scholarly journals Isolation of Iron Bacteria from Washing Sludge Filters Kolda (Senegal) Water Treatment Station and Study of the Kinetics of Biological Degradation of the Iron (II)

2019 ◽  
Vol 09 (03) ◽  
pp. 19-32
Author(s):  
Mamadou Faye ◽  
Falilou Mbacké Sambe ◽  
Modou Dieng ◽  
Alpha Ousmane Touré ◽  
Matar Faye ◽  
...  
DYNA ◽  
2016 ◽  
Vol 83 (196) ◽  
pp. 223-228 ◽  
Author(s):  
Jhonnathan Machado-Infante ◽  
Gustavo Ramírez-Caballero ◽  
Martha Juliana Barajas Meneses

<p>In Colombia, a mineral rich in MnO<sub>2</sub> is extracted from the mines of Mallama, Nariño. In this work we studied the adsorption capacity of this mineral for Fe(II) dissolved in aqueous solution of open systems. The characterization was done through ICP-AES, XRF and Raman spectroscopy. The effect of different pretreatments on the mineral with oxidizing agents such as KMnO<sub>4</sub> and NaClO was evaluated. Studies of equilibrium and kinetics of adsorption showed that the mechanism fits well to the Langmuir isotherm and its kinetics to a model of pseudo-second order. At the conditions studied was found that the adsorption capacity for the mineral modified with KMnO<sub>4</sub> and NaOCl were 59.209 and 51.279 mg/g respectively. It is concluded that the mineral is a potential alternative in water treatment.</p>


2016 ◽  
Vol 17 (3) ◽  
pp. 752-758 ◽  
Author(s):  
Sam Hancock ◽  
Martin Harris ◽  
David Cook

Rapid monochloramine decay has been observed in the product water of three River Murray water treatment plants (WTPs). Previous investigations identified that rapid monochloramine decay was microbiological in nature and observed in samples taken after media filtration but was absent in filtered water samples from a fourth WTP of similar design. The filters at the WTP not exhibiting rapid decay are backwashed with filtered non-disinfected water whereas the other WTPs backwash with treated chloraminated water. It was therefore hypothesised that backwashing filters with chloraminated water was the cause of the rapid monochloramine decay. A pilot-scale study was conducted to investigate the impact of backwashing with chloraminated water on the occurrence of microbiologically accelerated monochloramine decay. Additional samples were analysed to assess the impact of chloraminated backwash water on N-Nitrosodimethylamine (NDMA) formation and biological degradation of taste and odour compounds 2-methyl isoborneol (MIB) and geosmin in the filter media. Backwashing with chloraminated filtered water was concluded to be the cause of the observed rapid monochloramine decay, with rapid decay observed within 8 weeks for the filters backwashing with chloramines. Additionally, backwashing with chloraminated filtered water was observed to increase NDMA formation and impair the biological degradation performance of MIB and geosmin.


2013 ◽  
Vol 756-759 ◽  
pp. 121-123
Author(s):  
Millena Bertolini Galzerano ◽  
Letícia Torres Bressan ◽  
Rosa Cristina Cecche Lintz ◽  
Lubienska Cristina Lucas Jaquiê Ribeiro ◽  
Marta Siviero Guilherme Pires ◽  
...  

Currently, the SCC is already used in several countries and is considered a breakthrough in the building process of concrete structures, as it increases productivity, reduces the demand for labor, work in time of concreting and improves the quality of the concrete and the environment work. Innumerous investigations on SCC [,[,[,[ have been developing in order to know their behavior, improve their properties and applicability in different structural elements. This paper presents the implementation of the SCC in the execution of the base of the waters reservoir, in water treatment station.


Sign in / Sign up

Export Citation Format

Share Document