The Seismic Behavior of Strengthened Joints between Concrete-Filled Steel Tubes and Beams Based on the Numerical Simulation Technology

2010 ◽  
Vol 150-151 ◽  
pp. 571-575
Author(s):  
Yun Peng Chu ◽  
Yong Yao ◽  
Shu Lian Xiao ◽  
Yue Chen

As a key part in concrete-filled steel tubular frames, the seismic behavior of joints between concrete-filled steel tubes and beams needs more research because of the complexity of stress under the reciprocating load. the behavior of 9 strengthened joints connecting concrete-filled steel tube with H-shaped steel beam have been analyzed under reversed cyclic loading condition by using finite element analysis software ANSYS, and the result show that: (1) The ultimate bearing capacity, energy dissipation capacity and ductility of strengthened joint are obvious better than that of ordinary welded joint; (2) Compared to concrete-filled steel tube the ultimate bearing capacity, energy dissipation capacity and ductility of double-layer concrete-filled steel tubes are better; (3) For the joints connecting double-layer concrete-filled steel tubes with beams, the shape of inner tube have certain effect on the ultimate bearing capacity but little on the energy dissipation capacity and ductility. (4) The shape of stiffened plate has significant influence on the ultimate bearing capacity, energy dissipation capacity and ductility of nodes.

2012 ◽  
Vol 178-181 ◽  
pp. 179-183 ◽  
Author(s):  
Yang Wen

This paper refers to currently the 1.5MW cone tube type wind-driven generator tower, design the model of the concrete-filled steel tube wind turbine tower with three limb columns, and research on the force performance, such as the change of internal force, the process of failure, hysteretic behavior, bearing capacity, ductility and energy dissipation capacity by the pseudo-static experiment on the scale model of wind turbine tower. The study shows that the P- hysteretic curve of lattice concrete-filled steel tube wind-driven generator tower with three limb columns is asymmetric, relatively full “spindle” and the phenomenon of “knead shrink” is not obvious, which account for it has good force behavior and energy dissipation capacity. This kind of tower structure, of which the reverse bearing capacity is greater than the positive, and the reverse ductility coefficient is less than the positive, indicates that it’s reverse plastic deformation ability of the tower structure is weaker than it’s positive.


2019 ◽  
Vol 23 (5) ◽  
pp. 2254-2262 ◽  
Author(s):  
Kaizhong Xie ◽  
Hongwei Wang ◽  
Jinhao Pang ◽  
Jianxi Zhou

Materials ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 2716 ◽  
Author(s):  
Shiming Liu ◽  
Xinxin Ding ◽  
Xiaoke Li ◽  
Yongjian Liu ◽  
Shunbo Zhao

This paper studies the effect of high-strength steel fiber reinforced concrete (SFRC) on the axial compression behavior of rectangular-sectional SFRC-filled steel tube columns. The purpose is to improve the integrated bearing capacity of these composite columns. Nine rectangular-sectional SFRC-filled steel tube columns and one normal concrete-filled steel tube column were designed and tested under axial loading to failure. The compressive strength of concrete, the volume fraction of steel fiber, the type of internal longitudinal stiffener and the spacing of circular holes in perfobond rib were considered as the main parameters. The failure modes, axial load-deformation curves, energy dissipation capacity, axial bearing capacity, and ductility index are presented. The results identified that steel fiber delayed the local buckling of steel tube and increased the ductility and energy dissipation capacity of the columns when the volume fraction of steel fiber was not less than 0.8%. The longitudinal internal stiffening ribs and their type changed the failure modes of the local buckling of steel tube, and perfobond ribs increased the ductility and energy dissipation capacity to some degree. The compressive strength of SFRC failed to change the failure modes, but had a significant impact on the energy dissipation capacity, bearing capacity, and ductility. The predictive formulas for the bearing capacity and ductility index of rectangular-sectional SFRC-filled steel tube columns are proposed to be used in engineering practice.


