Initial Results of Monitoring the Temperature on the Facade of Office Building

2019 ◽  
Vol 887 ◽  
pp. 411-418
Author(s):  
Peter Juras ◽  
Radoslav Ponechal ◽  
Daniela Štaffenová

This paper deals with creating of the unique measurement units on the building façade, which enable the possibility to conduct a full-scale measurement of the outdoor climate parameters around the building. The façade of the Research center building, which is a part of University of Zilina campus, is equipped with 36 weather stations to measure the outdoor climate conditions and impact of the building on the approaching wind flow, air temperature distribution, solar radiance impact on the façade etc.In this article, the change of temperatures within the time and place on the facade (sides, position, time), is monitored. This takes into account the surroundings of the building and the temperature on the façade and comparison to the measured “basic” air temperature.

2019 ◽  
Vol 887 ◽  
pp. 579-586
Author(s):  
Peter Juras ◽  
Radoslav Ponechal

This paper describes measurement units on the building façade, which enable the possibility to conduct a full-scale measurement with a very high resolution of the outdoor climate parameters around the building. The façade of the Research center building, which is a part of University of Zilina campus, is equipped with 36 weather stations to measure the outdoor climate conditions and impact of the building on the approaching wind flow and air temperature distribution, solar radiance impact on the façade, etc. In this article, the wind flow around the building in different heights is monitored, analyzed and compared to the free wind flow.


2016 ◽  
Vol 861 ◽  
pp. 213-220 ◽  
Author(s):  
Miroslav Čekon ◽  
Richard Slávik ◽  
Karel Struhala ◽  
Marian Formánek

The passive solar test facilities have recently been created in many research centers all over the world to analyse dynamic outdoor phenomena on buildings and their components. The main objective of these research activities is primarily to evolve a methodology, improve test methods, validate numerical models and measure real thermodynamic properties of building components under outdoor climate conditions. An integration of advanced material solutions into buildings need to be investigated within specific conditions related specifically to outdoor test methods. A research project on Contemporary concepts of climatically active solar facades at the Brno University of Technology does have an ambition to create an experimental full-scale test cell for research of thermal aspects in progressive advances of future solar façade concepts exposed to the real climate conditions. This paper describes the design optimization phase preceding the test cell assembly. This phase includes the analysis of energy and thermal properties based on parametric study features. Computer simulations based on finite element and volume methods are involved in the optimization process. The proposed optimized test cell design is confronted with parametrization of typical thermal aspects to present final test cell demonstration.


Minerals ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 831
Author(s):  
Anatoliy R. Galamay ◽  
Krzysztof Bukowski ◽  
Igor M. Zinczuk ◽  
Fanwei Meng

Currently, fluid inclusions in halite have been frequently studied for the purpose of paleoclimate reconstruction. For example, to determine the air temperature in the Middle Miocene (Badenian), we examine single-phase primary fluid inclusions of the bottom halites (chevron and full-faceted) and near-surface (cumulate) halites collected from the salt-bearing deposits of the Carpathian region. Our analyses showed that the temperatures of near-bottom brines varied in ranges from 19.5 to 22.0 °C and 24.0 to 26.0 °C, while the temperatures of the surface brines ranged from 34.0 to 36.0 °C. Based on these data, such as an earlier study of lithology and sedimentary structures of the Badenian rock salts, the crystallization of bottom halite developed in the basin from concentrated and cooled near-surface brines of about 30 m depth. Our results comply with the data on the temperature distribution in the modern Dead Sea.


