap, compatible, reversible, fire, and chemical resistant, it improves but not replaces original materials and, finally, it does not substantially use synthetic adhesives. All these reasons make this novel application of BF ropes fully sustainable and specialized to architectural heritage restoration.


Sign in / Sign up

Export Citation Format

Share Document