Structural Characterization of Prismatic Stacking Faults of Two Types of Carrot Defects in 4H-SiC Epi Wafers

2020 ◽  
Vol 1004 ◽  
pp. 421-426
Author(s):  
Hideki Sako ◽  
Kentaro Ohira ◽  
Kenji Kobayashi ◽  
Toshiyuki Isshiki

Two types of carrot defects with and without a shallow pit were found by mirror projection electron microscopy (MPJ) inspection in 4H-SiC epi wafer. Surface morphology and cross-sectional structure of prismatic stacking faults (PSFs) were investigated using MPJ and atomic force microscopy (AFM), transmission electron microscopy (TEM) and high-resolution scanning transmission electron microscopy (STEM). The depths of the surface grooves due to the PSFs, the stacking sequences around the PSFs and the structure of the Frank-type stacking faults which were connected to the PSFs were different. We discuss the difference between the two types of carrot defects.

Nanomaterials ◽  
2018 ◽  
Vol 9 (1) ◽  
pp. 18 ◽  
Author(s):  
Jean-Marie Teulon ◽  
Christian Godon ◽  
Louis Chantalat ◽  
Christine Moriscot ◽  
Julien Cambedouzou ◽  
...  

Nanoparticles are defined as elementary particles with a size between 1 and 100 nm for at least 50% (in number). They can be made from natural materials, or manufactured. Due to their small sizes, novel toxicological issues are raised and thus determining the accurate size of these nanoparticles is a major challenge. In this study, we performed an intercomparison experiment with the goal to measure sizes of several nanoparticles, in a first step, calibrated beads and monodispersed SiO2 Ludox®, and, in a second step, nanoparticles (NPs) of toxicological interest, such as Silver NM-300 K and PVP-coated Ag NPs, Titanium dioxide A12, P25(Degussa), and E171(A), using commonly available laboratory techniques such as transmission electron microscopy, scanning electron microscopy, small-angle X-ray scattering, dynamic light scattering, wet scanning transmission electron microscopy (and its dry state, STEM) and atomic force microscopy. With monomodal distributed NPs (polystyrene beads and SiO2 Ludox®), all tested techniques provide a global size value amplitude within 25% from each other, whereas on multimodal distributed NPs (Ag and TiO2) the inter-technique variation in size values reaches 300%. Our results highlight several pitfalls of NP size measurements such as operational aspects, which are unexpected consequences in the choice of experimental protocols. It reinforces the idea that averaging the NP size from different biophysical techniques (and experimental protocols) is more robust than focusing on repetitions of a single technique. Besides, when characterizing a heterogeneous NP in size, a size distribution is more informative than a simple average value. This work emphasizes the need for nanotoxicologists (and regulatory agencies) to test a large panel of different techniques before making a choice for the most appropriate technique(s)/protocol(s) to characterize a peculiar NP.


2020 ◽  
Vol 1004 ◽  
pp. 414-420
Author(s):  
Junro Takahashi ◽  
Kotaro Kawaguchi ◽  
Kazuhiko Kusunoki ◽  
Tomoyuki Ueyama ◽  
Kazuhito Kamei

We have studied the microstructure of the growth surface of the 4H-SiC grown by the m-face solution growth. Atomic Force Microscopy (AFM) revealed the micro-striped morphology with the asperity of several nm in the band-like morphology region. The cross-sectional Transmission Electron Microscopy (XTEM) showed that the growth surface consisted of a bunch of nanofacets and vicinal surface. This peculiar morphology is totally different from that of conventional spiral growth on c-face, which can be closely related with the growth mechanism of the m-face solution growth.


2008 ◽  
Vol 381-382 ◽  
pp. 525-528 ◽  
Author(s):  
B.L. Wang ◽  
Han Huang ◽  
Jin Zou ◽  
Li Bo Zhou

Silicon (100) substrates machined by chemo-mechanical-grinding (CMG) and chemicalmechanical- polishing (CMP) were investigated using atomic force microscopy, cross-sectional transmission electron microscopy and nanoindentation. It was found that the substrate surface after CMG was slightly better than machined by CMP in terms of roughness. The transmission electron microscopy analysis showed that the CMG-generated subsurface was defect-free, but the CMP specimen had a crystalline layer of about 4 nm in thickness on the top of the silicon lattice as evidenced by the extra diffraction spots. Nanoindentation results indicated that there exists a slight difference in mechanical properties between the CMG and CMP machined substrates.