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 860
Author(s):  
Piotr Michalak

Modern buildings with new heating, ventilation and air conditioning (HVAC) systems offer possibility to fit parameters of the indoor environment to the occupants’ requirements. The present paper describes the results of measurements performed in an office room in the first Polish passive commercial office building during four months of normal operation. They were used to calculate parameters describing thermal comfort: vertical air temperature profile, floor surface temperature, predicted mean vote (PMV) and predicted percent of dissatisfied (PPD). Obtained results confirmed good thermal conditions in the analysed room. The average temperature of the floor’s surface varied from 20.6 °C to 26.2 °C. The average vertical air temperature, calculated for working days, was from 22.5 °C to 23.1 °C. The temperature difference between the floor and 5 cm below the ceiling was from −0.9 °C to 6.3 °C. The PMV index varied from 0.52 to 1.50 indicating ‘slightly warm’ sensation, in spite of ‘neutral’ reported by employees. Also measured cooling and heating energy consumption was presented. The performed measurements confirmed the ability of thermally activated building system (TABS) to keep good thermal conditions.


Atmosphere ◽  
2018 ◽  
Vol 9 (10) ◽  
pp. 402 ◽  
Author(s):  
Xiaoxue Wang ◽  
Yuguo Li ◽  
Xinyan Yang ◽  
Pak Chan ◽  
Janet Nichol ◽  
...  

The street thermal environment is important for thermal comfort, urban climate and pollutant dispersion. A 24-h vehicle traverse study was conducted over the Kowloon Peninsula of Hong Kong in summer, with each measurement period consisting of 2–3 full days. The data covered a total of 158 loops in 198 h along the route on sunny days. The measured data were averaged by three methods (direct average, FFT filter and interpolated by the piecewise cubic Hermite interpolation). The average street air temperatures were found to be 1–3 °C higher than those recorded at nearby fixed weather stations. The street warming phenomenon observed in the study has substantial implications as usually urban heat island (UHI) intensity is estimated from measurement at fixed weather stations, and therefore the UHI intensity in the built areas of the city may have been underestimated. This significant difference is of interest for studies on outdoor air temperature, thermal comfort, urban environment and pollutant dispersion. The differences were simulated by an improved one-dimensional temperature model (ZERO-CAT) using different urban morphology parameters. The model can correct the underestimation of street air temperature. Further sensitivity studies show that the building arrangement in the daytime and nighttime plays different roles for air temperature in the street. City designers can choose different parameters based on their purpose.


2018 ◽  
Vol 137 (3-4) ◽  
pp. 1957-1973 ◽  
Author(s):  
Andrés Javier Peña Quiñones ◽  
Bernardo Chaves Cordoba ◽  
Melba Ruth Salazar Gutierrez ◽  
Markus Keller ◽  
Gerrit Hoogenboom

2009 ◽  
pp. 61-66 ◽  
Author(s):  
Bram Vanthoor ◽  
Cecilia Stanghellini ◽  
Eldert van Henten ◽  
Pieter de Visser

2016 ◽  
Vol 62 (232) ◽  
pp. 243-255 ◽  
Author(s):  
MICHAEL CONLAN ◽  
BRUCE JAMIESON

ABSTRACTA database of difficult-to-forecast natural persistent deep slab avalanches was analyzed to determine thresholds for parameters that contribute to their release in western Canada. The database included avalanche observations and weather station data. The avalanches were grouped based on their primary cause-of-release, either precipitation loading, wind loading, solar warming or air temperature warming using a multivariate classification tree, which first split using a solar warming parameter. The precipitation group had a median 24 h snowfall of 15 cm and 3 d snowfall of 38 cm at weather stations, mostly at or below treeline. These amounts were likely closer between 20–30 and 50–80 cm at alpine start zones. The wind loading group experienced the most wind-transported snow potential. The solar warming group had predicted solar warming of 5.2°C, 10 cm into the snowpack, on the days of release. The air temperature warming group experienced the highest median maximum air temperature (5°C) on the days of release. These thresholds may be useful to forecast the likelihood of similar avalanches with experienced-based forecasting or with decision aids, although many false alarms are possible. A companion paper, Part II, relates weather model data to avalanche occurrences.


Sign in / Sign up

Export Citation Format

Share Document