2019 ◽  
Vol 14 (02) ◽  
pp. 2050007
Author(s):  
Xizhi Zhang ◽  
Shengbo Xu ◽  
Shaohua Zhang ◽  
Gaodong Xu

In this study, two types of novel box connections were developed to connect precast concrete (PC) columns and to ensure load transfer integrity. Cyclic loading tests were conducted to investigate the seismic behavior of the PC columns with proposed connections as well as the feasibility and reliability of novel box connections. The failure mode, hysteretic behavior, bearing capacity, ductility, stiffness degradation and energy dissipation were obtained and discussed. The test results indicated that the all PC columns exhibited the ductile flexural failure mode and that the proposed connections could transfer the force effectively. The adoption of novel box connections could improve the deformation capacity and energy dissipation capacity of PC columns. A higher axial compression ratio could enhance the bearing capacity of PC column with proposed connection but would significantly deteriorate the ductility and energy dissipation capacity. Finite element models were developed and the feasibility of the models was verified by the comparison with the test results.


Materials ◽  
2019 ◽  
Vol 12 (7) ◽  
pp. 1046 ◽  
Author(s):  
Rongling Zhang ◽  
Lina Ma ◽  
Qicai Wang ◽  
Jia Li ◽  
Yu Wang ◽  
...  

To study different lateral restraints, different constituents of expansion agents, the influence of different steel ratios, and concrete creep properties, we carried out experiments with lateral restraint and without lateral restraint conditions separately on 12 specimens with the expansion agent content accounting for 4%, 8%, and 12% respectively. In addition, the creep tests were performed on specimens with different steel ratios of 0.0%, 3.8%, 6.6%, and 9.2%. The test results show that the lateral restraint improves the strength of the system (concrete-filled steel tubes) which resists further load after the concrete ultimate strength is surpassed and reduces the creep. The creep degree of the concrete-filled steel tube with lateral restraint is about 0.09–0.30 times smaller than that of the tube without lateral restraints. The creep degree of the concrete-filled steel tube increases as the steel ratio decreases. Creep tests with different amounts of expansion agent indicate that the creep degree of the concrete structure increases as expansion agent content decreases. To study the internal mechanism of the creep of concrete-filled steel tubes with different lateral restraints and different expansion agent concentrations, a microscopic pore structure test on the steel core concrete was conducted using the RapidAir457 pore structure instrument. Microscopic studies show that the air content and the length of the bubble chord of the laterally restrained core concrete are lower than those without lateral restraint core concrete. The amount of air content and the length of the bubble chord of core concrete specimens increase as the expansion agent content in the core concrete specimens decreases from 12% to 4%. Under the same external loading conditions, as steel ratio increases, the lateral restraint causes a further reduction of creep. The results of this study suggest that the creep of concrete can be reduced by selecting appropriate lateral restraint conditions and an optimal amount of expansion agent in the mix design of concrete for concrete-filled steel tubes.


2020 ◽  
Vol 2020 ◽  
pp. 1-13
Author(s):  
Qiang Zhou ◽  
Lingyu Yang ◽  
Wenyang Zhao

Masonry structures are widely used in developing countries due to their low cost and simple construction, especially in remote areas, where there are a large number of houses without seismic measures. These buildings are prone to collapse and cause a lot of casualties, even under the action of small earthquakes. For the reinforcement of this structure, a cheap, effective, and easy-to-construct reinforcement method is urgently needed. Therefore, this article studies the reinforcement method of polypropylene bands (PP-bands). We have carried out low-frequency cyclic loading tests for two PP-band reinforced masonry walls and two compared masonry walls. We mainly studied the influence of PP-band and different compressive strengths of plastering mortar on the masonry wall’s seismic capacity. The seismic indicators mainly studied in this article include ultimate bearing capacity, energy dissipation capacity, stiffness degradation, and hysteresis characteristics. The experimental results show that the PP-band can greatly enhance the seismic capacity of the masonry wall. The ultimate bearing capacity, energy dissipation capacity, and displacement ductility of the PP-band reinforced wall are increased by 38%–48%, 22%–47%, and 138%–226%.