2002 ◽  
Vol 737 ◽  
Author(s):  
Susan Y. Lehman ◽  
Alexana Roshko ◽  
Richard P. Mirin ◽  
John E. Bonevich

ABSTRACTThree samples of self-assembled In0.44Ga0.56As quantum dots (QDs) grown on (001) GaAs by molecular beam epitaxy (MBE) were studied using atomic force microscopy (AFM) and high-resolution transmission electron microscopy (TEM) in order to characterize the height, faceting, and densities of the QDs. The cross-sectional TEM images show both pyramidal dots and dots with multiple side facets. Multiple faceting has been observed only in dots more than 8.5 nm in height and allows increased dot volume without a substantial increase in base area. Addition of a GaAs capping layer is found to increase the diameter of the QDs from roughly 40 nm to as much as 200 nm. The areal QD density is found to vary up to 50 % over the central 2 cm x 2 cm section of wafer and by as much as 23 % on a length scale of micrometers.


2004 ◽  
Vol 832 ◽  
Author(s):  
R. Krishnan ◽  
Q. Xie ◽  
J. Kulik ◽  
X.D. Wang ◽  
T.D. Krauss ◽  
...  

ABSTRACTSingle layers of isolated, size-controlled silicon nanocrystals were prepared by thermal crystallization of a thin amorphous silicon layer sandwiched between silicon dioxide layers. A subsequent oxidation treatment ensured controlled increase in their lateral separation. The size of the nanocrystals, separation of the nanocrystals (from < 1 nm to ∼ 4 nm), stoichiometry of the resulting oxide and surface morphology were monitored with transmission electron microscopy, scanning transmission electron microscopy, atomic force microscopy, and x-ray photoelectron spectroscopy. Mesoscopic charge transport studies performed with an electrostatic force microscope (EFM) revealed rapid lateral transport of charges when the nanocrystals were tightly packed (< 1 nm average separation) and interconnected. As the inter-nanocrystal separation was increased, lateral charge transport was rapidly suppressed. Nanocrystals separated by up to 3.6 nm retained the injected charges in a well-defined localized region (∼ 62 nm diameter region) for a time of the order of several days. The ability to switch from a very short to a very long retention time using the same structure by simply changing the post-growth processing conditions is attractive for various applications involving charge transport and localization.


1995 ◽  
Vol 378 ◽  
Author(s):  
G. Kissinger ◽  
T. Morgenstern ◽  
G. Morgenstern ◽  
H. B. Erzgräber ◽  
H. Richter

AbstractStepwise equilibrated graded GexSii-x (x≤0.2) buffers with threading dislocation densities between 102 and 103 cm−2 on the whole area of 4 inch silicon wafers were grown and studied by transmission electron microscopy, defect etching, atomic force microscopy and photoluminescence spectroscopy.


2017 ◽  
Vol 23 (3) ◽  
pp. 661-667 ◽  
Author(s):  
Yue Li ◽  
Di Zhang ◽  
Ilker Capoglu ◽  
Karl A. Hujsak ◽  
Dhwanil Damania ◽  
...  

AbstractEssentially all biological processes are highly dependent on the nanoscale architecture of the cellular components where these processes take place. Statistical measures, such as the autocorrelation function (ACF) of the three-dimensional (3D) mass–density distribution, are widely used to characterize cellular nanostructure. However, conventional methods of reconstruction of the deterministic 3D mass–density distribution, from which these statistical measures can be calculated, have been inadequate for thick biological structures, such as whole cells, due to the conflict between the need for nanoscale resolution and its inverse relationship with thickness after conventional tomographic reconstruction. To tackle the problem, we have developed a robust method to calculate the ACF of the 3D mass–density distribution without tomography. Assuming the biological mass distribution is isotropic, our method allows for accurate statistical characterization of the 3D mass–density distribution by ACF with two data sets: a single projection image by scanning transmission electron microscopy and a thickness map by atomic force microscopy. Here we present validation of the ACF reconstruction algorithm, as well as its application to calculate the statistics of the 3D distribution of mass–density in a region containing the nucleus of an entire mammalian cell. This method may provide important insights into architectural changes that accompany cellular processes.


Sign in / Sign up

Export Citation Format

Share Document