Materials ◽  
2019 ◽  
Vol 12 (7) ◽  
pp. 1098 ◽  
Author(s):  
Xuetao Lyu ◽  
Yang Xu ◽  
Qian Xu ◽  
Yang Yu

This study investigated the axial compressive performance of six thin-walled concrete-filled steel tube (CFST) square column specimens with steel bar stiffeners and two non-stiffened specimens at constant temperatures of 20 °C, 100 °C, 200 °C, 400 °C, 600 °C and 800 °C. The mechanical properties of the specimens at different temperatures were analyzed in terms of the ultimate bearing capacity, failure mode, and load–displacement curve. The experiment results show that at high temperature, even though the mechanical properties of the specimens declined, leading to a decrease of the ultimate bearing capacity, the ductility and deformation capacity of the specimens improved inversely. Based on finite element software ABAQUS, numerical models were developed to calculate both temperature and mechanical fields, the results of which were in good agreement with experimental results. Then, the stress mechanism of eight specimens was analyzed using established numerical models. The analysis results show that with the increase of temperature, the longitudinal stress gradient of the concrete in the specimen column increases while the stress value decreases. The lateral restraint of the stiffeners is capable of restraining the steel outer buckling and enhancing the restraint effect on the concrete.


2012 ◽  
Vol 193-194 ◽  
pp. 1461-1464
Author(s):  
Bai Shou Li ◽  
Ai Hua Jin

Based on the characteristics of the special-shaped concrete-filled steel tubes and consideration of material nonlinearity of constitutive relation, stimulation of 6 T-shaped thin-walled ribbed and un-ribbed concrete-filled steel tube short columns is implemented, as well as comparable analysis of stress, strain, displacement and bearing capacity, through the finite element analysis software ANSYS. The result indicates that the rib can effectively improve the ductility, delaying the buckling occurs, which enhances the core concrete confinement effect, so as the stimulated ultimate bearing capacity which is greater than nominal ultimate bearing capacity.


2010 ◽  
Vol 163-167 ◽  
pp. 3826-3829
Author(s):  
Feng Yu ◽  
Ping Wu

FRP-confined concrete filled steel tube may fully use the character of FRP-confined concrete and concrete filled steel tube. Based on the analysis of existing experimental data, the formula of ultimate bearing capacity of FRP-confined concrete filled steel tube is proposed. The mechanical behavior of FRP-confined concrete filled steel tube is mainly related to the equivalent confinement effect coefficient before the rupture of FRP. Based on the static equilibrium condition, the equivalent conversion section is adopted; taking as main parameter, the simplified stress-strain model of FRP-confined concrete filled steel tube is established. The predictions of the model agree well with test data.


2008 ◽  
Vol 400-402 ◽  
pp. 677-683 ◽  
Author(s):  
Yu Yin Wang ◽  
Yuan Long Yang ◽  
Su Mei Zhang ◽  
Jie Peng Liu

Concrete-filled special-shaped (L-shaped, T-shaped, and cross-shaped, and etc.) steel tube column is a type of member in which concrete is poured into special-shaped steel tube so that steel and concrete support loads together. It improves the seismic behaviors of reinforced concrete special-shaped columns due to the better confining effects provided by the steel tube. A test research on the seismic behaviors of one concrete-filled T-shaped steel tube column with pseudo static method is presented and the load-displacement curve and skeleton curve are provided. Series of steel bar stiffeners were welded onto the steel tube in order to postpone the buckling of steel tube and to enhance confining effects. A numerical analysis program was developed using a fiber-based method. The constitutive model of concrete employed the modified Mander model, and that of steel employed a bi-linear model considering the Bausinger effect. The numerical analysis program was verified by the test results and parametric analysis was carried out, in which the influences of the ratio of axial compression stress to strength, steel tube thickness and concrete strength were mainly discussed. The following conclusions are obtained: with the increase of the ratio of axial compression stress to strength, the bearing capacity of member increases and the energy dissipation capacity improve, while the ductility deteriorates. With the increase of steel tube thickness, the initial rigidity, bearing capacity, ductility and energy dissipation capacity improves simultaneously. With the increase of concrete strength, the bearing capacity increases, the energy dissipation capacity improves, while the ductility deteriorates.


Sign in / Sign up

Export Citation Format

Share Document